YELLOWRIVER YR-L0308T User manual

LED SLIM BAR
Model
354SD
YR-L0308T
YR-L0309S

Contents
Section 1.Getting Started
Unpacking
Safety Instruction
Section 2. Set Up
Installation
Controlling Board
Machine Connection
Section 3. troubleshooting
Troubleshooting
Section 4. Reference
Control Menu
DMX Protocol
Dimmer Curve
Specification
Section 1.Getting Started
Unpacking
Safety Instruction
本公司有权对此份产品说明书进行修改,恕不另行通知。
Our company reserve right to revise this user manual without notice!
Innovation | Efficiency | Dedication | Harmonious

Specification
Voltage:AC110V-240V
Frequency:50/60Hz
Machine Power:25W
Led source: L0308T: 8pcsx3W(RGB 3 IN 1)
L0309S: 9pcsx3W(R:3,G:3,B:3)
Beam Angle:110° (with reflector cup)
Strobe: 0~20Hz
Dimmer :1 standard +4 kinds of dimmer methods
Channel:9/4CH(switchable)
Control Mode:DMX512/Manual/Master-Slave/Sound active
Cooling way: no fan, naturally cooling
Noise: silent
Display: LED Display
DMX: 3-pin XLR
IP: IP20
Net weight:0.75kg
Size:41.5*5.7*11.7CM
Unpacking
1pc Fixture
1pc User Manual
Thanks for choosing our LED slim bar. Carefully unpack the box and check the
contents to ensure that all parts are present and in good conditions. If anything

damaged in transit, notify the shipper immediately and keep the packing material
for inspection. Again, please save the carton and all packing materials. If
a fixture must be returned to manufacturer, it is important that the fixture
be returned in the original manufacturer box and packing.
Safety Instruction
Please conserve this manual as operation guidance. If you sell this product to
other user, please make sure that they also receive this user manual.
Always make sure that you are connecting to the proper voltage and that the
line voltage you are connecting to is not higher than that stated on the decal or
rear panel of the fixture.
If the fixture is intended to indoor use only. To prevent risk of fire or shock, do
not expose fixture to rain or moisture. Make sure there are no flammable,
explosive or corrosive materials surrounded in 10meters while operating.
The unit must be installed in a location with adequate ventilation, at least 5m
away from adjacent surfaces. Be sure that no ventilation slots are blocked.
Some fixture may carry high heat, do not aim at objective more than 2minutes.
Safe rope should be used to install machine. Bearing of safe rope should be
more than 3times of the machine weight. Complimentary signal cable transmits
signals to 20 unit fixtures at most. Signal amplifier is a must to connect more
fixtures. And a terminal should be added at the end of last fixtures’ DMX
sockets, 120 Ohm, 1/4W resistance need welding between Pin 2 and Pin3.
Always disconnect from the power source before servicing or replacing
fuse/lamp and be sure to replace with same fuse/lamp size and type. Cut off
power before moving, repairing and cleaning the machine.
To avoid electric shock, all fixtures must be connected to circuits with a suitable
earth connection.
Always secure fixture using a safety chain and carrying handles.
Do not operate at ambient temperatures higher than 104℉(40℃).
For your safe, please read this user manual carefully before turn on
the fixture. This machine should be operated by qualified engineer!

The power cable for this fixture is 1 m㎡, please mind the safety requirements
in actual using, if any wrong operation, our company takes no responsibility for
any loss. Also, make sure the power cord is never crimped or damaged.
DMX512 Channel Chart:(4CH)
CH1
Dimmer
0-255 RGBW Dimmer, from dark to bright
CH2
Red dimmer
0-255 Red from dark to bright
CH3
Green dimmer
0-255 Green from dark to bright
CH4
Blue dimmer
0-255 Blue from dark to bright
Dimmer Curves:
Ramp Effect
Menu
Tup(ms)
Tdown(ms)
Standard Dimmer
Curve
dr-0
0
0
Dimmer Curve1
dr-1
980
1010
Dimmer Curve2
dr-2
1210
1320
Dimmer Curve3
dr-3
1600
1710
Dimmer Curve4
dr-4
1850
1980
176-185:Aqua

186-195:Light Green
196-205:Cool White
206-215:light cold white
216-225:Pure White
226-235:Purple White
236-245:Rice white
246-255:Warm White
CH7
Auto & Sound
Active
0- 10: N/A
11-40: Full colors fade,
41-70: Red, Green, Blue fade;
71-100: Red, Green, Blue fade+ full bright white
101-130: 7 colors jumping
131-160: Red, Green, Blue Color jumping
161-190, Yellow, Cyan, Purple color jumping
191-220, Sound active Strobe
221-255, Sound active jumping
CH8
Auto Speed
0-255 Auto speed ,from slow to fast
CH9
Dimmer Curve
0-20:Standard Curve
021-040:Dimmer Curve1;
041-060:Dimmer Curve2;
061-080:Dimmer Curve3;
081-100:Dimmer Curve4;
101-255:N/A
In case of failure or mis-function occurred, stop using immediately. Never try to
repair the fixture by yourself. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical
assistance center. Buy the same spare parts/components from manufacturer
directly.
Avoid direct eye exposure to the light source while it is on.
Do not power on and power off the fixture frequently
When use DMX controller, please make sure that there is no interference
sources(e.g. intercom, high frequency radio waves and radiation source)
Caution! There are no user serviceable parts inside the unit. Do not open the housing or

attempt any repairs yourself. In the unlikely event your unit may require service, please contact
your local distribution or after-sale service center.
Section 2. Set Up
Installation
Controlling Board
Machine connection
Installation
This machine should be mounted through the screw holes of truss. Safety
rope is a must to fix fixture well. Make sure truss and safety rope have strong
load capacity to bear more than 3 times of machine weight.
This machine should be installed by qualified technician.
Controlling Board
Front display panel
Back panel
1. LED Display Panel
2. Button

Menu
Switch menu function
UP
Scroll upwards
DOWN
Scroll downwards
ENTER
Confirm by pressing ENTER
DMX protocol
DMX512 Channel Chart:(9CH)
CH
Function
Specification
CH1
Dimmer
0-255 RGB Dimmer, from dark to bright
CH2
Red dimmer
0-255 Red from dark to bright
CH3
Green dimmer
0-255 Green from dark to bright
CH4
Blue dimmer
0-255 Blue from dark to bright
CH5
Strobe
0-5 N/A
6-55: Random Strobe
56-105: Pulse Strobe
106-155: Average Strobe
156-205: Thunder Strobe
206-255: Standard Strobe
CH6
Color Preset
0-5:N/A
6-15:Red
16-25:Green
26-35: Blue
36-45:Lemon Green
46-55:Yellow Green
56-65:Yellow
66-75:Tea Red
76-85: Light Orange
86-95:Rose Red
96-105:Pink
106-115:Pink Purple
116-125:Lilac
126-135:Powder Blue
136-145:Light Blue
146-155:Sky Blue
156-165:Light Cyan
166-175:Turquoise

pr15:Sky Blue
pr16:Light Cyan
pr17:Turquoise
pr18:Aqua
pr19: Light Green
pr20:Cool White
pr21:Light Cool white
pr22:Pure White
pr23:Purple White
pr24:Rice White
pr25:Warm White
7
F---
F000 to F255:Strobe(from slow to fast)
8
C---
C000 to C255: Full color fade,from slow to fast
9
J---
J000 to J255:Full color jump,from slow to fast
10
S---
S000 to S255:Sound active,from slow to fast
11
dr
dr-0:Standard Dimmer Curve;
dr-1:Dimmer Curve1;
dr-2:Dimmer Curve2;
dr-3:Dimmer Curve3;
dr-4:Dimmer Curve4;
3. DMX Signal Input
3 PIN XRL port for DMX512 signal input ( daisy chain);
4. DMX signal output
3 PINXRL Port for DMX512 signal output ( daisy chain);
5. Power Input/output
AC power cable port input/output
Cable Connectors
Cables must have a male XLR connector on one end and a female XLR connector on the other
end.

A word on termination: DMX is a resilient communication protocol,
however errors still occasionally occur. Termination reduces signal errors, and therefore best
practices include use of a terminator in all circumstances. If you are experiencing problems with
erratic fixture behavior, especially over long signal cable runs, a terminator may help improve
performance.
To build your own DMX Terminator: Obtain a 120-ohm, 1/4-watt
resistor, and wire it between pins 2&3 of the last fixture. They are also readily available from
specialty retailers.
Master and slave: select one machine as master, press the menu to choose the
function you want. Press other machines’ address to be DMX state. Use signal
cable to connect machines one by one. Then slave machines will run the same as
master machine.
Use controller to control lot of machines: if all machines are set the same menu
data, or different manual data, after use signal cable to connect to controller, all
machines will be controlled by controller. (before connect to controller, all
machines should be in the same channel mode 9ch or 4ch).
Section 3. Troubleshooting
Problem
Probable Cause(s)
Remedy
No power to fixture
Check power cables
Primary fuse blown
Replace fuse
No response from
fixture when power
is applies
Secondary fuse
blown
Replace fuse
Controller not
connected
Connect controller
Incorrect
addressing of the
fixtures
Check address setting on fixture and controller
Bad data link
connection
Inspect cables and correct poor connections
and/or broken cables.
Conflict between
tracking and vector
control
Eliminate scene cross-fade on controller
Data link not
terminated
Insert termination plug in output of last fixture
Fixture resets but
does not respond
correctly to
controller(DMX
mode operation)
Defective fixture or
2 devices
transmitting on link
Bypass fixtures one at a time until normal
operation is regained: unplug both connectors
and connect them directly together
Colors cannot be
mixed
Random color
mixing is on
Turn off random color mixing
Fixture does not
Electronic or
Contact service technician

reset correctly
mechanical failure
Lamp missing or
blown
Disconnect fixture and replace lamp
No light, lamp cuts
out intermittently, or
burns out too
quickly
Fixture or lamp is
too hot
Allow fixture to cool. If problem persists,contact
service technician
Section 4. Reference
Control Menu
DMX Protocol
Dimmer Curve
Specification
Control Menu
No.
Menu
Function
1
d9 --
DMX 9 channel control(need connecting controller)
2
d.4--
DMX4channel control(need connecting controller)
3
r---
r000 to r255: Red from dark to bright
4
g---
g000 to g255: Green from dark to bright
5
b---
b000 to b255: Blue from dark to bright
6
pr--
pr01~pr25:25 kinds of preset colors:
pr01:Red
pr02:Green
pr03: Blue
pr04: Lemon Green
pr05:Yellow Green
pr06:Yellow
pr07:Tea Red
pr08:Light orange
pr09:Rose Red
pr10:pink
pr11:Pink Purple
pr12:Light Purple
pr13:Powder Blue
pr14:Light Blue
This manual suits for next models
1
Table of contents
Other YELLOWRIVER Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Sunoptic Surgical
Sunoptic Surgical Titan 400HP Operator's manual

kim lighting
kim lighting Hubbell LIGHTVAULT LTV30 installation instructions

Costway
Costway ES10022US-SL user manual

ALW
ALW SUPERPLANE2.5 installation instructions

Viviox
Viviox E600-S Installation and operational guide

Promate
Promate SolarWay-3 user guide