DPA-MRMDS setting manual
Use the DPA-MRMDS you can extend the Door Station or CCTV camera up to 4, in one
building. By using the DPA-MRMDS users can receive video call from each Door Station of monitor
each CCTV camera. Read and follow this instruction to set up the system
1. Testing map
2. Ports and Specifications
■VD/IN: Video input from Door Station
■VD/OUT: Video output to the Monitors(or Distributors)
■VD/NT: Video output to the Guard Unit
■VD/2ND: Video output for other usages
■CAM-1: Video input from Camera NO.1(or the second Door station)
■CAM-2: Video input from Camera NO.2(or the third Door station)
■CAM-3: Video input from Camera NO.3(or the fourth Door station)
■DC 12V: DC output for the Cameras
■SWITCHER: to set the address for the DPA-MRMDS, if there is only one MR- MDS
used in the building, set to 1
■A1,P-,D1,D2: connect to the A1,P-,D1,D2 of the Door Station
■P+, P-: connect to the power supply
3. Settings on the Door Station(s)
Settings must be made to all the Door Stations which connected with the MR-
MDS.
Step.1 Enable the DPA-
MRMDS
�
2
0
-
0
8
0
6
:
1
8
1. When the Door Station is on
standby mode, press #8009 on the
keyboard, then input the password(the
default password is 66666666)
1 2 3
4 5 6
7 8 9
# 0 *
[ 8 0 0 9
]
V i d e o E n t r y S y s t e
m
2. Then you will see the Advance
Config page as show at right. Press
5 on the key board to enter the HMC
setting page
[9 ] Ad v a n ced C onfig
-- - -- -- - - - - - -- --- - - - - -- --- -
-1 . To ne S e le ct [ 11 ]
-2. Image Memo [0]
-3. Voice Me m o [ 0 ]
-4. Na m e List [1 ]
-5. H MC [2]
-6. M on i to r Vers ion [0]
-7. Ca l l M o de [1]
-8. Language
-9. T i m ing [30]
-- - -- -- - - - - - -- --- - - - - -- --- -
Pr e s s 1 ~8 to select
* Back
V i d e o E n t r y S y s t e
m
3. Then you will see the HMC setting
page as show at right. Press 2 on the
keyboard and then press # key on the
keyboard to save the modification
>> [9] [ 5 ]
HMC
-
(0.. 4 )
* Back # Save
V i d e o E n t r y S y s t e
m
4. After you press the # key, a
'Updata' hint will show as right,
that means the change have save
successfully, then the screen will
return to 'Advance Config' page. If not
successful(or press the * key), the
screen will show 'Ignore Change' and
then return back
> > [ 9 ] [ 5 ]
H M C
U p d a t a
( 0 . . 4 )
* B a c k # S a v e
Step.2 Modify the settings of DPA-MRMDS
1. After enable the DPA-MRMDS, the
screen will return to the Advance Config
page, as show at right.
[9 ] Ad v a n ced C onfig
-- - -- -- - - - - - -- --- - - - - -- --- -
-1 . To ne S e le ct [ 11 ]
-2. Image Memo [0]
-3. Voice Me m o [ 0 ]
-4. Na m e List [1 ]
-5. H MC [2]
-6. M on i to r Vers ion [0]
-7. Ca l l M o de [1]
-8. Language
-9. T i m ing [30]
-- - -- -- - - - - - -- --- - - - - -- --- -
Pr e s s 1 ~8 to select
>> [9] [ 5 ]
HMC
* Back
V i d e o E n t r y S y s t e
m
-
(0.. 4 )
2. Press 5 on the key board to enter
the HMC setting page, as show at
rigth.
* Ba c k # S a v e
V i d e o E n t r y S y s t e
m
3. Press 4 and then press # on the
keyboard to enter the DPA-MRMDS
setting page as show at right. >> [9 ] [ 5 ] .4 MR-MDS
Ad d r [ - ]
■ The 'Addr[ ]' is for the MR-MDS
address setting, if there is only one
DPA-MRMDS apply the the system,
press
1 the set the address to 1.
■ The 'Ch1T[ ]' is for the monitor time
setting of the Door Station, can be
set from 0~30 seconds.
C h 1 T [ - - ]
C h 2 T [ - - ]
C h 3 T [ - - ]
Ch4T [ - -]
* Ba c k
# Save
■ The 'Ch2T[ ]' is for the monitor time
setting of the first CCTV(which
connect to the CAM-1)or the second
Door Station, can be set from 0~30
seconds.
■ The 'Ch3T[ ]' is for the monitor time
setting of the second CCTV(which
connect to the CAM-2)or the third
Door Station, can be set from 0~30
seconds.
■ The 'Ch3T[ ]' is for the monitor time
setting of the second CCTV(which
connect to the CAM-3)or the fourth
Door Station, can be set from 0~30
seconds.
V i d e o E n t r y S y s t e
m
NOTE: Set to 00 if the video channel
is not connect to any CCTV camera
of Door Station
Example 1:
The system is using one DPA-MRMDS,
and connected with one Door Station
and one CCTV camera. The Door
Station is connected to VD/IN, the
CCTV is connected to CAM-1,.
You want to set 20 seconds for the Door
Station monitoring time, and 20 seconds
for the CCTV.
>
>
[
9
]
[
5
]
.4 M
R
-
M
D
S
A
d
d
r
[
1 ]
C
h 1 T
[
2 0 ]
C h 2 T
[
2 0 ]
C h 3 T
[
0 0 ]
Ch4T
[
0 0 ]
The setting should be as show at right *
B
a ck # S a ve
V i d e o E n t r y S y s t e
m
Example 2:
The system is using one DPA-
MRMDS, and connected with two
Door Station and one CCTV camer
a. The first
Door Station is connected to VD/IN,
the second Door Station is connected
to CAM-1,the CCTV is connected to
CAM-2.
You want to set 15 seconds for the
> > [ 9 ] [ 5 ] . 4 M R - M D S
A d d r [ 1 ]
C h 1 T [ 1 5 ]
C h 2 T [ 1 0 ]
C h 3 T [ 1 2 ]
C h 4 T [ 0 0 ]
first Door Station monitoring time, 10 * B a c k # S a v e
seconds for the second Door Station
and 12 seconds for the CCTV.
The setting should be as show at right
NOTE: The two Door Stations have the
same setting for the DPA-MRMDS
function, that's the same setting from
step.1 and step.2
V
id e o E n
t
r y S y s
t
e
m
PS
DC 12V
GND
VG
VD
1 2 3
654
*
7
0
8
#
9
JW/EXT
DR2
GD
12 V
DR1
P-
A1
P+
A2
LS D1
P-
D2
VG
VD
N2
N1
N3
N4
MR-MAIN-V5
ML-
ML+
P+
J/W5E
P-
J/EVD J/W2
J/MVD
TEST
J/W1 J/W0
J/W4
VG
VD
VG
VD
VG
VD
VG
VD
VG
VD
VG
VD
A1 P- D1 D2 P+ P- PG
L-
L+
P+
P-
ML+
L+
L-
ML-
1 2 3
654
*
7
0
8
#
9
JW/EXT
DR2
GD
12 V
DR1
P-
A1
P+
A2
LS D1
P-
D2
VG
VD
N2
N1
N3
N4
MR-MAIN-V5
ML-
ML+
P+
J/W5E
P-
J/EVD J/W2
J/MVD
TEST
J/W1 J/W0
J/W4
L-
L+
P+
P-
ML+
L+
L-
ML-
Connect with electronic lock
Connect with electromagnetic lock
CAT5
RVV2*1.0mm
Wiring example for C5-system:
DPA-5C4
DPA-5C4
DPA-5C-MC
DPA-5C-MC
DPA-5C-DC
DPA-MRMDS
DPC-536 DPC-536
DPC-536 DPC-536
PS

Other XtendLan Test Equipment manuals

XtendLan TESTPTZ251GD User manual

XtendLan

XtendLan TESTPTZ251GD User manual

XtendLan TESTPTZ251G User manual

XtendLan

XtendLan TESTPTZ251G User manual

XtendLan TESTPTZ705ADHS User manual

XtendLan

XtendLan TESTPTZ705ADHS User manual

Popular Test Equipment manuals by other brands

Langer P1202 user manual

Langer

Langer P1202 user manual

Lite-Check 912 manual

Lite-Check

Lite-Check 912 manual

ETI PI-800 instruction manual

ETI

ETI PI-800 instruction manual

Viavi OLA-54 operating manual

Viavi

Viavi OLA-54 operating manual

Bosch Rexroth VT-PDFE-1X Series operating instructions

Bosch

Bosch Rexroth VT-PDFE-1X Series operating instructions

K&M KR200 instruction manual

K&M

K&M KR200 instruction manual

T&R 200A-3PH Operating and maintenance manual

T&R

T&R 200A-3PH Operating and maintenance manual

AlcoSense Ultra instruction manual

AlcoSense

AlcoSense Ultra instruction manual

JDS Uniphase OTU-8000 user manual

JDS Uniphase

JDS Uniphase OTU-8000 user manual

Solaxx SALTDIP Pro quick start guide

Solaxx

Solaxx SALTDIP Pro quick start guide

PASCO TD-8557 Instruction manual and experiment guide

PASCO

PASCO TD-8557 Instruction manual and experiment guide

Kyoritsu Electrical Instruments Works, Ltd. 4200 instruction manual

Kyoritsu Electrical Instruments Works, Ltd.

Kyoritsu Electrical Instruments Works, Ltd. 4200 instruction manual

Aqualytic Floc-Tester instruction manual

Aqualytic

Aqualytic Floc-Tester instruction manual

In-situ Aqua TROLL 500 quick start guide

In-situ

In-situ Aqua TROLL 500 quick start guide

Dräger Alcotest 3000 Instructions for use

Dräger

Dräger Alcotest 3000 Instructions for use

W Box Technologies 0E-TELBSET user manual

W Box Technologies

W Box Technologies 0E-TELBSET user manual

LaMotte 1742 PockeTester instruction manual

LaMotte

LaMotte 1742 PockeTester instruction manual

Micsig DP5013 user manual

Micsig

Micsig DP5013 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.