Built-In Information
• A minimum of 6” (15.2 cm) from the si es,
or a minimum of 8” (20.3 cm) from the
right si e if there is a rotisserie motor an
a minimum of 24” (61.0 cm) from the back
must be maintaine from the grill above
the cooking surface to a jacent vertical
combustible construction. The grill is not
to be locate un er overhea unprotecte
combustible construction.
• A minimum of 3” (7.6 cm) clearance from
the back of the grill with a canopy an a
minimum of 6” (15.2 cm) from the back of
the grill without a canopy to non-
combustible construction is require for
the purpose of allowing the li to open
fully an for proper ventilation.
• Note that the grill exhausts combustion
pro ucts an cooking greases to the back.
Never locate the grill in a location where
the exhaust is irecte at a win ow, less
than 24” (61.0 cm) to combustible material
or any surface that is ifficult to clean.
• It is esirable to allow at least 6” si e
clearance to non-combustible construction
above the cooking surface for counter
space. If using the rotisserie option, the
space is essential for motor an skewer
clearance. The grill can be place irectly
a jacent to combustible an /or non-
combustible construction below the
cooking surface.
• When etermining a suitable location for
the grill, take into account concerns such
as exposure to win , proximity to traffic
paths an keeping gas supply lines as
short as possible. Locate the grill only in a
well-ventilate area. Never locate the grill
in a buil ing, garage, she or other such
fully enclose areas. During heavy use, the
grill will pro uce a lot of smoke. Ensure
there is a equate area for it to issipate.
T-Series Grills:
• When using a rear wall, locate the
electrical service on the right han si e for
the rotisserie motor. The rotisserie motor
requires a 110/120 volt supply. The power
supply cor on the motor is equippe with
a 3-prong (groun e ) plug for protection
against shock hazar . Do not cut or
remove the groun ing from the plug. The
electrical service must be equippe with a
properly groun e 3-prong receptacle as
require by the National Electrical Co e
ANSI/NFPA 70-latest e ition. Installation in
Cana a must be in accor ance with the
Cana ian Electrical Co e, CSA 22.1 an
local co es.
E-Series Grills:
• When using a rear wall, locate a 110/120
volt supply outlet on the bottom left han
si e beneath the soli bottom support at a
maximum istance of 2 feet. This
connection is to be use for the ignition
system an canopy lights. In a ition, the
rotisserie motor requires a separate
110/120 volt supply to be locate on the
right han si e of the grill. Both the power
supply cor s for the ignition/lights an the
rotisserie motor are equippe with a 3-
prong (groun e ) plug for protection
against shock hazar . Do not cut or
remove the groun ing from the plug. The
electrical service must be equippe with a
properly groun e 3-prong receptacle as
require by the National Electrical Co e
ANSI/NFPA 70-latest e ition. Installation in
Cana a must be in accor ance with the
Cana ian Electrical Co e, CSA 22.1 an
local co es.
IMPORTANT: Gas ittings, regulator, and
installer supplied shut-o valve must be
easily accessible.
1312
General Information
• Keep grill area clear an free from
combustible materials, gasoline, an other
flammable vapors.
• When the out oor grill is not in use, the
gas supply must be turne off at the LP
gas supply cylin er.
• The pressure regulator an hose assembly
supplie with the out oor grill must be
use . Replacement pressure regulators an
hose assemblies must be those specifie
by the manufacturer.
• Fin ing a leak is not a “ o-it-yourself”
proce ure. Some leaks can only be foun
with the burner control in the on position
an this must be one by a qualifie
technician.
• The LP supply cylin er to be use must be
constructe an marke in accor ance
with the specifications for LP- gas cylin ers
of the U.S. Department of Transportation
(DOT) or the National Stan ar of Cana a,
CAN/CSA- B339, Cylin ers, Spheres, an
Tubes for the Transportation of Dangerous
Goo s.
• Use only extension cor s with a 3-prong
groun ing plug, rate for the power of the
equipment, an approve for out oor use
with a W-A marking.
• Gas Manifol Pressure–
Natural gas - 4.0” W.C.P.
LP/Propane - 10.0” W.C.P.