Woodward easYgen-3100XT-P1 User manual

Product Specification
37594B
Remote Panel RP-3000XT for
easYgen-3000XT Series
Genset Controls
Plug-and-Play remote
annunciation and
remote control of the
easYgen-3000XT Series
genset controls
Generic remote panel,
connects to all easYgen-
3000XT series controls
Multi-Cast function,
offers connection to a
fleet of easYgen-3000XT
controls (one at a time)
Offers on-the-fly
configuration with same
security levels as
easYgen-3000XT
Simplifies wiring to
the access door and
keeps high voltage
connections remote
Small footprint makes
compact installations
Touch screen and Color
display
Ethernet communication
to genset control
Multi-lingual Capability
Personalization by
end user
CE Marked
UL/cUL Listing
DESCRIPTION
Woodward’s RP-3000XT is a touch screen remote control
and annunciation panel for use with the easYgen-3000XT
series controls. It is particularly useful with the back panel
mounted easYgen-3100XT/3400XT, providing control from
the front panel with greatly reduced wiring to the access
door, while keeping high voltage connections located safely
on the back panel.
The RP-3000XT offers all the HMI resources that the
display variants easYgen-3200XT/3500XT offer with a
touch screen technology. Irrespective of the easYgen-
3000XT variants, this compact HMI solution connects to up
to 32 XT controls (select and access one easYgen-3000XT
at a time).
The RP-3000XT offers switchgear builders, genset
packagers, and system integrators an off-the-shelf HMI option for any application where a secure remote control,
monitoring and visualization is desired, such as hospitals, data centers, offshore rigs, landfill and wastewater
gas-to-power applications to name a few.
In a paralleling application, the RP-3000XT provides the flexibility to connect each of the easYgen-3000XT
controls (one RP-3000XT for one easYgen-3000XT) or to connect multiple of the easYgen-3000XT (one RP-
3000XT for a fleet of easYgen-3000XTs, accessing one at a time). The communication between the two devices
is always through Ethernet.
Features
RP-3000XT features help realize following use cases:
Mounted to the front door and connected with a back panel mounted easYgen-3100XT or easYgen-
3400XT for a safe and compact installation
Installed away from genset room and connected with a front panel mounted easYgen-3200XT or
easYgen-3500XT for applications requiring multiple HMIs
Mounted to the front door and connected to a fleet of easYgen-3000XT series controls (up to 32) for
cost sensitive and/or space constrained applications
Power ON LED at face plate
Multi-lingual display capability of
the connected easYgen-XT (RP-
3000XT menu in English)

SPECIFICATIONS
Power supply 24 Vdc ±10%
Intrinsic consumption.............................................................. typical 7 W
Ambient temperature (operation)....................-20 to 60 °C (-4 to 140 °F)
Ambient temperature (storage).....................-30 to 70 °C (-22 to 158 °F)
Ambient humidity ......................10 to 90% RH@40 °C, non-condensing
Housing Front panel mounting PC plus ABS
(with die-cast aluminum alloy front bezel)
Dimensions WxHxD 03.4 × 150 × 43.7 mm
Front cutout WxH 192 × 138.5 mm
Front ................................................................insulating surface
Weight ....................................................................... approx. 1 kg
Sealing Front ....................................... IP66 (with clamp fastening)
Connection (power supply)..........................screw/plug terminals 2.5 mm²
Interface (others not to be used) ................................................. Ethernet
System Hardware
CPU ............................................................ RISC processor with 32 bits
............................................................... 600 MHz (ARM® CortexTM-AB)
Backup Memory.................................................................FRAM 128 KB
Memory.............................................................. DDR2 256 MB on board
Storage ........................................................ 512 MB on board, SLC type
Power-On LED bar ........................................................................... blue
Software
Operating System........................................Microsoft® Windows CE 6.0
Woodward Application ................... Remote Panel RP-3000XT software
....Auto-start software to connect to an easYgen-3000XT
......................................... for remote control via Ethernet
Display
Type...............................................................................WVGA TFT LCD
Size.....................................................................................177.8 mm (7')
Max. Resolution........................................................................ 800 x 480
Max. Colors......................................................................................... 64k
Luminance (cd/m2).............................................................................500
Viewing Angle (H/V) ....................................................................140/120
Backlight Life .....................................................................LED; 50,000 h
Brightness adjustable ....................................................................... yes
Contrast Ratio..................................................................................700:1
Touch Screen
Life span ......................................................................36 million touches
............................. at 8 mm diameter finger point through silicone rubber
............................................bearing at least 250 g two times per second
Light.................................................................Transmission Above 80%
Resolution................................................................................... Linearity
Beep ...................................................................... ON/OFF by software
Type.....................................................................5-wire, analog resistive
Vibration protection ...... Operating, random vibration 1 Grms (5 to 500 Hz)
Disturbance test (CE)............tested according to applicable EN guidelines
Listings ........... Industrial Control Equipment UL 508 certification
..................................CE, BSML, CCC, UL, FCC Class A
DIMENSIONS
Plastic housing with metal frame for front panel mounting
Dimensions in mm
Panel cut out:
192 x 138.5
TERMINAL DIAGRAM
1 Power supply
2 Ethernet Interface
Other interfaces not used for this application!
Power supply terminal (1):
Low voltage / Limited Energy power source

REMOTE CONTROL AND CONNECTION
The RP-3000XT IP address must be configured to be in the same Ethernet network as the easYgen-XTs.
After boot-up sequence the panel lands on MULTICAST screen. This screen presents all the easYgen-XT in the cur-
rent network by an icon and its device name (IP address). The device name/IP address is shown below the respec-
tive easYgen-XT icon (Figure 1-5). Touch twice the easYgen-XT you wish to connect to: the HOME screen of the
selected easYgen-XT appears (Figure 3).
A settings screen is provided for customizing the behavior according to your use cases see figure 2. The RP-XT
Ethernet network settings can be adjusted from this screen as well.
The MULTICAST screen presents all the easYgen-XT
controls in the same network.
Figure 1: MULTICAST screen with
1) Lock touch screen for cleaning
2) Refresh network overview
3) Open SETTINGS screen
4) Go to next page
(in real: only visible if “page is full”)
5) Icon and IP address/device name of the easY-
gen-XT controls (green: last connected)
The SETTINGS screen allows customization.
Figure 2: SETTINGS screen with
1) Three auto-connect options after power-up:
first in the multicast list/ last successful con-
nection / no auto-connect (nothing checked)
2) Delay time before auto-connecting (1 .. 120 s)
3) Brightness adjustment between 0 and 10
4) CLIENT Ethernet network settings
5) Back to MULTICAST screen
6) Activate Beep by touching screen
… and the HOME screen mirrors the
easYgen-XT HMI and front panel buttons:
Figure 3: HOME screen with
1) Simulated easYgen-XT front panel buttons
2) Mirrored easYgen-XT HMI screen with active soft buttons
3) IP address/device name of the connected easYgen-XT and back button to the MULTICAST screen

CONTACT
North & Central America
Tel.: +1 970 962 7331
SalesPGD_NAandCA@woodward.com
South America
Tel.: +55 19 3708 4800
SalesPGD_SA@woodward.com
Europe
Tel. Stuttgart: +
49 711 78954 510
Tel. Kempen: +
49 2152 145 331
SalesPGD_EUROPE@woodward.com
Middle East & Africa
Tel.: +971 2 6275185
SalesPGD_MEA@woodward.com
Russia
Tel.: +7 812 319 3007
SalesPGD_RUSSIA@woodward.com
China
Tel.: +86 512 8818 5515
India
Tel.: +91 124 4399 500
ASEAN & Oceania
Tel.: +49 711 78954 510
SalesPGD_ASEAN@woodward.com
www.woodward.com
Subject to alterations, errors excepted.
Subject to technical modifications.
This document is distributed for informa-
tional purposes only. It is not to be con-
strued as creating or becoming part of
any Woodward Company contractual or
warranty obligation unless expressly
stated in a written sales contract.
We appreciate your comments about the
content of our publications. Please send
comments including the document num-
ber below to
© Woodward
All Rights Reserved
37594B - 2017/03/Stuttgart
FEATURES OVERVIEW
Model
RP-3000XT
HMI
Analog Resistive Touch Screen
Yes
Color display
Power ON LED bar
Personalization (Boot-up Screen & Logo)
See application note #37637
I/Os
Ethernet
1
Remote Terminal Control
Based on VNC
Listings/Approvals
UL / cUL Listing
FCC
Class A
CE Marked
Hardware
P/N:
Plastic housing with Die-cast aluminum alloy front bezel and display (front panel mounting)
8446-1061
Mounting KIT (clamp set for panel mount)
8923-2292
Related Products
Genset control easYgen-3100XT/3200XT-P1 Product Specification (# 37582)
Genset control easYgen-3400XT/3500XT-P1/P2 Product Specification (# 37583)
Product Documentation
Remote panel RP-3000XT Technical Manual (# 37593)
Genset control easYgen-3100XT/3200XT-P1 Technical Manual (# 37574)
Genset control easYgen-3400XT/3500XT-P1 Technical Manual (# 37580)
Genset control easYgen-3400XT/3500XT-P2 Technical Manual (# 37581)
For more information contact:
This manual suits for next models