YOKOGAWA GX60 User manual

User’s
Manual
IM 04L51B01-02EN
8th Edition
Model GX10/GX20/GP10/GP20
Paperless Recorder
First Step Guide
Contents
Introduction................................................................................. 1
Handling Precautions of the GX/GP ............................................ 5
SD Memory Card Handling Precautions ...................................... 5
Checking the Package Contents ................................................. 5
Standard Accessories ................................................................. 8
Conventions Used in This Manual ............................................... 9
Protection of Environment ..........................................................10
Functional Overview ...................................................... 11
Overview ...................................................................................11
A Variety of Source Signals ........................................................11
Expandable Module Construction...............................................11
GX60 Connection and Multichannel Measurement .....................11
High-speed Measurement, Dual Interval Measurement (Measurement
mode) ....................................................................................12
Loop Control and Program Control Function (/PG Option)..........12
Data Storage .............................................................................12
A Variety of Display Functions ....................................................12
Touch Screen ............................................................................13
Freehand Messages ..................................................................13
Versatile Network Functions and Software .................................13
Other Functions ........................................................................ 14
System Conguration ................................................................15
Component Names ........................................................16
GX20/GX10...............................................................................16
GP20/GP10 ...............................................................................17
GX60/GX90EX..........................................................................17
GX90XA/GX90XD/GX90YD/GX90WD/GX90XP/GX90YA/GX90UT
..............................................................................................18
Operating Procedure......................................................20
Installation and Wiring....................................................22
Installation Location................................................................... 22
Installation Procedure................................................................ 23
External Dimensions and Panel Cut Dimensions........................ 23
Connect an GX60 ..................................................................... 25
Installing and Removing I/O Modules ......................................... 26
Wiring ....................................................................................... 28
Basic Operation..............................................................37
Turning the Power On and Off................................................... 37
Setting and Removing SD Memory Cards ................................. 38
Viewing the Operation Screen (Trend)....................................... 38
Displaying the Menu Screen...................................................... 39
Setting the Date and Time*........................................................ 39
Conguring the Inputs ............................................................... 40
Starting Measurement and Recording ....................................... 40
Switching between Operation Screens...................................... 40
Saving Data to USB Memory .................................................... 41
Switching the Quick Settings (GP only)...................................... 41
Advanced Operation (Various settings and operation) 42
Setting Measurement and Recording Conditions ....................... 42
Setting Alarms .......................................................................... 42
Alarm DO output ....................................................................... 43
Using the Scaling Function (Measuring a ow meter) ................. 43
Using the Scaling Function (Measuring a temperature) .............. 44
Registering and Deleting Favorite Screens ................................ 44
Setting the Measurement Mode.....................................45
Setting the Measurement Mode ................................................ 45
Limitations................................................................................. 45
Reconguring the GX/GP (Module identication).........46
Reconguring the GX/GP.......................................................... 46
Initializing the GX/GP
(Initializing all settings) ........................................................... 46
Saving and Loading Setting Parameters.......................47
Saving Setting Parameters........................................................ 47
Loading Setup Parameters ....................................................... 47
Web Application .............................................................48
Starting the Web Application ..................................................... 48
Closing the Web Application...................................................... 48
Application Software......................................................49
PC System Requirements......................................................... 49
Installation................................................................................. 49
Starting and Closing Universal Viewer ....................................... 50
Starting and Closing Hardware Congurator.............................. 50
Setup Menu Map.............................................................51
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

PRS 108-02E
User Registration
Thank you for purchasing YOKOGAWA products.
We invite you to register your products in order to receive the most up to date product
information. To register, visit the following URL.
http://www.yokogawa.com/ns/reg/
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

1
IM 04L51B01-02EN
Introduction
Thank you for purchasing the SMARTDAC+ GX/GP
Series Paperless Recorder (hereafter referred to as the
GX/GP). This manual explains the basic operation,
installation, and wiring of the GX/GP.
For details on configuring and operating the GX/GP, see
the “ Paperless Recorder User’s Manual (IM 04L51B01-
01EN) “ provided in electronic format.
For details on the settings and operation of the PID
control module and program control (/PG option), see the
Loop Control Function, Program Control Function (/PG
Option) User’s Manual (IM 04L51B01-31EN), provided as
an electronic manual.
This manual supports the following products.
Model Product Name
GX10/GX20 Paperless Recorder (panel mount type)
GP10/GP20 Paperless recorder (portable type)
GX60 I/O Base Unit (Expandable I/O)
Although the display of GX20 is used in this guide,
GX10/GP10/GP20 can be operated similarly.
This manual denotes devices with their product names or
model (e.g. GX60).
To ensure correct use, please read this manual and the
following manuals thoroughly before beginning operation.
For a detailed description of the product, see the
electronic manual.
For specifications, refer to General Specifications.
Paper Manuals
Manual Title Manual No.
Models GX10/GX20/GP10/GP20
Paperless Recorder First Step Guide
IM 04L51B01-02EN
(This manual)
Precaution on the use of SMARTDAC+
(Only delivered with each module or GX60)
IM 04L51B01-91EN
Electronic Manuals
You can download these manuals from the following web
page:
www.smartdacplus.com/manual/en/
Manual Title Manual No.
Model GX10/GX20/GP10/GP20
Paperless Recorder First Step Guide
IM 04L51B01-02EN
Model GX10/GX20/GP10/GP20
Paperless Recorder User’s Manual
IM 04L51B01-01EN
Model GX10/GX20/GP10/GP20/GM10
Communication Command User’s Manual
IM 04L51B01-17EN
SMARTDAC+ STANDARD Universal Viewer
User’s Manual
IM 04L61B01-01EN
SMARTDAC+ STANDARD Hardware Configurator
User’s Manual
IM 04L61B01-02EN
Model GX10/GX20/GP10/GP20/GM10
Multi-batch Function (/BT) User’s Manual
IM 04L51B01-03EN
Model GX10/GX20/GP10/GP20
Advanced Security Function (/AS) User’s Manual
IM 04L51B01-05EN
Model GX10/GX20/GP10/GP20/GM10
EtherNet/IP Communication (/E1) User’s Manual
IM 04L51B01-18EN
Model GX10/GX20/GP10/GP20/GM10
WT Communication (/E2) User’s Manual
IM 04L51B01-19EN
Model GX10/GX20/GP10/GP20/GM10
OPC-UA Server (/E3) User’s Manual
IM 04L51B01-20EN
Model GX10/GX20/GP10/GP20/GM10
SLMP Communication (/E4) User’s Manual
IM 04L51B01-21EN
Model GX10/GX20/GP10/GP20/GM10
LOG scale (/LG) User’s Manual
IM 04L51B01-06EN
Model GX10/GX20/GP10/GP20/GM10
Loop Control Function, Program Control Function (/PG
Option) User’s Manual
IM 04L51B01-31EN
DXA170 DAQStudio User’s Manual IM 04L41B01-62EN
Precaution on the use of SMARTDAC+ IM 04L51B01-91EN
General Specifications
Title General
specifications No.
GX10/GX20 Paperless Recorder (panel mount type)
GS 04L51B01-01EN
GP10/GP20 Paperless Recorder (portable type)
GS 04L52B01-01EN
GX60 I/O Base Unit (Expandable I/O) / GX90EX Expansion
Module
GS 04L53B00-01EN
GX90XA/GX90XD/GX90YD/GX90WD/GX90XP/GX90YA
I/O modules
GS 04L53B01-01EN
GX90UT PID Control Module
GX10/GX20/GP10/GP20 Paperless Recorder
Data Acquisition System GM
Loop Control Function, Program Control Function (/PG
Option)
GS 04L53B01-31EN
* The last two characters of the manual number and
general specification number indicate the language in
which the manual is written.
Installing the Java Runtime Environment (JRE)
Download JRE from the following site, and install it.
<http://www.smartdacplus.com/software/en/>
Notes
• The contents of this manual are subject to change
without prior notice as a result of continuing
improvements to the instrument’s performance and
functions.
• Every effort has been made in the preparation of
this manual to ensure the accuracy of its contents.
However, should you have any questions or find any
errors, please contact your nearest Yokogawa dealer.
• Copying or reproducing all or any part of the contents
of this manual without the permission of Yokogawa is
strictly prohibited.
Authorised Representative in the EEA
The Authorised Representative for this product in the EEA is:
Yokogawa Europe B.V.
Euroweg 2, 3825 HD Amersfoort,The Netherlands
Revisions
December 2012 1st Edition December 2014 5th Edition
February 2013 2nd Edition December 2015 6th Edition
May 2013 3rd Edition June 2017 7th Edition
May 2014 4th Edition November 2017 8th Edition
Trademarks
• SMARTDAC+ and SMARTDACPLUS are registered
trademark of Yokogawa Electric Corporation.
•
Microsoft and Windows are registered trademarks or
trademarks of Microsoft Corporation in the United States
and/or other countries.
• Pentium is a trademark of Intel Corporation in the
United States and/or other countries.
•
Adobe and Acrobat are registered trademarks or
trademarks of Adobe Systems Incorporated.
• Kerberos is a trademark of Massachusetts Institute of
Technology (MIT).
• The SD logo is a registered trademark of the SD
association.
• Company and product names that appear in this
manual are registered trademarks or trademarks of
their respective holders.
• The company and product names used in this manual
are not accompanied by the registered trademark or
trademark symbols (® and ™).
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

2IM 04L51B01-02EN
Manual guide for various items and functions
Imtem, Function Main manual
Document name
No.
Related manuals
User’s Manual
IM 04L51B01-01EN
Communication
Command User’s
Manual
IM 04L51B01-17EN
Paperless Recorder
First Step Guide
IM 04L51B01-02EN
Standard
settings,operation
Communication comand Installation and Wiring
Safety Precautions,
Installation and Wiring,
Basic operation of the
GX/GP
First Step Guide
IM 04L51B01-02EN
basic operation and
setting of the GX/GP.
User’s Manual
IM 04L51B01-01EN
Math function (/MT) User’s Manual
IM 04L51B01-01EN
Report function (/MT) User’s Manual
IM 04L51B01-01EN
Report Template Function
(/MT)
User’s Manual
IM 04L51B01-01EN
Batch Function User’s Manual
IM 04L51B01-01EN
Modbus Function User’s Manual
IM 04L51B01-01EN
DARWIN compatible
communication function
User’s Manual
IM 04L51B01-01EN
Communication channel
function (/MC)
User’s Manual
IM 04L51B01-01EN
Serial communication
function (/C2, /C3)
User’s Manual
IM 04L51B01-01EN
Advanced security
function (Part 11)
Advanced Security
Function (/AS)
User’s Manual
IM 04L51B01-05EN
EtherNet/IP
Communication (/E1)
EtherNet/IP
Communication (/E1)
User’s Manual
IM 04L51B01-18EN
WT Communication (/E2) WT Communication (/E2)
User’s Manual
IM 04L51B01-19EN
Aerospace heat treatment
(/AH)
User’s Manual
IM 04L51B01-01EN
Multi Batch Function (/BT) Multi Batch Function (/BT)
User’s Manual
IM 04L51B01-03EN
OPC-UA Server (/E3) OPC-UA Server (/E3)
User’s Manual
IM 04L51B01-20EN
SLMP Communication (/
E4)
SLMP Communication (/
E4)
User’s Manual
IM 04L51B01-21EN
Custom Display (/CG
option)
DXA170 DAQStudio
IM 04L41B01-62EN
Log Scale (/LG) Log Scale (/LG)
User’s Manual
IM 04L51B01-06EN
Loop Control Function,
Program Control Function
(/PG)
Loop Control Function,
Program Control Function
(/PG Option)
User’s Manual
IM 04L51B01-31EN
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

3
IM 04L51B01-02EN
Safety Precautions
• This instrument conforms to IEC safety class I
(provided with terminal for protective grounding),
Installation Category II, and EN61326-1 (EMC
standard), Measurement Category II (CAT II).*
* Measurement Category II (CAT II) are for the analog
input modules (GX90XA) and PID control mopdule
(GX90UT).
Measurement category II (CAT II) applies to
measuring circuits connected to low voltage
installation, and electrical instruments supplied
with power from fixed equipment such as electric
switchboards.
• This instrument is an EN61326-1 (EMC standard)
class A instrument (for use in commercial, industrial, or
business environments). The influence rate (judgment
condition A) in the immunity test environment is within ±
10 % of the range.
• The general safety precautions described here must
be observed during all phases of operation. If the
SMARTDAC+ is used in a manner not described in
this manual, the SMARTDAC+ safety features may be
impaired. Yokogawa Electric Corporation assumes no
liability for the customer’s failure to comply with these
requirements.
• The SMARTDAC+ is designed for indoor use.
■ About This Manual
• Please pass this manual to the end user. We also ask
you to store this manual in a safe place.
• This guide is intended for the following personnel:
Engineers responsible for installation, wiring, and
maintenance of the equipment.
Personnel responsible for normal daily operation of the
equipment.
• Read this manual thoroughly and have a clear
understanding of the product before operation.
• This manual explains the functions of the product. It
does not guarantee that the product will suit a particular
purpose of the user.
■ Precautions Related to the Protection, Safety,
and Alteration of the Product
The following safety symbols are used on the product
and in this manual.
“Handle with care.” To avoid injury and damage to the instrument,
the operator must refer to the explanation in the manual.
Protective ground terminal
Functional ground terminal
(do not use this terminal as a protective ground terminal.)
Alternating current
Direct current
ON (power)
OFF (power)
• For the protection and safe use of the product and the
system in which this product is incorporated, be sure
to follow the instructions and precautions on safety
that are stated in this manual whenever you handle the
product.
Take special note that if you handle the product in a
manner that violates these instructions, the protection
functionality of the product may be damaged or
impaired. In such cases, Yokogawa does not guarantee
the quality, performance, function, and safety of
product.
• When installing protection and/or safety circuits such
as lightning protection devices and equipment for the
product and control system or designing or installing
separate protection and/or safety circuits for fool-proof
design and fail-safe design of the processes and lines
that use the product and the control system, the user
should implement these using additional devices and
equipment.
• If you are replacing parts or consumable items of
the product, make sure to use parts specified by
Yokogawa.
• This product is not designed or manufactured to
be used in critical applications that directly affect
or threaten human lives. Such applications include
nuclear power equipment, devices using radioactivity,
railway facilities, aviation equipment, air navigation
facilities, aviation facilities, and medical equipment. If
so used, it is the user’s responsibility to include in the
system additional equipment and devices that ensure
personnel safety.
• Do not modify this product.
●Use the Correct Power Supply
Ensure that the source voltage match-
es the voltage of the power supply be-
fore turning ON the power. In the case
of portable type and the GX60 (power
inlet type), ensure that it is within the
maximum rated voltage range of the
provided power cord before connect-
ing the power cord.
● Use the Correct Power Cord and Plug
(Portable Type, GX60 (power inlet
type))
To prevent electric shock or re, be
sure to use the power cord supplied
by Yokogawa. The main power plug
must be plugged into an outlet with a
protective earth terminal. Do not dis-
able this protection by using an ex-
tension cord without protective earth
grounding.
The power cord is designed for use
with this instrument. Do not use the
power cord with other instruments.
● Connect the Protective Grounding
Terminal
Make sure to connect the protective
grounding to prevent electric shock
before turning ON the power.
The power cord that comes with the
portable type and the GX60 (power
inlet type) are three prong type power
cord. Connect the power cord to a
properly grounded three-prong outlet.
● Do Not Impair the Protective Ground-
ing
Never cut off the internal or external
protective grounding wire or dis-
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

4
IM 04L51B01-02EN
■ Exemption from Responsibility
• Yokogawa makes no warranties regarding the product
except those stated in the WARRANTY that is provided
separately.
• Yokogawa assumes no liability to any party for any loss
or damage, direct or indirect, caused by the user or any
unpredictable defect of the product.
■ Software Handling Precautions
• Yokogawa makes no warranties, either expressed or
implied, with respect to the software’s merchantability
or suitability for any particular purpose, except as
specified in the terms of the separately provided
warranty.
• All reverse-engineering operations, such as reverse
compilation or the reverse assembly of the product are
strictly prohibited.
• No part of the product’s software may be transferred,
converted, or sublet for use by any third party, without
prior written consent from Yokogawa.
About the Usage of Open Source Software
关于开放源代码软件的使用
This products uses open source software.
For details on using open source software, see Regarding
the Downloading and Installing
for the Software, Manuals and Labels (IM 04L61B01-
11EN).
connect the wiring of the protective
grounding terminal. Doing so invali-
dates the protective functions of the
instrument and poses a potential
shock hazard.
● Do Not Operate with Defective Protec-
tive Grounding
Do not operate the instrument if the
protective grounding might be defec-
tive. Also, make sure to check them
before operation.
● Do Not Operate in an Explosive Atmo-
sphere
Do not operate the instrument in the
presence of ammable gas, vapors, or
combustible dust. Operation in such
an environment constitutes a safety
hazard. Prolonged use in a highly
dense corrosive gas (H2S, SOx, etc.)
will cause a malfunction.
● Do Not Remove Covers
The cover should be removed by
Yokogawa’s qualied personnel only.
Opening the cover is dangerous,
because some areas inside the instru-
ment have high voltages.
● Ground the Instrument before Making
External Connections
Connect the protective grounding
before connecting to the item under
measurement or control unit.
● Damage to the Protection
Operating the instrument in a man-
ner not described in this manual may
damage the instrument’s protection.
● Wiring
To prevent shock, attach the included
terminal cover after wiring. Make sure
to use appropriate wires and crimp-on
lugs.
If hazardous external voltage (30 V
AC or 60 V DC or more) is applied to
the I/O terminals, provide adequate
protection to prevent users or service
engineers from suddenly touching
the terminals or tools or the like from
coming in contact with the terminals.
This instrument is a Class A product.
Operation of this instrument in a
residential area may cause radio
interference, in which case the user is
required to take appropriate measures to
correct the interference.
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

5
IM 04L51B01-02EN
Handling Precautions of the GX/GP
• Use care when cleaning this instrument, especially
its plastic parts. Use a soft dry cloth. Do not use
organic solvents, such as benzene or thinner, or
other cleansers. They may cause discoloring and
deformation.
• Keep electrically charged objects away from the signal
terminals. Failure to do so may damage the GX/GP.
• Do not apply volatile chemicals to the display, panel
keys, etc. Do not allow rubber and vinyl products to
remain in contact with the GX/GP for long periods of
time. Doing so may damage the GX/GP.
• When not in use, make sure to turn off the power
switch.
• If there are any symptoms of trouble such as strange
odors or smoke coming from the GX/GP, immediately
turn off the power switch and the power supply source.
Then, contact your nearest Yokogawa dealer.
SD Memory Card Handling Precautions
• SD memory cards are delicate and should be handled
with caution.
• Yokogawa provides no warranty for damage to, or loss
of data recorded on the SD memory card, regardless
of the cause of such damage or loss. Please always
make backup copies of your data.
• Do not store or use the SD memory card in places with
static electricity, near electrically charged objects, or
where electrical noise is present. Doing so can result in
electric shock or damage.
• Do not disassemble or modify the SD memory card.
Doing so can result in damage.
• Do not physically shock, bend, or pinch the SD memory
card. Doing so can lead to malfunction.
• During reading/writing of data, do not turn OFF the
power, apply vibration or shock, or pull out the card.
Data can become corrupt or permanently lost.
• Only use Yokogawa SD memory cards. Operation
cannot be guaranteed with other brands of card.
• When inserting the SD memory card into the
instrument, make sure you orient the card correctly
(face up or down) and that you insert it securely. If not
inserted correctly, the card will not be recognized by
the instrument.
• Never touch the SD memory card with wet hands.
Doing so can lead to electric shock or malfunction.
• Never use the SD memory card if it is dusty or dirty.
Doing so can lead to electric shock or malfunction.
• The SD memory card comes formatted.
SD cards must be formatted according to the standard
established by the SD Association (https://www.sdcard.
org/home). If you want format the SD memory card,
use the instrument’s Format function. If using a PC
to perform the formatting, use the SD card formatter
software available from the above SD Association.
• You can use SD/SDHC cards (up to 32 GB) on the GX/
G P.
SD Memory Card Specifications and Characteristics
Electrical specifications Operating voltage: 2.7 V to 3.6 V (memory
operation)
Operating temperature /
humidity conditions
–25 to 85°C / 20 to 85% RH, no condensation
Storage temperature /
humidity conditions
–40 to 85°C / 5 to 95% RH, no condensation
Unit: mm
32 ± 0.1
24 ± 0.1
WP
SD
Writable
Write-protected
Checking the Package Contents
After receiving the product and opening the package,
check the items described below. If the wrong items
have been delivered, if items are missing, or if there is a
problem with the appearance of the items, contact your
nearest Yokogawa dealer.
Check that the product that you received is what you
ordered by referring to the model name and suffix code
given on the name plate on the GX/GP.
NO. (Instrument Number)
When contacting the dealer from which you purchased the
instrument, please give them the instrument number.
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

6
IM 04L51B01-02EN
GP10/GP2013
Model Suffix Code Optional
Code
Description
GP10 Paperless recorder (Portable type,
Small display)
GP20 Paperless recorder (Portable type,
Large display)
Type -1 Standard (max. no. of measurement
ch : 100)
-2 Large Memory (max. no. of
measurement ch : 500) 12
Language E English, degF, DST (summer/winter
time)10
Power supply 1 100 VAC, 240 VAC 16
2 12V DC 17
Power cord D Power cord UL/CSA standard
F Power cord VDE standard
R Power cord AS standard
Q Power cord BS standard
H Power cord GB standard
N Power cord NBR standard
W Screw terminal, power cord not
included
Options /AH Aerospace heat treatment
/AS Advanced security function
/BT Multi-batch function
/C2 RS-2321
/C3 RS-422/4851
/CG Custom display function
/D5 VGA output2
/E1 EtherNet/IP communication
(PLC communication protocol)19
/E2 WT communication14
/E3 OPC-UA server
/E4 SLMP communication (Mitsubishi
PLC)20
/FL Fail output, 1 point
/LG LOG scale
/MT Mathematical function (with report
function) 15 18
/MC Communication channel function21
/PG Program control function 22
/UH USB interface (host 2 ports)
/UC[ ]0 Analog (universal) input module
preinstalled (clamp terminal)3
/US[ ]0 Analog (universal) input module
preinstalled (M3 screw terminal)3
/CR[ ][ ] Digital output module, digital input
module preinstalled5
Models in Which I/O Modules Are Preinstalled
Model Suffix Code Optional
Code
Description
GX10 -□E/[ ][ ] Paperless recorder (panel mount type)
GX20
GP10 -□E1[ ]/[ ][ ] Paperless recorder (portable type)
GP20
Options
(analog Input)3 11
/UC10 With analog input module, 10ch (Clamp terminal)
/UC20 With analog input module, 20ch (Clamp terminal)7
/UC30 With analog input module, 30ch (Clamp terminal)8
/UC40 With analog input module, 40ch (Clamp terminal)5
/UC50 With analog input module, 50ch (Clamp terminal)5
/US10 With 10ch analog input module (M3 screw terminal)
/US20 With 20ch analog input module (M3 screw terminal)7
/US30 With 30ch analog input module (M3 screw terminal)8
/US40 With 40ch analog input module (M3 screw terminal)5
/US50 With 50ch analog input module (M3 screw terminal)5
Options
(digital I/O)4
/CR01 With digital I/O module (output: 0, input: 16)8, 9, 15
/CR10 With digital I/O module (output: 6, input: 0)8
/CR11 With digital I/O module (output: 6, input: 16)7, 8, 9, 15
/CR20 With digital I/O module (output: 12, input: 0)6
/CR21 With digital I/O module (output: 12, input: 16)6, 9, 15
/CR40 With digital I/O module (output: 24, input: 0)6
/CR41 With digital I/O module (output: 24, input: 16)6, 9, 15
MODEL and SUFFIX Codes
GX10/GX2013
Model Suffix
Code
Optional
Code
Description
GX10 Paperless recorder (Panel mount type,
Small display)
GX20 Paperless recorder (Panel mount type,
Large display)
Type -1 Standard (max. no. of measurement ch : 100)
-2 Large Memory (max. no. of measurement
ch : 500) 1112
Language E English, degF, DST (summer/winter time)10
Options /AH Aerospace heat treatment
/AS Advanced security function
/BC Black cover
/BT Multi-batch function
/C2 RS-2321
/C3 RS-422/4851
/CG Custom display function
/D5 VGA output2
/E1 EtherNet/IP communication
(PLC communication protocol)19
/E2 WT communication14
/E3 OPC-UA server
/E4 SLMP communication (Mitsubishi PLC)20
/FL Fail output, 1 point
/LG LOG scale
/MT Mathematical function (with report
function)15 18
/MC Communication channel function21
/P1 24 VDC/AC power supply4
/PG Program control function 22
/UH USB Interface (host 2 ports)
/UC[ ]0 Analog (universal) input module preinstalled
(clamp terminal)3
/US[ ]0 Analog (universal) input module preinstalled
(M3 screw terminal)3
/CR[ ][ ] Digital output module, digital input module
preinstalled5
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

7
IM 04L51B01-02EN
1 /C2 and /C3 cannot be specified together.
2 /D5 can be specified only for the GX20/GP20.
3 Only one option can be specified.
4 Only one option can be specified.
5 /UC40, /UC50, /US40, and /US50 cannot be specified for the GX10/GP10.
6 /CR20, /CR21, /CR40, and /CR41 cannot be specified for the GX10/GP10.
7 If /UC20 or /US20 is specified for the GX10/GP10, /CR11 cannot be specified.
8 If /UC30 or /US30 is specified for the GX10/GP10, /CR01, /CR10, and /CR11
cannot be specified.
9 A digital input module has M3 screw terminals.
10 The Display language is selectable from English, German, French, Russian,
Korean, Chinese, Japanese.
To confirm the current available languages, please visit the following website.
URL: www.yokogawa.com/ns/language/
11 Solid state relay type (Type Suffix Code: -U2).
12 Can be specified only for the GX20/GP20.
13 To connect an I/O base unit, you will need one I/O expansion module for the
GX/GP.
14 /MC option must be separately specified when the WT communication is
selected.
15 Optional code /MT (MATH) required if using the GX90XD’s or GX90WD’s pulse
input.
16 Selectable only when the power cord suffix code is D or F or R or Q or H or N.
17 Selectable only for the GP10 when the power cord suffix code is W.
18 The /MT option (computation) is required to perform pulse integration on
GX90XP pulse input modules.
19 If you want to write from a PLC to the GX/GP via EtherNet/IP communication, a
separate communication channel (/MC) is required.
20 If you want the GX/GP to load data from SLMP servers via SLMP
communication, a separate communication channel (/MC) is required.
21 If you want to load data from other devices into the GX/GP using Modbus client,
a communication channel (/MC) is required.
22 This is applicable only when a GX90UT PID Control Module is installed.
I/O Base Unit (Expandable I/O) 1
Model Suffix Code Description
GX60 I/O base unit
Type -EX I/O Expansion
Area N General
Power supply 1 100 VAC, 240 VAC
Power cord D Power cord UL/CSA standard
F Power cord VDE standard
R Power cord AS standard
Q Power cord BS standard
H Power cord GB standard
N Power cord NBR standard
WScrew terminal, power cord not included 2
1 Include GX90EX (Expansion module), Stopper (antiskid rubber)
2 Intended use for panel or rack mounting only.
I/O Expansion Module (Expansion Module)
Model Suffix Code Description
GX90EX I/O Expansion Module
Port -02 2 ports
Type -TP1 Twisted pair cable
- N Always N
Area -N General
I/O Modules
GX90XA
Model Suffix Code Description
GX90XA Analog Input Module
Channels
-04 4 channels (Type -H0 only)
-06 6 channels (Type -R1 only)
-10 10 channels (Type -C1, -L1, -U2, -T1 )
Type
-C1 Current, Scanner type
(isolated between channels)
-L1
DCV/TC/DI (400 VAC, 1 min),
Scanner type
(isolated between channels)
-U2 Universal, Solid state relay scanner
type (3-wire RTD b-terminal common)
-T1
DCV/TC/DI, Electromagnetic relay
scanner type (Isolated between
channels)
-H0 High-speed universal, individual A/D
type (isolated between channels)
-R1 4-wire RTD/resistance, scanner type
(isolated between channels)
- N Always N
Terminal type -3 Screw terminal (M3)
-C Clamp terminal
Area N General
GX90XD
Model Suffix Code Description
GX90XD Digital Input Module 1
Channels -16 16 channels
Type -11 Open collector/Non-voltage, contact
(shared common), Rated 5 VDC
- N Always N
Terminal type -3 Screw terminal (M3)
-C Clamp terminal
Area N General
1 Optional code /MT (MATH) required if using the pulse input.
GX90YD
Model Suffix Code Description
GX90YD Digital Output Module
Channels -06 6 channels
Type -11 Relay, SPDT(NO-C-NC)
- N Always N
Terminal type -3 Screw terminal (M3)
Area N General
GX90WD
Model Suffix Code Description
GX90WD Digital Input/Output Module 1
Channels -0806 Input 8 channels, Output 6 channels
Type -01
Open collector/non-voltage contact
(shared common), rated 5 VDC;
Relay, SPDT (NO-C-NC)
- N Always N
Terminal type -3 Screw terminal (M3)
Area N General
1 Optional code /MT (MATH) required if using the pulse input.
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

8
IM 04L51B01-02EN
Standard Accessories
The instrument is shipped with the following accessories.
Make sure that all accessories are present and
undamaged.
7
8
1 2 3 4 5
6
No. Name Part Number/Model Qty. Notes
1 Mounting
bracket
B8740DY 2 GX10/GX20 only
2 SD memory
card
773001 1 1GB
3 Dummy cover B8740CZ For empty slots
4 Tag plate B8740FE 1 GX20
B8740ME 1 GP20
B8741FE 1 GX10
B8741ME GP10
5 Sheet B8740FF 1 GX20
B8740MF 1 GP20
B8741FF 1 GX10
B8741MF 1 GP10
6 Stylus B8740BZ 1
7 Power cord A1006WD 1 D: Power cord UL,
CSA st’d 1
A1009WD 1 F: Power cord VDE
st’d 1
A1024WD 1 R: Power cord AS
st’d 1
A1054WD 1 Q: Power cord BS
st’d 1
A1064WD 1 H: Power cord GB
st’d 1
A1088WD 1 N: Power cord NBR
st'd 1
8 Manual IM 04L51B01-02EN 1 First Step Guide (This
manual)
IM 04L61B01-11EN 1 Regarding the
Downloading and
Installing for the
Software, Manuals
and Labels/About
the Usage of Open
Source Software
1 Except GP10 power supply suffix code: 2
Optional Accessories (Sold separately)
Name Part Number/
Model
Minimum.
Q’ty
Notes
Mounting bracket B8740DY 2 GX10/GX20 only
SD memory card 773001 1 1GB
Stylus B8740BZ 1
Shunt resistor
(for M3 screw terminal)
415940 1 250 Ω ± 0.1%
415941 1 100 Ω ± 0.1%
415942 1 10 Ω ± 0.1%
Shunt resistor
(for clamp terminal)
438920 1 250 Ω ± 0.1%
438921 1 100 Ω ± 0.1%
438922 1 10 Ω ± 0.1%
Dummy cover B8740CZ 1 For module slot
GX90XP
Model Suffix Code Description
GX90XP Pulse Input Module 1
Channels -10 10 channels
Type -11
DC voltage/Open collector/Non-
voltage, contact (shared common),
Rated 5 VDC
- N Always N
Terminal type -3 Screw terminal (M3)
-C Clamp terminal
Area N General
1 The /MT option (computation) is required to perform pulse integration.
GX90YA
Model Suffix Code Description
GX90YA Analog Output Module
Channels -04 4 channels
Type -C1 Current output (isolated between
channels)
- N Always N
Terminal type -3 Screw terminal (M3)
-C Clamp terminal
Area N General
GX90UT
Model Suffix Code Description
GX90UT PID Control Module
Number
of loops -02 2 loops
Function -11 DI 8 points, DO 8 points
- N Always N
Terminal type -3 Screw terminal (M3)
Area N General
■ Customized Product
For customized product, the product is identified by the
option code of /S# (where ‘#’ is a number).
Contact your supplier in case your instrument has option
/S#, and you are not in the possession of IM [Model code]-
-S# (where [Model code] means, for example, GX90XA).
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

9
IM 04L51B01-02EN
GX/GP Style Number, Release Number, and
Firmware Version Number
Style number: The GX/GP hardware ID number. This
number is written on the name plate (H
column).
Release number: The GX/GP firmware ID number. This
number is written on the name plate
(S column). This number matches with
the integer part of the firmware version
number.
Example: If the firmware version number is 1.01, the
release number is 1.
Firmware version number:
This number appears on the system
information screen of the GX/GP.
To view the number, see section
2.3, “Displaying Various Types of
Information” in the User’s Manual, IM
04L51B01-01EN.
Conventions Used in This Manual
• This manual covers information regarding GX/GPs
whose display language is English.
• For details on the language setting, see the Paperless
Recorder User’s Manual, IM04L51B01-01EN.
Unit
K: Denotes 1024. Example: 768K (file size)
k: Denotes 1000.
The notes and cautions in this manual are indicated using
the following symbols.
Improper handling or use can lead to injury to the user or
damage to the instrument. This symbol appears on the
instrument to indicate that the user must refer to the user’s
manual for special instructions. The same symbol appears
in the corresponding place in the user’s manual to identify
those instructions. In the manual, the symbol is used in
conjunction with the word “WARNING” or “CAUTION.”
WARNING
Calls attention to actions or conditions that could cause
serious or fatal injury to the user, and precautions that can
be taken to prevent such occurrences.
CAUTION
Calls attentions to actions or conditions that could cause
light injury to the user or damage to the instrument or
user’s data, and precautions that can be taken to prevent
such occurrences.
Note
Calls attention to information that is important for proper
operation of the instrument.
Module Notation
When necessary, the following notations are used to
distinguish the GX90XA analog input modules by type.
Type Suffix Code Notation
-U2 Universal
-C1 Current (mA)
-L1 Low withstand voltage relay
-T1 Electromagnetic relay
-H0 High-speed universal or High speed AI
-R1 4-wire RTD/resistance
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

10 IM 04L51B01-02EN
Protection of Environment
Control of Pollution Caused by the Product
This is an explanation for the product based on “Control of pollution caused by Electronic Information Products” in the
People’s Republic of China.
产品中有毒有害物质或元素的名称及含量
部件名称
有毒有害物质或元素
铅(Pb) 汞(Hg) 镉(Cd) 六价铬
(Cr6+)
多溴联苯
(PBB)
多溴二苯醚
(PBDB)
印制电路板 N/A N/A N/A
内部接线材料 N/A N/A N/A
外壳/ 机箱 塑料 N/A N/A N/A
金属 N/A N/A N/A
I/O 模块外壳 塑料 N/A N/A N/A
电源 N/A N/A N/A
正面边框 N/A N/A N/A
显示器 (LCD) N/A N/A N/A
标准附件/ 可选附件 安装支架 N/A N/A N/A
电源线(GP10/GP20/GX60 (
的插口型))
N/A N/A N/A
SD 存储卡 N/A N/A N/A
分流电阻 N/A N/A N/A
:表示该部件的所有均质材料中的有毒有害物质或元素的含量均低于GB/T 26572 标准所规定的限量要求。
N/A:表示该部件中至少有一种均质材料中的有毒有害物质或元素的含量超过GB/T 26572 标准所规定的限量要求。
本产品的部分部件包含RoHS指令中的限用物质,但是其使用方法不受该指令限制。
Some parts of this product include the restricted substances of RoHS Directive, but their applications are under the exemption of the directive.
该标志为环境保护使用期限,根据SJ/T11364,适用于在中国(台湾、香港、澳门除外)销售的电子电气产
品。只要遵守该产品的安全及使用注意事项,从产品生产之日起至该标志所示年限内,不会因为产品中的
有害物质外泄或突变而导致环境污染或对人身财产产生重大影响。
注释) 该标志所示年限为“环境保护使用期限”,并非产品的保质期。另外,关于更换部件的推荐更换周
期,请参阅使用说明书。
Waste Electrical and Electronic Equipment (WEEE), Directive
This is an explanation of how to dispose of this product based on Waste Electrical and Electronic
Equipment (WEEE), Directive. This directive is only valid in the EU.
• Marking
This product complies with the WEEE Directive marking requirement. This marking indicates that you
must not discard this electrical/electronic product in domestic household waste.
• Product Category
With reference to the equipment types in the WEEE directive, this product is classified as a “Monitoring
and Control instrumentation” product.
Do not dispose in domestic household waste.
When disposing products in the EU, contact your local Yokogawa Europe B.V. office.
How to Dispose the Batteries
This is an explanation about the EU Battery Directive This directive is only valid in the EU.
Batteries are included in this product. Batteries incorporated into this product cannot be removed by
yourself. Dispose them together with this product. When you dispose this product in the EU, contact your
local Yokogawa Europe B.V.office. Do not dispose them as domestic household waste.
Battery type: Lithium battery
Notice: The symbol (see above) means they shall be sorted out and collected as ordained in ANNEX II in
DIRECTIVE 2006/66/EC.
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

11
IM 04L51B01-02EN
Functional Overview
Overview
The GX/GP is a paperless recorder that can display
measured data in real time on its touch screen and save
the data in an SD memory card.
A variety of
signal inputs
GX/GP configuration
and real-time monitoring
on a Web browser
Displaying data on
Universal Viewer
GX/GP Ethernet
Redundant measured data
on internal memory and external media
SD memory card
A Variety of Source Signals
The GX/GP can connect to DC voltage, TC, RTD, ON/
OFF, DC current (mA) and pulse inputs and measure
temperature, flow rate, and other parameters. The GX/GP
acquires data by sampling input signals at the set scan
interval. The shortest scan interval is 1 ms (High-speed AI
module). Up to four alarm conditions can be specified on
each measurement channel.
Expandable Module Construction
The I/O section is modular, so you can configure your
system according to the input types and number of
measurement points.
Modules
Model Name Channels
GX90XA Analog input module 4/6/10
GX90XD Digital input module 16
GX90YD Digital output module 6
GX90WD Digital Input/Output Module Input : 8 ,
Output : 6
GX90XP Pulse Input Module 10
GX90YA Analog output module 4
GX90UT PID Control Module 26
• Up to 10 modules can be installed in the GX20/GP20.
• Up to 3 modules can be installed in the GX10/GP10.
• Different modules can coexist.
* Up to nine modules for the GX20/GP20 and two
modules for the GX10/GP10 when an GX60 is
connected.
Detachable module
terminal block
Maintenance is easy!
GX60 Connection and Multichannel
Measurement
An GX60 I/O can be connected to the GX20/GP20 to
measure up to 450 channels. On the standard type,
you can connect the GX60 to allocate input sections at
different locations.
GX/GP
GX60
•
•
•
Max6
GX90EX
Rear
GX/GP configuration
Item GX/GP
Standard Type Large Memory Type
Maximum number of
connectable GX60
6 6
Maximum number of
I/O modules (main
unit + GX60)
10 145 2
Maximum number of
I/O channels
100 500
1 2 on the rear of the GX10/GP10, 9 on the rear of the
GX20/GP20.
2 9 on the rear of the GX20/GP20.
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

12
IM 04L51B01-02EN
High-speed Measurement, Dual
Interval Measurement (Measurement
mode)
The GX/GP has measurement modes to allow high-speed
measurement and simultaneous measurement of slow
and fast signals.
In high-speed measurement, a high-speed AI module
can be installed to achieve measurement at the shortest
interval of 1 ms.
In dual interval measurement, measurement can be
performed by two measurement groups with different scan
intervals.
Various measurements can be performed by changing the
measurement mode according to the measurement target
and measurement conditions.
Loop Control and Program Control
Function (/PG Option)
By installing a PID Control Module (GX90UT), you can
perform PID control of up to 20 loops (up to 6 loops for
the GX10/GP10). In addition to control loop monitoring
and the control group screen for convenient operation,
adjustment using the tuning screen is available.
Adding the /PG option to the GX/GP main unit allows
99 patterns and 99 segments of program patterns to be
stored in the main unit. Further, 32 time events can be set.
Data Storage
There are two ways to store data. One way is to record
measured data at all times (display data and event data).
The other way is to record only when events, such as
alarms, occur (event data). Measured data is saved to
the internal memory at the specified interval. Data in
the internal memory can be saved to the SD memory
card automatically or manually. Measured data can
be transferred automatically to an FTP server over an
Ethernet connection.
GX/GP
Signal input
Ethernet
Auto data transfer to FTP server
SD Memory
card
FTP server
Internal memory
A Variety of Display Functions
Measured data can be displayed in groups as trend
waveforms, values, and bar graphs. There is also an
overview display that you can monitor all channels on a
single screen.
Trend Digital Bar graph
Overview Multi panel
Custom Display (Option, /CG)
You can control and monitor on a custom display
consisting of digital, trend, bar graph, and other
components and images can that are laid out freely.
Custom displays are created using DAQStudio (DXA170),
a software application sold separately.
Displays that you create are loaded into the GX/GP from
DAQStudio or from an external storage medium.
Custom Display
Functional Overview
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

13
IM 04L51B01-02EN
Touch Screen
The GX/GP touch screen enables intuitive operation. You
can tap the icons of setup and operation items as well as
scroll and zoom in on and out of waveforms by directly
touching the screen. In addition, when you are working
on-site, you can operate the GX/GP with your gloves on.
Touch Operations
Tap
Touch the screen with a pen or finger.
Drag
Drag
Touch the screen with a pen or finger
and move.
Drag
Flick
Wipe a pen or finger across
the screen.
Functional Overview
Pinch apart/together
Touch the screen with two fingers
and move them apart or together.
Freehand Messages
You can use the touch pen or your finger to write text and
draw marks freely in the waveform area. The messages
that you write can easily be displayed from information
displays such as the message summary and memory
summary.
Versatile Network Functions and
Software
The Ethernet interface enables you to monitor the GX/
GP from a Web browser. E-mails can be sent through this
interface when alarms and other events occur.
In addition, you can use the Modbus protocol to read
data from other devices on the network and display it.
As for the software, Universal Viewer can be used to
view measured data and convert the data into other data
formats.
Ethernet
Internet Explorer
Seamless remote monitoring
on a Web browser
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

14 IM 04L51B01-02EN
Other Functions
Math function
(/MT option)
Expressions can be assigned to
math channels to perform various
computations.
Logic math can output calculated
results as 0 or 1 to DOs or internal
switches. Computation is performed
regardless of the math start/stop
condition.
FAIL output
(/FL option)
This function transmits alarms when
the GX/GP fails.
Security function You can allow only registered users
to use the GX/GP. In addition, certain
operations can be prohibited.
Remote control This function executes specified
operations by combining input modules
and the event action function.
Advanced
security function
(/AS option)
A security function that complies with
US FDA 21CFR Part11. Electronic
signatures can be added to measured
data.
EtherNet/IP
communication (/
E1 option)
This function is equipped with a server
function that enables communication
with EtherNet/IP devices.
WT
communication
(/E2 option)
This function acquires measured and
calculated data from a power meter
and displays and records it along with
the measured values of the GX/GP.
LOG scale (/LG
option)
This function measures logarithmic
voltage that has been converted from a
physical value, scales the voltage, and
displays the resultant data.
Aerospace heat
treatment (/AH
option)
Supports aerospace heat treatment
measurements and NADCAP
AMS2750E compliant recording and
reporting.
Manage user-defined schedules for
periodical execution.
Multi batch (/BT
option)
Start and stop recording separately for
each batch and create data files for
each batch.
OPC-UA server
(/E3 option)
Equipped with an OPC-UA server
function. GX/GP measurement data
can be retrieved directly from a host
system, such as SCADA and MES.
SLMP
communication (/
E4 option)
Equipped with a client function for the
MC protocol. Connection to Mitsubishi
Electric PLCs can be established
easily.
Functional Overview
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

15
IM 04L51B01-02EN
System Configuration
You can configure a GX/GP system as shown below.
PC
PC
Recorder
Network
printer
Temperature
Controller
Monitor*
Ethernet
USB port*
Alarm output
Serial communication*
RS-232, RS-422/485
FAIL/status output*
keyboard
Mouse
SD memory card
Bar code reader
(GX20/GP20 only)
USB memory
* Option
Manual DO output
Power meter
(WT)
Analog output
DO out
DI input
Alarm out
Control input
DI
RTD TC/DCV
Control output
A
mA Pulse DC loop power
supply
Digital input/output
Signal output
Signal input
DI
RTD TC/DCV mA
•
•
•
GX60
Max 6 unit
Pulse
Remote input GX10
GP20
GP10
• Download PC software
• Download user’s manuals
Web site
GX20
A
3-wire/4-wire
Functional Overview
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550

16 IM 04L51B01-02EN
Component Names
GX20/GX10
RS-232 terminal
Power inlet (GP10/GP20)
Serial port (/C2 option)
Shows the trend display and other
displays and the setup screen
Starts and stops recording
Press this once to show a menu
for accessing various screens.
USB2.0 compliant. Connect a USB
memory device, mouse, keyboard, etc.
SD memory card (up to 32 GB)
Format: FAT32 or FAT16
A 1 GB card is included.
Use an off-the-shelf door lock key.
GX20 front panel GX10 front panel
GX10 rear panel
GX20 rear panel
LCD
MENU key
MENU key
Stylus pen (touch pen)
Power switch
SD memory card slot
USB port (/UH option)
USB 2.0 compliant. Connect a USB memory device, mouse, keyboard, etc.
USB port (/UH option)
Connect I/O signals.
GX10, GP10: 3slots (0 to 2)
GX20, GP20: 10 slots (0 to 9)
RS-422/485 terminal
I/O module
Power supply terminal and protective
ground terminal (GX10/GX20)
Serial port (/C3 option)
10BASE-T/100BASE-TX port
Ethernet port
FAIL output terminal (/FL option)
Connects to an external monitor
VGA output connector (/D5 option)
Front door lock
mechanism
I/O module slot
START/STOP key
Front door
A front door is locked/unlocked
by a slide at the bottom.
Lock
Alarms are indicated with a red
LED.
Power Specialties, Inc. | www.powerspecialties.com | (816) 353-6550
This manual suits for next models
16
Table of contents
Other YOKOGAWA Voice Recorder manuals

YOKOGAWA
YOKOGAWA DR130 User manual

YOKOGAWA
YOKOGAWA SL1400 ScopeCorder LITE User manual

YOKOGAWA
YOKOGAWA SMARTDAC+ GX10 User manual

YOKOGAWA
YOKOGAWA FX1000 User manual

YOKOGAWA
YOKOGAWA MuR10000 User manual

YOKOGAWA
YOKOGAWA SMARTDAC PLUS GX20W User manual

YOKOGAWA
YOKOGAWA Daqstation DX1000N User manual

YOKOGAWA
YOKOGAWA SMARTDAC+ GX10 User manual

YOKOGAWA
YOKOGAWA SMARTDAC+ GX10 User manual

YOKOGAWA
YOKOGAWA DR231 User manual