Worx WX030.91 Installation manual

20V Vacuum Cleaner WX030.91
SAFETY AND OPERATING MANUAL

2
20V Vacuum Cleaner WX030.91
PRODUCT SAFETY
GENERAL SAFETY
WARNINGS
WARNING: Read all safety warnings
and all instructions. Failure to follow the
warnings and instructions may result in electric
shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
-This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
- Children should be supervised to ensure that they
do not play with the appliance.
SAFETY WARNINGS FOR
BATTERY PACK
a) Do not dismantle, open or shred cells or
battery pack.
b) Do not short-circuit a battery pack. Do not
store battery packs haphazardly in a box or
drawer where they may short-circuit each
other or be short-circuited by conductive
materials. When battery pack is not in use,
keep it away from other metal objects, like paper
clips, coins, keys, nails, screws or other small
metal objects, that can make a connection from
one terminal to another. Shorting the battery
terminals together may cause burns or a fire.
c) Do not expose battery pack to heat or fire.
Avoid storage in direct sunlight.
d) Do not subject battery pack to mechanical
shock.
e) In the event of battery leaking, do not
allow the liquid to come into contact
with the skin or eyes. If contact has been
made, wash the affected area with copious
amounts of water and seek medical advice.
f) Seek medical advice immediately if a cell or
battery pack has been swallowed.
g) Keep battery pack clean and dry.
h) Wipe the battery pack terminals with a
clean dry cloth if they become dirty.
i) Battery pack needs to be charged before
use. Always refer to this instruction and use
the correct charging procedure.
j) Do not maintain battery pack on charge
when not in use.
k) After extended periods of storage, it may
be necessary to charge and discharge
the battery pack several times to obtain
maximum performance.
l) Battery pack gives its best performance
when it is operated at normal room
temperature (20 °C ± 5 °C).
m) When disposing of battery packs, keep
battery packs of different electrochemical
systems separate from each other.
n) Recharge only with the charger specified
by Worx.Do not use any charger other than
that specifically provided for use with the
equipment. A charger that is suitable for one
type of battery pack may create a risk of fire when
used with another battery pack.
o) Do not use any battery pack which is not
designed for use with the equipment.
p) Keep battery pack out of the reach of
children.
q) Retain the original product literature for
future reference.
r) Remove the battery from the equipment
when not in use.
s) Dispose of properly.
t) Do not mix cells of different manufacture,
capacity, size or type within a device.
u) Do not remove battery pack from its original
packaging until required for use.
v) Observe the plus (+) and minus (–) marks on
the battery and ensure correct use.
SYMBOLS
Warning
Read operator’s manual
RCM marking
ABN: Australian Business Number. By this
number, business information such as entity
type, status, business location etc. can be
found at website http://abr.business.gov.au.
ABN of Positec Australia Pty Limited is 14
101 682 357
Li-Ion battery. This product has been
marked with a symbol relating to ‘separate
collection’ for all battery packs and
battery pack. It will then be recycled or
dismantled in order to reduce the impact
on the environment. Battery packs can be
hazardous for the environment and for
human health since they contain hazardous
substances
Do not burn
Batteries may enter water cycle if disposed
improperly, which can be hazardous
for ecosystem. Do not dispose of waste
batteries as unsorted municipal waste.
Li-Ion
Li-Ion

3
20V Vacuum Cleaner WX030.91
3
4
8
9
1
2
5
7
6

4
20V Vacuum Cleaner WX030.91
C2
C1
B
A1 A2
D2
D1

5
20V Vacuum Cleaner WX030.91
C2
C1
B
A1 A2
D2
D1

6
20V Vacuum Cleaner WX030.91
COMPONENT LIST
1. VACUUM TUBE
2. ON-OFF SWITCH
3. BRUSH STORAGE PORT
4. DEBRIS EMPTYING BUTTON
5. CREVICE TOOL STORAGE PORT
6. BATTERY PACK*
7. DEBRIS CONTAINER COVER
8. CREVICE TOOL ACCESSORY
9. BRUSH ACCESSORY
*Some of the accessories mentioned in
illustrations or texts are not included in the
scope of supply.
TECHNICAL DATA
WX030.91
Rated voltage
20V
Maximum idle speed 34000/min
Machine weight
1.4kg
ACCESSORIES
WX030.91
Brush accessory 1
Crevice tool accessory 1
We recommend that you purchase your accessories
listed in the above list from the same store that sold
you the tool. Refer to the accessory packaging for
further details. Store personnel can assist you and
offer advice.
OPERATION INSTRUCTION
Note: Please read the instructions carefully
before use.
INSTALLATION AND OPERATION
1. Installation of the Brush/CreviceTool
Remove accessory from the storage port, connect to
the vacuum tube by pushing into place (See figure
A1)
NOTE: Crevice tool accessory can be stretched
out for usage (See figure A2)
2. Start/Stop (See figure B)
Press the on-off switch button to start the vacuum
cleaner operation, and press again to stop it.
WARNING: Please keep the air intake
unobstructed, otherwise it may cause motor
overheating and may damage the machine.
3. Debris Emptying Cleaning( See figure
C1,C2)
Press the debris emptying button to open the dust
cup. Rotate the filter counter-clockwise to remove
and rinse in clean water when needed.To reinsert
the filter, rotate clockwise and lock filter element in
place.
WARNING: Do not use the vacuum without
installing the filter element. If the suction becomes
decreased, it is necessary to clean out the debris in
the debris collection container
4. Filter Cleaning
The filter is composed of the filter net cylinder and
the HEPA filter. Remove both and discard debris
(see figure D1). Both filters can be rinsed in clean
water and air dried. Replace HEPA filter inside Net
cylinder filter, rotate clockwise until locked. Locate
three long slots on HEPA filter and match those in
the debris collection container. Rotate clockwise to
secure connection prior to using. ( See figure D2)
Note: In order to maintain excellent suction, it is
recommended to change HEPA every three months.
MAINTENANCE
WARNING: Remove the battery before carrying out
any servicing or maintenance.
Never use water or chemical cleaners to clean your
vacuum cleaner. Wipe clean with a dry cloth. Always
store your vacuum cleaner in a dry place. Keep
the motor ventilation slots clean. Keep all working
controls free of dust. If you see some sparks
flashing in the ventilation slots, this is normal and
will not damage your vacuum cleaner.
Operation instructions for the accessories
The brush is suitable for dust removal from
inaccessible corners in the interior of the car, such
as the bottom of the seat, the side of the seat, the

7
20V Vacuum Cleaner WX030.91
inside of the door, the area around the driver’s seat,
the rear window, the trunk of the car, etc.
The crevice tool can be used to clean most of the
cracks and corners of the car.
Precautions when using the machine
Cannot be used to absorb water.
Cannot be washed in water.
Check the hoses regularly and stop using if there is
any damage.
When cleaning or maintaining, remove the battery
pack.
STORAGE
Clean the moulded plastic housing of the machine
using a soft brush and clean cloth. Do not use water,
solvents or polishes. Remove all debris, especially
from the motor cooling vents.
Store in a secure, dry place out of the reach of
children.
Do not place other objects on the product.
ENVIRONMENTAL
PROTECTION
Disposal
The machine, its accessories and
packaging materials should be sorted for
environmentally friendly recycling.The
plastic components are labeled for categorized
recycling.
TROUBLESHOOTING
Issue Causes Solutions
Motor does not operate The battery has run out. Remove the battery pack and insert
charger for charging.
Decreased suction
Dust cup is full of dust. Clean the dust in the dust cup.
The filter element of the
dust cup is full of dust. Clean or replace filter element of dust cup
Battery low Remove the battery pack and insert
charger for charging.
Hose blocked Straightening hose after power-on can
inhale some foreign body.
Machine heating Machine run Slight heating-up is normal.
The battery is fully charged and
the dust in the dust cup does
not rotate.
The airway is blocked by
foreign bodies.
Clean up foreign bodies in the airway in
time.
Positec Australia Pty Limited
10 Corporate Blvd Bayswater , VIC 3153,Australia

Copyright © 2020, Positec. All Rights Reserved.
AR01554300
www.worx.com
Table of contents
Other Worx Vacuum Cleaner manuals