manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Vive
  6. •
  7. Thermometer
  8. •
  9. Vive DMD1024GRY User manual

Vive DMD1024GRY User manual

PRODUCT DESCRIPTION
With the Vive Precision oral thermometer, taking your temperature has
never been easier. Simply activate the thermometer, place it under
the tongue, and see your temperature displayed in bold font on a
large, easy-read LCD screen. Each device has been rigorously tested
for accuracy. Features an energy-saving automatic shut off function,
and displays temperature in both Celsius and Fahrenheit. Protected
by a one-year warranty.
WHAT’S INCLUDED
• 1x Oral Thermometer
• 1x Plastic Protective Cover
• 1-Year Warranty
WARNING
• Read instructions thoroughly before using digital thermometer
• Choking Hazard: Thermometer cap and battery may be fatal if
swallowed. Do not allow children to use this device without parental
supervision.
• Do not use thermometer in ear. Designed use is for oral, rectal, and
armpit (axilla) readings only.
• Do not place thermometer battery near extreme heat as it may
explode.
• Use of the probe cover may result in a 0.1 °C (0.2°F) discrepancy
from actual temperature.
• It is recommended the performance should be checked every two
years.
• Remove battery from the device when is not operation for a long
time.
• The performance of thermometer may be degraded if one or
more of the following occur:
(a) Operation outside stated temperature and humidity range;
(b) Storage outside stated temperature and humidity range;
(c) Mechanical shock
(d) Patient temperature is below ambient temperature
• Do not bend or drop thermometer. It is not shockproof.
• Do not boil probe to disinfect
• Do not store in direct sunlight or in areas of extreme heat
• Do not disassemble. See BATTERY REPLACMENT to replace battery. Do
not put in trash. Recycle or manage as hazardous waste. Battery
contains mercury.
• Avoid strong electromagnetic interference such as microwave
ovens and cell phones.
HOW TO CHANGE BETWEEN CELSIUS AND FAHRENHEIT
Temperature readings are available in the Fahrenheit or Celsius
scale (°C/°F, located in the upper right corner of LCD.) With the unit
off, press and hold the On/Off Button for approximately 4 seconds to
change the current settings.
OPERATING INSTRUCTIONS
1. Wipe or dip thermometer probe with isopropyl rubbing alcohol to
disinfect.
2. Press the On/Off Button next to LCD display. A tone will sound as
the screen shows ‘ ‘ followed by the last record temperature.
After showing the self-test temperature, the thermometer is now in
the testing mode.
Note: If the measured temperature is less than 32°C or 90°F, the LCD
will display Lo, if the measured temperature is higher that 42.9°C or
109.9°F, the LCD will display Hi.
3. Position thermometer in desired location (mouth, rectum, or
armpit)
(a.) Oral Use: Place thermometer under
tongue as indicated by “check
sign” position shown in Figure 1
Close your mouth and
breathe evenly through the nose
to prevent the measurement from
being inuenced by inhaled/
exhaled air. Normal temperature
between 35.7°C and 37.3°C (96.3°F and 99.1°F)
(b.) Rectal Use: Lubricate silver probe tip with petroleum jelly for
easy insertion. Gently insert sensor approximately 1 cm (less
than 1/2”) in rectum. Normal temperature between 36.2°C
and 37.7°C (97.2°F and 99.9°F)
(c.) Armpit Use: Wipe armpit dry. Place probe in armpit and keep
arm pressed rmly at side. From a medical viewpoint, this
method will always provided inaccurate readings, and should
not be used if precise measurements are required. Normal
temperature between 35.2°C and 36.7°C (95.4°F and 98.1°F)
4. The degrees sign ashes throughout the testing process. When
ashing stops an alarm will beep for approximately 10 seconds.
The measured reading will appear on the LCD simultaneously.
The displayed temperature will not change when thermometer is
removed from its testing position.
Note: Normally the buzzes are “Bi-Bi-Bi-Bi”; Alarm beeps more rapidly
when temperature reaches 37.8°C (100°F) or higher, and the buzzes
are “Bi-Bi-Bi----- Bi-Bi-Bi----- Bi-Bi-Bi”
LCD Battery Cap
ON/OFF Button
Probe
E
M
,
Figure 1
5. To prolong battery life, press the On/Off Button to turn unit off after
testing is complete. If no action is taken, the unit will automatically
shut off after around 10 minutes.
BATTERY REPLACEMENT
1. Replace battery when “ ” appears in the lower right corner
of LCD display.
2. Pull battery cover off as shown in Figure 2.
3. Use pointed object such as pen to remove old battery. Discard
batter lawfully. Replace with new 1.5 DC button type LR41 or SR41,
UCC392, or equivalent. Be sure battery is installed with “+” polarity
facing up. (See gure 3,4)
4. Slide battery chamber back into place and attach cover.
CLEANING & DISINFECTING
The best way to clean the thermometer tip is by applying a
disinfectant (e.g. 70% ethyl alcohol) with a damp cloth. The
waterproof thermometer can be immersed in liquid or lukewarm
water for thorough cleaning and disinfection.
PRODUCT DISPOSAL
Please ensure environmental protection. Batteries do not
belong in the domestic waste. Please hand them in at
collection point or the municipal recycle material center as
special waste.
This symbol on products and/or accompanying documents
means that consumed electronic products must not be mixed with
conventional domestic waste.
Take these products to the corresponding collection points for correct
treatment and recycling, where they will be accepted free of charge.
For more information on the closest collection point, Please enquire
with your local authorities.
LEGAL REQUIREMENTS & GUIDELINES
This thermometer is manufactured according to the system of
EN12470-3:2000+A1:2009, ASTME1112-00. This thermometer complies
with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this thermometer may not cause harmful interference,
and (2) this thermometer must accept any interference received
including interference that may cause undesired operation. And the
manufacturer is ISO 9001: 2008 and ISO 13485:2003 + AC: 2007
certied.
SPECIFICATIONS
• Waterproof and exible features for using conveniently
• Range: 32.0°C – 42.9°C (90.0°C – 109.9°F)
• Accuracy: ±0.1 °C, 35.5°C –42.0°C (±0.2°F, 95.9°F-107.6°F)
±0.2°C under 3.5°C or over 42.0°C
(±0.4°F under 95.9°F or over 107.6°F)
at standard room temperature of 18°C to 28°C
(64.4°F to 82.4°F)
• Display: Liquid crystal display, 3 1/2 digits
• Memory: For storing the last measured value
• Battery: One 1.5V DC. Button battery (size LR41 OR SR41, UCC392)
• Battery Life: Approx 200 hours
• Dimension: 13.9cm x 2.2cm x 1.3 cm (L x W x H)
• Weight: Approx 11.0 grams including battery
• Using Environment
Temperature: 5°C ~ 40°C (41°F ~ 104°F)
Relatively humidity: <85%RH
• Storage and transportation condition
Temperature: -10°C ~ 55°C (14°F ~ 131°F)
Relatively humidity: <95%RH)
• Waterproof level: Waterproof
• Classication: TYPE B
ACTIVATE YOUR GUARANTEE
This product is guaranteed to be free from manufacturing defects.
We will replace or exchange any product that is defective to your
complete satisfaction. This warranty extends one year from the
purchase date, as long as the product has not been misused or
abused.
© Copyright and Distributed by Vive Health
8955 Fontana Del Sol Way, Naples, FL 34109
All Rights Reserved. Made in China.
Email: [email protected]
Figure 2 Figure 3 Figure 4
To ensure your warranty,
please register your product at
www.vivehealth.com/register.
Product Code: DMD1024GRY

Other Vive Thermometer manuals

Vive DMD1010 User manual

Vive

Vive DMD1010 User manual

Vive DMD1026GRY User manual

Vive

Vive DMD1026GRY User manual

Popular Thermometer manuals by other brands

RS 53 II Operator's manual

RS

RS 53 II Operator's manual

Braun ThermoScan IRT 4520 manual

Braun

Braun ThermoScan IRT 4520 manual

nantlife TE4.0 user manual

nantlife

nantlife TE4.0 user manual

Welch Allyn CareTemp Touch Free Directions for use

Welch Allyn

Welch Allyn CareTemp Touch Free Directions for use

Hama TH-100 operating instructions

Hama

Hama TH-100 operating instructions

LKM DTM 3000 operating instructions

LKM

LKM DTM 3000 operating instructions

Rossmax RA600 manual

Rossmax

Rossmax RA600 manual

AEG FT 4904 manual

AEG

AEG FT 4904 manual

Sealey VS900.V4 instructions

Sealey

Sealey VS900.V4 instructions

TFA 30.3034 instruction manual

TFA

TFA 30.3034 instruction manual

Maverick Industries ET-72 REDI CHEK user manual

Maverick Industries

Maverick Industries ET-72 REDI CHEK user manual

Velleman DVM8855 user manual

Velleman

Velleman DVM8855 user manual

Gima 25562 quick start guide

Gima

Gima 25562 quick start guide

Safire SF-HANHELD-160T05E user manual

Safire

Safire SF-HANHELD-160T05E user manual

Braun ThermoScan IRT 1020 use instructions

Braun

Braun ThermoScan IRT 1020 use instructions

Fluke Hart Scientific 1575 Super-Thermometer user guide

Fluke

Fluke Hart Scientific 1575 Super-Thermometer user guide

Digoo DG-TH1180 operating instructions

Digoo

Digoo DG-TH1180 operating instructions

ident-a-kid Temp Chek Plus Assembly instructions

ident-a-kid

ident-a-kid Temp Chek Plus Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.