WT sensor PCM260 User manual

1 www.wtsensor.com
PCM260(WTL01) Submersible Level Transmitter
Features
■Piezoresistive diffused silicon
pressure sensor
■Probe insertion measurement
method, easy to install
■For level measurement
■Multiple protective structure
design, high protection ability
■LCD option
■Variety of styles, suitable for
various industrial applications
■Anti-corrosion stainless steel
material adopted, suitable for
many occasions
Applications
■Static pressure level
■Liquid tanks
■Sewage
■Industrial water
■Pools
■Wells
■Rivers
■Seawater
■Lakes
Notes:
1 Do not touch the diaphragm with
hard objects, which may cause
damage to the diaphragm.
2 Please read the Instruction Manual of
the product carefully before installation
and check the relevant information of
the product.
3 Strictly follow the wiring method for
wiring, otherwise it may cause product
damage or other potential faults.
4 Misuse of the product may cause
danger or personal injury.
Product overview
PCM260(WTL01) Submersible Level Transmitter accurately
measures static pressure of the liquid proportional to the level
depth using high performance piezoresistive diffused silicon
pressure sensor as the measuring element. The result is
converted to standard current or voltage signal output through
signal conditioning circuit, establishing the linear corresponding
relation between the output signal and liquid depth to complete the
measurement of the liquid depth. The product has advantages of
high precision and small volume. Submerse it directly into liquid,
the height between the end of the transmitter to the liquid surface
is measured easily. The product is applicable to the measurement
and control of the liquid level in the petroleum, chemical industry,
power plant, urban water supply and hydrological exploration
fields.
PCM260 has passed long-term aging and stability screening with
stable and reliable performance and can be used in harsh outdoor
environment. Meanwhile, it can display liquid level on site. Zero
shift and full scale span shift available.
Notes:
1 Do not misuse documentation.
2 The information presented in this product sheet is for reference only. Do
not use this document as a product installation guide.
3 Complete installation, operation, and maintenance information is provided
in the instructions of the product.
4 Misuse of the product may cause danger or personal injury.

2 www.wtsensor.com
Performance parameters
Pressure range
0~0.5m…20mH₂O
Supply & output
4~20mA (18~36V, 24V typical)
4~20mA with display (12~36V, 24V typical)
1~5V, 0~5V, 0.5~4.5V, 0~10V (12~32V, 24V typical)
Operating temp.
-20℃~85℃
Medium temp.
-10℃~70℃
Storage temp.
-40℃~125℃
Compensated temp.
0m~10mH₂O: 0℃~60℃
10m~200mH₂O: -10℃~70℃
Zero temp. coefficient
±1.5%FS (within compensated temp.)
Span temp. coefficient
±1.5%FS (within compensated temp.)
Overpressure
200%FS~300%FS
Mechanical vibration
20g (20~5000HZ)
Shock
100g (11ms)
Accuracy
0.5%FS
Insulation
100MΩ/250VDC
Response time
≤1ms (Up to 90%FS)
Long term stability
±0.2%FS/year
Protection
IP68
Material
Low copper aluminum alloy for junction box; stainless steel for level probe
Polyurethane wire for cable
Medium compatibility
All kinds of media compatible with stainless steel 304
Electrical connection
Code
J1: 2088 housing
J2: 2088 housing with
display
J3: Cable outlet
Dimension
In mm
Junction box
Waterproof wire
Level probe
With display
Waterproof wire
Level probe
Cable outlet
Waterproof wire
Level probe

3 www.wtsensor.com
Wiring method
Wiring
method
Current output Voltage output
①Red wire: Supply+
Green wire:
Current output
②Red wire: Supply+
Yellow wire:
Voltage output
Green wire:
Ground
Installation instructions (for reference only)
1. Installation in still water (deep wells, pools, liquid tanks, etc.)
Installation tips:
1) When measuring the level of stationary fluid in an open container, place the level transmitter
vertically into the bottom of the container and secure the cable connecting the transmitter to the
junction box at the opening of the container.
2) When the medium viscosity is relatively large (such as sewage pool), casing or bracket can be
installed to ensure that the transmitter can be put into the bottom of the container.
3) When doing an open-air installation, the terminal box of the transmitter should be placed in a
ventilated and dry place to avoid direct exposure to light and rain, which may cause the shell
temperature to be too high or water to get inside and damage the internal circuit board.
Sewage
2 non-polar wires
Control
room
Secondary
instrument
Ventilated
Secondary instrument
or control system

4 www.wtsensor.com
Installation instructions (for reference only) (cont.)
2. Installation in moving water (rivers, lakes, etc.)
Installation tips:
1) When measuring the water level in flowing water, when the medium fluctuates greatly, a steel pipe
can be inserted in the water channel with an inner diameter of about 50 cm. Make several holes of
about Φ5 in diameter on the side of the immersed pipe opposite to the flow direction to allow water to
enter the pipe and fix the cable and junction box at the outlet of the pipe.
2) When the medium of the water channel fluctuates greatly or the sediment is large, a damping device
can be installed to filter the sediment, eliminate the adverse effects of dynamic pressure and wave
and ensure the measurement accuracy.
3) When installing the product in lightening intensified area, please indicate “Lightning Protection” when
placing an order. Meanwhile, it is recommended that users install lightning protection devices at the
site and ensure that the product and power supply are reliably grounded to reduce damage to the
transmitter caused by lightning.
Pressure range selection
Pressure
range code
Pressure
reference
Pressure range
Overpressure
Burst
pressure
Remark
0.5mi
G
0.5m H2O
300%FS
600%FS
1mi
G
1m H2O
300%FS
600%FS
1.5mi
G
1.5m H2O
300%FS
600%FS
2mi
G
2m H2O
300%FS
600%FS
2.5mi
G
2.5m H2O
300%FS
600%FS
3mi
G
3m H2O
300%FS
600%FS
3.5mi
G
3.5m H2O
300%FS
600%FS
4mi
G
4m H2O
300%FS
600%FS
4.5mi
G
4.5m H2O
300%FS
600%FS
5mi
G
5m H2O
300%FS
600%FS
5.5mi
G
5.5m H2O
300%FS
600%FS
6mi
G
6m H2O
300%FS
600%FS
6.5mi
G
6.5m H2O
300%FS
600%FS
Control room
Control room
Steel pipe
Damping device
Flow direction

5 www.wtsensor.com
Pressure range selection (cont.)
Pressure
range code
Pressure
reference
Pressure range
Overpressure
Burst
pressure
Remark
7mi
G
7m H2O
300%FS
600%FS
8mi
G
8m H2O
300%FS
600%FS
9mi
G
9m H2O
300%FS
600%FS
10mi
G
10m H2O
200%FS
500%FS
12mi
G
12m H2O
200%FS
500%FS
15mi
G
15m H2O
200%FS
500%FS
18mi
G
18m H2O
200%FS
500%FS
20mi
G
20m H2O
200%FS
500%FS
Cable length selection
Pressure
range code
Mapping relation
Code
Definition
0.5mi
L1.5 L2 L3 L5 L6 L8 L10 L12 L15 L18 L20 L25
L1.5
Cable length 1.5m
1mi
L1.5 L2 L3 L5 L6 L8 L10 L12 L15 L18 L20 L25
L2
Cable length 2m
1.5mi
L2 L3 L5 L6 L8 L10 L12 L15 L18 L20 L25
L3
Cable length 3m
2mi
L3 L5 L6 L8 L10 L12 L15 L18 L20 L25
L5
Cable length 5m
2.5mi
L3 L5 L6 L8 L10 L12 L15 L18 L20 L25
L6
Cable length 6m
3mi
L5 L6 L8 L10 L12 L15 L18 L20 L25
L8
Cable length 8m
3.5mi
L5 L6 L8 L10 L12 L15 L18 L20 L25
L10
Cable length 10m
4mi
L5 L6 L8 L10 L12 L15 L18 L20 L25
L12
Cable length 12m
4.5mi
L5 L6 L8 L10 L12 L15 L18 L20 L25
L15
Cable length 15m
5mi
L5 L6 L8 L10 L12 L15 L18 L20 L25
L18
Cable length 18m
5.5mi
L6 L8 L10 L12 L15 L18 L20 L25
L20
Cable length 20m
6mi
L8 L10 L12 L15 L18 L20 L25
L25
Cable length 25m
6.5mi
L8 L10 L12 L15 L18 L20 L25
For exceeding length, order as
accessory.
7mi
L8 L10 L12 L15 L18 L20 L25
8mi
L10 L12 L15 L18 L20 L25
9mi
L10 L12 L15 L18 L20 L25
10mi
L10 L12 L15 L18 L20 L25
12mi
L15 L18 L20 L25
15mi
L15 L18 L20 L25
18mi
L20 L25
20mi
L25

6 www.wtsensor.com
V1.0
How to order
PCM260 - 1.5mi B1 J3 L1.5
Example: PCM260-1.5miB1J3L1.5
Refer to product model PCM260, with pressure range 1.5m H2O, output signal 4~20mA (24VDC
supply), electrical connection cable outlet, cable length 1.5m.
Optional accessories
1. The part of cable exceeding the standard cable length
2. PCM260 anti-blocking protective cover (with filter)
Contact us
Nanjing Wotian Technology Co.,Ltd.
Add: 5 Wenying Road, Binjiang Development Zone, Nanjing, 211161, China
Sales Manager: Wuzhou Lian
MP: 0086-13998828452
Email: lianwuzhou@wtsensorus.com
Product model
Refer to “Pressure
range selection”
B1: 4~20mA (24VDC)
B2: 1~5V (24VDC)
B3: 0~5V (24VDC)
B6: 0.5~4.5V (24VDC)
B7: 0~10V (24VDC)
Refer to “Cable
length selection”
J1: 2088 housing
J2: 2088 housing
with display
J3: Cable outlet
This manual suits for next models
1
Table of contents
Other WT sensor Transmitter manuals

WT sensor
WT sensor PCM3051S User manual

WT sensor
WT sensor PCM3601 User manual

WT sensor
WT sensor PCT220 User manual

WT sensor
WT sensor PCT400 User manual

WT sensor
WT sensor PCM260H User manual

WT sensor
WT sensor PCM400 User manual

WT sensor
WT sensor PCT381 User manual

WT sensor
WT sensor PCMPT01 Series User manual

WT sensor
WT sensor PCT400 User manual

WT sensor
WT sensor PCM610 User manual