XtendLan DPA-MRMDS Manual

DPA-MRMDS setting manual
Use the DPA-MRMDS you can extend the Door Station or CCTV camera up to 4, in one
building. By using the DPA-MRMDS users can receive video call from each Door Station of monitor
each CCTV camera. Read and follow this instruction to set up the system
1. Testing map
2. Ports and Specifications
■VD/IN: Video input from Door Station
■VD/OUT: Video output to the Monitors(or Distributors)
■VD/NT: Video output to the Guard Unit
■VD/2ND: Video output for other usages
■CAM-1: Video input from Camera NO.1(or the second Door station)
■CAM-2: Video input from Camera NO.2(or the third Door station)
■CAM-3: Video input from Camera NO.3(or the fourth Door station)
■DC 12V: DC output for the Cameras
■SWITCHER: to set the address for the DPA-MRMDS, if there is only one MR- MDS
used in the building, set to 1
■A1,P-,D1,D2: connect to the A1,P-,D1,D2 of the Door Station
■P+, P-: connect to the power supply
3. Settings on the Door Station(s)
Settings must be made to all the Door Stations which connected with the MR-
MDS.
Step.1 Enable the DPA-
MRMDS
�
2
0
-
0
8
0
6
:
1
8
1. When the Door Station is on
standby mode, press #8009 on the
keyboard, then input the password(the
default password is 66666666)
1 2 3
4 5 6
7 8 9
# 0 *
[ 8 0 0 9
]
V i d e o E n t r y S y s t e
m
2. Then you will see the Advance
Config page as show at right. Press
5 on the key board to enter the HMC
setting page
[9 ] Ad v a n ced C onfig
-- - -- -- - - - - - -- --- - - - - -- --- -
-1 . To ne S e le ct [ 11 ]
-2. Image Memo [0]
-3. Voice Me m o [ 0 ]
-4. Na m e List [1 ]
-5. H MC [2]
-6. M on i to r Vers ion [0]
-7. Ca l l M o de [1]
-8. Language
-9. T i m ing [30]
-- - -- -- - - - - - -- --- - - - - -- --- -
Pr e s s 1 ~8 to select
* Back
V i d e o E n t r y S y s t e
m
3. Then you will see the HMC setting
page as show at right. Press 2 on the
keyboard and then press # key on the
keyboard to save the modification
>> [9] [ 5 ]
HMC
-
(0.. 4 )
* Back # Save
V i d e o E n t r y S y s t e
m
4. After you press the # key, a
'Updata' hint will show as right,
that means the change have save
successfully, then the screen will
return to 'Advance Config' page. If not
successful(or press the * key), the
screen will show 'Ignore Change' and
then return back
> > [ 9 ] [ 5 ]
H M C
U p d a t a
( 0 . . 4 )
* B a c k # S a v e
Step.2 Modify the settings of DPA-MRMDS
1. After enable the DPA-MRMDS, the
screen will return to the Advance Config
page, as show at right.
[9 ] Ad v a n ced C onfig
-- - -- -- - - - - - -- --- - - - - -- --- -
-1 . To ne S e le ct [ 11 ]
-2. Image Memo [0]
-3. Voice Me m o [ 0 ]
-4. Na m e List [1 ]
-5. H MC [2]
-6. M on i to r Vers ion [0]
-7. Ca l l M o de [1]
-8. Language
-9. T i m ing [30]
-- - -- -- - - - - - -- --- - - - - -- --- -
Pr e s s 1 ~8 to select
>> [9] [ 5 ]
HMC
* Back
V i d e o E n t r y S y s t e
m
-
(0.. 4 )
2. Press 5 on the key board to enter
the HMC setting page, as show at
rigth.
* Ba c k # S a v e
V i d e o E n t r y S y s t e
m
3. Press 4 and then press # on the
keyboard to enter the DPA-MRMDS
setting page as show at right. >> [9 ] [ 5 ] .4 MR-MDS
Ad d r [ - ]
■ The 'Addr[ ]' is for the MR-MDS
address setting, if there is only one
DPA-MRMDS apply the the system,
press
1 the set the address to 1.
■ The 'Ch1T[ ]' is for the monitor time
setting of the Door Station, can be
set from 0~30 seconds.
C h 1 T [ - - ]
C h 2 T [ - - ]
C h 3 T [ - - ]
Ch4T [ - -]
* Ba c k
# Save
■ The 'Ch2T[ ]' is for the monitor time
setting of the first CCTV(which
connect to the CAM-1)or the second
Door Station, can be set from 0~30
seconds.
■ The 'Ch3T[ ]' is for the monitor time
setting of the second CCTV(which
connect to the CAM-2)or the third
Door Station, can be set from 0~30
seconds.
■ The 'Ch3T[ ]' is for the monitor time
setting of the second CCTV(which
connect to the CAM-3)or the fourth
Door Station, can be set from 0~30
seconds.
V i d e o E n t r y S y s t e
m
NOTE: Set to 00 if the video channel
is not connect to any CCTV camera
of Door Station
Example 1:
The system is using one DPA-MRMDS,
and connected with one Door Station
and one CCTV camera. The Door
Station is connected to VD/IN, the
CCTV is connected to CAM-1,.
You want to set 20 seconds for the Door
Station monitoring time, and 20 seconds
for the CCTV.
>
>
[
9
]
[
5
]
.4 M
R
-
M
D
S
A
d
d
r
[
1 ]
C
h 1 T
[
2 0 ]
C h 2 T
[
2 0 ]
C h 3 T
[
0 0 ]
Ch4T
[
0 0 ]
The setting should be as show at right *
B
a ck # S a ve
V i d e o E n t r y S y s t e
m
Example 2:
The system is using one DPA-
MRMDS, and connected with two
Door Station and one CCTV camer
a. The first
Door Station is connected to VD/IN,
the second Door Station is connected
to CAM-1,the CCTV is connected to
CAM-2.
You want to set 15 seconds for the
> > [ 9 ] [ 5 ] . 4 M R - M D S
A d d r [ 1 ]
C h 1 T [ 1 5 ]
C h 2 T [ 1 0 ]
C h 3 T [ 1 2 ]
C h 4 T [ 0 0 ]
first Door Station monitoring time, 10 * B a c k # S a v e
seconds for the second Door Station
and 12 seconds for the CCTV.
The setting should be as show at right
NOTE: The two Door Stations have the
same setting for the DPA-MRMDS
function, that's the same setting from
step.1 and step.2
V
id e o E n
t
r y S y s
t
e
m
PS
DC 12V
GND
VG
VD
1 2 3
654
*
7
0
8
#
9
JW/EXT
DR2
GD
12 V
DR1
P-
A1
P+
A2
LS D1
P-
D2
VG
VD
N2
N1
N3
N4
MR-MAIN-V5
ML-
ML+
P+
J/W5E
P-
J/EVD J/W2
J/MVD
TEST
J/W1 J/W0
J/W4
VG
VD
VG
VD
VG
VD
VG
VD
VG
VD
VG
VD
A1 P- D1 D2 P+ P- PG
L-
L+
P+
P-
ML+
L+
L-
ML-
1 2 3
654
*
7
0
8
#
9
JW/EXT
DR2
GD
12 V
DR1
P-
A1
P+
A2
LS D1
P-
D2
VG
VD
N2
N1
N3
N4
MR-MAIN-V5
ML-
ML+
P+
J/W5E
P-
J/EVD J/W2
J/MVD
TEST
J/W1 J/W0
J/W4
L-
L+
P+
P-
ML+
L+
L-
ML-
Connect with electronic lock
Connect with electromagnetic lock
CAT5
RVV2*1.0mm
Wiring example for C5-system:
DPA-5C4
DPA-5C4
DPA-5C-MC
DPA-5C-MC
DPA-5C-DC
DPA-MRMDS
DPC-536 DPC-536
DPC-536 DPC-536
PS

Other XtendLan Test Equipment manuals

XtendLan TESTPTZ251G User manual

XtendLan

XtendLan TESTPTZ251G User manual

XtendLan TESTPTZ251GD User manual

XtendLan

XtendLan TESTPTZ251GD User manual

XtendLan TESTPTZ705ADHS User manual

XtendLan

XtendLan TESTPTZ705ADHS User manual

Popular Test Equipment manuals by other brands

Endress+Hauser nivotester FTL 372-F2E1 manual

Endress+Hauser

Endress+Hauser nivotester FTL 372-F2E1 manual

Platinum Tools Net Prowler TNP700 quick start guide

Platinum Tools

Platinum Tools Net Prowler TNP700 quick start guide

Compliance West MegaPulse Capacitor A PF Series instruction manual

Compliance West

Compliance West MegaPulse Capacitor A PF Series instruction manual

NeuroTek Elite Series quick start guide

NeuroTek

NeuroTek Elite Series quick start guide

Fluke 190-062/AM Product data

Fluke

Fluke 190-062/AM Product data

RHEINTACHO RT STROBE qbLEDs quick start guide

RHEINTACHO

RHEINTACHO RT STROBE qbLEDs quick start guide

koslow The Alloy Scout 1545 quick start guide

koslow

koslow The Alloy Scout 1545 quick start guide

BEAMEX MC6-WS manual

BEAMEX

BEAMEX MC6-WS manual

LION Alcolmeter 700 User handbook

LION

LION Alcolmeter 700 User handbook

Tektronix MDO4104-6 instructions

Tektronix

Tektronix MDO4104-6 instructions

Objectif Prévention Ethylec Plus manual

Objectif Prévention

Objectif Prévention Ethylec Plus manual

Kikusui TOS5200 Setup guide

Kikusui

Kikusui TOS5200 Setup guide

Alcolizer HH4 user manual

Alcolizer

Alcolizer HH4 user manual

Humboldt Digital MasterLoader HM-3000.3F product manual

Humboldt

Humboldt Digital MasterLoader HM-3000.3F product manual

Digatron DT-47FT manual

Digatron

Digatron DT-47FT manual

ELECTROMATIC WTT-110 user manual

ELECTROMATIC

ELECTROMATIC WTT-110 user manual

Scientific SMO2000X user manual

Scientific

Scientific SMO2000X user manual

OWL ZOOM 2 Series Quick reference guide

OWL

OWL ZOOM 2 Series Quick reference guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.