Wolf ICON Q User manual

INSTRUCTION MANUAL
ENGLISH V1
www.wolnt.com
WIDE TRANSMISSION
RANGE
RUMBLE
ALERT
HUBB
LINK
GLOBAL
MUTE
HIGH VISIBILITY
LEDS
LONG BATTERY
LIFE

2
CONTENTS
FEATURES 3
INSERTING BATTERIES 4
BATTERY LEVEL 4
POWER ON 4
RUBBER SOCKET HOLDERS 4
CONTROL KNOBS 5
DROPBACK DETECTION 5
LOCAL MUTE 5
LOCAL UNMUTE 5
PAIRING 5
FACTORY DEFAULT 5
RECOIL ELIMINATION 6
ALERTS 6
LED ILLUMINATION COLOURS 6
NIGHTLIGHT LED COLOUR 7
NIGHTLIGHT LED BRIGHTNESS 7
IQ PORT 7
STAINLESS STEEL STUD WITH LOCKING NUT 7
SMART LED PORT 7
ADJUSTMENT OF BITE ALARM
CONTROLS FROM HUBB 8
ROLLER SENSITIVITY SETTING LEVELS 8
LED ILLUMINATION COLOURS 8
BITE LED BRIGHTNESS 8
ALERT TIMEOUT 8
ALERT VOLUME 9
ALERT TONE 9
NIGHTLIGHT SETTINGS 9
BATTERY LEVEL INDICATION 9
RANGE TEST 9
MUTE 9
ADJUSTMENT OF BITE ALARM
CONTROLS FROM QrHUBB 10
LED ILLUMINATION COLOURS 10
TONE SETTING 10
BATTERY LEVEL INDICATION 10
RADIO SIGNAL STRENGTH 10
BIVVY LIGHT LINK 10
IQ PORT ON/OFF 10
ANTI-THEFT 10
MUTE 10
OFF POSITION
MOISTURE OUTLET
NIGHT LIGHT
IQ PORT
STAINLESS LOCKING NUT
STAINLESS STUD
SMART LED PORT
COMPRESSION WASHER
ISOTOPE SLOTS
LEDLED
NON-SLIP RUBBER GRIP
AND ROD PROTECTOR NON-SLIP RUBBER GRIP
AND ROD PROTECTOR
SPEAKER
SENSITIVITY Dial
8 SETTINGS VOLUME DIAL
MENU BUTTON
TONE DIAL
PAIR/MUTE BUTTON

3
FEATURES
•
High Sensitivity Roller Wheel
•
Roller Wheel Detection - 8 Sensitivity Levels, expandable to
16 via HUBB link
•
Dropback Differentiation
•
Recoil Elimination
•
High Visibility Dual Bite LED’s - 4 Changeable Colours -
Green, Blue, Yellow or Red
•
LED’S Indicates Forward and Backward - Flashes on
dropback
•
LED’S Time adjustable via HUBB and Stealth mode
(LED’S Off)
•
Piezo Speaker
•
Auto Night Light - 4 Changeable Colours and Auto Level
Adjustment & Manual Level Adjustment via HUBB
•
Smart Indicator Port - Smart LED Drive, colour change on
bite detection
•
IQ Port - Links other ICON Accessories
•
HUBB/Qr HUBB Link - Receives and Transmits Commands
to HUBB
•
Pairing Button
•
Menu Button
•
Extreme Transmit/Receive Range 2km line of sight
•
Fully Sealed Water Resistant Electronics
•
Battery Level Indication
•
Indication type - Event sent to HUBB
•
Mute - 60/30 Seconds
•
On/Off - Sensitivity Dial
•
Hard Case
•
Non-Slip Rubber Grip & Rod Protectors
•
Stainless Steel Stud, Locking Nut & Compression Washer
•
Battery Life - 1000 hrs on Standby
•
Beta Light Slots x 2 - Size 6mm x 2mm
•
Rubber Socket Covers
•
Range Test
•
Power Down Alert To HUBB - Anti Theft
•
LED’s Brightness - The brightness of the LED’s can be
adjusted for different fishing situations
•
Volume Settings - Adjustable from Alarm & HUBB
•
Tone Settings - Adjustable from Alarm & HUBB
•
Sensitivity Settings - Adjustable from Alarm & HUBB
•
Tone difference - Run Forward & Dropback
•
Latching Run Time - 30 Seconds Adjustable via HUBB
•
Low power mode is available when not paired to HUBB only.
After HUBB pairing LP mode can be re-enabled by a hard
reset of the Bite Alarm
•
Warranty 3 Years - 4th Year Free
Register you ICON at www.wolfint.com.

4
To insert batteries use a Philips screwdriver and open
2 screws on battery compartment. When inserting new
batteries always replace all of them and turn off Alarm
before replacing. After use of Alarm in damp conditions
leave to dry out somewhere warm before packing away
and if not going to be used for a while it is recommended
to remove batteries in case of leakage. Be careful when
attaching Alarm to banksticks, buzz bars etc. and avoid
over-tightening. See website for full care advice and
instructions.
BATTERY LEVEL
The Battery Level of the
Bite Alarm can be
displayed by pressing .
To power up the
Bite Alarm, turn the
sensitivity knob away
from the Off position.
On start-up the battery
level is indicated.
To turn off the Bite
Alarm, switch the
sensitivity knob to Off.
Await the shutdown
tone to confirm.
NOTE: Hard case will
not shut off Alarm.
INSERTING BATTERIES POWER ON
3 AA 1.5v
Batteries
Battery
Cover
RUBBER SOCKET HOLDERS
When IQ Port or Smart LED Port are
not being used the rubber socket
holders should be pressed into ports.
When not needed they should be
pressed into the socket holders on
reverse of Alarm.
Good battery level
OK battery level
Bad battery level

5
LOCAL UN-MUTE
The Bite Alarm can be un-muted after it has been muted.
A single press of the button will un-mute the Bite Alarm.
PAIRING
When the receiver device is ready for pairing with HUBB
(see receiver device instructions), press and hold the
button until indicator LED turns Blue then release Button, this
will initiate pairing.
FACTORY DEFAULT
To reset the Bite Alarm to factory settings, and remove all
user data, hold the button while powering on the Bite
Alarm. After the LED’s illuminate, release the button. A
tone will play to confirm the reset.
LOCAL MUTE
The Bite Alarm can be temporarily muted by pressing the
button. Multiple presses of the button achieve
different actions.
BUTTON PRESS DESCRIPTION
1 X The Bite Alarm is muted for 30 seconds.
2 X The Bite Alarm is muted for 60 seconds.
3 X The Bite Alarm is not muted.
CONTROL KNOBS
The Bite Alarm control knobs can be used to adjust various
settings.
The sensitivity knob adjusts the amount of line
travel before an alert is triggered. There is also an
Off position to turn the Bite Alarm off. 8 Sensitivity
Levels, expandable to 16 via HUBB link. 2mm,
6mm, 11mm, 17mm, 25mm, 34mm, 61mm, 101mm.
*Additional HUBB Settings 4mm, 8mm, 16mm,
20mm, 30mm, 40mm, 80mm & 100mm.
The volume knob adjusts the volume
of the alerts on the Bite Alarm.
The tone knob adjusts the pitch of the alerts on
the Bite Alarm.
DROPBACK DETECTION
During a dropback detection, a two tone signal is triggered
and the LED’s should flash.

6
LED ILLUMINATION COLOURS
By pressing and holding the menu button the
configuration menu can be entered, indicated by a
special tone.
While in the
configuration menu
the volume knob
adjusts the colour of
the LED colours.
4 colours are
available:
Blue
Yellow
Green
Red
Stealth Mode (Off)
ALERTS
ALERT
TYPE LED INDICATION SOUND
Forward
Solid Alert Colour
Single Tone at user
selected pitch.
Dropback
Flashing Alert Colour
Tone at alternating pitch.
IQ Empty
IQ Trigger
Solid Alert Colour
Piercing security tone.
Battery
Critical
Flashing Red
No tone played.
RECOIL ELIMINATION MENU BUTTON
The Bite Alarm includes Recoil Elimination. The alarm will only
sound if line moves the distance set by the sensitivity dial in
one direction only. If it moves forward and then drops back
immediately as in windy conditions, the alarm won’t sound.
For a given distance of line travel 4mm extra in the opposite
distance is needed before an alert is triggered.

7
LED ILLUMINATION BRIGHTNESS
While in the configuration menu the pressing the Mute
button toggles the LED and Nightlight brightness high/low.
Modes Selectable:
Bite LED 100% Nightlight 100%
Bite LED 10% Nightlight 100%
Bite LED 100% Nightlight 10%
Bite LED 10% Nightlight 10%
NIGHTLIGHT LED COLOUR
While in the
configuration menu
the Tone knob
adjusts the colour
of the Nightlight
LED. There are 4
selectable colours:
Blue - Yellow -
Green - Red - Off.
STAINLESS STEEL STUD, LOCKING NUT
& COMPRESSION WASHER
Incorporates a 3/8”
stainless steel stud
with locking nut and
compression washer
for attaching the alarm
to your buzz bar or
bankstick. Be careful
when attaching Alarm
to banksticks, buzz
bars etc. and avoid
over-tightening.
IQ PORT
SMART LED PORT
Link to other wired ICON accessories.
Smart LED Drive. Colour matching LEDs and 2 options,
*when used with WOLF Indicators only. Also drives some
3rd party indicators.

8
4 Colours: Blue - Yellow - Green -
Red - Stealth Mode (Off)
ADJUSTMENT OF BITE ALARM
CONTROLS FROM HUBB
DEVICE MENU
When the HUBB has been paired with Alarms press the
corresponding Alarm channel to change any settings. Press
and hold channel button until ‘Device Menu’ is shown on
screen.
On activation of the bite Alarm the
tone is replicated on the HUBB
and the HUBB LED’s replicate the
alert colour shown on the bite
Alarm. Depending on the HUBB’s
settings, the HUBB will also vibrate
on alert.
When ‘Device Menu’ is shown, use OK button to enter sub
menu.
Go to ‘Sensitivity’ to adjust the connected bite Alarm line
sensitivity. When confirming this option a message will be
sent to the bite Alarm, if successful you will be notified on
screen.
ROLLER SENSITIVITY SETTING LEVELS
8 Sensitivity Levels, expandable to
16 via HUBB Link
2mm, 6mm, 12mm, 18mm, 25mm,
35mm, 60mm or 100mm.
Additional Sensitivity Levels
4mm, 8mm, 16mm, 20mm,
30mm, 40mm, 80mm or 300mm.
LED ILLUMINATION COLOURS
BITE LED BRIGHTNESS
ADVANCED MENU
ALERT TIMEOUT
Go to ‘Alert Colour’ to change the
colour used to display alerts on
the bite Alarm and HUBB.
Go to ‘LED Brightness’ to change
the brightness of the LED’s
displayed on the bite Alarm.
Go to ‘Alert Timeout’ to adjust the
time that the LED remains turned
on after an alert on the bite
Alarm.
60 seconds / 30 seconds / 20
seconds / 10 seconds /
5 seconds
Use the back button to leave
‘Device Menu’ and go ‘Advanced
Menu’ and use OK button to enter
this menu.
< Device Menu >
[Enter]
< Sensitivity >
12 mm
< Alert Colour >
Blue
< LED Brightness>
73%
< Advanced Menu >
[Enter]
< Alert Timeout >
30 secs

9
ALERT VOLUME
ALERT TONE
NIGHTLIGHT SETTINGS
In ‘Advanced Menu’ go ‘Alert
Volume’ to adjust the volume of
the bite Alarm alert.
In ‘Advanced Menu’ go ‘Alert
Tone’ to adjust the pitch on the
Alarm and the HUBB.
In ‘Advanced Menu’ go ‘Nightlight
Config’. Find the first option titled
‘Nightlight Brightness’ and adjust
to manual setting.
Go to option ‘Nightlight Brightness’ and adjust as desired.
Go to option ‘Nightlight Colour’ and adjust as desired.
Colours available:
Red - Green - Blue - Yellow and Off.
Go to ‘Nightlight to Port’. When this option is turned on the
Nightlight colour is copied to any connected Wolf hanger or
swinger.
DEVICE STATUS
MUTE
Use the back button to leave ‘Advanced Menu’ and navigate
to the option titled ‘Device Status’ and enter sub menu using
OK button.
ANTI-THEFT
When turning off the connected Alarm, a tone is played on
the Alarm and HUBB for theft prevention.
RANGE TEST
Navigate to the option ‘Range
Test’ and use the OK button to
begin the test. When a connection
is established the HUBB will
report the signal strength of
the connected Alarm and also
indicates that the LED is working.
BATTERY LEVEL INDICATION
Navigate to the option ‘Battery
Level’. This provides a detailed
measurement of the Alarms
battery level.
Pressing the Mute button once should mute all connected
Alarms. On activation neither the HUBB or Alarm will play a
tone. A double press of the Mute button will undo the mute
on the HUBB and Alarms.
< Volume >
50%
< Alert Tone >
28%
< Nightlight Con >
[Enter]
< Battery Level >
97%
< Range Test >
[Start]

10
MUTE
Pressing the Mute button once should mute all connected
Alarms. On activation neither the Qr HUBB or Alarm should
play a tone. A double press of the Mute button should undo
the mute on the Qr HUBB and Alarms.
ANTI-THEFT
When turning off the connected Alarm, a tone should be
played on the Alarm and Qr HUBB for theft prevention.
ADJUSTMENT OF BITE ALARM
CONTROLS FROM Qr HUBB
This provides a detailed measurement of the paired alarms
battery level.
BATTERY LEVEL INDICATION
The Qr HUBB replicates the tone pitch of the linked/paired
Alarm.
TONE SETTING
The Qr HUBB will report the signal strength of the connected
alarm and also indicate that the LED is working.
RADIO SIGNAL STRENGTH
Qr Hubb can link other devices to also activate the bivvy
light when the device is active.
BIVVY LIGHT LINK
IQ PORT ON/OFF
LED ILLUMINATION COLOURS
Replicates colour of LED’s.

11
WOLF INTERNATIONAL
Suite 1, 284 Warley Hill, Great Warley,
Brentwood, Essex CM13 3AB
T: +44 (0) 333 366 8888
www.wolfint.com
For language translations of all instructions and
functions and care of your Wolf international
ICON Alarm or HUBB visit
www.wolfint.com/product-manuals/
Information of troubleshooting is available at
www.wolfint.com
Warranty
If you need information to the warranty please visit
www.wolfint.com/product-warranty/
Please ensure to register your new Wolf product at
www.wolfint.com/product-registration/
Customer Support
If you need support you can contact us by:
Telephone: +44 (0) 333 366 8888
More information can be found at
www.wolfint.com/customer-support/
Languages available:
English / Italian / French / Dutch / German
E&OE
Product Code: WFIC004
Patents Pending:
GB 1721169.9 IGB 1721166.5 IGB 1721158.2
EP 18213109.4 IEP 18213012.0 IEP 18213022.9
Compliant to:
Safety EN 62368-1 IRED 2014/53/EU IRoHS
www.wolnt.com
Table of contents
Other Wolf Security System manuals
Popular Security System manuals by other brands

System Sensor
System Sensor APA451 Installation and maintenance instructions

Equity
Equity NIGHTVISION 30330 manual

E2S
E2S GNExCP6B-PT instruction manual

Baldwin Boxall
Baldwin Boxall VIGIL ECLIPSE Installation and operating instructions

urmet domus
urmet domus 1068 Installation and programming manual

Cisco