manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. weintek
  6. •
  7. Touch Panel
  8. •
  9. weintek MT8092XE Series User manual

weintek MT8092XE Series User manual

Installation and Startup Guide
This document covers the installation of MT8090/8091/8092XE Series HMI, for the detailed
specifications and operation, please refer to Brochure and EasyBuilder Pro User Manual.
Install Environment:
NEMA Rating
MT8090/8091/8092XE Series HMI is NEMA 4 rated.
Electrical
Environment
MT8090/8091/8092XE Series has been tested to conform to European CE
requirements. This means that the circuitry is designed to resist the effects of
electrical noise. This does not guarantee noise immunity in severe cases. Proper
wire routing and grounding will insure proper operation.
Environmental
Considerations
(1) Make sure that the displays are installed correctly and that the operating
limits are followed. Avoid installing units in environments where severe
mechanical vibration or shocks are present.
(2) Do not operate the unit in areas subject to explosion hazards due to
flammable gases, vapors or dusts.
(3) Do not install the unit where acid gas, such as SO2 exists.
(4) This device should be mounted in the vertical position and for use on the flat
surface enclosure.
(5) Conform to UL508 (ISBN 0-7629-0404-6) machine safety for use in
Pollution Degree 2 Environment.
Unpacking the Unit
Unpack and check the delivery. If damage is found,
notify the supplier.
The packing box can be transformed into an HMI stand. Please follow the steps to make the stand.
1. Remove the center of the box cover along the perforated line.
2. Pull the two inner flaps.
3. Press down along the perforated line inside the box.
4. Complete the stand as shown.
Installation Instructions
Secure the operator panel in position, using all the fastening holes and the provided brackets
and screws:
Type
A(mm)
B(mm)
MT8090XE
248.5
191
MT8091XE
248.5
191
MT8092XE
248.5
191
Power Connections
NOTE:
1. Connect positive DC line to the ‘+’ terminal and
the DC ground to the ‘-’ terminal.
2. Please do not connect HMI with PLC and PC
simultaneously to prevent potential difference
from destroying USB ports of HMI and PC.
System Settings
MT8092XE:
When HMI is powered up and displays image, press the
system setting button in the lower-right corner of the screen.
(Default System Password: 111111)
Go to the Network tab, you may choose to auto get DHCP IP,
or designate your own IP.
MT8092XE has two10/100/1000 Base-T Ethernet ports.
The default IP addresses are:
LAN 1: DHCP
LAN 2: 192.168.100.1
MT8090/8091/8092XE series
Installation Instruction
1
2
NOTE:
Place the operator panel on a stable
surface during installation. Dropping it or
letting it fall may cause damage.
(1) Installation Instruction, 2-sided A4 *1
(2) Human Machine Interface *1
(3) Power Connector *1
(4) Brackets & Screws *1 pack
(5) Fuse 1.25A/250V 5*20mm *1
3
5
4
(1)
(2)
(3)
(5)
(4)
(A)
(B)
Cutout
MT8090/8091XE:
When HMI is powered up and displays image,
press the system setting button.
(Default System Password: 111111)
It is necessary to connect the HMI to
your network through a RJ-45 cable.
EasyBuilder Pro Software Settings
Launch EasyBuilder Pro software, select your project file,
press F7 shortcut key to open the download dialog box:
Select Ethernet > IP tab > Enter your HMI IP > Click
Download to download this project file to HMI.
( Please refer to EasyBuilder Pro User Manual
for software operation details )
Communication Connections
Con.B: Con.A:
COM1/3 [RS232] 9 Pin, Male, D-sub COM2/3 [RS485] / CAN Bus 9 Pin, Female, D-sub
Calibration Mode
To enter touch screen calibration mode, press and hold anywhere on the screen for more than 2
seconds when HMI starts.
PIN#
COM1 [RS232]
COM3 [RS232]
(MT8092XE only)
1
2
RxD
3
TxD
4
5
GND
6
7
RTS
TxD
8
CTS
RxD
9
PIN#
COM2 [RS485]
COM3
[RS485]
CAN
Bus
2W
4W
1
Data-
Rx-
2
Data+
Rx+
3
Tx-
4
Tx+
5
GND
6
Data-
7
CAN_L
8
CAN_H
9
Data+
*CAN Bus is not applicable for MT8090XE1 model.
NOTE:
1. COM2 and COM3 [RS485] 2W support MPI 187.5K, please use one at one time.
2. COM1 RS-232 RTS/CTS and COM3 RS-232 cannot be used simultaneously.
Go to the Network tab, you may choose
to auto get DHCP IP, or designate your
own IP.
6
7
8
Limited Warranty
This product is limited warranted against defects in design and manufacture.
The proven defective product will either be repaired or replaced, at Weintek’s discretion.
This warranty shall not cover any product which is
(a) Out of warranty period which is 12 months from the manufacturing month of the HMI products.
(b) Damage caused by Force Majeure, accident, negligence, improper installation or misuse.
(c) Product has been repaired or taken apart by unauthorized technicians.
(d) Products whose identification markings have been removed or damaged.
Power
The unit can be powered by DC power only, voltage range: 24±20% Volts DC, compatible with
most controller DC systems. The power conditioning circuitry inside the unit is accomplished by a
switching power supply. The peak starting current can be as high as 2A.
Fusing
Require-
ments
If the display does not come on within 5 seconds of power up, remove power. An internal fuse will
prevent damage if the polarity of the DC power is incorrect. Check wiring for proper connections
and try to power up again.
High
Voltage
An Internal fuse will prevent damage for overcurrent condition however it isn’t guaranteed. DC
voltage sources should provide proper isolation from main AC power and similar hazards.
Emergency
Stop
A Hard-wired EMERGENCY STOP should be fitted in any system using HMI to comply with ICS
Safety Recommendations.
Supply
Voltage
Condition
Do not power the unit and inductive DC loads, or input circuitry to the controller, with the same
power supply. Note: The 24 VDC output from some controllers may not have enough current to
power the unit.
Wire
Routing
a. Power wire length should be minimized (Max: 500m shielded, 300m unshielded).
b. Please use twisted pair cables for power wire and signal wire and conform to the impedance
matching.
c. If wiring is to be exposed to lightning or surges, use appropriate surge suppression devices.
d. Keep AC, high energy, and rapidly switching DC power wiring separated from signal wires.
e. Add a resistor and capacitor in the parallel connection between the ungrounded DC power
supply and the frame ground. This provides a path for static and high frequency dissipation.
Typical values to use are 1M Ohm and 4700pF.
CAUTION
NOTE:
Make sure that all local and national electrical standards are met when
installing the unit. Contact your local authorities to determine which codes apply.
Hardware
Considerations
The system designer should be aware that devices in Controller systems could fail and thereby
create an unsafe condition. Furthermore, electrical interference in an operator interface can lead to
equipment start-up, which could result in property damage and/or physical injury to the operator.
If you use any programmable control systems that require an operator, be aware that this potential
safety hazard exists and take appropriate precautions. Although the specific design steps depend on
your particular application, the following precautions generally apply to installation of solid-state
programmable control devices, and conform to the guidelines for installation of Controllers
recommended in NEMA ICS 3-304 Control Standards.
Programming
Considerations
To conform with ICS Safety Recommendations, checks should be placed in the controller to ensure
that all writable registers that control critical parts of plant or machinery have limit checks built into
the program, with an out-of-limit safe shut down procedure to ensure safety of personnel.
GME8090X2_MT8090_8091_8092XE1_Installation_150708
DANGER

This manual suits for next models

2

Other weintek Touch Panel manuals

weintek MT6050iP User manual

weintek

weintek MT6050iP User manual

weintek NP-610p Series Installation manual

weintek

weintek NP-610p Series Installation manual

weintek MT8091XE Series User manual

weintek

weintek MT8091XE Series User manual

weintek NP-700p Series Installation manual

weintek

weintek NP-700p Series Installation manual

weintek cMT3000 Series User manual

weintek

weintek cMT3000 Series User manual

weintek MT605i User manual

weintek

weintek MT605i User manual

weintek MT-6056i User manual

weintek

weintek MT-6056i User manual

weintek MT-600 Series User manual

weintek

weintek MT-600 Series User manual

weintek MT607i User manual

weintek

weintek MT607i User manual

weintek MT-8070iH User manual

weintek

weintek MT-8070iH User manual

weintek i Series Installation guide

weintek

weintek i Series Installation guide

weintek MT6051iP Series User manual

weintek

weintek MT6051iP Series User manual

weintek EasyView MT-608S User manual

weintek

weintek EasyView MT-608S User manual

weintek cMT-iM21 series User manual

weintek

weintek cMT-iM21 series User manual

weintek MT8121XE Series User manual

weintek

weintek MT8121XE Series User manual

weintek cMT-iV5 series User manual

weintek

weintek cMT-iV5 series User manual

weintek eMT Series User manual

weintek

weintek eMT Series User manual

weintek MT-6070iH3 Series User manual

weintek

weintek MT-6070iH3 Series User manual

weintek MT8050iE series User manual

weintek

weintek MT8050iE series User manual

weintek eMT3000 Series User manual

weintek

weintek eMT3000 Series User manual

weintek cMT-iPC15 User manual

weintek

weintek cMT-iPC15 User manual

weintek MT8102iP series Service manual

weintek

weintek MT8102iP series Service manual

weintek MT-8150X User manual

weintek

weintek MT-8150X User manual

weintek MT8102iP series User manual

weintek

weintek MT8102iP series User manual

Popular Touch Panel manuals by other brands

Crestron Isys TPS-4000L Operation guide

Crestron

Crestron Isys TPS-4000L Operation guide

AMX MVP-5200i-GB instruction manual

AMX

AMX MVP-5200i-GB instruction manual

Winmate R15IB3S-PCC3-PoE quick start guide

Winmate

Winmate R15IB3S-PCC3-PoE quick start guide

Elegoo 3.5" TFT user manual

Elegoo

Elegoo 3.5" TFT user manual

Kontron XtremeClient-KLU user guide

Kontron

Kontron XtremeClient-KLU user guide

IEI Technology AFL4-W10-EHL user manual

IEI Technology

IEI Technology AFL4-W10-EHL user manual

Beijer Electronics T15BR installation manual

Beijer Electronics

Beijer Electronics T15BR installation manual

AMX MVP-9000i-GB instruction manual

AMX

AMX MVP-9000i-GB instruction manual

Bosch rexroth IndraControl PR4100 manual

Bosch

Bosch rexroth IndraControl PR4100 manual

MR MESSKO MTO Technical data

MR

MR MESSKO MTO Technical data

AMX AXT-CM Dimensional drawing

AMX

AMX AXT-CM Dimensional drawing

Winmate IP69K Stainless P-Cap user manual

Winmate

Winmate IP69K Stainless P-Cap user manual

Samsung DB22D-T user manual

Samsung

Samsung DB22D-T user manual

Draper Smart Gym 503339 operating instructions

Draper

Draper Smart Gym 503339 operating instructions

Eaton XP-503 user manual

Eaton

Eaton XP-503 user manual

InFocus INF7011 Hardware guide

InFocus

InFocus INF7011 Hardware guide

AMX Modero ViewPoint MVP-5100 datasheet

AMX

AMX Modero ViewPoint MVP-5100 datasheet

Avalue Technology BFC-07R1 Quick reference guide

Avalue Technology

Avalue Technology BFC-07R1 Quick reference guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.