Witura WT-9001 IP65 User manual

W
WT
T-
-9
90
00
01
1
I
IP
P6
65
5
G
G
GS
S
SM
M
M
R
R
Re
e
em
m
mo
o
ot
t
te
e
e
C
C
Co
o
on
n
nt
t
tr
r
ro
o
ol
l
l
A
A
An
n
nd
d
d
A
A
Al
l
la
a
ar
r
rm
m
m
S
S
Sy
y
ys
s
st
t
te
e
em
m
m
User Manual
&
Setting Instructions
W
W
WI
I
IT
T
TU
U
UR
R
R
A
A
A
C
C
CO
O
OR
R
R
P
P
PO
O
OR
R
R
A
A
AT
T
TI
I
IO
O
ON
N
N
S
S
SD
D
DN
N
N
B
B
BH
H
HD
D
D

2
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
WT-9001 IP65 GSM REMOTE CONTROL AND ALARM SYSTEM
WIRING DIAGRAM DESCRIPTION

3
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Example of Trigger Input Connections
Example of Controlling Output Connections

4
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
1) 1 pc IP65 Enclosure
2) 1 pc WT-9001 Main Board with GSM Module mounted
3) 1 pc Power Adapter
4) 1 pc Battery Backup
5) 1 pc GSM Antenna
6) 1 pc LCD Display for Assisting in Programming
1. Introduction……………………………………………………………………………………………………………………5
2. Features…………………………………………………………………………………………………………………………5
3. Characteristic……………………………………………………………………………………………………………5
4. Installation Instruction………………………………………………………………………………………………8
5. WT-9001 IP65 Programming Instructions ………………………………………………………………11
5.1 Programming the Administrator Numbers ……………………………………………………………………11
5.2 Access Control for Administrator……………………………………………………………………………………12
5.3 Output Settings………………………………………………………………………………………………………………12
5.4 Input Settings…………………………………………………………………………………………………………………14
5.5 Alarm Settings………………………………………………………………………………………………………………19
5.6 Miscellaneous Settings…………………………………………………………………………………………………22
6. Technical Specifications…………………………………………………………………………………………………………..29
PACKAGE CONTENTS
CONTENTS

5
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
WITURA WT-9001 IP65 GSM Remote Control and Alarm System allow you to use your
mobile phone to monitor and control your business from any location. Its alarm facilities
provide a flexible way to distribute critical alarm information to any number of mobile
phone users.
More versatile than a pager system. WT-9001 IP65 provides detailed alarm messages,
secure alarm acceptance, full alarm reporting and even remote process control. This
allows user to rectify problems directly via their mobile phone within minutes of the
alarm occurring.
The WT-9001 IP65 can monitor 8 digital inputs. A SMS alarm message can be sent
when inputs exceed preset limits. The user can also interrogate the inputs through SMS
messaging. The WT-9001 IP65 also has 8 relay outputs which can be activated via
SMS and used to switch lamps, pumps, heaters etc. The WT-9001 IP65 is complete
with an LCD display, back up battery and built-in Dual Band or Quad Band Modem.
•More flexible than pager based systems
•Low set up and running costs
•Faster response to alarms and process disturbances
•Allows reduced manning levels
•Increased freedom of movements for users
•Reduces wasted traveling time responding to alarm events
•Provides more detailed information
•Easier monitoring of remote process
•Allows full remote control
WT-9001 is a versatile SMS alert device suited for most monitoring needs. It is simple
to use yet is packed with powerful functionalities to meet a wide ranging industrial and
commercial and residential applications
2. FEATURES
1. INTRODUCTION
3. CHARACTERISTIC

6
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Housed in the weather and desk proof IP 65 enclosure complete with internal industrial
modem, monitoring controller and flexible operating firmware. It is very easy to setup,
install and use.
Most equipment today does provide some form of alerting signal to interface to
monitoring devices from reporting of various malfunction or abnormalities. There are
various kinds of signal that the equipment can send out, most common of which are
opening or closure of one or more switch relay contact. UPS usually provide signals such
as incoming power fail, battery mode, battery level low, and switchover failure. An air
conditioner system may provide signals such as system on/ off, compressor over
temperature, low gas pressure, etc.
Equipments to be monitored are connected to WT-9001 using these alarm signaling
contacts. WT-9001 keeps a constant watch over all the contacts. Whenever any contact
input changes status (either from a close to open or from an open state to close state) it
is captured by WT-9001. It will then process the input according to the configuration
provided by the user. The correct SMS messages will be sent to 8 mobile phone users.
WT-9001 is so fast in capturing the change of status of any signaling contacts that no
event will be missed out up to 8 inputs can be monitored directly. The flexibility of WT-
9001 is in allowing remote query of input status using SMS.
To change contacting mobile phone number is also very easy. Authorize personal
remotely using SMS command to add, change or delete mobile phone number in WT-
9001.
WT-9001 is a 2 way device. Besides monitoring inputs and act upon such inputs it also
allow mobile phone users to compose SMS messages to it. When WT-9001 receives any
SMS, it will look its memory bank to see what it is supposed to do and action according.
No action SMS are ignored.
Up to 8 relays can turned on and off by messages received from mobile phone. Creating
action messages are done with the same ease as that of input monitoring
3.1 Standalone Operation
3.2 8 Digital Inputs
3.3 8 Digital Outputs

7
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Authorized groups can also query the status of an input or output. This is very useful
feature to determine the present status of an input or output. The enquirer need not
wait for an alarm to happen in order to receive the given I/O status.
Authorized users can send a SMS command to trigger on or off the digital output. Upon
receiving the command, WT-9001 will perform the instructed action. After the on or off
action is done, it will send a reply to the querying mobile phone as an acknowledgement,
There are 8 digital output that can be independently controlled.
WT-9001 has a feature to allow user to remotely add, change or delete any mobile
phone numbers in WT-9001 memory.
Re-assigning of operation personnel, a change of mobiles phone number is also common.
Rather than having to physically go to the installation site with a notebook computer, the
authorized personnel can perform the change from anywhere using mobile phone. Where
there are many installed sites, this feature saves time and afford.
Authorized mobile phone group can perform system check by sending a command to
WT-9001. If WT-9001 is switched on or working normally, it will reply to the querying
number.
Integral to the design of WT-9001 is a GSM 900/1800Mhz or GSM 850/1900Mhz
Industrial grade modem. Its capabilities and performance are highly optimized by the
operating firmware. Any change in the GSM signal and receiving conditions are detected
quickly and the software automatically takes care of signal errors
3.4 Querying Inputs And Outputs Status
3.5 Turning On/ Off Device Remotely
3.6 Remote Editing Of Mobile Phone Numbers
3.7 System Check
3.8 GSM Modem

8
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Besides running the necessary program to perform all the required functions, WT-9001
has diagnostic routines running alongside. Being a monitoring device, WT-9001 must
have a very high operating reliability and stability. Every section of WT-9001 is
monitoring each other. Should the modem fail to perform its required role, the controller
will interrogate and restart the modem.
For monitoring and remote control of equipments and machines that are able to provide
dry contract signals. 8 digital outputs with pulse functions extend control functions.
Suitable for door access control, On/Off equipment remotely, resetting of Routers,
Network switches etc. Some application examples are: -
Machines, Standby Power Generator, Electrical Panels, Pumps, Uninterruptable Power
Supplies, DC rectifier systems, Vending Machines, Fire Alarm Panels, Gas Monitoring
Systems, ATM Machines, Security Systems, Fishery, Cold rooms, HVAC systems, Door
Security, Network equipment and more.
Note: It is essential that you read the step by step instructions fully prior to installing
and programming the unit
4. INSTALLATION INSTRUCTION
4.1 Screw off the Front Case of WT-9001 IP65 Main Unit
3.9 Reliable Performance
3.10 Application

9
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Installing the SIM Card
Note: Installing the SIM Card. Please be sure the initial 4 digit PIN code of SIM card is
disabled. This can be done by placing it in an unlocked Mobile phone and first checking if
the SIM requested any PIN code. If this is the case the PIN code can be disabled using
the security settings on the phone.
Proceed as follows
1. Slide back the SIM door and lift it up
2. Slide the SIM card into the SIM door making sure that the clipped corner of the SIM
card lines up with the clipped corner of the SIM holder
3. Close the SIM door
4. Slide the SIM door to lock the SIM card in place
4.2 Installing Components: Antenna, LCD, Power Supply & SIM Card

10
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
You should install the WT-9001 in a place where there is GSM signal coming from the
operator you want to use. Check it with a phone before proceeding with the installation.
If you need to install the device in a place with little signal, you may consider using an
external antenna that we may supply as an option to be purchased separately with 5m
cable.
Once the WT-9001 GSM Intercom is turned on, you shall be able to see the system start
up on the LCD screen as shown below…
The system is searching for network…
Once the network is found, it will display OK
Attention: If the system doesn’t shows OK when searching the network, it could be the
SIM card not properly installed. Turn off the unit and check the SIM card, when it is
properly seated in place then reboot the system.
When the system is ready to use it will shows
WT-9001
Settings: >>>>
Search
Wait…
Search
OK
4.3 System Start Up
Signal Power
Battery

11
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
You can program the WT-9001 via SMS commands using your phone. Any programming
command sent by SMS must be in CAPITAL letters. The fields between square brackets
are parameters; do NOT enter the square brackets.When you send a command, you will
receive the answer for the first time even if your GSM number is not in the administrator
list. This happens because the WT-9001 recognizes any GSM number as administrator
and answers to it.
Attention: Please program the WT-9001 units systematically begin with
programming the administrator number
The 20 administrator numbers can be programmed with a text command via SMS.
Text Command:
*TEL[N]#XXXXXXXXXX
N stands for administrator number 1 - 20
XXXXXXXXXX stands for the phone number you want to program as administrator.
Please note that it is possible to program up to a maximum of 16 digits for a phone
number.
Example:
To program phone number 1111222233 as administrator into list number 1, you would
send the following SMS command to the unit.
*TEL1#1111222233
When the WT-9001 received the message, the LCD will display…
WT-9001
After the SMS command has been processed, the message icon will disappear and the
system will shows “OK” indicate the setting has changed.
5. WT-9001 IP65 PROGRAMMING INSTRUCTIONS (via SMS Only)
5.1 Programming the Administrator Number
Message
received

12
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
OK
WT-9001
And then the WT-9001 will reply a message back to you that the administrator number
has been added.
Example of Returned Message:
TEL1=1111222233
Note: Programming the administrator numbers is necessary in order to
operate all other functions and to receive text alerts when the relays
activated
Note: It is advised that the owner should set the system to allow programming
access for administrators only after programmed the Administrator numbers.
Sending SMS Command: *ANY?#1
Only the administrators in the list will have the access control to the system, any person
outside the list in this case will not have the authority to access the system and text
command sent to the system will be rejected.
To allow any person gain access to the system just send SMS Command: *ANY?#0
Note: Only Administrator number 1 and 2 may send this SMS command
The WT-9001 has 8 outputs that are connected to an on-board relay which can be
activated by sending an SMS command.
To activate any output relay, you can send a text command via SMS specifying the
output number and the number of seconds the output should stay on to the unit. It is
possible to set up to maximum of 65,535 seconds
5.2 Access Control For Administrator
5.3 OUTPUT Settings
5.3.1 Switch On the Output Relay For a Specific Time

13
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Text Command:
*RLY[N]#XXXXX
N stands for Output number 1 - 8
XXXXX stands for 5digits value: The number of seconds
Example:
To turn on the output relay number 5 for 1 hour, you can send the following text
message to the unit.
*RLY5#03600
Example of Returned Message:
RELAY5=03600
Note: Sending the following SMS Message to unit will switch off the relay
*RLY5#00000
To activate multiple output relays to stay on, you can send a text command via SMS
specifying the output number that should stay on to the unit.
Text Command:
*RLNU#XXXXXXXX
XXXXXXXX stands for 8digits value: ON (1) or OFF (0) for the 8Outputs
Example:
To switch on the output relay number 5, 6, 7, 8,you can send the following text
message to the unit.
*RLNU#00001111
Sending the following SMS Message to unit would mean all the relays will be switched
off.
*RLNU#00000000
The 1 indicates the ON command and the 0 (zero) indicates the OFF command
5.3.2 Switch Multiple Outputs Relays to Stay On

14
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
The unit can generate text alerts to all 20 of the administrator’s Mobile phone numbers
when the relay has turned off. To set the administrator to receive this alert, you would
send the following commands by SMS message to the unit.
Text Command:
*RETR#X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X;
X stands for position for 1 - 20 administrators with function value: 0(OFF), 1– 9
(number of text alerts)
Example:
To program the unit to generate 2 SMS to administrators 1, 2, 3, 4, 5 and 1 SMS to the
rest, you would send the following SMS message to the unit.
*RETR#2,2,2,2,2,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1;
Example of Returned Message:
RETR=2,2,2,2,2,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1;
One of the most important functions of WT-9001 is to receive alarms. In order to use
this function, you must turn on the function of the inputs and tell the WT-9001 which are
the recipient numbers and who should receive the alert message for the particular input.
To turn on the function of input, you can send the following commands by SMS message
to the unit.
Text Command:
*CTR[N]#X
N stands for number 1 - 8 of Input
X stands for ON (1) or OFF (0) value
5.4 INPUT SETTINGS
5.4.1 Turn On the Function of Inputs
5.3.3 SETTING THE RECIPIENT OF RELAY OFF ALERT

15
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Example:
To turn on input number 1,you can send the following text message to the unit.
*CTR1#1
Sending the following SMS Message to unit would mean input 1 will be turned off
*CTR1#0
The 1 indicates the ON command and the 0 (zero) indicates the OFF command
Every input can generate text alerts to all 20 of the administrator’s Mobile phone
numbers and this function can be changed at any time by sending the following
commands by SMS message to the unit.
Text Command:
*RER[N]#X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X;
N stands for input number 1- 8
X stands for position for 1 - 20 administrators with function value: 0(OFF), 1– 9
(number of text alerts)
Example 1:
Any alarm coming from Input 1 will generate 2 SMS to administrators 1, 2, 3 and 1 SMS
to the rest, you would send the following SMS message to the unit.
*RER1#2,2,2,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1;
Example of Returned Message:
RER1=2,2,2,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1;
Example 2:
Any alarm coming from Input 2 will generate 3 SMS to administrator 1, 2 SMS to
administrator 2, 3, 4 and 5, no SMS to the rest, you would send the following SMS
message to the unit.
*RER2#3,2,2,2,2,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0;
5.4.2 Setting the Recipient that will Received Alert Messages

16
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Example of Returned Message:
RER2=3,2,2,2,2,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0;
The Input Alert Message can be edited and programmed up to 100 characters long. You
can change the displayed text by sending the following commands by SMS message to
the unit.
Note: Only support normal abc/ ABC English text, no special characters
Text Command:
*STR[N]#XXXXX…
N stands for number 1 - 8 of Input
XXXXX… stands for the display text that you want to program
Example:
If you want the alert message to display “Garage Opened!” when input 1triggered;
you would send the following SMS message to the unit.
*STR1#Garage Opened!
The Input Alert Message can be edited and programmed up to 100 characters long. You
can change the displayed text by sending the following commands by SMS message to
the unit.
Note: Only support normal abc/ ABC English text, no special characters
Text Command:
*STO[N]#XXXXX…
N stands for number 1 - 8 of Input
XXXXX… stands for the display text that you want to program
Example:
If you want the alert message to display “Garage Closed!” when input 1triggered; you
would send the following SMS message to the unit.
*STO1#Garage Closed!
5.4.3 Editing the Input Alert Message For (When Input gets High Pulse)
5.4.4 Editing the Input Alert Message For (When Input returned to Normal)

17
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
An alert message will be sent when the increment of alarm counter reaches the alert
value (Default: 500). It is possible to set the alert value up to maximum value of
65535 times. To set the counter alert value of input, you can send the following
commands by SMS message to the unit.
Text Command:
*COA[N]#XXXXX
N stands for number 1 - 8 of Input
XXXXX stands for 5digits value: The number of times
Example:
Assume that you want it to send a counter alert message each time the input 1 has
triggered for 5 times, you would send the following SMS message to the unit.
*COA1#00005
All inputs can be programmed to behave differently, it can count the input active high
pulses, generate an alarm message or activate relay. To program the input, you can
send the following commands by SMS message to the unit.
Text Command:
*CTC[N]#F
N stands for number 1 - 8 of Input
F stands for input function 1 - 8
Function Descriptions
Function 1:
•Function as pulse counter
•Sends a counter alert message once alarm counter reaches the alert value
•Audible alarm will sound if the alarm function is turned on (*ALM[N]#1)
* For more details on function *ALM[N]# please refer to Alarm Settings
on page
5.4.5 Setting the Counter Alert Value For Inputs
5.4.6 Setting the Feature Of Input

18
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Function 2:
•Function as pulse counter
•Activate the output relay number (according to which input number applied)
to stay on
•Sends a counter alert message once alarm counter reaches the alert value
•Audible alarm will sound if the alarm function is turned on (*ALM[N]#1)
Function 3:
•Function as pulse counter
•Activate the output relay number (according to which input number applied)
to stay on
•Sends a programmable input alert message (*STR[N]#) once input triggered
•Sends a counter alert message once alarm counter reaches the alert value
•Audible alarm will sound if the alarm function is turned on (*ALM[N]#1)
Function 4:
•Function as pulse counter
•Activate the output relay number (according to which input number applied)
for 2 second and off
•Sends a counter alert message once alarm counter reaches the alert value
•Audible alarm will sound if the alarm function is turned on (*ALM[N]#1)
Function 5:
•Activates the output relay number (according to which input number applied)
with functions of *PWT[N]#and *PWK[N]#
•Sends a programmable input alert message (*STR[N]#) once input triggered
* For more details on functions of *PWT[N]#and *PWK[N]# please refer
to Miscellaneous Settings on page
Function 6:
•Function as pulse counter
•Activates the output relay number (according to which input number applied)
with functions of *PWT[N]#and *PWK[N]#
•Sends a counter alert message once alarm counter reaches the alert value
•Audible alarm will sound once alarm counter reached the alert value (if the alarm
function is turned on (*ALM[N]#1)
* For more details on functions of *PWT[N]#and *PWK[N]# please refer
to Miscellaneous Settings on page

19
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Function 7:
•Sends a programmable input alert message (*STR[N]#) once input triggered
Function 8:
•Function as pulse counter
•Sends a programmable input alert message (*STR[N]#) once input triggered
•Sends a programmable input alert message (*STO[N]#) once input returned to
normal
•Audible alarm will sound when input return to normal
Note: It is required to reset the Counter Alert Value (*CLA#) each time you change the
input function. For more details please refer to page 22
The system has the function to sound the connected audible siren when input triggered.
This output is available on the connection PIN3 and ground on the main board. To turn
On/Off this function, you can send the following SMS command to the unit.
Text Command:
*ALM[N]#X
N stands for Input number 1– 8
X stands for ON (1) or OFF (0) value
When *ALM1#1 is applied, means audible alarm will sound when Input 1 triggered.
When *ALM1#0 (Default) is applied, means audible alarm will not sound when Input 1
triggered.
The alarm siren can be set to determine how long the siren will remain active and this
can be done by sending the following SMS command to the unit.
Text Command:
*ALTM#XXXXX
XXXXX stands for 5digits value: The number of seconds (00000-65535)
5.5 ALARM SETTINGS
5.5.1 Turning the Audible Siren Functions On/Off When Inputs Triggered
5.5.2 Setting the Alarm Time For Audible Alarm (Default: 600 seconds)

20
WT
-
900
1
IP65
GSM Remote Control And Alarm System
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Example:
When *ALTM#03600 is applied, means the audible alarm will sound for 1 hour when
triggered
The system has the function to send a text alert and also sound the audible siren in the
event the main power is lost and the system is relying on battery back up.
It is also possible to activate and also deactivate this function by sending the unit a SMS
Message.
Text Command:
*ALAC#X
X stands for ON (1) or OFF (0) value
Whenever the *ALAC#1 command is activated and the power down alarm is on any of
the Administrators programmed to receive text alerts, will receive the following
messages from the unit in the event of power down and also when power is restored.
Power down and text alert received: ACP-OFF
Power restored and text alert received: ACP-ON
Whenever there is power failure, the unit can generate text alerts to all 20 of the
administrator’s Mobile phone numbers. To set the administrator to receive this alert, you
would send the following commands by SMS message to the unit.
Text Command:
*REAC#X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X;
X stands for position for 1 - 20 administrators with function value: 0(OFF), 1– 9
(number of text alerts)
Example:
To generate 2 SMS to administrators 1, 2, 3 and 1 SMS to the rest when AC failure, you
would send the following SMS message to the unit.
*REAC#2,2,2,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1;
5.5.3 Power Down Alarm
5.5.4 Anti-Theft Feature
Other manuals for WT-9001 IP65
1
Table of contents
Other Witura Security System manuals

Witura
Witura WT-1010C2 User manual

Witura
Witura WT-1011RC IP 65 User manual

Witura
Witura WT9002 User manual

Witura
Witura WT-1672B User manual

Witura
Witura WT-9001 IP65 User manual

Witura
Witura WT-1010SA User manual

Witura
Witura WT9002 User manual

Witura
Witura WT-1010C2 User manual

Witura
Witura WT-1010SA User manual

Witura
Witura WT-1672A Operating instructions