MEMOLUB HPS User manual

Lubrication Systems MEMOLUB® HPS
MEMOLUB® hps is an autonomous single / multi
point lubrication system available in three sizes
(Standard : 120cc, Mega 240cc and Giga 480cc). Its
high lubricant ejection pressure of 25 bar opens a
wide range of applications not possible with
conventional systems. MEMOLUB® HPS can be used
remotely up to 8 meters from the lubrication point or
as a central lubrication system using progressive
distributor valves. Combined with the SPLITTER
MEMO, it makes it an economic way to lubricate 2
lube points.
Remote installation avoids dangerous or difficult access points, and maintenance personnel can work
swiftly in safety. Machine stoppage for lubrication can be avoided and production efficiency can be
increased.
Cartridges are carefully filled at the factory using a precise centrifuging process that eliminates air
pockets and contamination. Cartridge change-out normally takes less than 60 seconds!
MEMOLUB® is a valuable alternative to time-consuming and costly manual lubrication.
The MEMO is a unique system for adjusting daily lubricant
output. Programmed the first time, it is permanently fitted
onto the lube point. Maintenance personnel do not need to
remember which setting is necessary and organization is thus
simplified.
MEMOLUB HPS
Specifications & Operating Characteristics:
MEMOLUB HPS Characteristics:
Capacity : Standard 120cc Dimensions : Standard 115 x 101
Mega 240cc Mega 147 x 101
Giga 480cc Giga 228 x 101
Battery Pack : 4,5V Alkaline Min Constant Temp. : Standard : -10°C
Settings : via MEMO Mega : -5°C
Temp. Exposition : -40°C to +50°C Giga : 0°C
Installation thread : ¼ Inch R lubricants : Oil and greases up to
Grade NLGI 2.5
Lubrication Systems MEMOLUB® HPS
Lubricator Installation Instructions
1. Setting of MEMO with combination of
three rings (black, White and red) as
described in the table
Lubricant Cartridge Change Out Instructions
1. To open, place
the lubricator
upright on flat
surface. Press firmly
and turn locking ring
counter-clockwise
while holding the
ribbed surface.
3. Carefully squeeze
air out of the
cartridge until grease
begins to emerge
from the outlet.
4. Place the cartridge on
the inlet of the lower
h
ousing.
Grease Cartridges Only.
3. Hold the cartridge
with the outlet facing
up. Carefully remove
the cartridge plug.
Turn the lower
housing over and
gently place it on the
outlet of the cartridge
4. While holding the
cartridge and lower
housing together, flip
the assembly over
and hold the cartridge
in place.
Oil Cartridges Only.
5. Place the clear
housing assembly
over the lubricant
cartridge and lower
housing.
6. Holding the
locking ring by its
ribbed surface, turn
it clockwise until it
clicks into the
locked position.
7. Screw the
MEMOLUB®
HPS lubricator onto
the Power-Through
MEMO.
Note: If necessary,
prime the
MEMOLUB® HPS
with a hand grease
gun (grease
application only).
SAFETY PRECAUTIONS
* Warning: Lower housing contains a
loaded spring. Do not open.
* Use only factory pre-filled cartridges
with MEMOLUB lubricator.
Ring
Freq. 120 cc 240 cc 480 cc
Black 48 h 12 months 2 years* -
White 24 h 6 months 12 months 2 years*
Black + White 16 h 4 months 8 months 16 months
Red 12 h 3 months 6 months 12 months
Black + red 6 h - 3 months 6 months
White + Red 2 h - 1 months 2 months
Black + White + Red 1 h - 15 days 1 months
2. Insert battery
pack inside battery
compartement.

Other manuals for HPS

3

Other MEMOLUB Lubrication System manuals

MEMOLUB HPS User manual

MEMOLUB

MEMOLUB HPS User manual

MEMOLUB PLCD User manual

MEMOLUB

MEMOLUB PLCD User manual

MEMOLUB ONE User manual

MEMOLUB

MEMOLUB ONE User manual

MEMOLUB HPS User manual

MEMOLUB

MEMOLUB HPS User manual

MEMOLUB HPS Operator's manual

MEMOLUB

MEMOLUB HPS Operator's manual

Popular Lubrication System manuals by other brands

UE Systems ULTRAPROBE 10000 Indentification and Operation

UE Systems

UE Systems ULTRAPROBE 10000 Indentification and Operation

OEM Tools 87042 Operating instructions and parts manual

OEM Tools

OEM Tools 87042 Operating instructions and parts manual

MASTER PNEUMATIC-DETROIT, INC. BL237D-6 Installation and Maintenance

MASTER PNEUMATIC-DETROIT, INC.

MASTER PNEUMATIC-DETROIT, INC. BL237D-6 Installation and Maintenance

SKF Vectolub VTEC Installation and commissioning

SKF

SKF Vectolub VTEC Installation and commissioning

simalube multipoint 5x8 user manual

simalube

simalube multipoint 5x8 user manual

SKF TLGU 10 Instructions for use

SKF

SKF TLGU 10 Instructions for use

Graco 24Z764 instructions

Graco

Graco 24Z764 instructions

Atlanta BKI 109 e operating instructions

Atlanta

Atlanta BKI 109 e operating instructions

Engine Clean Solutions OIL RX-3000 Reference manual

Engine Clean Solutions

Engine Clean Solutions OIL RX-3000 Reference manual

Perma Star Control Time operating instructions

Perma

Perma Star Control Time operating instructions

YAMADA SKR-110A50 Instruction

YAMADA

YAMADA SKR-110A50 Instruction

SKF VSG Series Assembly instruction

SKF

SKF VSG Series Assembly instruction

Dynacut MDM Operation manual

Dynacut

Dynacut MDM Operation manual

SKF KGF Series General information

SKF

SKF KGF Series General information

Bijur Delimon V5 quick start guide

Bijur Delimon

Bijur Delimon V5 quick start guide

SKF 501-301-310-S1 Assembly instructions

SKF

SKF 501-301-310-S1 Assembly instructions

Lincoln Quicklub Series Operation and Troubleshooting Guide

Lincoln

Lincoln Quicklub Series Operation and Troubleshooting Guide

Bijur Delimon CSK instructions

Bijur Delimon

Bijur Delimon CSK instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.