XtendLan XL-ICA-206M3 User manual

XL-ICA-206M3
IP camera (IPC)
User's manual

i
Welcome
Thank you for purchasing our IP camera!
This user’s manual is designed to be a reference tool for your system.
Please read the following safeguard and warnings carefully before you use this series product!
Please keep this user’s manual well for future reference!

ii
Important Safeguards and Warnings
1.Electrical safety
All installation and operation here should conform to your local electrical safety codes.
The power shall conform to the requirement in the SELV (Safety Extra Low Voltage) and the Limited
power source is rated 12V DC or 24V AC in the IEC60950-1.
We assume no liability or responsibility for all the fires or electrical shock caused by improper handling
or installation.
We are not liable for any problems caused by unauthorized modification or attempted repair.
2.Transportation security
Heavy stress, violent vibration or water splash are not allowed during transportation, storage and
installation.
3.Installation
Do not apply power to the camera before completing installation.
Please install the proper power cut-off device during the installation connection.
Always follow the instruction guide the manufacturer recommended.
4.Qualified engineers needed
All the examination and repair work should be done by the qualified service engineers.
We are not liable for any problems caused by unauthorized modifications or attempted repair.
5.Environment
This series IP camera should be installed in a cool, dry place away from direct sunlight, inflammable,
explosive substances and etc.
Please keep it away from the electromagnetic radiation object and environment.
Please make sure the CCD (CMOS) component is out of the radiation of the laser beam device.
Otherwise it may result in CCD (CMOS) optical component damage.
Please keep the sound ventilation.
Do not allow the water and other liquid falling into the camera.
Thunder-proof device is recommended to be adopted to better prevent thunder.
The grounding holes of the product are recommended to be grounded to further enhance the reliability
of the camera.
6. Daily Maintenance
Please shut down the device and then unplug the power cable before you begin daily maintenance
work.
Do not touch the CCD (CMOS) optic component. You can use the blower to clean the dust on the lens
surface.

iii
Always use the dry soft cloth to clean the device. If there is too much dust, please use the water to
dilute the mild detergent first and then use it to clean the device. Finally use the dry cloth to clean the
device.
Please put the dustproof cap to protect the CCD (CMOS) component when you do not use the camera.
7. Accessories
Be sure to use all the accessories recommended by manufacturer.
Before installation, please open the package and check all the components are included.
Contact your local retailer ASAP if something is broken in your package.
Accessory Name Amount
IPC Unit 1
MD9M data converter cable 1
Accessories bag 1
Quick Start Guide 1
CD 1

iv
Table of Contents
1General Introduction ..................................................................................................................1
1.1 Overview........................................................................................................................1
1.2 Features.........................................................................................................................1
1.3 Specifications................................................................................................................2
1.3.1 Performance...........................................................................................................2
1.3.2 Factory Default Setup...........................................................................................3
2Structure ....................................................................................................................................11
2.1 Multiple-function Combination Cable ......................................................................11
2.2 Framework and Dimension.......................................................................................12
2.3 Bidirectional talk .........................................................................................................13
2.3.1 Device Connection ..............................................................................................13
2.3.2 Operation ..............................................................................................................13
2.4 Alarm Setup.................................................................................................................13
3Installation .................................................................................................................................15
3.1 Device Installation ......................................................................................................15
3.2 SD Card Installation ...................................................................................................18
3.3 Lens Adjustment.........................................................................................................18
4Quick Configuration Tool.........................................................................................................20
4.1 Overview......................................................................................................................20
4.2 Operation .....................................................................................................................20
5Web Operation..........................................................................................................................23
5.1 Network Connection...................................................................................................23
5.2 Login and Main Interface...........................................................................................23

v
6FAQ ............................................................................................................................................26
Appendix Toxic or Hazardous Materials or Elements ...............................................................27

1
1General Introduction
1.1 Overview
This series IP camera integrates the traditional camera and network video technology. It adopts audio
and video data collection, transmission together. It can connect to the network directly without any
auxiliary device.
This series IPC uses standard H.264 video compression technology and G.711a audio compression
technology, which maximally guarantee the audio and video quality.
This series IPC enclosure has the strong resistance capacity, which can guarantee the proper work
performance under heavy strike. It supports real-time monitor and listening at the same time. It
supports analog video output and dual-way bidirectional talk.
It can be used alone or used in a network area. When it is used lonely, you can connect it to the
network and then use a network client-end. Due to its multiple functions and various uses, this series
IPC is widely used in many environments such office, bank, road monitor and etc.
1.2 Features
User
Management
zDifferent user rights for each group, one user belongs to one group.
zThe user right shall not exceed the group right.
Storage
Function
zSupport central server backup function in accordance with your configuration
and setup in alarm or schedule setting
zSupport record via Web and the recorded file are storage in the client-end
PC.
zSupport built-in SD card.
zSupport local SD card hot swap, support short-time storage when encounter
disconnection.
Alarm
Function
zReal-time respond to external local alarm input and video detect as user pre-
defined activation setup and exert corresponding message in screen and
audio prompt(allow user to pre-record audio file)
zReal-time video detect: motion detect, camera masking.
zCan generate an alarm when network abnormal, SD card abnormal event
occurred.
Network
Monitor
zIPC supports one-channel audio/video data transmit to network terminal and
then decode. Delay is within 270ms (network bandwidth support needed)
zMax supports 20 connections.
zAdopt the following audio and video transmission protocol: HTTP, TCP, UDP,
MULTICAST, RTP/RTCP, RTSP and etc.
zSupport web access, widely used in WAN.
Network
Management
zRealize IPC configuration and management via Ethernet.
zSupport device management via web or client-end.
zSupport various network protocols.
Peripheral
Equipment
zSupport the on-off alarm device to alarm via the sound or the light.
Power zExternal power adapter DC12V/AC 24V
zSupport PoE.
Assistant
Function
zLog function
zSupport PAL/NTSC

2
zSupport system resource information and running status real-time display.
zDay/Night mode auto switch (ICR switch).
zBuilt-in IR light. Support IR night vision (For HDBW Series only).
zBacklight compensation: screen auto split to realize backlight compensation
to adjust the bright.
zSupport electronic shutter and gain setup.
zSupport video watermark function to avoid vicious video modification.
1.3 Specifications
1.3.1 Performance
Please refer to the following sheet for IPC performance specification.
Model
Parameter IPC-HDB/HDBW3300 Series IPC-HDB/HDBW3110 Series
Main
Processor TI Davinci high performance DSP
OS Embedded LINUX
System
Resources Support real-time network, local record, and remote operation at the same
time.
User Interface Remote operation interface such as WEB, DSS, PSS
System
System Status SD card status, bit stream statistics, log, and software version.
Image Sensor 1/2.8-inch CMOS 1/3-inch CCD
Pixel 2048(H)*1536(V)1280(H)*960(V)
Day/Night
Mode Support day/night mode switch and IR-CUT at the same time.
Auto Iris DC drive
Gain Control Fixed/Auto
White Balance Manual/Auto
BLC Manual/Auto
Electronic
Shutter
Manual/Auto
PAL: It ranges from 1/3 to 1/10000.
NTSC: It ranges from 1/4 to 1/10000.
Manual/Auto
PAL: It ranges from 1/3 to
1/100000.
NTSC: It ranges from 1/4 to
1/100000.
Video
Compression
Standard H264/JPEG/MJPEG
Video Frame
Rate
PAL:
Main stream(2048*1536@15fps)
extra stream,(704*576@15fps)
Main stream(1920*1080@25fps)
extra stream(704*576@25fps)
NTSC:
Main stream(2048*1536@15fps)
extra stream(704×480@15fps)
Main stream(1920*1080@30fps)
extra stream(704×480@30fps)
PAL:
Main stream
(1280*[email protected])
extra stream,
(704*[email protected])
Main stream(1280*720@25fps)
extra stream(704*576@25fps)
NTSC:
Main stream(2048*1536@22fps)
extra stream(704×480@22fps)
Main stream(1920*1080@30fps)
extra stream(704×480@30fps)
Video Bit Rate H.264: 56Kbps-8192Kbps.
MJPEG is adjustable and bit rate is adjustable.
Support customized setup.
Video Parameter
Video Flip Support mirror.
Support flip function.

3
Snapshot Max 1f/s snapshot. File extension name is JPEG.
Privacy Mask Supports max 4 privacy mask zones
Video Setup Support parameter setup such as bright, contrast.
Video
Information Channel title, time title, motion detect, privacy mask.
Lens Interface CS. Lens is the default accessories
Audio Input 1-channel,RCA audio input.
Audio Output 1-channel, RCA, audio output.
Bidirectional
Talk Input Reuse the first audio input channel
Audio Bit Rate 16kbps 16bit
Audio
Audio
Compression
Standard G.711a/G.711u/PCM
Motion Detect
396 (18*22) detection zones;sensitivity level ranges from 1 to 6 (The 6th
level has the highest sensitivity)
Activation event, alarm device, audio/video storage, image snapshot, log,
email function and etc.
Video
Video Loss Activation event, alarm device, audio/video storage, image snapshot, log,
email function and etc.
Alarm Input 2-channel input,1-channel output
Record
Priority Manual>External alarm >Video detect>Schedule
Record
and
Backup
Local Storage Support Micro SD card storage
Wire Network 1-channel wire Ethernet port, 10/100 Base-T Ethernet
Network
Protocol
Standard HTTP, TCP/IP, IPv4/IPv6, ARP, IGMP, ICMP, RTSP, RTP, UDP,
SMTP, FTP, DHCP, DNS, DDNS, PPPOE, UPNP, NTP, Bonjour, SNMP,
NFS.
Network
Remote
Operation Monitor, system setup, file download, log information, maintenance ,
upgrade and etc
Video Output 1-channel analog video output,BNC port, 9-pin port connection
Reset 6-pin port connection
AUX
Interface
IR light 35 LED, IR distance 10 to 20 meters (For HDBW series product only)
Power Support AC24V/DC12V power. PoE
Power
Consumption General series: below 7W.
IR series: below 13W.
General series: below 14W.
IR series: below 16W.
Working
Temperature -10℃~+60℃
Working
Humidify 10%~90%
Dimensions(m
m) ¢160x118.5
Weight 1.25g
General Parameter
Installation Support various installation modes(Enclosure and bracket is optional)
1.3.2 Factory Default Setup
Please refer to the following sheet for factory default setup information.

4
Default setup
Function
Setup Type Item IPC-
HDB/HDBW330
0 Series
IPC-
HDB/HDBW31
10 Series
Brightness 50
Contrast 50
Hue 50
Saturation 50
Gain mode Auto
Gain limit 80
Exposure mode Auto
Auto iris Enable
Scene mode Auto
Day/night mode Auto
BLC Off
Conditions
Flip Disable
Bit stream
type General
Encode
mode H.264B
Resolution 1080P
(1920*1080)
720P(1280*72
0)
Frame rate
(FPS)
PAL: 25
NTSC:30
Bit stream
type CBR
Reference bit
rate 3584-8192 Kb/S
Bit rate 8192
I frame
interval 50
Watermark
settings Enable
Main
stream
Watermark
character DigitalCCTV
Enable Enable
Bit stream
type General
Encode
mode H.264B
Resolution CIF(352×288/35
2×240)
CIF(352×288/3
52×240)
Frame rate
(FPS)
PAL: 25
NTSC:30
Bit rate type CBR
Camera Setup
Video
Video bit
stream
Extra
stream
Reference bit
rate 192-1024Kb/S

5
Default setup
Function
Setup Type Item IPC-
HDB/HDBW330
0 Series
IPC-
HDB/HDBW31
10 Series
Bit rate 640
I frame
interval 50
Snap type General snap
Image size 1080P
(1920*1080)
720P(1280*7
20)
Quality Better
Snapshot
Interval 7s
Privacy mask Enable
Channel title Enable
Overlay
Time title Enable
Snapshot
path
C:\PictureDownload
Path
Record path C:\RecordDownload
Enable Enable
Main stream Encode
mode G.711A
Enable Disable
Audio
Sub(Extra) stream Encode
mode G.711A
Host name IPC
Ethernet card Wire(Default)
Mode Static
MAC
address Depends on the device
IP version IPV4
IP address 192.168.1.168
Subnet mask 255.255.255.0
Default
gateway 192.168.1.1
Preferred
DNS 8.8.8.8
Alternate
DNS 8.8.8.8
TCP/IP
Enable
ARP/Pingto
to set IP
address
service
Enable
Max
connection 10
Network setup
Connection
TCP port 37777

6
Default setup
Function
Setup Type Item IPC-
HDB/HDBW330
0 Series
IPC-
HDB/HDBW31
10 Series
UDP port 37778
HTTP port 80
RTSP port 554
Enable Disable
User name N/A
PPPoE
Password N/A
Server type Disable ,CN99 DDNS
Server IP none
Port 80
Domain
name none
User name none
Password N/A
DDNS
Update
period 5m
IP filter Trusted sites Disable
SMTP server none
Port 25
Anonymity Disable
User name anonymity
Password N/A
Sender none
Authenticatio
n (Encrypt
mode)
N/A
Title
(Subject) IPC Message
Main
Receiver N/A
Interval 0s
SMTP(email)
Health email Disable ,interval=60m
UPnP Enable UPnP Disable
SNMP v1 Disable
SNMP v2 Disable
SNMP port 161
Read
community public
Write
community private
Trap address N/A
SNMP
Trap port 162

7
Default setup
Function
Setup Type Item IPC-
HDB/HDBW330
0 Series
IPC-
HDB/HDBW31
10 Series
Enable Enable
Bonjour Server name “Device name+SN”.
Depends on the device.
Multicast
address 239.255.42.42
Multicast
Port 36666
Enable Disable
SN 1
Server IP 0.0.0.0
Port 7000
Auto register
Sub-device
ID none
WIFI On(Enable) Enable
Real-time
monitor 0
QoS
Command 0
Enable Disable
Anti-dither 5 seconds
Sensitivity 3
Record
Channel Enable
Record
Delay 10 seconds
Relay
(Alarm)
output
Enable
Alarm delay 10s
Send email Disable
PTZ Disable
Activation N/A
Address 0
Motion detect
Snapshot Disable
Enable Disable
Record
Channel Enable
Record
Delay 10 seconds
Relay out Enable
Record
Delay 10 seconds
Send email Disable
Event
management
Video detect
Video (Camera) masking
PTZ Disable

8
Default setup
Function
Setup Type Item IPC-
HDB/HDBW330
0 Series
IPC-
HDB/HDBW31
10 Series
Activation Disable
Address 0
Snapshot Disable
Enable Disable
Relay input Alarm1
Anti-dither 5s
Sensor type NO
Record
channel Enable
Record delay 10s
Relay
(Alarm)
output
Enable
Relay
(Alarm) delay 10s
Send email Disable
PTZ Disable
Activation N/A
Address 0
Relay (Alarm) activation
Snapshot Disable
Alarm setup
Relay (Alarm)
output 1
Enable Disable
Relay
(Alarm)
output
Enable
Relay output
delay 10s
No SD card
Send email Disable
Enable Disable
Capacity limit
(Space
threshold)
10%
Relay
(Alarm)
output
Enable
Relay output
delay 10s
Capacity warning
Send email Disable
Enable Disable
Abnormity
SD card
error
Relay
(Alarm)
output
Enable

9
Default setup
Function
Setup Type Item IPC-
HDB/HDBW330
0 Series
IPC-
HDB/HDBW31
10 Series
Relay output
delay 10s
Send email Disable
Enable Disable
Record Enable
Record delay 10s
Relay
(Alarm)
output
Enable
Disconnection
Relay output
delay 10s
Enable Disable
Record Enable
Record delay 10s
Relay
(Alarm)
output
Enable
IP conflict
Relay output
delay 10s
FTP enable Disable
Server IP N/A
Port 21
User name anonymity
Password N/A
Remote
storage path share
FT
P
Emergency
storage to
local path
Disable
NAS enable Disable
Mode NFS
Server IP N/A
Port 21
User name N/A
Password N/A
Destination(Storag
e )
Network storage
Remote
storage path N/A
Pack
duration 8m
Pre-record 5s
Storage
management
Conditions (Record
control)
Disk full Overwrite

10
Default setup
Function
Setup Type Item IPC-
HDB/HDBW330
0 Series
IPC-
HDB/HDBW31
10 Series
Record mode Auto
Device name Device factory SN
Language English
Local
setup
Video
standard NTSC NTSC
Date format Y-M-D
Time format 24H
Time zone GMT+08:00
Current time Sync PC
DST Disable
DTS type Week
Start time 00:00:00 of the first Sunday of the
month
End time 00:00:00 of the second Monday of
the month
Synchronize
with NTP Disable
NTP server clock.isc.org
Port 37
General setup
Date and time
Update
period 10m
Protocol PELCOD
Address 1
Baud rate 9600
Data bit 8
Stop bit 1
PTZ setup
Parity N/A
Auto reboot Enable
System
management
Auto maintenance Auto delete
old files Disable

11
2Structure
2.1 Multiple-function Combination Cable
You can refer to the following figure for multiple-function combination cable information. See Figure
2-1.
Figure 2-1
Please refer to the following sheet for detailed information.
Port Name Function Connection Note
VIDEO OUT Video output
port BNC Output analog video signal. It can connect to the
TV monitor to view the video.
AUDIO IN Audio input
port RCA Input audio signal. It can receive the analog audio
signal from the pickup.
AUDIO OUT Audio output
port RCA Output audio signal to the devices such as the
sound box.
12V DC/AC24V Power input
port / Power port. Input DC 12V/AC 24V
I/O I/O cable port / Connect to I/O port cable.
LAN Network port Ethernet
port
zConnect to standard Ethernet cable.
zSupport PoE.
Please refer to the follow sheet for detailed information of MD9M data converter cable.
Port Name Cable
Color Name Note
Red ALARM_COM Alarm output public port.
I/O Port
Pin
Brown ALARM_IN1 Alarm input port 1. It is to receive the on-off signal
from the external alarm source.

12
Port Name Cable
Color Name Note
Grey ALARM_IN2
Alarm input port 2. It is to receive the on-off signal
from the external alarm source.
White ALARM_NO
Alarm output port. It is to output the alarm signal
to the alarm device.
NO: normal open alarm output port.
It works with the ALARM_COM port.
Blue RESET
It is to restore factory default setup.
When the device is working properly, please
connect the blue cable (restore default setup port)
to the orange cable (GND signal) for 5 seconds,
the device can resume factory default setup.
Orange GND Ground port
2.2 Framework and Dimension
Please refer to the following two figures for dimension information. The unit is mm. See Figure 2-2 and
Figure 2-3.
Figure 2-2

13
Figure 2-3
2.3 Bidirectional talk
2.3.1 Device Connection
Before the operation, connect the active pickup to the audio input port of the device. Connect the
active speaker to the audio output port of the device. Please make sure the client-end device has the
audio input and output function. For example, you need to connect the microphone and then earphone
to the PC if you want to implement the bidirectional talk function.
2.3.2 Operation
Login the Web and click the bidirectional talk button to enable this function. Click this button again; you
can close current bidirectional talk.
2.4 Alarm Setup
The alarm interface is shown as in Figure 2-4. Please follow the steps listed below for local alarm input
and output connection.
1) Connect the alarm input device to the alarm input port (grey or brown pin of I/O port cable).
2) Connect the alarm output device to the alarm output port (White-pin) and alarm output public port
(Red-pin). The alarm output port supports NO (normal open) alarm device only.
3) Open the Web, go to the Figure 2-4. Please set the alarm input 01 port for the brown-pin (the 1st
channel) of I/O port cable. The alarm input 02 is for the grey-pin (the 2nd channel) of I/O port cable.
Then you can select the corresponding type (NO/NC.)
4) Set the WEB alarm output. The alarm output port of the alarm output 01 device (The white-pin of the
I/O port cable).

14
Figure 2-4
Table of contents
Other XtendLan IP Camera manuals

XtendLan
XtendLan XL series User manual

XtendLan
XtendLan XL-ICA-220 User manual

XtendLan
XtendLan XL-ICA-311 User manual

XtendLan
XtendLan XL-ICA-H662 User manual

XtendLan
XtendLan XL-ICA-106M2 User manual

XtendLan
XtendLan XL-ICA-301 User manual

XtendLan
XtendLan XL-ICA-106M3 User manual

XtendLan
XtendLan XL-ICA-105M2 User manual

XtendLan
XtendLan XL-ICA-370M2 User manual

XtendLan
XtendLan XL-ICA100U User manual