Witura WT-1011RC IP 65 User manual

W
WT
T-
-1
10
01
11
1R
RC
C
I
IP
P6
65
5
G
G
GS
S
SM
M
M
R
R
Re
e
em
m
mo
o
ot
t
te
e
e
C
C
Co
o
on
n
nt
t
tr
r
ro
o
ol
l
ll
l
le
e
er
r
r
A
A
An
n
nd
d
d
A
A
Al
l
la
a
ar
r
rm
m
m
S
S
Sy
y
ys
s
st
t
te
e
em
m
m
User Manual
&
Setting Instructions
W
W
WI
I
IT
T
TU
U
UR
R
R
A
A
A
C
C
CO
O
OR
R
R
P
P
PO
O
OR
R
R
A
A
AT
T
TI
I
IO
O
ON
N
N
S
S
SD
D
DN
N
N
B
B
BH
H
HD
D
D

2
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
1) 1 pc IP65 Enclosure
2) 1 pc WT-1011RC Main Board with GSM Module mounted
3) 1 pc Battery Backup
4) 1 pc GSM Antenna
1. Introduction………………………………………………………………………………………………………………3
2. Features………………………………………………………………………………………………………………………3
3. Characteristic……………………………………………………………………………………………………………3
4. Installation Instructions………………………………………………………………………………………………6
5. WT-1011RC Programming Instructions ……………………………………………………………9
5.1 Programming the Administrator Numbers ……………………………………………………………………9
5.2 Access Control for Administrator……………………………………………………………………………………10
5.3 Programming the Guest List………………………………………………………………………………………..…10
5.4 Output Settings………………………………………………………………………………………………………………11
5.5 Input Settings…………………………………………………………………………………………………………………15
5.6 Alarm Settings………………………………………………………………………………………………………………20
5.7 Miscellaneous Settings…………………………………………………………………………………………………23
5.8 Connection of RS-232 Cable for Programming………………………………………………………………28
6. Technical Specifications……………………………………………………………………………….……………29
CONTENTS
PACKAGE CONTENTS

3
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
WITURA WT-1011RC GSM Remote Controller and Alarm System allow you to use your
mobile phone to monitor and control your business from any location. Its alarm facilities
provide a flexible way to distribute critical alarm information to any number of mobile
phone users.
WT-1011RC provides detailed alarm messages, secure alarm acceptance, full alarm
reporting and even remote process control. This allows user to rectify problems directly
via their mobile phone within minutes of the alarm occurring.
The WT-1011RC can monitor 2digital inputs. A SMS alarm message can be sent when
inputs triggered. The user can also interrogate the inputs through SMS messaging. The
WT-1011RC also has 2heavy-duty relay outputs can be used to switch on any
application like lamps, pumps, heaters etc. Output Relay 1 can be switched ON for a
preset time by calling its cell phone number, there is no call charges incurred when
dialing the unit as it will recognize an authorized telephone number calling it and reject
the call without answering. Output Relay 2 can be programmed to switch on for a pre-
determined length of time by sending the WT-1011RC a text command.
More flexible than pager based systems
Low set up and running costs
Faster response to alarms and process disturbances
Allows reduced manning levels
Increased freedom of movements for users
Reduces wasted traveling time responding to alarm events
Provides more detailed information
Easier monitoring of remote process
Allows full remote control
WT-1011RC is a versatile SMS alert device suited for most monitoring needs. It is
simple to use yet is packed with powerful functionalities to meet a wide ranging
industrial and commercial and residential applications
2. FEATURES
1. INTRODUCTION
3. CHARACTERISTIC

4
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
Housed in the weather and desk proof IP65 enclosure complete with internal industrial
modem, monitoring controller and flexible operating firmware. It is very easy to setup,
install and use.
Most equipment today does provide some form of alerting signal to interface to
monitoring devices from reporting of various malfunction or abnormalities. There are
various kinds of signal that the equipment can send out, most common of which are
opening or closure of one or more switch relay contact. UPS usually provide signals such
as incoming power fail, battery mode, battery level low, and switchover failure. An air
conditioner system may provide signals such as system on/off, compressor over
temperature, low gas pressure, etc.
Equipments to be monitored are connected to WT-1011RC using these alarm signaling
contacts. WT-1011RC keeps a constant watch over all the contacts. Whenever any
contact input changes status (either from a close to open or from an open state to close
state) it is captured by WT-1011RC. It will then process the input according to the
configuration provided by the user. The correct SMS messages will be sent to 8 mobile
phone users.
WT-1011RC is so fast in capturing the change of status of any signaling contacts that no
event will be missed out up to 2 inputs can be monitored directly. The flexibility of WT-
1011RC is in allowing remote query of input status using SMS.
To change contacting mobile phone number is also very easy. Authorize personal
remotely using SMS command to add, change or delete mobile phone number in WT-
1011RC.
WT-1011RC is a 2 way device. Besides monitoring inputs and act upon such inputs it
also allow mobile phone users to compose SMS messages to it. When WT-1011RC
receives any SMS, it will look its memory bank to see what it is supposed to do and
action according. No action SMS are ignored.
3.1 Standalone Operation
3.2 2 Digital Inputs
3.3 2 Digital Outputs

5
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
Relay 1 can turned on for a preset time by calling its number and Relay 2 can be
activated by text messages from mobile phone. Creating action messages are done with
the same ease as that of input monitoring.
Authorized groups can also query the status of an input or output. This is very useful
feature to determine the present status of an input or output. The enquirer need not
wait for an alarm to happen in order to receive the given I/O status.
Authorized users can send a SMS command to trigger on or off the digital output. Upon
receiving the command, WT-1011RC will perform the instructed action. After the on or
off action is done, it will send a reply to the querying mobile phone as an
acknowledgement.
WT-1011RC has a feature to allow user to remotely add, change or delete any mobile
phone numbers in WT-1011RC memory.
Re-assigning of operation personnel, a change of mobiles phone number is also
common. Rather than having to physically go to the installation site with a notebook
computer, the authorized personnel can perform the change from anywhere using
mobile phone. Where there are many installed sites, this feature saves time and afford.
Authorized mobile phone group can perform system check by sending a command to
WT-1011RC. If WT-1011RC is switched on or working normally, it will reply to the
querying number.
Integral to the design of WT-1011RC is a GSM 850/900/1800/1900Mhz Industrial
grade modem. Its capabilities and performance are highly optimized by the operating
firmware. Any change in the GSM signal and receiving conditions are detected quickly
and the software automatically takes care of signal errors
3.4 Querying Inputs And Outputs Status
3.5 Turning On / Off Device Remotely
3.6 Remote Editing Of Mobile Phone Numbers
3.7 System Check
3.8 GSM Modem

6
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
Besides running the necessary program to perform all the required functions, WT-
1011RC has diagnostic routines running alongside. Being a monitoring device, WT-
1011RC must have a very high operating reliability and stability. Every section of WT-
1011RC is monitoring each other. Should the modem fail to perform its required role,
the controller will interrogate and restart the modem.
For monitoring and remote control of equipments and machines that are able to provide
dry contract signals. 2 digital outputs with pulse functions extend control functions.
Suitable for door access control, On/Off equipment remotely, resetting of Routers,
Network switches etc. Some application examples are: -
Machines, Standby Power Generator, Electrical Panels, Pumps, Uninterruptable Power
Supplies, DC rectifier systems, Vending Machines, Fire Alarm Panels, Gas Monitoring
Systems, ATM Machines, Security Systems, Fishery, Cold rooms, HVAC systems, Door
Security, Network equipment and more.
IMPORTANT!
Please read through the instruction manual before you start to install and program the
device.
If you are unsure how to connect the device you wish to control please refer to a qualified
person.
Requirements:
- The WT-1011RC requires a 15 volt DC power supply capable of providing a minimum current of
1500mA, typical current consumption is 60mA
- A mobile phone SIM card with sufficient credit to send confirmation text messages when
programming the WT-1011RC unit. Note: The WT-1011RC identifies only 3V SIM card
3.9 Reliable Performance
3.10 Application
4. INSTALLATION INSTRUCTION

7
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
Installation:
Installing the SIM Card
Note: Installing the SIM Card. Please be sure the initial 4 digit PIN code of SIM card is disabled.
This can be done by placing it in an unlocked Mobile phone and first checking if the SIM requested
any PIN code. If this is the case the PIN code can be disabled using the security settings on the
phone.
Proceed as follows
1. Slide back the SIM door and lift it up
2. Slide the SIM card into the SIM door making sure that the clipped corner of the SIM card lines
up with the clipped corner of the SIM holder
3. Close the SIM door
4. Slide the SIM door to lock the SIM card in place
Power Up the Device
Connect a 15 volt DC power supply to terminal 3 & 4 ensuring positive is connected to terminal
3, switch on the power supply, the power LED will lit indicating power is present, the network
LED indicator will initially flash quickly, once logged onto the network it will flash more slowly
approximately every 3 to 4 seconds
Note: You should install the WT-1011RC in a place where there is GSM signal coming from the
operator you want to use. Check it with a phone before proceeding with the installation. If you
need to install the device in a place with little signal, you may consider using an external antenna
that we may supply as an option to be purchased separately with 5m cable.
Input 15VDC Power
here
Power Switch
Insert SIM card
here
Install Antenna
here
Connect to Battery
Back-u
p

8
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
Connection Details:
If you are unsure how to connect the device you wish to control please refer to a qualified
person.
Port Descriptions
1 +12 volts DC Output Audible Alarm Output
2 - 12 volts DC Output
3 +15 volts DC Input a 15 volts DC power that capable of
providing a current of 1.5 Amp
4 - 15 volts DC
5 +5 volts DC output Auxiliary 5 volts DC Output can be used to
trigger the inputs
6 Input 2 (IN2) A Standard +5V TTL signal will trigger this
Input
7 Ground (COM)
8 Input 1 (IN1) A Standard +5V TTL signal will trigger this
Input
9 Ground (COM)
10 NORMALLY OPEN (N.O) OUTPUT RELAY 2
(Can be Switched ON/OFF by SMS)
11 COMMON (COM)
12 NORMALLY CLOSED (N.C)
13 NORMALLY OPEN (N.O) OUTPUT RELAY 1
(Can be Switched ON by Caller ID)
14 COMMON (COM)
15 NORMALLY CLOSED (N.C)
1 2 3 4 6 7 8 9
NCNO C
15VDC
Power
Input
OUTPUT RELAY 2
10 11
12VDC
Audible
Alarm
Output
INPUT 2 INPUT 1
+-IN2
12 13 14 15
IN1
COM
COM
NO C NC
OUTPUT RELAY 1
5
+
+5VDC
Output
+-

9
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
Example of Input & Output Connections
You can program the WT-1011RC via SMS commands using your phone. Any
programming command sent by SMS must be in CAPITAL letters. The fields between
square brackets are parameters; do NOT enter the square brackets. When you send a
command, you will receive the answer for the first time even if your GSM number is not
in the administrator list. This happens because the WT-1011RC recognizes any GSM
number as administrator and answers to it.
Attention: Please program the WT-1011RC unit systematically begin with programming the
administrator number.
The 8 administrator numbers can be programmed with a text command via SMS.
Text Command:
*TEL[N]#XXXXXXXXXX
N stands for administrator number 1 - 8
XXXXXXXXXX stands for the phone number you want to program as administrator.
1 2 3 4 6
7
8
9
NCNO C
15VDC
Power
Input
OUTPUT RELAY 2
10
11
INPUT 2 INPUT 1
+-IN2
12
13 14 15
IN1
COM
COM
NO C NC
OUTPUT RELAY 1
LIGHT
110VAC
HEATER
110VAC
+5VDC
12VDC
Audible
Alarm
Output
+-
5
+
+5VDC
Output
5. WT-1011RC PROGRAMMING INSTRUCTIONS (via SMS Only)
5.1 Programming the Administrator Number

10
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
Please note that it is possible to program up to a maximum of 16 digits for a phone
number.
Example:
To program phone number 1111222233 as administrator into list number 1, you would
send the following SMS command to the unit.
*TEL1#1111222233
After sending the above command, the WT-1011RC will reply a message back to you
that the administrator number has been added.
Example of Returned Message:
#TEL1=1111222233
Note: It is advised that the owner should set the system to allow programming
access and remote control of Output Relay 1 for administrators only after
programming the Administrator numbers.
Sending SMS Command: *ANY?#1
Only the administrators in the list will have the authority to access the system and
remote control of Output Relay 1 by calling its number, any person outside the list in
this case will not have the authority to access the system and text command sent to the
system will be rejected.
To allow any person gain access to the system just send SMS Command: *ANY?#0
Note: Only Administrator number 1 and 2 may send this SMS command
The system allows the phone numbers in the Guest List as authorized user to operate
the output relays when calling its number. When the system received a phone call from
the Guest List, it will activate the output relays without answering the call therefore it is
free of charge. If it is not a registered user of the Guest List the call is rejected and the
output relays will never trigger. It is possible to program up to 100 phone numbers to be
authorized users in the Guest List of the unit and this can be done by sending the
following SMS to the unit.
5.2 Access Control For Administrators
5.3 Programming the Guest List

11
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
Text Command:
*BOOK#nnXXXXXXXX
nn stands for the position number 00 - 99
XXXXXXXX stands for last 8-digits of a phone number
Example:
To program phone number 1234567890 as Guest into the list, you would send the
following SMS command to the unit.
*BOOK#0034567890
Example of Returned Message:
#WHL00-OK
The WT-1011RC has 2outputs that are connected to an on-board relay. Each output
relay can be operated independently.
Output Relay 1can be switched ON for a preset time with Caller ID as it can recognize
the incoming number, if it is an authorized user in the Administrator list it will reject the
call without answering and switch on the device connected to it.
Output Relay 2can be switch on for a pre-determined length of time by a simple text
message.
This command allows you to reset the default latching time of relay. To reset the default
value, you can send the following text command via SMS specifying the number of
seconds the output relay 1 should stay on when it is called. It is possible to set up to
maximum of 65,535 seconds. Default: 1 second
Text Command:
*GOT1#XXXXX
XXXXX stands for 5digits value: The number of seconds
Example:
To set the output relay 1 to stay on for 15 minutes each time it is called, you would send
the following command to the unit.
*GOT1#00900
5.4 OUTPUT Settings
5.4.1 Reset the Default Latching Time of Relay 1

12
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
Example of Returned Message:
#GOT1=00900
To activate output relay 2, you can send a text command via SMS specifying the number
of seconds the output should stay on to the unit. It is possible to set up to maximum of
65,535 seconds.
Text Command:
*RLY2#XXXXX
N stands for output relay number 2
XXXXX stands for 5digits value: The number of seconds
Example:
To turn on the output relay number 2 for 1 hour, you can send the following text
message to the unit.
*RLY2#03600
Example of Returned Message:
#RELAY2=03600
Note: Sending the following SMS Message to unit will switch off the relay
*RLY2#00000
The unit can generate text alerts to all 8 administrator’s Mobile phone numbers when the
relay has turned on or off. To set the administrator to receive this alert, you would send
the following commands by SMS message to the unit.
Text Command:
*RETR#XXXXXXXX
X stands for position for 1 - 8 administrators with function value: 0(OFF), 1– 9
(number of text alerts)
Example:
To program the unit to generate 2 SMS to administrators 1, 2, 3, 4 and 5 only, you
would send the following SMS message to the unit.
5.4.2 Switch On the Output Relay
2
For a Specific Time (By SMS)
5.4.3 Setting the Recipient of Relay Off Alert

13
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
*RETR#22222000
Example of Returned Message:
#RETR=22222000
This function allows the second relay to latch at a specific time (GOTX) later after the
first relay has latched and when the first relay has switched off the second relay will
switch off after a specific time (GOTY).
Text Command to Enable this Function:
*FTRY#2
Text Command to Enable the normal Function (5.3.1):
*FTRY#1
Example:
To program the device so that when you latched relay 1, relay 2 will latch 5 seconds
(GOTX) later.
*GOTX#00005
Example of Returned Message:
#GOTX=00005
Example:
To program the device so that when the relay 1 closes, relay 2 will closes
10 seconds (GOTY) later.
*GOTY#00010
Example of Returned Message:
#GOTY=00010
Note: When using this function, the *GOTX# delay time value you programmed must be
smaller than the latching time of output relay 1 (*GOT1#) otherwise the system will return an
error message.
5.4.4 Follow function for Output Relays

14
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
The output relay 2 can be programmed to operate at a programmable time. To
program this function, you can send the following commands by SMS message to the
unit.
Text Command to Enable this Function:
*FTRY#3
Note: When this function enabled, functions related to activation of output relay 2 will be disabled
and activation of output relay 2 via SMS will be rejected.
Text Command to Enable the normal Function (5.3.1):
*FTRY#1
Text Command to set the time:
*TSET#SS:MM:HH;
HH = hours, MM = minutes and SS = seconds
Example:
Assume it is 8:30am, you would send following SMS message to the unit.
*TSET#00:30:08;
Text Command to set the Operating time for the outputs:
*SMW#SS,MM,HH,TTTTT,G,R;
HH = hours (2 digits)
MM = minutes (2 digits)
SS = seconds (2 digits)
TTTTT = turn on time in seconds (5 digits)
G= group number 1-8
R= 2 (relay 2)
Example1:
Assume you want output relay 2 to turn on for 30 seconds on 5:30pm, you would send
following SMS message to the unit.
*SMW#00,30,17,00030,1,2;
Example of Returned Message:
#SMW=00,30,17,00030,1,2;
5.4.5 Setting the Operating Time for Output Relay
2

15
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
One of the most important functions of WT-1011RC is to receive alarms. In order to use
this function, you must turn on the function of the inputs and tell the WT-1011RC which
are the recipient numbers and who should receive the alert message for the particular
input.
To turn on the function of input, you can send the following commands by SMS message
to the unit.
Text Command:
*CTR[N]#X
N stands for number 1 - 2 of Input
X stands for ON (1) or OFF (0) value
Example:
To turn on input number 1,you can send the following text message to the unit.
*CTR1#1
Returned Message:
#INCTR1=ON
Sending the following SMS Message to unit would mean input 1 will be turned off
*CTR1#0
Returned Message:
#INCTR1=OFF
The 1 indicates the ON command and the 0 (zero) indicates the OFF command
Every input can generate text alerts to all 8 administrator’s Mobile phone numbers and
this function can be changed at any time by sending the following commands by SMS
message to the unit.
Text Command:
*RER[N]#XXXXXXXX
5.5 INPUT SETTINGS
5.5.1 Turn On the Function of Inputs
5.5.2 Setting the Alert Message Recipients

16
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
N stands for input number 1- 2
X stands for position for 1- 8administrators with function value: 0(OFF), 1– 9
(number of text alerts)
Example 1:
Any alarm coming from Input 1 will generate 2 SMS to administrators 1, 2, 3 and 1 SMS
to the rest; you would send the following SMS message to the unit.
*RER1#22211111
Example of Returned Message:
#RER1=22211111
Example 2:
Any alarm coming from Input 2 will generate 3 SMS to administrator 1, 2 SMS to
administrator 2, 3, 4 and 5, no SMS to the rest; you would send the following SMS
message to the unit.
*RER2#32222000
Example of Returned Message:
#RER2=32222000
The Input Alert Message can be edited and programmed up to 40 characters long. You
can change the displayed text by sending the following commands by SMS message to
the unit. Note: Only support normal abc/ABC English text, no special characters.
Text Command:
*STR[N]#XXXXX…
N stands for number 1 - 2 of Input
XXXXX… stands for the display text that you want to program
Example:
If you want the alert message to display “Garage Opened!” when input 1triggered;
you would send the following SMS message to the unit.
*STR1#Garage Opened!
Example of Returned Message:
#String1:<Garage Opened!>
5.5.3 Editing the Input Alert Message For (When Input gets High Pulse)

17
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
The Input Alert Message can be edited and programmed up to 40 characters long. You
can change the displayed text by sending the following commands by SMS message to
the unit. Note: Only support normal abc/ABC English text, no special characters.
Text Command:
*STO[N]#XXXXX…
N stands for number 1 - 2 of Input
XXXXX… stands for the display text that you want to program
Example:
If you want the alert message to display “Garage Closed!” when input 1triggered; you
would send the following SMS message to the unit.
*STO1#Garage Closed!
Example of Returned Message:
#STRALM1:<Garage Closed!>
An alert message will be sent when the increment of alarm counter reaches the alert
value (Default: 500). It is possible to set the alert value up to maximum value of
65,535 times. To set the counter alert value of input, you can send the following
commands by SMS message to the unit.
Text Command:
*COA[N]#XXXXX
N stands for number 1 - 2 of Input
XXXXX stands for 5digits value: The number of times
Example:
Assume that you want it to send a counter alert message each time the input 1 has
triggered for 5 times, you would send the following SMS message to the unit.
*COA1#00005
Example of Returned Message:
#COA1=00005
5.5.4 Editing the Input Alert Message For (When Input returned to Normal)
5.5.5 Setting the Counter Alert Value For Inputs

18
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
All inputs can be programmed to behave differently, it can count the input active high
pulses, generate an alarm message or activate relay. To program the input, you can
send the following commands by SMS message to the unit.
Text Command:
*CTC1#F1
*CTC2#F2
*CTC1# stands for input number 1
*CTC2# stands for input number 2
F1 stands for selectable input function 1 – 2
F2 stands for selectable input function 1 - 8
Input 1 Selectable Function Descriptions (F1):
Function 1:
Function as pulse counter
Function 2:
Function as pulse counter
Generates a programmable input alert message (*STR1#) once input triggered
Generates a programmable input alert message (*STO1#) once input returned to
normal
Input 2 Selectable Function Descriptions (F2):
Function 1:
Function as pulse counter
Function 2:
Function as pulse counter
Activates the output relay 2 to stay ON
Sends a counter alert message once alarm counter reaches the alert value
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
* For more details on function *ALM[N]# please refer to Alarm Settings on page
5.5.6 Setting the Feature of Input

19
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
Function 3:
Function as pulse counter
Activates the output relay 2 to stay ON
Sends a programmable input alert message (*STR2#) once input triggered
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
Function 4:
Function as pulse counter
Activates the output relay 2 for 2 seconds
Sends a programmable input alert message (*STR2#) once input triggered
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
Function 5:
Function as pulse counter
Activates the output relay 2 with function *PWT2# and *PWK2#
Sends a programmable input alert message (*STR2#) once input triggered
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
* For more details on functions of *PWT[N]# and *PWK[N]# please refer to Miscellaneous
Settings on page
Function 6:
Function as pulse counter
Activates the output relay 2 with function *PWT2# and *PWK2#
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
Function 7:
Function as pulse counter
Sends a programmable input alert message (*STR2#) once input triggered
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
Function 8:
Function as pulse counter
Sends a programmable input alert message (*STR2#) once input triggered
Sends a programmable input alert message (*STO2#) once input returned to
normal
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
Example:
Assume that you want to use input 1 for pulse counter only; you would send the
following SMS message to the unit.

20
WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
*CTC1#1
Example of Returned Message:
#CTC1=<1>
Note: Only Input 1 may apply function F1 where only 2 selectable functions available. Only Input
2 may apply function F2 where 8 selectable functions are available.
The system has the function to sound the connected audible siren when input triggered.
This output is available on PIN1 and PIN2 of the connector block. To turn On/Off this
function, you can send the following SMS command to the unit.
Text Command:
*ALM[N]#X
N stands for Input number 1– 2
X stands for ON (1) or OFF (0) value
When *ALM1#1 is applied, means audible alarm will sound when Input 1 triggered.
When *ALM1#0 (Default) is applied, means audible alarm will not sound when Input 1
triggered.
The alarm siren can be set to determine how long the siren will remain active and this
can be done by sending the following SMS command to the unit.
Text Command:
*ALTM#XXXXX
XXXXX stands for 5digits value: The number of seconds (00000-65535)
Example:
When *ALTM#03600 is applied, means the audible alarm will sound for 1 hour when
triggered
5.6 ALARM SETTINGS
5.6.1 Turning the Audible Siren Functions On/Off When Inputs Triggered
5.6.2 Setting the Alarm Time For Audible Alarm (Default: 600 seconds)
Table of contents
Other Witura Security System manuals

Witura
Witura WT-1010SA User manual

Witura
Witura WT9002 User manual

Witura
Witura WT-1672B User manual

Witura
Witura WT-1010SA User manual

Witura
Witura WT9002 User manual

Witura
Witura WT-9001 IP65 User manual

Witura
Witura WT-1010C2 User manual

Witura
Witura WT-1010SA User manual

Witura
Witura WT-9001 IP65 User manual

Witura
Witura WT-1010C2 User manual
Popular Security System manuals by other brands

Chamberlain
Chamberlain RWV400R Setup guide

My ADT
My ADT Ademco Vista-10P quick guide

Sargent
Sargent Stinger 310 Operation and installation manual

SecurityMan
SecurityMan IWATCHALARMD user guide

Protect America
Protect America Simon XT Installation manual and user's guide

Solon
Solon Defender AL00002 quick start guide