4
Installation Procedure
Installation – RAIL66 version
Prior to installing the luminaire, mount and connect
the selected RAIL66 mounting system in accordance
with relevant installation instructions
1) Switch off mains electrical supply.
2) Check that rating shown on luminaire label conforms
with mains electrical supply.
3) Determine desired position of luminaire Aon rail X,
dependent on aiming requirements and proximity
to a suitable mains outlet Y.
4) Attach clamp Bto rail X. Tighten wingnut C.
5) Remove protective cover Zfrom mains outlet Y.
Insert in-line connector Gand tighten.
Attention: On any mains outlet Y’ that is not used,
protective cover Z’ must remain Ƃrmly secured.
Check and ensure proper Ƃt and tightness.
6) Loosen screws Hand Islightly. Aim luminaire in
desired direction, tighten screws Hand I. Tighten
set screw O.
Installation – Space frame version
Suitable for space frame diameter 48-60 mm.
1) Switch off mains electrical supply.
2) Determine desired position of luminaire Aon space
frame X, dependent on aiming requirements.
3) Attach clamp Bto space frame X. Tighten
wingnut C.
4) Detach gear box cover Dby loosening screws S.
5) Check that rating shown on luminaire label conforms
with mains electrical supply.
6) Feed mains supply cable Fthrough cable gland G
(Fig. I).
7) Connect mains supply leads to respective terminals
in terminal connector J(N = Neutral, L1 = Phase,
= Earthing). Tighten cable gland G.
For 1-10 V analogue dimming interface, connect
main supply leads to respective terminals in termi-
nal connector J(N = Neutral, L= Phase,
= Earthing) and (D+, D– = external 1-10 V dim-
ming device). See Fig. II. Tighten cable gland G.
8) Reposition gear box cover Dand secure in position
by tighten screws S.
9) Loosen screws Hand Islightly. Aim luminaire in
desired direction, tighten screws Hand I. Tighten
set screw O.