Differential pressure gauge Eco, model A2G-05
Differenzdruckmanometer Eco, Typ A2G-05
Manomètre différentiel Eco, type A2G-05
Manómetro diferencial Eco, modelo A2G-05
Manometro differenziale Eco, modello A2G-05
Differential pressure gauge Eco model A2G-05

2
40387565.03 03/2021 EN/DE/FR/ES/IT
WIKA operating instructions, model A2G-05
EN
DE
FR
ES
IT
© 04/2012 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA®is a registered trademark in various countries.
WIKA®ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d‘emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!
Prima di iniziare ad utilizzare lo strumento, leggere il manuale d'uso!
Conservare per future consultazioni!
Operating instructions model A2G-05 Page 3 - 14
Betriebsanleitung Typ A2G-05 Seite 15 - 26
Mode d'emploi type A2G-05 Page 27 -38
Manual de instrucciones modelo A2G-05 Página 39 - 50
Manuale d‘uso modello A2G-05 Pagina 51 - 62

3WIKA operating instructions, model A2G-05
40387565.03 03/2021 EN/DE/FR/ES/IT
EN
Declarations of conformity can be found online at www.wika.com.
Contents
Contents
1. General information 4
2. Design and function 5
3. Safety 6
4. Transport, packaging and storage 8
5. Commissioning, operation 8
6. Maintenance and cleaning 11
7. Dismounting, return and disposal 12
8. Specifications 13
9. Accessories 14

4WIKA operating instructions, model A2G-05
40387565.03 03/2021 EN/DE/FR/ES/IT
EN
1. General information
■The differential pressure gauge described in the operating instructions has been
designed and manufactured using state-of-the-art technology. All components
are subject to stringent quality and environmental criteria during production. Our
management systems are certified to ISO 9001 and ISO 14001.
■These operating instructions contain important information on handling the
instrument. Working safely requires that all safety instructions and work instructions
are observed.
■Observe the relevant local accident prevention regulations and general safety
regulations for the instrument's range of use.
■The operating instructions are part of the product and must be kept in the immediate
vicinity of the instrument and readily accessible to skilled personnel at any time. Pass
the operating instructions on to the next operator or owner of the instrument.
■Skilled personnel must have carefully read and understood the operating instructions
prior to beginning any work.
■The general terms and conditions contained in the sales documentation shall apply.
■Subject to technical modifications.
■Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: PM 07.42
- Application consultant: Tel.: +49 9372 132-0
Fax: +49 9372 132-406
info@wika.de
1. General information

5WIKA operating instructions, model A2G-05
40387565.03 03/2021 EN/DE/FR/ES/IT
EN
2. Design and function
2.1 Overview
Pressure measuring system
Scale pointer
2.2 Description
The model A2G-05 Eco differential pressure gauge is used for monitoring the differential
pressure in ventilation and air-conditioning applications.The measuring ranges cover
from 0 … 100 Pa to 0 … 6,000 Pa. Plus/minus ranges can be fulfilled from -50 … +50 Pa
to -1,500 … +1,500 Pa.The instruments measure the pressure by means of separating
diaphragms from silicone or, with the silicone-free version, from EPDM.The measuring
characteristics are in accordance with the EN 837-3 standard and ventilation and
air-conditioning (V/AC) regulations.
2.3 Scope of delivery
■Differential pressure gauge
■Mounting ring
■3 mounting screws
Cross-check scope of delivery with delivery note.
Differential pressure gauge Eco, without built-in module
2. Design and function

6WIKA operating instructions, model A2G-05
40387565.03 03/2021 EN/DE/FR/ES/IT
EN
3. Safety
3.1 Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious
injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries
or damage to property or the environment, if not avoided.
Information
... points out useful tips, recommendations and information for efficient
and trouble-free operation.
3.2 Intended use
This pressure gauge is designed for measuring very low pressures in dry, clean,
non-aggressive gases, primarily air.
The instrument has been designed and built solely for the intended use described here,
and may only be used accordingly.
The manufacturer shall not be liable for claims of any type based on operation contrary
to the intended use.
3.3 Improper use
WARNING!
Injuries through improper use
Improper use of the instrument can lead to hazardous situations and
injuries.
▶Refrain from unauthorised modifications to the instrument.
Any use beyond or different to the intended use is considered as improper use.
3. Safety

7WIKA operating instructions, model A2G-05
40387565.03 03/2021 EN/DE/FR/ES/IT
EN
3.4 Personnel qualification
WARNING!
Risk of injury should qualification be insufficient
Improper handling can result in considerable injury and damage to
property.
▶The activities described in these operating instructions may only be
carried out by skilled personnel who have the qualifications described
below.
Skilled personnel
Skilled personnel, authorised by the operator, are understood to be personnel
who, based on their technical training, knowledge of measurement and control
technology and on their experience and knowledge of country-specific regulations,
current standards and directives, are capable of carrying out the work described and
independently recognising potential hazards.
3.5 Labelling, safety marks
Product label (example)
Model Supply voltage
Measuring range Serial number
Output signal
Before mounting and commissioning the instrument, ensure you read the
operating instructions!
Type: A2G-50
Range: -250 ... +250 Pa
Output: 0 ... 10 V / 4 ... 20 mA
Supply: DC 24 V / AC 24 V ±10 % < 1 W
Made in EU E-Nr. 66209848
3. Safety

8WIKA operating instructions, model A2G-05
40387565.03 03/2021 EN/DE/FR/ES/IT
EN
4. Transport, packaging and storage
4.1 Transport
Check the differential pressure gauge for any damage that may have been caused by
transport.
Obvious damage must be reported immediately.
CAUTION!
Damage through improper transport
With improper transport, a high level of damage to property can occur.
▶When unloading packed goods upon delivery as well as during
internal transport, proceed carefully and observe the symbols on the
packaging.
▶With internal transport, observe the instructions in chapter
4.2 “Packaging and storage”.
4.2 Packaging and storage
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during transport (e.g. change
in installation site, sending for repair).
Permissible conditions at the place of storage:
■Storage temperature: -30 ... +80 °C
■Humidity: 35 ... 85 % relative humidity (no condensation)
5. Commissioning, operation
5.1 Installation and mechanical connection
In accordance with the general technical regulations for pressure measuring instruments
(e.g. EN 837-2 “Selection and installation recommendations for pressure gauges”).
air2guide standard gauges are calibrated in vertical position and should be installed
in the same position to avoid loss of class accuracy. If a different installation position
is required for air2guide instruments, please specify when ordering. Instruments with
high measuring ranges can be installed in a different, non-vertical mounting position by
simply adjusting the zero point.
4. Transport, packaging ... / 5. Commissioning, operation

9WIKA operating instructions, model A2G-05
40387565.03 03/2021 EN/DE/FR/ES/IT
EN
5. Commissioning, operation
Panel mounting with mounting ring, back mount
Panel mounting with threaded bezel, back mount
3 x Ø 3.73 x Ø 3.7
Ø 111
Ø 118
Ø 111
2 … 10/
29 … 50

10 WIKA operating instructions, model A2G-05
40387565.03 03/2021 EN/DE/FR/ES/IT
EN
5. Commissioning, operation
Detailed mounting steps with mounting ring
Detailed mounting steps with threaded bezel
After fitting the measuring element into the case it can be moved in a clockwise and
counterclockwise direction respectively for 15 angular degrees in order to ensure precise
horizontal positioning of the instrument.
5.2 Commissioning
■During the commissioning process pressure surges must be avoided at all costs.
■Protect pressure gauges from contamination, high temperature changes and
vibrations.
■Use the pressure gauge only if the diaphragm is undamaged and if it is in perfect
condition with regard to safety.
■Mounting of the pressure connection according to affixed symbols:
⊕ high pressure
⊖ low pressure

11WIKA operating instructions, model A2G-05
40387565.03 03/2021 EN/DE/FR/ES/IT
EN
5. Commissioning … / 6. Maintenance and cleaning
5.3 Zero point setting
In general, the zero point should only be checked and adjusted after the system has
been depressurised.
Mechanical and electrical zero point
If there is a deviation from the zero point (in depressurised condition), a zero point
correction can be carried out via the zero point setting (screw).The mechanical as well
as the electrical zero point can be adjusted simultaneously by turning the zero point
screw (at the front side of the instrument).
6. Maintenance and cleaning
For contact details see chapter 1 “General information” or the back page
of the operating instructions.
6.1 Maintenance
This instrument is maintenance-free.
Repairs must only be carried out by the manufacturer.
6.2 Cleaning
CAUTION!
Physical injuries and damage to property and the environment
Improper cleaning may lead to physical injuries and damage to property
and the environment. Residual media in the dismounted instrument can
result in a risk to persons, the environment and equipment.
▶Carry out the cleaning process as described below.
1. Before cleaning, correctly disconnect the instrument from the pressure supply,
switch it off and disconnect it from the mains.
2. Use the requisite protective equipment.
3. Clean the instrument with a moist cloth.
Electrical connections must not come into contact with moisture!
CAUTION!
Damage to the instrument
Improper cleaning may lead to damage to the instrument!
▶Do not use any aggressive cleaning agents.
▶Do not use any hard or pointed objects for cleaning.
4. Wash or clean the dismounted instrument, in order to protect persons and the
environment from exposure to residual media.

12 WIKA operating instructions, model A2G-05
40387565.03 03/2021 EN/DE/FR/ES/IT
EN
7. Dismounting, return and disposal
7.1 Dismounting
WARNING!
Physical injuries and damage to property and the environment
through residual media
Upon contact with hazardous media (e.g. oxygen, acetylene, flammable
or toxic substances), harmful media (e.g. corrosive, toxic, carcinogenic,
radioactive), and also with refrigeration plants and compressors, there is a
danger of physical injuries and damage to property and the environment.
▶Before storage of the dismounted instrument (following use) wash or
clean it, in order to protect persons and the environment from exposure
to residual media.
▶Observe the information in the material safety data sheet for the
corresponding medium.
7.2 Return
Strictly observe the following when shipping the instrument:
All instruments delivered to WIKA must be free from any kind of hazardous substances
(acids, bases, solutions, etc.) and must therefore be cleaned before being returned.
WARNING!
Physical injuries and damage to property and the environment
through residual media
Residual media in the dismounted instrument can result in a risk to
persons, the environment and equipment.
▶Clean the instrument, see chapter 6.2 “Cleaning”.
7.3 Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an environmentally
compatible way and in accordance with the country-specific waste disposal regulations.
Do not dispose of with household waste. Ensure a proper disposal in
accordance with national regulations.
7. Dismounting, return and disposal

13WIKA operating instructions, model A2G-05
40387565.03 03/2021 EN/DE/FR/ES/IT
EN
8. Specifications
Differential pressure gauge Eco, model A2G-05
Version ■Standard version
■Silicone-free version
Nominal size in mm 110
Measuring range ■0 … 100 Pa to 0 … 6,000 Pa
■-50 … +50 Pa to -1,500 … +1,500 Pa
Other plus/minus ranges on request
Unit ■Pa
■kPa
■inWC
■mmWC
■mbar
Scale ■Single scale
■Dual scale
Accuracy class
Span ≥ 250 Pa 3.0
Span 101 … 249 Pa 5.0
Span ≤ 100 Pa 10.0
Process connection Fixed connection in angular form for hoses with
inner diameter 4 … 6 mm
Movement Contact-free transmission (SWISS MOVEMENT)
Materials
Case components Plastic, glass-fibre reinforced
Separating diaphragm ■Silicone
■EPDM (with silicone-free version)
Window Polycarbonate (UV stabilised)
Dial Aluminium
Pointer Plastic, black
Mark pointer ■Without
■Plastic, red
Medium ■Air
■Non-flammable and non-aggressive gases
Permissible temperatures
Medium -20 … +50 °C [-4 … +122 °F]
Ambient -30 … +80 °C [-22 … +176 °F]
Max. working pressure (static pressure) 20 kPa
Ingress protection per IEC/EN 60529 ■IP54
■IP65
Weight (pressure measuring system) 240 g
8. Specifications

14 WIKA operating instructions, model A2G-05
40387565.03 03/2021 EN/DE/FR/ES/IT
EN
9. Accessories
9. Accessories
Description Order number
Static duct probes with combi hose connection for
pressure measuring hoses Ø 4 … 7 mm
Insertion length 100 mm 40232981
Insertion length 150 mm 40232999
Insertion length 200 mm 40233006
Measuring hoses
PVC hose, inner diameter 4 mm, roll at 25 m 40217841
PVC hose, inner diameter 6 mm, roll at 25 m 40217850
Silicone hose, inner diameter 4 mm, roll at 25 m 40208940
Silicone hose, inner diameter 6 mm, roll at 25 m 40208958
Duct connectors for measuring hoses Ø 4 … 6 mm 40217507
Weather protection 40241564

15WIKA Betriebsanleitung, Typ A2G-05
DE
40387565.03 03/2021 EN/DE/FR/ES/IT
Konformitätserklärungen finden Sie online unter www.wika.de.
Inhalt
Inhalt
1. Allgemeines 16
2. Aufbau und Funktion 17
3. Sicherheit 18
4. Transport, Verpackung und Lagerung 20
5. Inbetriebnahme, Betrieb 20
6. Wartung und Reinigung 23
7. Demontage, Rücksendung und Entsorgung 24
8. Technische Daten 25
9. Zubehör 26

16 WIKA Betriebsanleitung, Typ A2G-05
DE
40387565.03 03/2021 EN/DE/FR/ES/IT
1. Allgemeines
■Das in der Betriebsanleitung beschriebene Differenzdruckmanometer wird nach
dem aktuellen Stand der Technik konstruiert und gefertigt. Alle Komponenten
unterliegen während der Fertigung strengen Qualitäts- und Umweltkriterien. Unsere
Managementsysteme sind nach ISO 9001 und ISO 14001 zertifiziert.
■Diese Betriebsanleitung gibt wichtige Hinweise zum Umgang mit dem Gerät.
Voraussetzung für sicheres Arbeiten ist die Einhaltung aller angegebenen
Sicherheitshinweise und Handlungsanweisungen.
■Die für den Einsatzbereich des Gerätes geltenden örtlichen
Unfallverhütungsvorschriften und allgemeinen Sicherheitsbestimmungen einhalten.
■Die Betriebsanleitung ist Produktbestandteil und muss in unmittelbarer Nähe
des Gerätes für das Fachpersonal jederzeit zugänglich aufbewahrt werden.
Betriebsanleitung an nachfolgende Benutzer oder Besitzer des Gerätes weitergeben.
■Das Fachpersonal muss die Betriebsanleitung vor Beginn aller Arbeiten sorgfältig
durchgelesen und verstanden haben.
■Es gelten die allgemeinen Geschäftsbedingungen in den Verkaufsunterlagen.
■Technische Änderungen vorbehalten.
■Weitere Informationen:
- Internet-Adresse: www.wika.de / www.wika.com
- Zugehöriges Datenblatt: PM 07.42
- Anwendungsberater: Tel.: +49 9372 132-0
Fax: +49 9372 132-406
info@wika.de
1. Allgemeines

17WIKA Betriebsanleitung, Typ A2G-05
DE
40387565.03 03/2021 EN/DE/FR/ES/IT
2. Aufbau und Funktion
2.1 Überblick
Druckmesssystem
Skalenzeiger
2.2 Beschreibung
Das Differenzdruckmanometer Eco Typ A2G-05 wird zur Überwachung des
Differenzdruckes in der Luft- und Klimatechnik verwendet. Die Messbereiche reichen
von 0 … 100 Pa bis zu 0 … 6.000 Pa. Plus-/Minusbereiche können von -50 … +50
Pa bis -1.500 … +1.500 Pa erfüllt werden. Die Geräte erfassen den zu messenden
Druck mit Trennmembranen aus Silikon bzw. EPDM bei silikonfreier Ausführung.
Die messtechnischen Eigenschaften entsprechen der Norm EN 837-3 und den
Raumlufttechnik(RLT-)-Richtlinien.
2.3 Lieferumfang
■Differenzdruckmanometer
■Einbauring
■3 Befestigungsschrauben
Lieferumfang mit dem Lieferschein abgleichen.
Differenzdruckmanometer Eco, ohne Einbaumodul
2. Aufbau und Funktion

18 WIKA Betriebsanleitung, Typ A2G-05
DE
40387565.03 03/2021 EN/DE/FR/ES/IT
3. Sicherheit
3.1 Symbolerklärung
WARNUNG!
... weist auf eine möglicherweise gefährliche Situation hin, die zum Tod
oder zu schweren Verletzungen führen kann, wenn sie nicht gemieden
wird.
VORSICHT!
... weist auf eine möglicherweise gefährliche Situation hin, die zu
geringfügigen oder leichten Verletzungen bzw. Sach- und Umweltschäden
führen kann, wenn sie nicht gemieden wird.
Information
... hebt nützliche Tipps und Empfehlungen sowie Informationen für einen
effizienten und störungsfreien Betrieb hervor.
3.2 Bestimmungsgemäße Verwendung
Dieses Manometer dient zum Messen von sehr niedrigen Drücken bei trockenen,
sauberen, nicht aggressiven Gasen, hauptsächlich Luft.
Das Gerät ist ausschließlich für den hier beschriebenen bestimmungsgemäßen
Verwendungszweck konzipiert und konstruiert und darf nur dementsprechend
verwendet werden.
Ansprüche jeglicher Art aufgrund von nicht bestimmungsgemäßer Verwendung sind
ausgeschlossen.
3.3 Fehlgebrauch
WARNUNG!
Verletzungen durch Fehlgebrauch
Fehlgebrauch des Gerätes kann zu gefährlichen Situationen und
Verletzungen führen.
▶Eigenmächtige Umbauten am Gerät unterlassen.
Jede über die bestimmungsgemäße Verwendung hinausgehende oder andersartige
Benutzung gilt als Fehlgebrauch.
3. Sicherheit

19WIKA Betriebsanleitung, Typ A2G-05
DE
40387565.03 03/2021 EN/DE/FR/ES/IT
3.4 Personalqualifikation
WARNUNG!
Verletzungsgefahr bei unzureichender Qualifikation
Unsachgemäßer Umgang kann zu erheblichen Personen- und
Sachschäden führen.
▶Die in dieser Betriebsanleitung beschriebenen Tätigkeiten nur durch
Fachpersonal nachfolgend beschriebener Qualifikation durchführen
lassen.
Fachpersonal
Das vom Betreiber autorisierte Fachpersonal ist aufgrund seiner fachlichen Ausbildung,
seiner Kenntnisse der Mess- und Regelungstechnik und seiner Erfahrungen sowie
Kenntnis der landesspezifischen Vorschriften, geltenden Normen und Richtlinien in der
Lage, die beschriebenen Arbeiten auszuführen und mögliche Gefahren selbstständig zu
erkennen.
3.5 Beschilderung, Sicherheitskennzeichnungen
Typenschild (Beispiel)
Typ Hilfsenergie
Messbereich Seriennummer
Ausgangssignal
Vor Montage und Inbetriebnahme des Gerätes unbedingt die
Betriebsanleitung lesen!
Type: A2G-50
Range: -250 ... +250 Pa
Output: 0 ... 10 V / 4 ... 20 mA
Supply: DC 24 V / AC 24 V ±10 % < 1 W
Made in EU E-Nr. 66209848
3. Sicherheit

20 WIKA Betriebsanleitung, Typ A2G-05
DE
40387565.03 03/2021 EN/DE/FR/ES/IT
4. Transport, Verpackung und Lagerung
4.1 Transport
Differenzdruckmanometer auf eventuell vorhandene Transportschäden untersuchen.
Offensichtliche Schäden unverzüglich mitteilen.
VORSICHT!
Beschädigungen durch unsachgemäßen Transport
Bei unsachgemäßem Transport können Sachschäden in erheblicher Höhe
entstehen.
▶Beim Abladen der Packstücke bei Anlieferung sowie innerbetrieblichem
Transport vorsichtig vorgehen und die Symbole auf der Verpackung
beachten.
▶Bei innerbetrieblichem Transport die Hinweise unter Kapitel 4.2
„Verpackung und Lagerung“ beachten.
4.2 Verpackung und Lagerung
Verpackung erst unmittelbar vor der Montage entfernen.
Die Verpackung aufbewahren, denn diese bietet bei einem Transport einen optimalen
Schutz (z. B. wechselnder Einbauort, Reparatursendung).
Zulässige Bedingungen am Lagerort:
■Lagertemperatur: -30 ... +80 °C
■Feuchtigkeit: 35 ... 85 % relative Feuchte (keine Betauung)
5. Inbetriebnahme, Betrieb
5.1 Installation und mechanischer Anschluss
Entsprechend den allgemeinen technischen Regeln für Druckmessgeräte
(z. B. EN 837-2 „Auswahl- und Einbauempfehlungen für Druckmessgeräte“).
Die air2guide-Standardgeräte sind in vertikaler Lage der Membrane justiert und
sollten deshalb auch so montiert werden, um die Klassengenauigkeit einzuhalten.
Wenn air2guide-Geräte in einer anderen Position montiert werden müssen, sollte
dies im Bestellungsprozess spezifiziert werden. Höhere Messbereiche können durch
Verstellung der Nullpunktkorrektur in anderer Position als vertikal eingesetzt werden.
4. Transport, Verpackung ... / 5. Inbetriebnahme, Betrieb
Table of contents
Languages:
Other WIKA Measuring Instrument manuals

WIKA
WIKA 3 Series User manual

WIKA
WIKA 7000 Series User manual

WIKA
WIKA 732.14 User manual

WIKA
WIKA SENSeOR AMS01 User manual

WIKA
WIKA CTD4000 User manual

WIKA
WIKA CTD9100-1100 User manual

WIKA
WIKA 432.55 User manual

WIKA
WIKA 712.15.100 User manual

WIKA
WIKA mensor CPG2400 User manual

WIKA
WIKA TR Series User manual
Popular Measuring Instrument manuals by other brands

Data Harvest
Data Harvest SmartQ 3266 quick start guide

Diehl Metering
Diehl Metering Hydrus DN 15 Series installation guide

Quantronix
Quantronix CubiScan 125 Operation and technical manual

Zenner
Zenner WSD installation manual

Medical Econet
Medical Econet Cardio M Plus Opration manual

Phenix Technologies
Phenix Technologies MRM-10 user manual