Viking Range 5 Series VGC Technical manual

Use/Installation
GUIDE
5 SERIES
Rear Downdraft Ventilators
VDD5300
VDD5360
VDD5450
VDD5480

2
MODEL WIDTH BLOWER (purchased separately)
VDD5300 30" W. VDVI600 Interior or VDVE900 Exterior
VDD5360 36" W. VDVI600 Interior or VDVE900 Exterior
VDD5450 45" W. VDVI600 Interior or VDVE900 Exterior, VDVE1200 Exterior
VDD5480 48" W. VDVI600 Interior or VDVE900 Exterior, VDVE1200 Exterior
WARNING
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
Ifyouhavequestions,contactthemanufacturerattheaddress
or telephone number in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualied person(s) in accordance with all applicable codes
and standards, including re-rated construction codes and
standards.
4. Sufcient air is needed for proper combustion and exhausting
of gases through the ue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of re, use only metal ductwork.
8. Do not install this product with the activating switch directly
behind a burner or element. Minimum distance between the
switch and the edge of the burner should be 4 inches.
9. Loose-tting or hanging clothing should never be worn when
operating this appliance. They may be ignited by burners/
elements on cooktop.
10.Children should not be left alone or unattended in the area
where this appliance is in use.
11. This unit must be grounded.
12.To reduce the risk of re or electric shock, it is recommended
thatthedowndraftbe installedwith adedicatedcircuitseparate
from the appliance.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
cooking aming foods.
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or lter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OFA RANGE TOP GREASE FIRE,OBSERVETHEFOLLOWING*:
1. SMOTHER FLAMES with a close-tting lid, cookie sheet, or
metaltray,thenturn offtheburner. BE CAREFUL TO PREVENT
BURNS. If the ames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The re is small and contained in the area where it started.
C. The re department is being called.
D. You can ght the re with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
CAUTION
1. TOREDUCETHE RISK OF FIRE OR INJURY, DO NOT INSTALL
WITH COOKING PRODUCTS THAT HAVE A GRIDDLE.
2. For indoor use only.
3. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
4. To avoid motorbearingdamageandnoisyand/orunbalanced
impellers,keep drywall spray, construction dust, etc. offpower
unit.
5. Clean lters and grease-laden surfaces frequently.
6. Do not repair or replace any part of this appliance unless
specically recommended in this manual. All other servicing
should be done by a qualied technician.
7. Please read specification label on product for further
information and requirements.
8. To reducetherisk ofreandelectric shock,install thisdowndraft
only with blower models shown below. Other blower models
cannot be substituted. (Blowers sold separately).
Flex Blower Model VDVI600
Exterior Blower Models VDVE900, VDVE1200
9. To reducetherisk ofreandelectric shock,install thisdowndraft
only with non-ducted recirculating kit - ARKD.
!
INSTALLER:
Save this manual for Electrical Inspector
and Homeowner to use.

3
PLANNING
ELECTRICAL SPECIFICATIONS
Model VDVI600 - Internal Flex:
120 VAC • 60 Hz • 3.0 A
Models VDVE900, VDVE1200 - Exterior
120 VAC • 60 Hz • 6.0 A (max.)
TAKE MEASUREMENTS
DO NOT INSTALL WITH COOKING PRODUCTS THAT HAVE A
GRIDDLE.
Due to its exible design, this downdraft system can be used to
exhaust airborne contaminants when cooking with a variety of gas or
electric cooking appliances - including cooktops, rangetops, slide-in
ranges and free-standing ranges.
Itcanbemountedinisland,peninsula,or conventionalwall location.The
blower(purchaseseparately)andelectrical panelcan bemountedtothe
downdraft unit, inside the cabinet, or in a convenient remote location.
This unit can be easily installed following these basic steps:
• Cut out the countertop opening.
• Mount the unit in the cabinet.
• Install the blower and electrical panel.
• Connect the ductwork and electrical.
• Mount the trim.
• Install the cooking appliance.
Note: the high level of air ow of this appliance may effect the gas
ame on some types of gas cooktops. This is NORMAL and will cause
no harm, but can be corrected by lowering the speed of the blower.
PLAN THE DUCTWORK
1. Refer to the cooktop installation instructions for dimensions of
cooktop,countertopcut-out,and cabinet requirements.However,
it is recommended that oversized cabinets be used for easier
installation.
2. Cooktop depth can vary greatly from one to another. This may
cause the t of these two appliances to be rather tight.
Pay special attention to the areas of potential interference highlighted
below. A countertop with (A) a raised lip and/or (B) a backsplash may not
allow enough at countertop for a proper installation. Note that 2-3/4" of
at countertop is required behind cooktop and that 2-7/8" is necessary
between the back edge of the cooktop and the inside of cabinet back.
AB
C
DE
F
HD1101
G
HOUSING
1. The downdraft blower system is designed for use with
8" round ductwork using a ex blower or 10" Round
ductwork using a remote blower. (Purchase blowers
separately.) Seven (7) different discharge connections
are available - with side-to-side adjustment for
accurate alignment of ductwork:
A = 8" Round, Left Discharge out of Flex Blower
B = 8" Round, Right Discharge out of Flex Blower
C = 8" Round, Down Discharge out of Flex Blower
(Electrical Panel to be mounted remotely)
D = 1-7/8" x 19", Left Discharge out of Housing
to Remote Blower or Flex Blower in remote
location. Use 1-7/8" x 19" to 8" round transition,
1-7/8" x 19" to 10" round transition,
or 1-7/8" x 19" ductwork as appropriate.
E = 1-7/8" x 19", Right Discharge out of Housing
to Remote Blower or Flex Blower in remote
location. Use 1-7/8" x 19" to 8" round transition,
1-7/8" x 19" to 10" round transition,
or 1-7/8" x 19" ductwork as appropriate.
F = 1-7/8" x 19", Rear Discharge out of Housing
to Remote Blower or Flex Blower in remote
location. Use 1-7/8" x 19" to 8" round transition,
1-7/8" x 19" to 10" round transition,
or 1-7/8" x 19" ductwork as appropriate.
G = 1-7/8" x 19", Below Discharge out of Housing
to Remote Blower or Flex Blower in remote
location. Use 1-7/8" x 19" to 8" round transition,
1-7/8" x 19" to 10" round transition,
or 1-7/8" x 19" ductwork as appropriate.
2. For best performance: Choose the ducting option which
allows the shortest length of ductwork and a minimum
number of elbows and transitions. Check location of
oor joists, wall studs, electrical wiring or plumbing for
possible interference.
CONTENTS
These parts are included with your downdraft housing:
1 - Parts Bag
2 - Support Legs
1 - Trim Kit
1 - Electrical Panel
2 - Support Brackets
2-7/8"
A
B
2-3/4"
Downdraft
Cooktop
Front to Back
Inside Cabinet Depth
CountertopCountertop
FLEX
BLOWER *
*Remote blowers use 8" or 10" round remote discharge
plate instead of ex blower.
Note: Remove all protective lm and packaging before
operation. In order to remove all protective lm and
packaging, raise the ventilator housing and remove the
front panel to access the lter area.

4
PLAN THE WIRING
1. This downdraft blower using the Flex Blower (purchase
separately) draws 3.0 Amps and requires a 120 VAC, 60 Hz
circuit. If using a remote blower (purchase separately), the
system draws 6.0 Amps (max.) and requires a 120 VAC,
60 Hz circuit.
2. The unit has a 30 in. long power cord with a 3-pronged plug.
Plan to provide a grounded outlet in a location which will
allow the unit’s power cord to reach.
3. Install electrical box according to local codes.
4. The length of cable from the electrical box to the downdraft
is 20 in.
5. The length of blower (sold separately) cable to the electrical
box is 5 ft.
PREPARE THE DOWNDRAFT
1. Place the downdraft on its back on a table or at work surface.
2. Detach the UPPER SUPPORT BRACKETS from the downdraft
by cutting off the tie wraps. Remove and set aside both
SUPPORT LEGS from sides of the downdraft (one leg per
side).
Note: Discard the retaining screws, but KEEP THE NUTS.
Remove the bundle of 3 DISCHAGE COVERS from the
bottom of the downdraft.
DISCHARGE COVERS
(REMOVE AND KEEP NUTS)
UPPER SUPPORT
BRACKETS
SUPPORT LEGS
(KEEP NUT,
DISCARD SCREWS)
PLAN CABINET CUTOUTS
!
CAUTION:
BEFORE CUTTING HOLE IN CABINET FOR
DUCTWORK, check for interference with oor
joists, wall studs, electrical wiring, or plumbing.
Use the dimensions in the above illustration to help plan how and
where to provide duct access through your cabinet. Generally,
1-7/8" x 19" rectangular duct will be used through left, right,
through cabinet oor and back of cabinet - while 8" round duct
will be used through cabinet oor.
For left, right, or rear exhaust:
Allow at least 18" for transition and elbow or blower.
For left/right exhaust:
A 30" deep cabinet is recommended to align properly with
ex blower. Flex blower can be mounted to rear cabinet
wall or to a platform/frame (not provided) on the base of the
cabinet oor. (See ex blower instructions).
Cabinet depths of 24" to 30" are required - depending on the
type of cooking appliance.
INSTALLATION
CENTER LINE
HOLE FOR
17/8” x 19”
DUCT &
TRANSITIONS
INSIDE
CABINET BACK
INSIDE
CABINET FLOOR
21”
centered 4”
21”
REAR CORNER OF
COOKTOP CUT-OUT
24¾”
FLUSH
5 ”
/8
7
4”
HOLE FOR 8” or
10” ROUND DUCT
(*Adjustable 6” Left and 6” Right)
(When using Remote Discharge Plate -
Hole is adjustable 6” Left and 6” Right
from Installation Center Line.
)
1½” **
6”* 6”*
** Using Flex Blower,
1½” Left from Installation
Center Line
3. Cover the discharge openings that won’t be used for ducting.
Note: Use the NUTS previously removed.

5
Installations ducting through front panel opening only:
1. Remove the HEX NUTS on both CLAMP CHANNELS, and
detach from the unit. Remove the FRONT PANEL COVER.
FRONT PANEL COVER
CLAMP
CHANNELS
6 HEX
NUTS
Installations using FLEX BLOWER only:
(Purchase Model VDVI600 Flex Blower separately.)
Note: Remove adapter plate from Flex Blower per instructions
packed with blower.
2. Determine its location on FRONT PANEL and whether it will
discharge to the left, right, or down.
Use a combination of COVER PLATES (3" and/or 6" wide) to
close the opening on side(s) of blower.
Insert the blower and cover plates bottom anges in the
LOWERCHANNEL, then reinstalltheclampchannels.Tighten
the hex nuts to secure blower, panels and clamp channels in
place.
LOWER
CHANNEL
COVER
PLATE COVER PLATES
(included
with blower)
FLEX
BLOWER
FRONT
PANEL
If blower
discharge is
down, electrical
panel must be relocated.
See Step 5.
Electrical panel
can be mounted remotely.
Installations using FLEX BLOWER (in remote location)
or REMOTE BLOWER only:
3. Use the REMOTE DISCHARGE PLATE and determine its
location on FRONT PANEL.
Use a combination of COVER PLATES (3" and/or 6" wide) to
close the opening on side(s) of remote discharge plate.
Insert the remote cover plate and cover plates in the LOWER
CHANNEL,then reinstallthe clampchannels. Tightenthe hex
nuts to secure the plates and clamp channels in place.
LOWER
CHANNEL
8" OR 10" ROUND
REMOTE DISCHARGE
PLATE (Purchase Separatly)
FRONT
PANEL
COVER PLATES
COVER PLATE
CLAMP
CHANNELS
CLAMP
CHANNELS

6
All Installations:
4. Slide UPPER SUPPORT BRACKETS into SLIDE CHANNEL at
top left and right of unit.
Attach previously removed SUPPORT LEGS to downdraft
using one nut for each leg. Do not tighten nut completely
at this time.
SLIDE
CHANNEL
SUPPORT
LEG
UPPER
SUPPORT
BRACKET
Installations where ELECTRICAL PANEL needs to be
mounted in a remote location only:
5. Remove (4) HEX NUTS and ELECTRICAL PANEL. 5-ft.
extension cables (purchase separately) may be needed to
mount electrical panel in a remote location. Do not use more
that 2 extension cables. Do not mount electrical panel with
vent holes facing down.
18-3/16” (46.2 cm)
17-7/16” (44.3 cm) Slot Center
4-1/2”
(11.4 cm)
Slot Center
6-1/4”
(15.9 cm)
16-1/4” (15.9 cm)
6-5/8”
(16.8 cm)
Electrical Panel Dimensions
Flex Blower
shown
installed.

7
Installations using FLEX BLOWER only:
6. Attach BLOWER SUPPORT LEGS with (4) BOLTS provided.
BLOWER
SUPPORT
LEGS
(4) BOLTS
CAUTION: If ex blower will be mounted remotely:
Do not use legs alone for support. It may be
necessary to add extra support for the ex blower.
Use mounting brackets supplied with the blower.
!
Installations ducting through left, right, below or rear only:
(Requires purchase of 1-7/8" x 19" to 8" or 10" round transition
or 1-7/8" x 19" duct adapter with rectangular duct cut to
appropriate length.)
7. Use nuts to connect 1-7/8” x 19” rectangular ductwork
connection adapter or 1-7/8” x 19” to 8” or 10” round
transition to housing when installing ductwork.
CUT COUNTERTOP OPENING
1. Lay out and cut the cooktop cut-out far enough FORWARD
so downdraft will t behind it.
2. Set cooktop in place and slide it as far forward as possible
without exposing an gaps. Center and square it with edges
of countertop.
3. Place the plastic template against the back ange of the
cooktop or back edge of slide-in range countertop opening.
Center the template. Trace around template to mark the
downdraft opening.
4. Remove cooktop from countertop.
5. Cut downdraft opening. Be careful not to chip edges of
countertop.
Template against back
edge of cooktop.
COOKTOP

8
INSTALL HOUSING INTO
CABINET
1. Remove cooktop.
2. Set housing into cabinet / countertop opening as far back as
possible and make sure it is level.
3. Extend SUPPORT LEGS and attach to bottom of cabinet with
(2) SCREWS through each leg. Tighten HEX NUTS.
HEX NUT
4. Extend UPPER SUPPORT BRACKETS and attached to sides
of cabinet with (2) SCREWS through each bracket.
UPPER
SUPPORT
BRACKET
1
5. Loosen (4) BOLTS attaching BLOWER SUPPORT LEGS to FLEX
BLOWER. Extend legs and secure them to bottom of cabinet
with a SCREW through each bracket.
FLEX
BLOWER
(4)
BOLTS
SCREWS
Installations using FLEX BLOWER only:
(2) SCREWS
1
SUPPORT LEGS
(2)
SCREWS
HEX NUT

9
INSTALL ELECTRICAL WIRING
1. Mount a standard wiring box, with 3-pronged receptacle,
within reach of the downdraft's power cord.
2. Run appropriate power cable and connect it to receptacle.
3. Connect blower wires to wires in wiring box. Black to black,
white to white, blue to blue, orange to orange, gray to red,
and green to ground screw.
4. Replace wiring box cover.
5. Plug ELECTRICAL PANEL CABLE into RECEPTACLE at
bottom/right of downdraft housing.
6. Plug the downdraft's power cord into the outlet. Make sure
that the power cord is routed away from the heat generated
by the cooktop.
!
CAUTION: All electrical wiring should be done by a
qualied person(s) in accordance with all applicable
codes and standards.
1. Mount a standard wiring box, with 3-pronged receptacle,
within reach of the downdraft's power cord.
2. Run appropriate power cable into cabinet and connect it to
electrical box and receptacle.
3. These exterior blowers can be used:
Models VDVE900, VDVE1200 - Exterior
120 VAC • 60 Hz • 6.0 A (max.)
!
CAUTION: All electrical wiring should be done by a
qualied person(s) in accordance with all applicable
codes and standards.
Installations using FLEX BLOWER only:
Installations using REMOTE BLOWER only:
4. Run 2-wire plus ground power cable from the exterior blower
towiring box onadaptorplate. Remove WIRINGBOXCOVER.
5. Connect blower wires to power cable from exterior blower.
Black to black, white to white, and green to ground screw.
6. Replace wiring box cover.
7. Plug ELECTRICAL PANEL CABLE into RECEPTACLE at
bottom/right of downdraft housing.
8. Plug the downdraft's power cord into the outlet. Make sure
that the power cord is routed away from the heat generated
by the cooktop.
INSTALL DUCTWORK
1. Cuthole in cabinet as well as holes in wallor oor as necessary.
2. Mount the roof or wall cap and work back towards the cabinet,
attaching all ductwork, elbows and transitions as previously
planned. Tape all ductwork connections to make them secure
and air tight.
3. Connect ductwork (and transition, if required) to downdraft.
!
CAUTION: Before cutting hole in cabinet for
ductwork, check for interference with oor joists,
wall studs, electrical wiring, or plumbing.
WIRING BOX COVER
RECEPTACLE
ELECTRICAL
PANEL CABLE
CABINET BOTTOM

10
INSTALL FINISH TRIM
1. AttachFINISHTRIM totop/leftand top/right ofDOWNDRAFT
HOUSING with screws provided.
INSTALL COOKING APPLIANCE
1. Align the cooking appliance with downdraft and fasten
appliance in place following appliance instructions.
Note: Accurate alignment of cooking appliance and downdraft
is necessary to ensure that there is no interference when air vent
is raised and lowered. There should be a gap of 1/32" - 1/16"
between the back of the cooktop and the front of the downdraft
cover.
MAKE-UP AIR DAMPER (OPTIONAL)
Connects to 2 CONTACTS on ELECTRICAL PANEL.
Compatible with G6MD and G8MD damper.
FINISH
TRIM
SCREWS
COUNTERTOP
CHIMNEY
DOWNDRAFT
HOUSING
Available for application with free-standing range - where gap
is present between back of range and downdraft.
RANGE TRIM KIT (OPTIONAL)
MAKE-UP AIR
DAMPER
CONTACTS
ELECTRICAL
PANEL

11
OPERATION
4-Speed Fan Speed Control
Press + button to increase fan speed.
Press - button to decrease fan speed.
After maximum speed is reached, press + button once more to
turn off fan.
2-Level Task Light
Press once for LOW setting.
Press 2x for HIGH setting. Icon will illuminate.
Press 3x to turn task light OFF.
30-Hour Filter Clean Reminder
After 30 hours of blower "ON" time, lter clean icon will blink
continuously.
To reset, touch and hold icon for 2 or more seconds. Indicator
will turn off.
4-Speed Fan Speed Control
2-Level Task Light
30-Hour Filter Clean Reminder
Up / Down
Button
Up / Down Button
To raise / lower chimney, touch up / down button. Any
feature that is active will shut off when chimney is retracting.
All functions will return to their previous settings when
chimney is raised.

12
USE AND CARE
Always turn the downdraft blower on before you begin cooking
to establish an air ow in the kitchen. Let the blower run for a
few minutes to clean the air after you turn the cooktop off. This
will keep the whole kitchen cleaner and brighter.
WARNING: Always disconnect electric power
supply before cleaning and/or servicing unit.
Cleaning
Servicing
It may be necessary to remove the downdraft blower system from
the cabinet in order to service components such as the blower
motor or air vent mechanism.
Disconnect power to the cooktop and remove it rst. Reverse
the steps under “INSTALL HOUSING INTO CABINET” to remove
the downdraft from the cabinet.
To clean grease lters: Remove front panel and take out the
(2) grease lters. Wash lters in a mild detergent solution or a
dishwasher. Replace lters before using downdraft.
To clean inside chimney: Remove lters. Pull front panel up and
out. Use a mild detergent. DO NOT USE ABRASIVE CLOTH,
STEEL WOOL PADS, OR SCOURING POWDERS. Replace front
panel and lters before using downdraft.
SERVICE INFORMATION
Only authorized replacement parts may be used in performing
service on the appliance.
All servicing should be referred to a qualied technician.
Contact Viking Range, LLC, 1-888-(845-4641), for the nearest
service parts distributor in your area or write to:
VIKING RANGE, LLC
PREFERRED SERVICE
111 Front Street
Greenwood, Mississippi 38930 USA
Record the following information indicated below. You will
need it if service is ever required.
Model number __________________________________________
Serial number ___________________________________________
Date of purchase ________________________________________
Date installed ___________________________________________
Dealer’s name ___________________________________________
Address ________________________________________________
________________________________________________________
These installation instructions should remain with the unit for
future reference.

DOWNDRAFT WARRANTY
ONE YEAR FULL WARRANTY
Downdrafts and all of their component parts, except as detailed below*†, are warranted to be free from defective materials or workmanship in normal residential use for
a period of one (1) year from the date of original retail purchase. Viking Range, LLC, warrantor, agrees to repair or replace, at its option, any part which fails or is found
to be defective during the warranty period.
*FULL NINETY (90) DAY COSMETIC WARRANTY: Product is warranted to be free from cosmetic defects in materials or workmanship (such as scratches on
stainless steel, paint/porcelain blemishes, etc.) for a period of ninety (90) days from the date of original retail purchase or closing date for new construction,
whichever period is longer. Any defects must be reported to the selling dealer within ninety (90) days from date of original retail purchase. Viking Range,
LLC uses high quality processes and materials available to produce all color nishes. However, slight color variation may be noticed because of the inherent
differences in painted parts and porcelain parts as well as differences in kitchen lighting, product locations, and other factors. Therefore, this warranty does
not apply to color variation attributable to such factors.
†FULL NINETY (90) DAY WARRANTY IN "RESIDENTIAL PLUS" APPLICATIONS: This full warranty applies to applications where use of the product
extends beyond normal residential use, but the warranty period for products used in such applications is ninety (90) days. Examples of applications covered
by this warranty are bed and breakfasts, re stations, private clubs, churches, etc. Under this "Residential Plus" warranty, the product, its components and
accessories are warranted to be free from defective material or workmanship for a period of ninety (90) days from the date of original retail purchase. This
warranty excludes use of the product in all commercial locations such as restaurants, food service locations and institutional food service locations.
FIVE YEAR LIMITED WARRANTY ON VENTILATION MOTORS
Any ventilator motor which fails due to defective materials or workmanship (excluding cosmetic failures) in normal household use during the fourth through fth year
from the date of original retail purchase will be repaired or replaced, free of charge for the part itself, with the owner paying all other costs, including labor. This does not
include ignition systems, burner bases, etc.
TERMS AND CONDITIONS
This warranty extends to the original purchaser of the product warranted hereunder and to each transferee owner of the product during the term of the warranty
and applies to products purchased and located in the United States, Mexico, and the Caribbean (excluding Cuba, Dominican Republic, and Haiti). Products must be
purchased in the country where service is requested. If the product or one of its component parts contains a defect or malfunction during the full warranty period after
a reasonable number of attempts by the warrantor to remedy the defect or malfunction, the owner is entitled to either a refund or replacement of the product or its
component part or parts. Replacement of a component part includes its free installation, except as specied under the limited warranty. Under the terms of this warranty,
service must be performed by a factory authorized Viking Range, LLC service agent or representative. Service will be provided during normal business hours, and labor
performed at overtime or premium rates shall not be covered by this warranty.
Owner shall be responsible for proper installation, providing reasonable and necessary maintenance,providing proof of purchase upon request, and making the
appliance reasonably accessible for service. The return of the Owner Registration Card is not a condition of warranty coverage. You should, however, return the Owner
Registration Card so that Viking Range, LLC can contact you should any question of safety arise which could affect you.
This warranty gives you specic legal rights, and you may also have other rights which may vary from jurisdiction to jurisdiction.
WHAT IS NOT COVERED BY THIS WARRANTY: This warranty shall not apply to damage resulting from abuse, failure to provide reasonable and necessary
maintenance, accident, delivery, negligence, natural disaster, loss of electrical power to the product for any reason, alteration, outdoor use, improper installation,
improper operation, or repair or service of the product by anyone other than an authorized Viking Range, LLC service agency or representative. This warranty does not
apply to commercial usage.
LIMITATION OF REMEDIES AND DURATION OF IMPLIED WARRANTYOWNER’S SOLE AND EXCLUSIVE REMEDY FOR A CLAIM OF ANY KIND WITH RESPECT
TO THISPRODUCT SHALL BE THE REMEDIES SET FORTH ABOVE. VIKING RANGE IS NOT RESPONSIBLE FORCONSEQUENTIAL OR INCIDENTAL DAMAGE,
INCLUDING BUT NOT LIMITED TO FOOD ORMEDICINE LOSS, DUE TO PRODUCT FAILURE, WHETHER ARISING OUT OF BREACH OF WARRANTY, BREACH OF
CONTRACT OR OTHERWISE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusions
may not apply to you. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE APPLICABLE TO THIS PRODUCT ARE LIMITED
IN DURATION TO THE PERIOD OF COVERAGE OF THE APPLICABLE EXPRESS WRITTEN LIMITED WARRANTIES SET FORTH ABOVE. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
WARRANTY SERVICE
To obtain warranty service, contact an authorized Viking Range, LLC service agent, or Viking Range, LLC 111 Front Street, Greenwood, Mississippi 38930, (888) 845-
4641. Provide model and serial number and date of original purchase or closing date for a new construction. For the name of your nearest authorized Viking Range, LLC
service agency, call Viking Range, LLC. IMPORTANT: Retain proof of original purchase to establish warranty period.
Specications subject to change without notice.
WARRANTY
F21413K
99045252L
(022818)
VIKING RANGE, LLC
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For more product information, call 1-888-845-4641, or visit our web site at www.vikingrange.com

Utilisation/Installation
GUIDE
SÉRIE 5
Hottes arrière encastrées à
tirage descendant
VDD5300
VDD5360
VDD5450
VDD5480

15
MODÈLE LARGEUR VENTILATEUR (vendu séparément)
VDD5300 76,2 cm (30 po) de largeur VDVI600 intérieur ou VDVE900 extérieur
VDD5360 91,4 cm (36 po) de largeur VDVI600 intérieur ou VDVE900 extérieur
VDD5450 114,3 cm (45 po) de largeur VDVI600 intérieur ou VDVE900 extérieur, VDVE1200 extérieur
VDD5480 121,9 cm (48 po) de largeur VDVI600 intérieur ou VDVE900 extérieur, VDVE1200 extérieur
AVERTISSEMENT
LIRE CES DIRECTIVES ET LES CONSERVER
!
INSTALLATEUR:
Conservez ce manuel pour l'inspection
électrique et le propriétaire.
AVERTISSEMENT
OBSERVEZ LES DIRECTIVES CI-DESSOUS AFIN DE RÉDUIRE LES
RISQUES D'INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES
CORPORELLES :
1. N'utilisez cet appareil que de la manière prévue par le fabricant. Si
vous avez des questions, communiquez avec le fabricant à l'adresse
ou au numéro de téléphone indiqués dans la garantie.
2. Avant de procéder à l'entretien ou au nettoyage de l'appareil, coupez
l'alimentation du panneau électrique et verrouillez l'interrupteur
principal an d'empêcher que le courant ne soit accidentellement
rétabli. S'il est impossible de verrouiller l'interrupteur principal, xez
solidement un message d'avertissement, par exemple une étiquette,
sur le panneau électrique.
3. La pose de l'appareil et les travaux d'électricité doivent être effectués
par des personnes qualiées conformément à la réglementation en
vigueur, notamment les normes de la construction ayant trait à la
protection contre les incendies.
4. Pouréviterles refoulements,l'apportd'airdoit êtresufsantpourbrûler
les gaz produits par les appareils à combustion et les évacuer dans le
conduit de fumée (cheminée). Respectez les directives du fabricant
de l’appareil de chauffage et les normes de sécurité, notamment
celles publiées par la National Fire Protection Association (NFPA),
l'American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE) et les codes des autorités locales.
5. Veillez à ne pas endommager le câblage électrique ou d'autres
équipements non apparents lors de la découpe ou du perçage du
mur ou du plafond.
6. Les ventilateurs canalisés doivent toujours rejeter l'air à l'extérieur.
7. Pour réduire les risques d'incendie, utilisez seulement des conduits
en métal.
8. N’installez pas ce produit en plaçant son interrupteur directement
derrière un brûleur ou un élément. La distance minimale entre
l’interrupteur et le bord du brûleur est de 10,2 cm (4 pouces).
9. Ne portez jamais de vêtements ou accessoires amples lors de
l’utilisation de cet appareil. Ils peuvent s’enammer en raison des
brûleurs ou des éléments de la surface de cuisson.
10. Ne laissez jamais un enfant seul ou sans surveillance aux environs de
cet appareil lors de son utilisation.
11. Cet appareil doit être relié à une mise à la terre.
12. Pour réduire les risques d'incendie et de choc électrique, il est
recommandé d'installer cette hotte sur un circuit séparé de l'appareil
de cuisson.
POURRÉDUIRELESRISQUESD'INCENDIECAUSÉS PARDELAGRAISSE
SUR LE PLAN DE CUISSON:
a) Nelaissez jamais lesélémentsde surface allumésà haute température.
Les débordements peuvent causer de la fumée et occasionner des
écoulements de graisse inammables. L'huile doit être chauffée
graduellement à basse ou à moyenne température.
b) Mettez toujours la hotte en marche lors de la cuisson à haute
température ou lors de la cuisson d'aliments à amber.
c) Nettoyez souvent la hotte. Ne laissez pas la graisse s'accumuler sur
le ventilateur ou les ltres.
d) Utilisezdes casseroles de dimension appropriée.Utilisez toujoursune
batterie de cuisine adaptée à la dimension de la surface chauffante.
OBSERVEZ LES CONSIGNES SUIVANTES DE MANIÈRE À RÉDUIRE
LES RISQUES DE BLESSURES CORPORELLES EN CAS D'INCENDIE
CAUSÉ PAR DE LA GRAISSE SUR LE PLAN DE CUISSON* :
1. ÉTOUFFEZ LES FLAMMES à l'aide d'un couvercle étanche, d'une
tôle à biscuits ou d'un plateau en métal puis éteignez le brûleur.
FAITES ATTENTION DE NE PAS VOUS BRÛLER. SI LES FLAMMES
NE S'ÉTEIGNENT PAS IMMÉDIATEMENT, QUITTEZ LES LIEUX ET
APPELEZ LE SERVICE DES INCENDIES.
2. NE SOULEVEZ JAMAIS UNE CASSEROLE EN FLAMMES - vous
pourriez vous brûler.
3. N’UTILISEZ PAS D’EAU, ni de serviettes ou de linges mouillés – une
violente explosion de vapeur pourrait survenir.
4. Utilisez un extincteur SEULEMENT si:
A. Vous savez qu'il est de classe ABC et vous connaissez déjà son
mode de fonctionnement.
B. Le feu n'est pas très important et ne se propage pas.
C. Les pompiers ont été avisés.
D. Vous pouvez combattre le feu en faisant dos à une sortie.
* Conseils tirés de la publication de la NFPA « Kitchen Fire Safety Tips ».
ATTENTION
1. POUR RÉDUIRE LES RISQUES D'INCENDIE OU DE BLESSURES, NE
PAS INSTALLER AVEC UN APPAREIL DE CUISSON COMPORTANT
UNE GRILLE.
2. Pour usage intérieur seulement.
3. Pourventilation générale uniquement.N'utilisez pas cetappareilpour
évacuer des matières ou des vapeurs dangereuses ou explosives.
4. Pouréviterd'endommager les roulementsdumoteur,de déséquilibrer
les pales ou de les rendre bruyantes, débarrassez l'appareil de la
poussière de plâtre, de construction, etc.
5. Nettoyez fréquemment les ltres et les surfaces graisseuses.
6. Ne réparez ou ne remplacez aucune pièce de cet appareil à moins
que ce manuel le recommande précisément. Tout autre travail de
réparation doit être coné à un technicien qualié.
7. Veuillez lire l'étiquette de spécications du produit pour obtenir plus
de renseignements, notamment sur les exigences.
8. Pour réduire les risques d’incendie et de choc électrique, n’installez
cette hotte encastrée qu’avec les modèles de ventilateur indiqués
ci-dessous. D’autres ventilateurs ne peuvent pas leur être substitués.
(Ventilateurs vendus séparément.)
Ventilateur Flex de modèle VDVI600
Ventilateurs extérieurs de modèles VDVE900, VDVE1200
9. Pour réduire les risques d’incendie et de choc électrique, n’installez
cettehotte encastréequ’avec kitde recirculationsansconduit - ARKD.

16
PLANIFICATION
SPÉCIFICATIONS ÉLECTRIQUES
Modèle VDVI600 - Flex interne:
120 VCA • 60 Hz • 3,0 A
Modèles VDVE900, VDVE1200 - extérieurs:
120 VCA • 60 Hz • 6,0 A (max.)
PRISE DES MESURES
NEPASINSTALLERAVECUNAPPAREILDECUISSONCOMPORTANTUNEGRILLE.
En raison de sa polyvalence, ce système de hotte encastrée peut servir à
évacuer les contaminants aériens lorsque vous cuisinez avec une variété
d’appareils de cuisson au gaz ou à l’électricité - dont les surfaces de cuisson,
cuisinières, cuisinières coulissantes et cuisinières autonomes.
Elle peut être installée dans un îlot, une péninsule ou un mur ordinaire. Le
ventilateur (vendu séparément) et le boîtier électrique peuvent être xés à
la hotte encastrée, ou installés à l’intérieur d’une armoire ou à distance dans
un endroit pratique.
Cette unité s’installe facilement en suivant ces étapes de base :
• Découper l’ouverture dans le comptoir.
• Installer l’unité dans l’armoire.
• Installer le ventilateur et le boîtier électrique.
• Raccorder les conduits et le câblage électrique.
• Poser la bordure.
• Installer l’appareil de cuisson.
Remarque: le débit d’air élevé de cet appareil peut affecter la amme de
certains types de surface de cuisson au gaz. Ce phénomène est NORMAL
et ne causera aucun dommage mais il peut être corrigé en diminuant le
régime du ventilateur.
PLANIFICATION DE LA
POSE DES CONDUITS
1. Consulter les directives d’installation de la surface de cuisson pour les
dimensions de l’ouverture à découper dans le comptoir et les dimensions
de l’armoire. Toutefois, il est recommandé que l’armoire soit plus grande
que nécessaire pour faciliter l’installation.
2. La profondeur de lasurface de cuissonpeut varier grandement d’unproduit
à un autre. Il se peut que la pose de ces deux appareils soit relativement
serrée.
Porter une attention particulière aux nuisances possibles indiquées ci-dessous.
Un comptoir avec (A) une lèvre soulevée à l’avant ou (B) un dosseret risque de
ne laisser qu'une surface plane insufsante pour l’installation. Veuiller noter
que le comptoir doit comporter une partie plane de 7 cm (2-3/4 po) derrière
le plan de cuisson et qu’une distance de 7,3 cm (2-7/8 po) est nécessaire entre
le bord arrière du plan de cuisson et la paroi arrière intérieure de l’armoire.
1. Le système de hotte encastrée est conçu pour utiliser des
conduits ronds de 20,3 cm (8 po) avec un ventilateur Flex ou
des conduits ronds de 25,4cm (10po) avec un ventilateur
installé à distance. (Ventilateur vendu séparément.) Sept (7)
raccords de sortie sont disponibles- avec des possibilités
d’ajustement latéral pour un alignement précis du conduit:
A = 20,3 cm (8 po) rond, sortie à gauche, ventilateur Flex
B = 20,3 cm (8 po) rond, sortie à droite, ventilateur Flex
C = 20,3 cm (8 po) rond, sortie vers le bas, ventilateur Flex
(Le boîtier électrique doit être posé à distance)
D = 4,7 cm x 48,3 cm (1-7/8 po x 19 po), sortie à gauche du
boîtier vers le ventilateur ou ventilateur Flex à distance.
Utiliser une transition de 4,7 cm x 48,3 cm (1-7/8 po x
19 po) à 20,3cm (8 po) rond, oude 4,7cm x 48,3 cm
(1-7/8 po x 19 po) à 25,4cm (10po) rond, ou un conduit
de 4,7 cm x 48,3 cm (1-7/8 po x 19 po) selon lecas.
E = 4,7 cm x 48,3 cm (1-7/8 po x 19 po), sortie à droite du
boîtier vers le ventilateur ou ventilateur Flex à distance.
Utiliser une transition de 4,7 cm x 48,3 cm (1-7/8 po x
19 po) à 20,3 cm (8 po) rond, ou de 4,7cm x 48,3 cm
(1-7/8 po x 19 po) à 25,4cm (10po) rond, ou un conduit
de 4,7 cm x 48,3 cm (1-7/8 po x 19 po) selon lecas.
F = 4,7 cm x 48,3 cm (1-7/8 po x 19 po), sortie arrière du
boîtier vers le ventilateur ou ventilateur Flex à distance.
Utiliser une transition de 4,7 cm x 48,3 cm (1-7/8 po x
19 po) à 20,3 cm (8 po) rond, ou de 4,7cm x 48,3 cm
(1-7/8 po x 19 po) à 25,4cm (10po) rond, ou un conduit
de 4,7 cm x 48,3 cm (1-7/8 po x 19 po) selon lecas.
G = 4,7 cm x 48,3 cm (1-7/8 po x 19 po), sortie en dessous du
boîtier vers le ventilateur ou ventilateur Flex à distance.
Utiliser une transition de 4,7 cm x 48,3 cm (1-7/8 po x
19 po) à 20,3 cm (8 po) rond, ou de 4,7cm x 48,3 cm
(1-7/8 po x 19 po) à 25,4cm (10po) rond, ou un conduit
de 4,7 cm x 48,3 cm (1-7/8 po x 19 po) selon lecas.
2. Pour la meilleure performance: Choisir l’option qui permet
l’utilisationdes conduitsles pluscourts possibleet unnombre
minimumdecoudesetdetransitions.Vérierl’emplacementdes
solivesduplancher,desmontantsdesmurs,deslsélectriques
et de la plomberie pour éviter les nuisances éventuelles.
CONTENU
Ces pièces sont incluses avec le boîtier de hotte encastrée :
1 - Sac de pièces
1 - Ensemble de bordures
2 - Pieds de support
1 - Boîtier électrique
2 - Supports supérieurs
A
B
2-3/4 po
2-7/8 po
Hotte
Surface de cuisson
Avant à arrière
profondeur intérieure de l’armoire
Comptoir
Comptoir
AB
C
DE
F
HD1101
G
BOÎTIER
VENTILATEUR
FLEX
*
*Les ventilateurs installés à distance utilisent une plaque
de sortie pour conduits ronds de 20,3 cm (8 po) ou de
25,4cm (10 po) au lieu d’un ventilateur Flex.
BOÎTIER
ÉLECTRIQUE
Remarque: Enlevez la pellicule protectrice et les matériaux
d'emballage avant l'utilisation. Pour enlever la pellicule protectrice
et les matériaux d'emballage, soulevez le boîtier du ventilateur et
retirez le panneau avant pour accéder à la zone du ltre.

17
PLANIFICATION DU CÂBLAGE
1. Cette hotte encastrée utilisant un ventilateur Flex (vendu
séparément) consomme 3,0 A et exige un circuit de 120 VCA,
60Hz. Si un ventilateur est installé à distance (vendu séparément),
le système consomme 6,0 A et exige un circuit de 120 VCA, 60Hz.
2. La hotte comporte un cordon électrique de 45,7 cm (18 po) de
longueur muni d'une che à trois broches. Prévoir l’installation
d’une prise de courant permettant de brancher le cordon de
l’appareil.
3. Installer la boîte électrique conformément aux codes locaux.
4. La longueur du câble entre le boîtier électrique et la hotte est
de 50,8 cm (20 po).
5. La longueur du câble du ventilateur (vendu séparément) jusqu'au
boîtier électrique est de 1,5 m (5 pi).
PRÉPARATION DE LA HOTTE
ENCASTRÉE
PLANIFICATION DE LA
DÉCOUPE DU COMPTOIR
!
ATTENTION: AVANT DE DÉCOUPER L’OUVERTURE
DES CONDUITS DANS L’ARMOIRE, vérier que
les solives du plancher, les montants des murs,
lesls électriques et la plomberie ne présentent
aucunenuisance.
Utiliser les dimensions indiquées dans l’illustration ci-dessus pour
planier l’accès des conduits dans l’armoire. En règle générale, un
conduit rectangulaire de 4,8 cm x 48,3 cm (1-7/8 po x 19 po) est
utilisé au travers de la gauche, la droite, à travers le bas de l'armoire
et l’arrière de l’armoire- alors qu’un conduit rond de 20,3 cm (8 po)
est utilisé à travers le bas de l’armoire.
Pour une sortie à gauche, à droite ou à l’arrière:
Prévoir au moins 45,7 cm (18 po) pour la transition et le coude ou
le ventilateur.
Pour une sortie à gauche ou à droite:
Une armoire de 76,2 cm (30 po) de profondeur est recommandée
pour un alignement adéquat avec le ventilateur Flex. Le
ventilateur Flex peut être xé à la paroi arrièrede l’armoire ou à
une plateforme ou un cadre (non fourni) appuyé sur la base de
l’armoire. (Consulter les instructions du ventilateur Flex).
Une armoire de 61 à 76,2 cm (24 à 30 po) de profondeur est
nécessaire selon le type d’appareil de cuisson.
21 po
centré 4 po
21 po
24¾ po
FLUSH
5 po
/8
7
4 po
TROU POUR CONDUIT
DE 8 po OU 10 po ROND
(*Ajustable de 6 po à gauche et 6 po à dr
o
(Avec la plaque de sortie, l’ouverture e
s
ajustable de 6 po à gauche comme à dr
o
de la ligne de centre de l’installation)
1½ po**
6 po* 6 po*
** Si un ventilateur Flex
est installé, 1½ po à gauche
de la ligne de centre
de l’installation
LIGNE DE CENTRE
DE L’INSTALLATION
INTÉRIEUR DE
L’ARMOIRE -
ARRIÈRE
COIN ARRI
È
RE DE LA D
É
COUPE
DE LA SURFACE DE CUISSON
TROU POUR
CONDUIT ET
TRANSITIONS DE
17/8po x 19 po
PLANCHER
INTÉRIEUR
DE L’ARMOIRE
3. Couvrir les ouvertures d'éjection qui ne seront pas reliées aux
conduits.
Remarque: Utiliser les ÉCROUS retirés précédemment.
1. Placez la hotte encastrée sur le dos sur une table ou une
surface de travail plane.
2. Retirer les SUPPORTS DE FIXATION SUPÉRIEURS de la hote
en coupant les attaches autobloquantes. Enlever et mettre
de côté les PIEDS DE SUPPORT des côtés de la hotte (un
pied par côté).
Remarque: Se défaire des vis de retenue, mais GARDER LES
ÉCROUS.
Retirer l'ensembe des 3 COUVERCLES D'ÉJECTION du
dessous de la hotte.
COUVERCLES D'ÉJECTION
(RETIRER ET GARDER LES ÉCROUS)
SUPPORTS
SUPÉRIEURS
PIEDS DE SUPPORT
(GARDER L'ÉCROU,
JETER LES VIS)

18
Conduit installé à travers l’ouverture du panneau avant seulement:
1. Retirer les ÉCROUS HEXAGONAUX et les deux PROFILÉS
DE MONTAGE et les mettre de côté. Retirer le COUVERCLE
DU PANNEAU AVANT.
COUVERCLE DU
PANNEAU AVANT
PROFILÉS DE
MONTAGE
6 ÉCROUS
HEXAGONAUX
Installations avec VENTILATEUR FLEX seulement:
(Acheter un ventilateur Flex modèle VDVI600 séparément.)
Remarque: Retirez la plaque d'adaptation du ventilateur Flex
conformément aux instructions fournies avec le ventilateur.
2. Déterminer son emplacement sur le PANNEAU AVANT et si
la sortie se fera à gauche, à droite ou vers le bas.
UtiliserunecombinaisondePLAQUES DE RECOUVREMENT
de 7,6cm (3 po) ou de 15,2 cm (6 po) de largeur pour fermer
l’ouverture sur leou les côtés du ventilateur.
Glisser le ventilateur et les plaques de recouvrement entre le
PROFILÉINFÉRIEURetlesprolésdemontage.Serrezlesécrous
hexagonaux pour xer le ventilateur et les plaques en place.
PROFILÉ
INFÉRIEUR
PLAQUE DE
RECOUVREMENT PLAQUES DE
RECOUVREMENT
(incluses avec
le ventilateur)
VENTILATEUR
FLEX
PANNEAU
AVANT
Si la sortie
du ventilateur
est en bas, placer le boîtier
électrique ailleurs. Voir l’étape 5
.
Le boîtier électrique
peut être monté à distance.
PROFILÉS DE
MONTAGE
Installations avec VENTILATEUR FLEX (à distance) ou
VENTILATEUR À DISTANCE seulement:
3. Utiliser une PLAQUE DE SORTIE À DISTANCE et déterminer
son emplacement sur le PANNEAU AVANT.
Utiliserune combinaison de PLAQUES DE RECOUVREMENT
de 7,6 cm (3 po) ou de 15,2 cm (6 po) de largeur pour fermer
l’ouverture sur le ou les côtés de la plaque de sortie.
Glisser la plaque de sortie et les plaques de recouvrement
entrelePROFILÉ INFÉRIEURetles prolésdemontage.Serrez
les écrous hexagonaux pour xer les plaques en place.
PLAQUES DE
RECOUVREMENT
PLAQUE DE
RECOUVREMENT
PROFILÉ
INFÉRIEUR
PLAQUE DE SORTIE POUR
CONDUITS RONDS DE 20,3CM
(8 PO) OU DE 25,4 CM (10 PO)
(vendue séparément)
PANNEAU
AVANT
PROFILÉS DE
MONTAGE

19
SUPPORT
SUPÉRIEUR
COULISSE
PIED DE
SUPPORT
Ventilateur
Flex installé.
Toutes les installations:
4. Glisser les SUPPORTS SUPÉRIEURS dans la COULISSE en
haut à gauche et à droite de l’unité.
Fixez les PIEDS DE SUPPORT au bas de l’unité sur les côtés à
l’aide d'un ÉCROU HEXAGONAL pour chaque pied. Ne pas
serrer complètement ces écrous à cette étape-ci.
Installations dans lesquelles le BOÎTIER ÉLECTRIQUE doit
être monté à distance seulement:
5.
Enlever les (4) ÉCROUS HEXAGONAUX et le BOÎTIER
ÉLECTRIQUE. Des câbles de rallonge de 1,5 m (5 pi) (vendus
séparément) peuvent être nécessaires pour monter le boîtier
électrique à distance. Ne pas utiliser plus de deux câbles de
rallonge. Ne pas monter le panneau électrique avec les trous
d'aération vers le bas
.
18-3/16 po (46,2 cm)
17-7/16 po (44,3 cm) Centre des fentes
4-1/2 po
(11,4 cm)
Centre
des fentes
6-1/4 po
(15,9 cm)
16-1/4 po (15,9 cm)
6-5/8 po
(16,8 cm)
Dimensions du boîtier électrique

20
PIEDS DE
SUPPORT DU
VENTILATEUR
Installations avec VENTILATEUR FLEX seulement:
6. Fixer les PIEDS DE SUPPORT DU VENTILATEUR à l’aide
des (4) BOULONS fournis.
(4) BOULONS
ATTENTION: Si le ventilateur Flex doit être monté
à distance: Ne pas utiliser seulement les pieds
comme supports. Il peut être nécessaire d’ajouter
d’autres supports au ventilateur. Utiliser les
supports de montage fournis avec le ventilateur.
!
Installations avec conduit à gauche, à droite, en dessous ou à
l’arrière seulement:
(Exige l’achat d’un conduit de transition de 4,8 cm x 48,3 cm
[1-7/8po x 19 po] à 20,3 cm ou 25,4 cm [8 po ou 10 po] rond
ou d'un adaptateur de 4,8 cm x 48,3 cm [1-7/8po x 19 po] et
la coupe du conduit de 4,8 cm x 48,3 cm [1-7/8 po x 19 po] à
la longueur voulue.)
7. Utiliser des écrous pour attacher l'adaptateur de conduit
de 4,8 cm x 48,3 cm (1-7/8po x 19 po) ou la transition de
4,8 cm x 48,3 cm (1-7/8po x 19 po) à 20,3 cm ou 25,4 cm
[8 po ou10 po] rond au boîtier lors de la pose du conduit.
DÉCOUPER L’OUVERTURE
DU COMPTOIR
1. Tracer et découper l’ouverture de la surface de cuisson
sufsamment vers l’AVANT de sorte que la hotte puisse s’encastrer
derrière.
2. Disposer la surface de cuisson en place et la glisser le plus possible
vers l’avant sans qu’aucun écart ne soit visible. La centrer et vérier
son équerre avec les bords du comptoir.
3. Placer le gabarit en plastique contre la bordure arrière de la surface
de cuisson ou contre le bord arrière de l’ouverture de la cuisinière
encastrable. Centrer le gabarit. Tracer le pourtour du gabarit pour
marquer l’ouverture de la hotte encastrée.
4. Retirer la surface de cuisson du comptoir.
5. Découper l’ouverture de la hotte. Prendre garde de ne pas abîmer
les bords du comptoir.
Gabarit contre le bord arrière
du comptoir.
SURFACE DE
CUISSON
Other manuals for 5 Series VGC
20
This manual suits for next models
4
Table of contents
Languages:
Other Viking Range Fan manuals

Viking Range
Viking Range DEV15001 User manual

Viking Range
Viking Range VDD5300 Technical manual

Viking Range
Viking Range VIPR101SS User manual

Viking Range
Viking Range RVDD330R User manual

Viking Range
Viking Range VIPR102 User manual

Viking Range
Viking Range VDVI600 User manual

Viking Range
Viking Range VINV1200 User manual

Viking Range
Viking Range VDVE900 User manual

Viking Range
Viking Range RDIPR101R User manual

Viking Range
Viking Range CVDD5300 Technical manual