Wittkopp Primor 2000 User manual

User’s manual
Primor 2000 / Level 5
Content
1 General instructions __________________________________________________________ 2
1.1 Liability notes _________________________________________________________________ 2
1.2 Operating notes_______________________________________________________________ 2
1.3 Notes on safety________________________________________________________________ 2
2 Visual and acoustic signals____________________________________________________ 2
3 Input unit _____________________________________________________________________ 3
4 Operating the lock____________________________________________________________ 3
4.1 Opening _____________________________________________________________________ 3
4.2 Locking ______________________________________________________________________ 3
5 Programming the lock ________________________________________________________ 4
5.1 Master and user code __________________________________________________________ 4
5.1.1 Programming the user code (programme 1) _____________________________________ 4
5.1.2 Changing the master or user code (programme 0) _______________________________ 4
5.1.3 Deleting the user (programme 3)_______________________________________________ 4
5.2 Time delay and opening window_________________________________________________ 5
5.2.1 Adjusting the time delay and opening window (programme 9) _____________________ 5
5.2.2 Opening with activated time delay and opening window __________________________ 6
5.2.3 Deleting the time delay (programme 9) _________________________________________ 6
6 Testing the system (programme 5) ____________________________________________ 7
7 Power supply and battery change _____________________________________________ 7
© Carl Wittkopp GmbH - Errors and omissions excepted
User´s manual no. 9999-114-1

2
Primor 2000 / Level 5
04.05.2012
2 Visual and acoustic signals
Signal Explanation Comment
Right code
Wrong code or code denied
Short signal
Long signal
☼
LED flashes every 10 seconds Blocking time is active.
LED flashes every 2 seconds Time delay is active.
Battery warning Battery should be changed soon.
1 General instructions
• Please read the operating instructions carefully, before activating the lock.
1.1 Liability notes
• We don’t assume liability for malfunctions due to incorrect operation, use of force or inappropriate handling. In cases of
damage to property or valuables, which are due to incorrect locking of the safe, we also don’t assume liability.
• If your safe, however, does not open correctly with the following instructions, please contact the manufacturer of the safe.
1.2 Operating notes
• When programming, the electronic lock has to be opened.
• If the lock is not opened or closed within 3 seconds after entering the code, the electronics switch off. Re-enter the code and
repeat the process.
• When the time between touching keys exceeds 10 seconds the process of programming and entering is deleted. The old
code or programmes stay valid.
• Every correct input while entering the code is conrmed by an acoustic signal and ashing of the red LED. These signals will
not be considered in this instruction.
• The red LED ashes during the whole process of programming. These signals will not be considered in this instruction.
• Never use force.
• Do not open the lock case, otherwise you compromise the function of the lock and warranty will be void.
1.3 Notes on safety
• For your security, change the factory code 1 2 3 4 5 6 immediately.
• For your new code, do not use any personal data like birthdays or any other data, which could be known by knowledge of
your person.
• After entering the new code, the electronic lock should be opened and locked several times with the safe door opened.
• After each locking doublecheck if the safe is closed.

3
Primor 2000 / Level 5
04.05.2012
4 Operating the lock
4.1 Opening
1. Enter the 6-digit code e.g. master code. 123456
2. Turn the input unit clockwise within 3 seconds into opening position.
The lock is opened.
• After 4 consecutive wrong code inputs, a blocking time of 5 minutes occurs. During this blocking time the red LED ashes
every 10 seconds and every input is accompanied by a long signal tone. After the blocking time has passed 2 further incor-
rect inputs will restart the blocking time.
4.2 Locking
1. Close the door at the safe and turn the input unit counterclockwise into
locking position. The lock is closed.
3 Input unit
Primor RO

4
Primor 2000 / Level 5
04.05.2012
5.1.3 Deleting the user (programme 3)
The master is able to delete the user, but not vice versa.
1. Press and hold the key “3“ until the red LED flashes permanently. 3
2. Enter your 6-digit master code e.g. 123456
5.1.2 Changing the master or user code (programme 0)
1. Press and hold the key “0“ until the red LED flashes permanently. 0
2. Enter your old 6-digit code e.g. user code. 111111
3. Enter your new 6-digit code e.g. 567891
4. Re-enter your new 6-digit code e.g. 567891
5 Programming the lock
5.1 Master and user code
5.1.1 Programming the user code (programme 1)
The master is able to program the user code, but not vice versa.
1. Press and hold the key “1“ until the red LED flashes permanently. 1
2. Enter your 6-digit master code e.g. 123456
3. Enter the new 6-digit user code e.g. 111111
4. Re-enter the new 6-digit user code e.g. 111111
• A new user code will be allowed only if the code is differing in two places by a single digit from an existing code.
• Should the new code be denied, restart the process of programming.

5
Primor 2000 / Level 5
04.05.2012
5.2.1 Adjusting the time delay and opening window (programme 9)
1. Press and hold the key “9“ until the red LED flashes permanently. 9
2. Enter your 6-digit master code e.g. 123456
3. Enter the time delay e.g. 20 minutes. 20
4. Enter the opening window e.g. 10 minutes. 10
5. Re-enter the time delay e.g. 20 minutes. 20
6. Re-enter the opening window e.g. 10 minutes. 10
• The time delay can be increased at any time. It can be reduced only during the opening window.
5.2 Time delay and opening window
Only the master can program or delete the time delay.
Time delay: 01 - 99 minutes - time to wait until the lock can be opened.
Opening window: 01 - 19 minutes - within this time window the master or the user can open the lock with his code.
Code input – beginning of the time delay
Wait during the time delay
Opening window – re-enter code

6
Primor 2000 / Level 5
04.05.2012
5.2.3 Deleting the time delay (programme 9)
The time delay can only be deleted within the opening window.
The opening window runs after deleting the time delay for the last time.
1. Enter your 6-digit code e.g. mastercode. 123456
2. Wait until the end of the time delay. ☼
3. Opening window starts. ☼
4. Press and hold the key “9“ until the red LED flashes permanently. 9
5. Enter your 6-digit master code e.g. 123456
6. Delete the time delay. 00
7. Delete the opening window. 01
8. Delete the time delay again. 00
9. Delete the opening window again. 01
5.2.2 Opening with activated time delay and opening window
1. Enter your 6-digit code e.g. mastercode. 123456
2. Wait until the end of the time delay. ☼
3. Opening window starts. ☼
4. Re-enter your 6-digit code within the opening window e.g. 123456
5.
Input unit Primor RO
Turn the input unit clockwise within 3 seconds into opening position.
The lock is opened.
• An active time delay can be interrupted by pressing any key.

7
Primor 2000 / Level 5
04.05.2012
7 Power supply and battery change
The lock is power supplied by one 9 V block battery alkaline (no rechargeable batteries!). When battery voltage is insufcient,
after entering the code a warning tone occurs repeatedly and the red LED flashes alternately. Change the battery as quickly as
possible. The programmed codes stay valid during battery change.
Always dispose used batteries in an environmentally friendly way.
Fig. 1.: Input unit Primor RO
6 Testing the system (programme 5)
Press every number once. A functional key will be conrmed by a double signal. A key that was not identi-
ed is conrmed by a long signal and the functional test is aborted. The system has to be checked.
1. Press and hold the key “5“ until the red LEDs flash permanently. 5
2. Press every key in its order of appearance. 123.......90

8
Primor 2000 / Level 5
04.05.2012
Table of contents
Other Wittkopp Door Lock manuals