manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. WURM
  6. •
  7. Controllers
  8. •
  9. WURM CRC-BL User manual

WURM CRC-BL User manual

Other WURM Controllers manuals

WURM CRC-BL-EEV User manual

WURM

WURM CRC-BL-EEV User manual

WURM FKL003 User manual

WURM

WURM FKL003 User manual

WURM CRC-BL User manual

WURM

WURM CRC-BL User manual

WURM DCC-XP V6 User manual

WURM

WURM DCC-XP V6 User manual

WURM CRC-BL-EEV User manual

WURM

WURM CRC-BL-EEV User manual

WURM FRIGOLINK ANI-1F6-A User manual

WURM

WURM FRIGOLINK ANI-1F6-A User manual

WURM CRC-BL-EEV User manual

WURM

WURM CRC-BL-EEV User manual

WURM CRC-XP User manual

WURM

WURM CRC-XP User manual

WURM CRD-XP User manual

WURM

WURM CRD-XP User manual

WURM CRU-XP User manual

WURM

WURM CRU-XP User manual

WURM AHC-XP User manual

WURM

WURM AHC-XP User manual

WURM CRC-BL User manual

WURM

WURM CRC-BL User manual

WURM HCO2-G4 User manual

WURM

WURM HCO2-G4 User manual

WURM CRDP-XP User manual

WURM

WURM CRDP-XP User manual

WURM DCC-BL User manual

WURM

WURM DCC-BL User manual

WURM FKV003 User manual

WURM

WURM FKV003 User manual

WURM TRH-XP User manual

WURM

WURM TRH-XP User manual

WURM SVD001 User manual

WURM

WURM SVD001 User manual

WURM CRD-XP User manual

WURM

WURM CRD-XP User manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Cold location controller for top-hat rail installation with enhanced operating modes for 4 cold locations
CRC-BL_V2.1.0_PI_2019-11_EN 1
Subject to technical changes
CRC-BL
1 CRC-BL
Cold location controller for top-hat rail installation with enhanced operating modes
for 4 cold locations
1.1 Front view
Fig. 1: Front view
1.2 Features
• Suitable for max. 4 cold locations
• Basic functional sequences and parameters preprogrammed through selection of cold location
type
• Intelligent fan control, compressor oscillation protection, fan delay
• Thermal fan control and draining time after defrosting
• Suitable for electric defrost, forced air defrost, hot gas defrost and cool gas defrost
• Defrost control by real-time clock with power reserve
• Simple defrost synchronisation of multiple controllers (master-slave)
• 6 defrost times via integrated weekly timer
• Digital inputs for setpoint switchover, manual defrost initiation and door contact
• Option to select 3-point control
• Weighting of the control sensor for day operation and night operation can be set separately
• Support for higher baud rates on the C-BUS
• Possible blocking to prevent parameter adjustment
• Plain text designation for each parameter on the display, language selectable
• Unique parameter identification with Quicklinks
• One-finger operation
• Plug-in screw terminals
• Large data memory for temperature list
• Connection to the Wurm system through a Wurm CAN communication bus (C-BUS) and
FRIGODATA XP
Cold location controller for top-hat rail installation with enhanced operating modes for 4 cold locations
2 CRC-BL_V2.1.0_PI_2019-11_EN
Subject to technical changes
CRC-BL
1.3 Safety instructions
Writing conventions
WARNING • Avoid the described hazard: otherwise, electric voltage poses a hazard that could lead to death
or serious bodily injury.
CAUTION • Avoid the described hazard: otherwise, minor or medium physical injury or damage to property
will result.
For your safety
For safe operation and to avoid personal injury and equipment damage through operator error, always
read these instructions, become familiar with the device, and follow all safety instructions on the prod-
uct and in this document, as well as the safety guidelines of Wurm GmbH & Co. KG Elektronische
Systeme. Keep these instructions ready to hand for quick reference and pass them on with the device
if the product is sold.
Wurm GmbH & Co. KG Elektronische Systeme accepts no liability in the event of improper use or use
for other than the intended purpose.
WARNING DANGER TO LIFE FROM ELECTRIC SHOCK AND/OR FIRE!
• Switch off the power to the entire plant when installing, wiring or removing. Otherwise, mains
voltage and/or external voltage may still be present, even if the control voltage is switched off.
Always remove both power plugs (L and N).
• The device should only be wired by a qualified electrician.
• Always use the correct tools for all work.
• Check all wiring after connection.
• Take note of the maximum loads on all connections.
• Never expose the device to moisture, for example, condensation or cleaning agents.
• Take the device out of operation if it is faulty or damaged and is therefore compromising safe
operation.
• Do not open the device.
• Do not repair the device yourself. If required, send it in for repair with an exact description of the
fault.
CAUTION ELECTROMAGNETIC INTERFERENCE CAN CAUSE FAULTS!
• Always use shielded data cables and place them far away from power lines.
Target group This manual is intended for "service technicians".
Intended use The CRC-BL is a cold location controller for max. 4 cold locations.
Wurm Infocenter paperless info
Cold location controller for top-hat rail installation with enhanced operating modes for 4 cold locations
CRC-BL_V2.1.0_PI_2019-11_EN 3
Subject to technical changes
CRC-BL
Software revision and validity of documentation
Any software versions not listed are special solutions for individual projects and are not described in detail in this
document. This document automatically ceases to be valid if a new technical description is issued.
Manufacturer: Wurm GmbH & Co. KG Elektronische Systeme, Morsbachtalstraße 30, D-42857 Remscheid
You can find more information on our website at www.wurm.de.
1.4 Connection diagram
Fig. 2: Connection diagram
Software version
V2.1.0 – 2019-11 Documentation status
Item Designation Function
1C-BUS interface Data communication (H = CAN high, S = shield,
L = CAN low)
2Output relays K1...K4 Dependent on cold location type, potential-free contact,
230V~, 4(2)A
3Power supply for L 230V~/50Hz
4Power supply for N Neutral conductor
5Digital inputs Di1...Di4 Dependent on cold location type
6Defrost bus Defrost synchronisation
7Sensor inputs S1...S4 Temperature sensor
12 13 14 15 16 17 18
11 22 23 24 25 26 27 28 29
21
38 37 36 35 34 33 32 3139
4321
12 13 14 15 16 17 18
11 22 23 24 25 26 27 28 29
21
38 37 36 35 34 33 32 3139
CRC-BL
Frigoentry Blueline
2sec. d
c
12
4
6
3
5
7
S2
S3
S4
S1
GND
Di2
Sync.
Di3
N
Di1
Di4
L
K1
K2
K3
K4
H
0V
S
L
Cold location controller for top-hat rail installation with enhanced operating modes for 4 cold locations
4 CRC-BL_V2.1.0_PI_2019-11_EN
Subject to technical changes
CRC-BL
1.5 Installing the device
This device is designed for top-hat rail installation. The housing has standard dimensions according
to DIN 43880 and is also suitable for operation in fuse boxes and distribution cabinets.
The device can be positioned immediately next to another without gaps.
WARNING DANGER TO LIFE FROM ELECTRIC SHOCK AND/OR FIRE!
• Switch off the power to the entire plant before installing. Otherwise, mains voltage and/or exter-
nal voltage may still be present, even if the control voltage is switched off. Always remove both
power plugs (L and N).
The entire system must be free of voltage.
1. (A) Place the device with the leading edge at an acute angle to the top-hat rail.
2. (B) Push the device downwards onto the top-hat rail.
The device snaps into place with the fastening safety catch (a) on the top-hat rail.
You can now connect the device.
Fig. 3: Top-hat rail installation
1.6 Technical data
Power supply 230V~, +10% / -15%, max. 7VA
Display 1 x display with text display
2 x green LEDs, C-BUS data traffic (CAN Tx, CAN Rx)
C-BUS communication 3-wire CAN bus interface with integrated power supply, galvani-
cally isolated
Temperature sensors 4 x TRK277, DGF
(T2015, T3000, TF201/TF231, K243)
Digital inputs 4 x potential-free
Output relay 4 x relays 230V~, normally open contact, 230V~, 4(2)A
Real-time clock Battery-powered
Monitoring system Monitoring of data memory and connected sensors
Dimensions (W x H x D) 106mm x 90mm x 58mm (DIN 43880)
Fastening Top-hat rail TH 35-15 or TH 35-7.5 (DIN EN 60715)
Ambient temperature Operation: 0...+55°C, storage: -25...+70°C
Weight About 450g
CE conformity - 2014/30/EU (EMC Directive)
- 2014/35/EU (Low Voltage Directive)
EAC conformity - TR CU 004/2011
- TR CU 020/2011
RoHS II
Valid from Version 2.1.0
A