Wittenstein Alpha LUC+125 User manual

LUC+125, battery, time-controlled
1000088470 Revision: 01
Sales department
WITTENSTEIN alpha GmbH
Walter
-Wittenstein-Straße 1
D
-97999 Igersheim
Germany
Customer Service department
In the event of technical
questions, contact the following address:
Copyright
© WITTENSTEIN alpha GmbH 2022
reserves all rights for layout and corporate design.
© DLS Schmiersysteme GmbH 2022
reserves all rights for content and text.
This documentation is protected by copyright.
WITTENSTEIN alpha GmbH
and DLS Schmiersysteme GmbH reserve all rights to photo-
mech
anical reproduction, copying, and the distribution by special processes (such as computers,
file media, data networks), in whole or in part.
Subject to technical and content changes without notice.

LUC+125, battery, time-controlled
Revision: 01 1000088470 en-1
Table of contents
1About this manual .............................................................................................................................3
1.1 Information symbols and cross references...................................................................................3
1.2 Scope of delivery..........................................................................................................................3
2Safety..................................................................................................................................................3
2.1 EC/EU Directive............................................................................................................................3
2.2 Personnel .....................................................................................................................................3
2.3 Intended use.................................................................................................................................4
2.4 Reasonably foreseeable misuse ..................................................................................................4
2.5 Guarantee and liability..................................................................................................................4
2.6 General safety instructions...........................................................................................................5
2.7 Structure of warning instructions..................................................................................................5
2.7.1 Safety symbols......................................................................................................................5
2.7.2 Signal words..........................................................................................................................6
3Description of the lubricator.............................................................................................................7
3.1 Overview of lubricator components ..............................................................................................7
3.2 Name plate and labeling...............................................................................................................7
3.3 Marking.........................................................................................................................................8
3.4 Ordering codes.............................................................................................................................8
3.5 Dimensions...................................................................................................................................8
3.6 Scope of delivery..........................................................................................................................8
3.7 Technical data..............................................................................................................................9
3.8 Lubricants...................................................................................................................................10
3.9 Cord lengths...............................................................................................................................10
4Transport and storage.....................................................................................................................10
4.1 Transport....................................................................................................................................10
4.2 Storage.......................................................................................................................................10
5Assembly..........................................................................................................................................11
5.1 Preparations...............................................................................................................................11
5.2 Mounting the lubricator...............................................................................................................11
5.3 Connecting the prefilled hose.....................................................................................................12
5.4 Electrical interface connection....................................................................................................12
6Startup and operation .....................................................................................................................13
6.1 Operation and settings ...............................................................................................................13
6.1.1 General................................................................................................................................13
6.1.2 Factory settings...................................................................................................................13
6.1.3 Actions with magnetic pen...................................................................................................14
6.2 Menu and display messages......................................................................................................14
6.3 Selection of parameters t and c..................................................................................................16
6.3.1 Menu structure ....................................................................................................................17
6.4 Error messages..........................................................................................................................18

LUC+125, battery, time-controlled
en-2 1000088470 Revision: 01
6.5 Switching the lubricator on/off....................................................................................................20
6.6 Parameter change in standard menu (Pro)................................................................................ 20
6.7 Triggering single lubrication cycle..............................................................................................21
6.8 Triggering the filling function (venting/filling).............................................................................. 21
6.9 Changing parameters in the "Advanced programming" menu................................................... 22
7Output signals – Time control ....................................................................................................... 23
7.1 Connection assignment – Time control...................................................................................... 23
7.2 Output signals / Display messages – Time control.................................................................... 23
7.3 Standard output signals at PIN 4 – Time control ....................................................................... 24
7.3.1 Empty cartridge signal........................................................................................................ 24
7.3.2 High-signal output (+24 V) at PIN 4.................................................................................... 24
7.3.3 Low-signal output (0 V) at PIN 4......................................................................................... 24
8Maintenance and disposal ............................................................................................................. 25
8.1 Maintenance schedule............................................................................................................... 25
8.1.1 Visual inspection.................................................................................................................25
8.1.2 Cleaning .............................................................................................................................25
8.1.3 Changing the cartridge and battery .................................................................................... 26
8.2 Recommissioning ......................................................................................................................28
8.3 Disposal..................................................................................................................................... 28
9Appendix.......................................................................................................................................... 29
9.1 EC/EU declaration of conformity................................................................................................29

LUC+125, battery, time-controlled
Revision: 01 1000088470 en-3
1 About this manual
This manual contains information which is necessary for the safe use of the LUC+125
(FlexxPump 125), battery version (time-controlled), hereinafter referred to as lubricator.
If this manual is supplied with amendment sheets (e.g. for special applications), then the
information in the amendment is valid. Contradictory specifications in this manual are therefore
void.
The user should contact WITTENSTEIN alpha GmbH with any questions about special
applications. The actual operator must guarantee and ensure that this manual including any
amendments are read and understood by all persons assigned to install, operate, or maintain the
lubricator. For this reason, keep this manual in a suitable and ideally accessible location near the
lubricator.
Inform colleagues who work in the area around the machine about the safety instructions so that
no one sustains injuries.
The original was written in German, all other language versions are translations of the original
manual.
1.1 Information symbols and cross references
The following information symbols are used:
•Indicates an action to be performed
ÜIndicates the results of an action
iProvides additional handling information
A cross reference refers to the chapter number and the header of the target section (e.g.
2.3 "Intended use").
A cross reference to a table refers to the table number (e.g. Table "Tbl - 1").
1.2 Scope of delivery
•Check the completeness of the delivery against the delivery note.
iImmediately notify the carrier, the insurance company, or WITTENSTEIN alpha GmbH in
writing of any missing parts or damage.
i
2 Safety
This manual, especially the safety instructions and the rules and regulations valid for the
operating site, must be observed by all persons working with the lubricator. General legal rules
and regulations as well as applicable rules and regulations on prevention of accidents [e.g.
personal protective equipment (PPE)] and environmental protection must be observed.
2.1 EC/EU Directive
In scope of the EC/EU Directive, commissioning (recommissioning) of a machine at which the
lubricator was installed and/or attached is prohibited until it is verified that the machine complies
with all provisions of the applicable regulation.
An EC/EU declaration of conformity for this lubricator can be found in the appendix (see
chapter 9.1 "EC/EU declaration of conformity").
2.2 Personnel
Only technicians who have read and understood this operating manual may perform work on the
lubricator. Local and/or company regulations apply accordingly.

LUC+125, battery, time-controlled
en-4 1000088470 Revision: 01
2.3 Intended use
For the intended use of the lubricator, the following points must be observed:
- The lubricator is approved only for industrial applications.
- The lubricator may only be put into operation according to the technical specifications (see
chapter 3.7 "Technical data").
- Unauthorized modifications to the lubricator are not permitted.
- Read and observe the operating manual.
- During operation of the lubricator, regular visual inspections must be carried out at the
lubricator itself as well as the lubrication point. Any irregularities and their cause must be
corrected immediately.
- The cartridge must not be refilled.
- The lubricator must not be opened or dismantled.
- Only lubricants which are approved by WITTENSTEIN alpha GmbH may be used.
- Applicable rules and regulations on occupational safety, prevention of accidents and
environmental protection must be observed.
- Any works or tasks with or at the lubricator may only be carried out with authorization (see
chapter 2.2 "Personnel").
Any use other than the previously described intended use or non-compliance with one of the
points specified above is regarded misuse. In this case no liability or warranty claims will be
assumed.
2.4 Reasonably foreseeable misuse
Any usage of the lubricator that exceeds the maximum permitted technical data is considered
misuse and is therefore prohibited.
2.5 Guarantee and liability
Any guarantee and liability claims are excluded for personal injury and/or material damage in
case of:
- Ignoring the information on transport and storage;
- Misuse;
- Improper or not carried out maintenance and repair;
- Incorrect assembly / disassembly or incorrect operation;
- Operation of the lubricator when safety devices and equipment are defective;
- Operation of the lubricator without lubricant;
- Operation of the lubricator with non-approved lubricant;
- Operation of a heavily contaminated lubricator;
- Modifications or changes without written approval by WITTENSTEIN alpha GmbH;
- Opening and/or partly or complete dismantling of the lubricator.

LUC+125, battery, time-controlled
Revision: 01 1000088470 en-5
2.6 General safety instructions
The operation of the lubricator involves remaining risks even when adhering to the intended use.
Defective or faulty electrical connections or unapproved, current-carrying components can
cause serious injuries and even death.
•Have all electrical connection work performed by qualified technicians only.
•Immediately replace damaged cords or plugs.
Loose or overtightened screw connections can cause damage to the lubricator:
•Mount and check all screw connections according to the specified admissible tightening
torques. Use a calibrated torque wrench.
Lubricants are flammable, can cause skin irritation, and can contaminate soil and water:
•In case of fire, do not use a jet of water to extinguish.
•In case of fire, only use suitable extinguishing agents such as powder, foam or carbon
dioxide.
•Always observe the applicable safety instructions by the lubricant manufacturer on the safety
data sheet of the used lubricant.
•Use protective gloves to avoid direct skin contact with lubricants.
•Use and dispose of lubricants properly.
2.7 Structure of warning instructions
Warning instructions are situation-specific. They will
be precisely where tasks are described in which
dangers can arise.
The warning instructions in this manual are
designed according to the following pattern:
A
= safety symbol
B
= signal word
C
= Type and consequence of the danger
D
= Avoiding the danger
2.7.1 Safety symbols
The following safety symbols are used to indicate hazards, prohibitions and important
information:
General danger
Electric voltage
Flammable
Environment
AB
CD

LUC+125, battery, time-controlled
en-6 1000088470 Revision: 01
2.7.2 Signal words
This signal word indicates an imminent danger that will cause
serious injuries or even death.
This signal word indicates a potential hazard that could cause
serious injuries and even death.
This signal word indicates a potential hazard that could cause minor
or serious injuries.
This signal word indicates a potential hazard that could lead to
property damage.
DANGER
WARNING
CAUTION
NOTICE

LUC+125, battery, time-controlled
Revision: 01 1000088470 en-7
3 Description of the lubricator
The lubricator is designed as a highly compact double piston pump for grease as lubricant. The
two pistons run force-controlled and in opposing directions. They are both connected to the same
outlet. The outlet is secured by an integrated check valve. At each dispensing cycle , approx.
0.15 cm³ of lubricant are dispensed. Multiple subsequent dispensing processes can be set.
The lubricator features an electrical interface. The included magnetic pen allows for the
lubrication amount dispensed per time to be adjusted or set to ensure ideal supply of lubricant to
the lubrication point.
The different operating states are displayed at the front as well as other additional information
(e.g. empty cartridge, errors).
The power supply is established via a replaceable battery. The lubricator can be switched on/off
via the M12x1 interface. An external power supply can also be used to transmit information about
an empty cartridge as well as error messages, e.g. to an external control system.
We recommend the battery-powered lubricator exclusively for stand-alone lubrication points
which do not have to be monitored externally or which may not be supplied with external power.
Owing to its increased operational reliability and the expanded settings options for emitting
signals, the 24V-DC version is the better choice in terms of technology and economic efficiency, if
information about an empty cartridge and error messages are to be transmitted to a control
system (e.g. PLC). You can obtain further information about an existing product from
WITTENSTEIN alpha GmbH directly.
3.1 Overview of lubricator components
Pos.
Designation
1
LUC+125, battery version, time-controlled
2
Exchange cartridge LUE+125
3
Assembly bracket
4
Interface M12x1, 4-pole
5
Magnetic pen (in holder)
6
Hose connection
7
Action field
8
Display
9
Name plate
10
CE symbol
-
Battery
Tbl - 1 Overview of lubricator components
3.2 Name plate and labeling
Pos.
Designation
A
Material number
B
Ordering codes (see chapter 3.4 "Ordering codes")
Tbl - 2 Name plate
1
8
7
2
3
4
5
6
9
10
Mat-No: xxxxxxxx
LUC+125-xxxx-xx
A
B

LUC+125, battery, time-controlled
en-8 1000088470 Revision: 01
3.3 Marking
The CE mark is attached to the lubricator housing. The position of the CE mark is described in
chapter 3.1 "Overview of lubricator components".
Manufacturer
DLS Schmiersysteme GmbH
Gewerbering 5
82140 Olching, Germany
Tel.: +49-(0)8142-65069-0
Fax: +49-(0)8142-65069-29
Email: mail@DLS-Schmiersysteme.de
www.DLS-Schmiersysteme.de
3.4 Ordering codes
3.5 Dimensions
Dimensions can be found
- in our catalog,
- under www.wittenstein-alpha.de.
CAD data and dimension sheets are available upon request.
3.6 Scope of delivery
The lubricator is available in different versions. They can be distinguished by the execution, the
lubricant filling as well as the included accessories.

LUC+125, battery, time-controlled
Revision: 01 1000088470 en-9
3.7 Technical data
Housing
Dimensions without cartridge
83 x 96 x 85 (W x H x D)
mm
Dimensions with cartridge 125 cm3
83 x 154 x 85 (W x H x D)
mm
Weight (without cartridge)
approx. 350
g
Assembly option
Assembly bracket with slotted
holes pre-assembled.
Bottom side: IG M5 (3 Nm)
Mounting position
vertically
Housing material
PA 6.6 GF30 / POM
Outlet material
Stainless steel
Operating temperature *
0 ... +60
°C
Lubricant and hydraulics
Cartridge volume
125
cm3
Lubricant properties
Grease up to NLGI, class 2
No. of outlets
1
Hydraulic connection
PA hose
Max. pressure
50 (-10%/+15%)
bar
Dispensed volume
Per stroke 0.15 (-5%)
cm3
Electrics
Display
Display
Operating voltage (DC)
4.5
V
Operating voltage (DC) of external status
monitoring
24 (20V...28V)
V
Fuse protection
0.75 (slow)
A
Protection class
IP 54
Power consumption
I
max
< 0.3 I
bias
< 0.025
A
For further information on the electrical system, see chapter 7 "Output signals – Time control"!
* Depending on the lubricant used
Tbl - 3 Technical data

LUC+125, battery, time-controlled
en-10 1000088470 Revision: 01
3.8 Lubricants
Only use lubricants approved by WITTENSTEIN alpha GmbH in dedicated original cartridges
exclusively developed for the lubricator.
The lubricants used depend on the individual application. The
respective designation can be found on the label of the cartridge.
For further information about lubricants, documentation and safety data sheets, please contact
WITTENSTEIN alpha GmbH directly.
3.9 Cord lengths
In general, the lubricator should be installed as closely as possible to the device to be supplied
(lubrication point). Ideally, this should be directly at the lubrication point. If this is not possible due
to space restrictions or reasons regarding accessibility, cords can be used between the lubricator
and the lubrication point (e.g. distribution).
The maximum hose length depends on the temperature as well as the used grease, hoses and
accessories.
4 Transport and storage
The lubricator is delivered in an outer packaging (cardboard box) and with a lubricant cartridge
and other accessories in the same shipment. For protection against humidity and dirt, it is
additionally packaged in PE foil. To prevent leakage of the prefilled lubricant from the lubricator,
protective caps are installed at the lubricant inlet and outlet.
Dispose of the packaging materials at the recycling sites designated for this purpose in
compliance with applicable national and operational regulations.
After receipt of the lubricator, check the completeness of the delivery against the delivery note.
Immediately notify the carrier, the insurance company, or WITTENSTEIN alpha GmbH in writing
of any potentially missing parts or damage.
4.1 Transport
Hard shocks, for instance because of falling or hard dropping, can
damage the lubricator.
•Do not throw the lubricator.
4.2 Storage
Store the lubricator in its original packaging in vertical position under dry, frost-protected
conditions at an ambient temperature of +5°C to +30°C. The maximum unopened storage time is
1 year.
For storage logistics, the "First-In-First-Out principle" (FiFo) is recommended.
NOTICE

LUC+125, battery, time-controlled
Revision: 01 1000088470 en-11
5 Assembly
The lubricator is delivered with an inserted lubricant cartridge in vented condition as a ready-to-
install component with an installed assembly bracket. The outlet is sealed with a yellow cap.
The provided hose lines have already been prefilled with the respective lubricant.
5.1 Preparations
Among other things, compressed air can lead to damage to the seals
of the lubricator and to contamination of the lubricator or lubricant by
dirt and particles.
•Do not use compressed air.
•Make sure that the assembly location is not considerably
contaminated.
5.2 Mounting the lubricator
•Observe the safety and processing instructions for the threadlocker
to be used.
•Apply threadlocker (e.g. LOCTITE®243) to the
fastening screws [K].
•
Install the lubricator with the pre-assembled
assembly brackets [3] at the intended position.
The slotted holes enable fine adjustment of the
installation height.
i
The prescribed screw sizes and tightening
torques can be found in the table "Tbl".
Hole spacing
[mm]
Quantity x diameter
[ ] x [mm]
For screw size /
property class
Tightening torque
[Nm]
95
2 x 6.6
M6 / 8.8
9.0
Tbl - 4 Through-holes in assembly bracket
K
3
NOTICE

LUC+125, battery, time-controlled
en-12 1000088470 Revision: 01
5.3 Connecting the prefilled hose
•Remove the yellow closing cap.
•
Screw in the provided hose connection [6].
iMax. tightening torque 2 Nm.
•
Establish the hydraulic connection between the
distributor and the lubricator [6]. Ensure that
hoses and connection elements are tight and
properly assembled.
i
If possible, use the prefilled hoses included in
the scope of delivery with the respective
lubricant!
iFurther important instructions on how to connect the hose can be found in the separate
manual "Prefilled high pressure hose" (doc. no. 2098-D072334). The manual is included in
the scope of delivery of the hose or is available on request from WITTENSTEIN alpha
GmbH. Always state the material number when doing so.
5.4 Electrical interface connection
Defective or faulty electrical connections or unapproved, current-
carrying components can cause serious injuries and even death.
•Have all electrical connection work performed by qualified technicians
only.
•Immediately replace damaged cords or plugs.
•Observe the five safety rules of electrical engineering before starting
electrical installation work:
- Switch off the power supply.
- Secure against unintended reactivation.
- Check that there is no voltage.
- Ground and short-circuit.
- Cover adjacent and electrified parts.
The following work steps must only be carried out if you
- wish to switch the lubricator on and off externally.
- wish to retrieve error messages.
•Connect the lubricator [1] to the external power
supply or control system with a suitable
connection cord [J] via the M12x1 interface [4]
at the bottom of the lubricator.
i
Further information can be found in chapter 6.5
"Switching the lubricator on/off".
i
Depending on the application, connection cords
with straight or angled socket can be used.
i
For the properties of the connection cord,
please refer to chapter 7.1 "Connection
assignment – Time control".
6
J
1
4
DANGER

LUC+125, battery, time-controlled
Revision: 01 1000088470 en-13
6 Startup and operation
•Read the general safety instructions before beginning to work (see chapter 2.6 "General
safety instructions").
•Make sure that the lubricator is properly and fully assembled. In particular, the power supply
must be connected, and a lubricant cartridge must be attached.
6.1 Operation and settings
6.1.1 General
What you should know about operation and setting of the lubricator:
- The lubricator is designed as an individual lubricator for one lubrication point.
- The lubricator is time-controlled and works time-based via the integrated microelectronics.
Power is supplied from a battery. The lubricator cyclically delivers a defined amount of
lubricant from the cartridge to the outlet.
- The re-lubrication amount is defined in months by the emptying time setting of the cartridge.
Discharge times tof 1...24 month(s) and a number of cycles cof 1…10 can be set.
- The single-use changeable cartridges with a lubricant capacity of 125 cm3ensure controlled
and consistent quality of lubricants and are filled without any trapped air. The lubricator offers
a reliable supply to lubrication points and prevents downtime of machinery. This version of the
lubricator is designed for grease lubricants.
- The lubricator can be used without an external 24 V DC power supply. The lubricant cartridge
is included in the scope of delivery and already installed in the lubricator.
- To call up the empty cartridge message or error messages, an external 24V-DC power supply
is required.
- The respective conditions of the lubricator are shown on the display, which also enables
recognition of the status by LEDs in different colors.
- In case of any questions regarding your applications and the correct settings for the lubricator,
please contact WITTENSTEIN alpha GmbH.
6.1.2 Factory settings
Parameter
Program menu
Designation
Factory settings
Result
t
Emptying time
6
6 months
c
Number of cycles
2
2 pump strokes per
lubrication
(0.15 cm3/ stroke)
P
Maximum pressure
35
35 bar
The parameter Pmay only be changed after consultation.
If you have any questions, please contact
WITTENSTEIN alpha GmbH Sales / Customer Service.
Tbl - 5 Factory settings

LUC+125, battery, time-controlled
en-14 1000088470 Revision: 01
6.1.3 Actions with magnetic pen
The magnetic pen attached to the bottom of the lubricator allows to perform actions and changes
of settings on the lubricator. This magnetic pen can be easily and safely stored permanently
under the lubricator.
•Remove the magnetic pen [5] from the bottom
of the lubricator.
i
The magnetic pen is permanently held
magnetically in the receptacle on the bottom.
Simply pull it out.
•Guide the magnetic pen [5] onto the action field
SET [7] at the front of the lubricator.
Ü
As soon as the magnetic pen is recognized by
the lubricator when placed on the action field
SET, the red LED lights up in the display. The
menu changes at 2 second intervalls.
•
Remove the magnetic pen from the action field
SET when the desired menu item is shown on
the display.
Ü
The red LED is turned off. You have performed
an action. The display flashes 2x briefly together
with the green LED.
•After having performed the desired action or settings, insert the magnetic pen back into the
receptacle provided on the bottom of the lubricator.
6.2 Menu and display messages
The display of the lubricator is used to show various kinds of information to the user.
Symbol
Designation
Notice
Display information
The display visually shows information
both during operation and for
programming.
Tbl - 6 Display information
Display
Assignment
Top LED: red
Bottom LED: green
Tbl - 7 LED assignment
5
5
7

LUC+125, battery, time-controlled
Revision: 01 1000088470 en-15
Information in
display
Meaning
See chapter
No display
Battery not connected; battery completely empty
6.1
OFF
Lubricator switched off
6.5
ON
Lubricator switched on and ready for use
6.5
PRO
PRO menu
6.6
c1 ... 10
Adjustable setting of the number of cycles c
01 ... 24
Adjustable setting of the discharge time c
RUN
RUN menu
6.7
01 … 35
During the manually triggered active run
command, the display shows the approximate
counterpressure in bar. In addition, the green
LED lights up.
FIL
FIL menu
6.8
01...35
During the manually triggered active FIL
command, the display shows the approximate
counterpressure in bar. In addition, the green
LED lights up.
Clr
If the process is canceled during the FIL
command, Clr is displayed.
INF
INF menu
6.9
A90
Firmware version of the lubricator
r01
Firmware version of the lubricator
t06
Currently set value of the discharge time t
c02
Currently set value of the number of cycles c
P35
Currently set maximum pressure P
E1
Error E1 (empty cartridge)
6.4
E2
Error E2 (cartridge error / no cartridge fitted)
6.4
E3
Error E3 (undervoltage)
6.4
E4/E5
Error E4/E5 (fatal error)
6.4
E7
Error E7 (overload)
6.4
01 … 35
After each cycle, the maximum applied counterpressure
during the cycle is displayed in bar.
Tbl - 8 Display messages

LUC+125, battery, time-controlled
en-16 1000088470 Revision: 01
6.3 Selection of parameters t and c
Discharge time t
Month
1
3
6
10
12
15
20
24
Lubrication volume per
month 125 (U12) [cm3]
125
41.6
20.8
12.5
10.4
8.3
6.3
5.2
Tbl - 9 Discharge time tfor cartridge
Values for tare exemplary, values from 1 - 24 (24 V version) can be set.
Number of cycles c
1
2
3
4
5
6
7
8
9
10
Lubrication volume per
cycle [cm3]
0.15
0.3
0.45
0.6
0.75
0.9
1.05
1.20
1.35
1.5
Tbl - 10 Number of cycles c, strokes per cycle
The discharge time tsets the period over which the total volume of lubricant per cartridge is
delivered. Accordingly, this also determines how much lubricant is supplied per month.
The number of cycles cindicates how many strokes are performed per lubrication process and
how much lubricant is supplied per lubrication process.
The time between two lubrication process (pause time) can be determined with the following
formula:
TPause = t x 720 h x c / H
Using tin hours and Has the number of total strokes per cartridge (830, for cartridge 125 cm³)
and a lubrication volume of 0.60 cm³ (c4) over 6 months, the following pause time is obtained as
an example:
TPause = 6 x 720 h x 4 / 830 = 20.9 h
For above parameters tand c, the lubrication cycle is 21 hours. A lubrication volume of 0.60 cm³
is dispensed every 21 hours over a period of six months.

LUC+125, battery, time-controlled
Revision: 01 1000088470 en-17
6.3.1 Menu structure
The following figure illustrates the complete menu structure of the lubricator.
Symbol
Designation
Symbol
Designation
Action by user, LED flashes
red once
Lubricator is ready for operation
but not switched on
Action by user, LED flashes
red several times Lubricator is in operation
Sequence/reaction in menu
Perform individual manual
dosing operation
LED in display flashes green
Programming
LED in display flashes red
Extended programming (only
after consultation)
Indicator in display flashes 2x
Advanced programming
Firmware information
Lubricator is switched on via an
external switch
Programming
(Standard menu)
Lubricator is switched off via an
external switch
Tbl - 11 Menu structure
MAX1
10x
MAX1 MAX2 MAX1 MAX2 MAX1

LUC+125, battery, time-controlled
en-18 1000088470 Revision: 01
6.4 Error messages
The status is permanently monitored by the microelectronics integrated in the lubricator. In case
of any irregularities, an addressed error message is issued and shown on the display. The red
LED flashes every 5 seconds to visually indicate an error.
Display
Fault
Explanation
Remedy
E1
Cartridge empty
•Place a new cartridge on the
lubricator (see chapter 8.1.3
"Changing the cartridge and
battery").
iNo need to acknowledge the
error; it is automatically cleared
after the corrective action is
performed.
E2
Cartridge error;
cartridge not
recognized or
incorrectly fitted
E3
Battery very low
•Switch the lubricator off (OFF).
•Replace the battery along with
the cartridge (see chapter
8.1.3 "Changing the cartridge
and battery").
•Switch the lubricator on (ON).