V SILVA BULA BD WA1250...1600
Gramatura: 60g
Material: Papel Normal
FABIO
000 00
E
SOCRATES
20/07/09
10000779984
FRENTE
VERSO
DOBRAS
DIMENSIONAL
1ª DOBRA
3ª DOBRA
2ª DOBRA
- PARA VERIFICAÇÃO DE DADOS
UTILIZAR ARQUIVOS PARA IMPRESSÃO,
CONFORME PÁGINAS SEGUINTES.
-IMPRESSÃO: PRETO E BRANCO COM
ESCALA EM CINZA
-O DOCUMENTO DEVE SER DOBRADO
PELO FORNECEDOR.
-PARA IMPRESSÃO UTILIZAR ARQUIVOS
PARA IMPRESSÃO, CONFORME PÁGINAS
SEGUINTES.
210
297
Retirar la tapa de accesorios del interruptor
quitando sus 2 tornillos.
Montar la bobina de disparo (B.D), en la
cavidad interna de la tapa, en el alojamiento
correspondiente (fase R), colocarla hasta
que quede totalmente insertada.
Colocar el tornillo (A) de fijación del
accesorio.
Verificar que el accionador (B) de la (B.D),
actúe encima de la leva de disparo (C) (segun
detalle 1).
Realizar la salida de los cables por la ranura
existente en la tapa de accesorios.
Colocar la tapa de accesorios con sus 2
tornillos y verificar su correcto
funcionamiento.
Verificar que en la posición abierto del
interruptor, el contacto móvil (D) accione el
fin de curso (E) de la (B.D).
Alimentar la (B.D) con la tensión nominal
correspondiente, verificando la apertura del
interruptor, y que el contacto de fin de curso
(E) desconecte la alimentación
Retirar a tampa de acessorios do disjuntor
soltando os 2 parafusos de fixação.
Montar a bobina de disparo (B.D), no
alojamento correspondente (fase R).
Coloca-lha até que fique totalmente inserida.
Colocar o parafuso (A) de fixação do
acessorio.
Verificar que o acionador (B) da (B.D), atue
acima da came de disparo (C) (segundo o
detalhe 1).
Verificar na posição aberto do disjuntor, que
o contato movil (D) deve acionar o fim de
curso (E) da (B.D).
Fazer a saida dos cabos, na ranhura
existente na tampa de acessorios do
disjuntor.
Colocar a tampa de acessorios do disjuntor,
fixando os 2 parafusos, e verificar seu
correto funcionamento.
Ligar a (B.D) com a tensão nominal
correspondente, verificando a abertura do
disjuntor, e que o contato de fim de curso (E)
desligue a alimentação.
.
1-
2-
3-
4-
5-
6-
7-
BD DWA1250...1600
Bobina de disparo
1-
2-
3-
4-
5-
6-
BD DWA1250...1600
Bobina de disparo
BD DWA1250...1600
Shunt Trip Release
Remove the cover of accessories of the
Circuit-Breaker taking away its 2 fixation
screws.
Assemble the Shunt Trip Release (B.D)) in
the internal cavity of the cover, in its
corresponding location (phase R). Place it
until it be totally inserted.
Place the screw (A) fixing the accessory.
Verify that the activator (B) of the Shunt Trip
works above the trigger cam (C) (according
to detail 1).
Verify that in the opening position of the
Circuit-Breaker, the movil contact (D) must
activate the limit switch (E) of the Shunt Trip
(B.D).
Make the cables output through the groove
on the accessories cover.
Place the cover of accessories, fixing the 2
closing screws, verifying the correct
functioning.
Provide the energy to the Shunt Trip (B.D)
with the corresponding nominal voltage,
verifying the opening of the Circuit-Breaker,
and that the limit switch contact (E)
disconnects the power supply.
1-
2-
3-
4-
5-
6-
7-
D
E
C
B
A
7-
8- 8- 8-
Test
Teste
Detalle 1
Detalhe 1
Detail 1
DWA
DWM1250...1600
DWG1250...1600
IWA1250...1600
1250...1600
Instrucciones de Montaje
Instruções de Montagem
Assembly Instructions
WEG Automação
www.weg.net
10000779984.00

This manual suits for next models

7

Other WEG Other manuals

WEG AM DWA400 User manual

WEG

WEG AM DWA400 User manual

WEG DWA-160 User manual

WEG

WEG DWA-160 User manual

WEG DWA 1250 User manual

WEG

WEG DWA 1250 User manual

WEG BC DWA160 User manual

WEG

WEG BC DWA160 User manual

WEG DWM160L User manual

WEG

WEG DWM160L User manual

WEG DWA1250 User manual

WEG

WEG DWA1250 User manual

WEG DWB160 User manual

WEG

WEG DWB160 User manual

WEG AL DWA160 User manual

WEG

WEG AL DWA160 User manual

Popular Other manuals by other brands

CoolGear USBG-410B user manual

CoolGear

CoolGear USBG-410B user manual

ALLPOWER APG3201 owner's manual

ALLPOWER

ALLPOWER APG3201 owner's manual

Aqua Medic Ozone 25 Operation manual

Aqua Medic

Aqua Medic Ozone 25 Operation manual

Think Safe Euro 100.3 user manual

Think Safe

Think Safe Euro 100.3 user manual

Aqua Medic reactor 1000 Operation manual

Aqua Medic

Aqua Medic reactor 1000 Operation manual

Delta OHM HD33[L]M.GSM operating manual

Delta OHM

Delta OHM HD33[L]M.GSM operating manual

Siemens 8DA series operating instructions

Siemens

Siemens 8DA series operating instructions

Butler HP441S.XX Series instruction manual

Butler

Butler HP441S.XX Series instruction manual

Onset Hobo U12 manual

Onset

Onset Hobo U12 manual

YILMAZ CA 601 manual

YILMAZ

YILMAZ CA 601 manual

Advantech PWS 472 user manual

Advantech

Advantech PWS 472 user manual

CAME G4040E manual

CAME

CAME G4040E manual

FXGear NOON VR PLUS Quick start manual

FXGear

FXGear NOON VR PLUS Quick start manual

Kenwood KDC-X979 instruction manual

Kenwood

Kenwood KDC-X979 instruction manual

Rubicon Express RE6300 installation instructions

Rubicon Express

Rubicon Express RE6300 installation instructions

HEIDENHAIN ND 7000 operating instructions

HEIDENHAIN

HEIDENHAIN ND 7000 operating instructions

curt Q20 Installation instructions and operators manual

curt

curt Q20 Installation instructions and operators manual

AquaCare Turbo Chalk Reactor Control II instruction manual

AquaCare

AquaCare Turbo Chalk Reactor Control II instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.