Z-Wave.Me ZME_05459 User manual

ZME_05459
Wall Blind Control Set for Busch-Jaeger DURO 2000
Firmware Version :1.8
Quick Start
A This device is a Z-Wave Actuator. Triple click one of the buttons on the device will include the device. A green blinking of LED will
indicate successful inclusion. The device is excluded by triple click to one of the buttons.
Please refer to the chapters below for detailed information about all aspects of the products usage.
What is Z-Wave?
This device is equipped with wireless communication complying to the Z-Wave standard. Z-Wave is the international standard for wireless
communication in smart homes and buildings. It is using the frequency of 868.42 MHz to realize a very stable and secure communication.
Each message is reconrmed (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed
network) in case the receiver is not in direct wireless range of the transmitter.
Z-Wave differentiates between Controllers and Slaves. Slaves are either sensors (S) transmitting metered or measured data or actuators (A)
capable to execute an action. Controllers are either static mains powered controllers (C) also referred to as gateways or mobile battery
operated remote controls (R). This results in a number of possible communication patterns within a Z-Wave network that are partly or
completely supported by a specic device.
1. Controllers control actuators
2. Actuators report change of status back to controller
3. Sensors report change of status of measured values to controller
4. Sensors directly control actuators
5. Actuators control other actuators
6. Remote controls send signals to static controllers to trigger scenes or other actions
7. Remote controls control other actuators.
There are two different role a controller can have. There is always one single primary controller that is
managing the network and including/excluding devices. The controller may have other functions - like control
buttons - as well. All other controllers don't manage the network itself but can control other devices. They are called secondary controllers. The image also shows that
its not possible to operate a sensor just from a remote control. Sensors only communicate with static controllers.
Product description
The Z-Wave.Me Flush Mountable Motor Control is a wireless actuator able to control 230 V powered motors for blinds and jalousies. The
device is delivered as a complete set with ush mountable insert, paddle and mounting frame compatible to the design of the switching
series DURO 2000 SI in color pearl white from Busch Jaeger. The paddle of the device is used to control the device itself but can also be
congured to activate scenes in a central IP gateway or controller. The status of the motor control is indicated on a dual color LED for test
purposes and every status change is - if congured - reported to a central IP gateway or controller. The function of the local paddle can be
congured as detached from the local operation. In this local control different devices are controlled by Z-Wave while the local actuator is
controlled by other devices using Z-Wave. This device is designed for a 3 wire system and needs a neutral wire in the wall box.
Before Device is installed
Please read carefully the enclosed user manual before installation of the radio-actuator, in order to ensure an error-free functioning.
ATTENTION: only authorized technicians under consideration of the country-specic installation guidelines/norms may do works with 230 Volt
mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

The product is permitted only for proper use as specied in the user manual. Any kind of guarantee claim has to be forfeited if changes,
modications or painting are undertaken. The product must be checked for damages immediately after unpacking. In the case of damages, the
product must not be operated in any case. If a danger-free operation of the equipment cannot be assured, the voltage supply has to be
interrupted immediately and the equipment has to be protected from unintended operation.
Installation Guidelines
The insert is designed to t into standard circular European wall boxes with 60 mm diameter. The insert combined with the mounting plate
can be screwed in top of the wall box using the two screws delivered with the device. The mounting frame is then attached to the mounting
plate and the switch is completed by pushing the switching paddle into the mounting frame. Mind the arrow on the inserts top side showing
the mounting direction of the insert. It is also possible to mount the insert without any local operation behind a cover or inside a lamp. The
mounting plate, frame and the switching paddle become useless in such a scenario.
The schematics below shows how to wire the actuator. The hot wired from the mains distribution panel is connected to the inserts contacts L.
The contact S is the switched contact and need to be connected to the cable to the load. The cable from the load is connected to neutral N. If
there are both neutral and hot wire in the wall box the neutral from the mains panel and the neutral to the lamp need to be connected. It is
not harmful if the two connections L and S are mismatched on the actuator.
A fuse protects the electronics of the actuator. The fuse is accessible on the top side of the device. Inside the plug there is the working fuse
plus a spare fuse.
CALIBRATION:
The device is able to position a blind on a desired percentage position (50 percent open) when controlled wirelessly. To allow this kind of
positioning the total travel times of the motor in opening and closing direction must be determined using a simple clock. The two values need
to be congured as conguration parameter 4 and 5. Be aware that the percentage settings will never be very accurate because the blind
control actuator lacks a sensor to determine the correct position.
Behavior within the Z-Wave network
I On factory default the device does not belong to any Z-Wave network. The device needs to join an existing wireless network to
communicate with the devices of this network. This process is called Inclusion. Devices can also leave a network. This process is called
Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller will be turned into exclusion
respective inclusion mode. Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode.

Only if the primary controller is in inclusion or exclusion mode, this device can join or leave the network. Leaving the network - i.e. being
excluded - sets the device back to factory default.
If the device already belongs to a network, follow the exclusion process before including it in your network. Otherwise inclusion of this device
will fail. If the controller being included was a primary controller, it has to be reset rst.
Blinking red/green LED indicates that the device is in factory reset state. Once the controller is turned into inclusion mode triple click one of
the buttons on the device will include the device. A green blinking of LED will indicate successful inclusion that will be turned off shortly
afterwards. The device is excluded by triple click to one of the buttons when the controller is in exclusion mode.
Operating the device
The actuator is operated by the local switching paddles or wirelessly using Z-Wave commands (communication patterns 1, 4, 5 and 7). If the
insert is mounted correctly pushing the upper part of the paddle will turn the blind into the open position; pushing the lower part of the
paddle will turn the blind into the close position. Hitting the paddle during operation (moving motor) will stop the operation for safety
reasons. Keeping the paddle pushed moved the motor until the desired position is reached. Releasing the paddle will stop the motor.
The device is also able to report status changes to a controller (communication pattern 2) and to remotely operate other devices
(communication pattern 5) by sending wireless Z-Wave commands. In case the remote device is a switch as well the remote operation is
similar to the local operation by pushing upper to lower part of the switching paddle. However the device can also be congured with
conguration parameter 13 and 14 to operate remote dimmers. To dim a remote device the paddle needs to be pushed and hold (upper part to
dim up, lower part to dim down). Its furthermore possible to assign remote operation functions to the double click of the paddles.
Child Protection
The device can be turn into a child protection mode. In this mode all local operation is disabled.
The child protection mode MUST be turned on wirelessly. However in protected by sequence mode it is possible to unlock the device for local
operation with a triple click. The unlock state will last for 5 seconds.
LED Control
Red and green blinking continuously: Device is not included in a Z-Wave network
Red lights up for 3 seconds: Device was not included/excluded after being put into learn mode by triple press of up/down button
Green lights up for 3 seconds: The inclusion/exclusion was successful or new association was saved successfully
Green or no light: depending on settings of conguration parameter for LED control
Associations
A Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called
association
.
In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These
lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event
happens all devices stored in the respective association group will receive a common wireless command.
Association Groups:
1 Single press and hold of up/down buttons (max. nodes in group:14)
2 Double press and press-hold of up/down buttons (max. nodes in group:14)
3 Send Reports on blind state change (max. nodes in group:14)
Conguration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain conguration can adapt the function better to user
needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow to congure signed values. In order to set values in the range 128 … 255 the value sent in the
application shall be the desired value minus 256. For example: to set a parameter to 200 it may be needed to set a value of 200 minus 256 =
minus 56. In case of two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
LED mode (Parameter Number1,Parameter Size1)

Set LED indication mode
Value Description
0 Disabled
1 Show working state
2 Show idle state
4 Show if not closed
3 Operated by Indicator Command Class (Default)
Automatically open or close after (Parameter Number2,Parameter Size2)
If not zero, automatically open or close blind after a user dened time
Value Description
0 Disabled (Default)
1 — 65535 sec
What to do on RF close command (Parameter Number3,Parameter Size1)
Denes how to interpret RF Off command. Can be used in conjunction with Auto Close function: Ignore - to open the door by motion detectors
and close it back after some amount of time: in case of multiple motion detectors each would try to open that would break logics; Open - to
open on both On and Off paddle press on the remote and close after some amount of time. Button close click will still work (if button
operations are not disabled). Note that Dim Down command will still begin close motion.
Value Description
0 Close (Default)
1 Ignore
2 Open
3 Open if closed else close
Full close time (Parameter Number4,Parameter Size1)
Time to go from opened to closed state. Used to estimate the current level. Note that in Permanent motion mode the reported value would a
be Closed or Opened, while all Basic and Multilevel Set values (1-99, 255) would Open except 0 value that would Close.
Value Description
0 Keep in permanent motion
1 — 255 seconds (Default60)
Full open time (Parameter Number5,Parameter Size1)
Time to go from closed to open state. This value may differ from Full close time for some blinds due to gravity. Used to estimate the current
level. Note that in Permanent motion mode the reported value would a be Closed or Opened, while all Basic and Multilevel Set values (1-99,
255) would Open except 0 value that would Close.
Value Description
0 Keep in permanent motion
1 — 255 seconds (Default60)
Node Id of the blocking device (Parameter Number6,Parameter Size1)
Id of the device which commands would be interpreted not as Open/Close, but as block/unblock. Usefull with door opening detector: if the
door is open, block the blind not to break shades while they move.

Value Description
0 Disabled (Default)
1 — 232 Node Id
On which command from blocking node to enable the protection (Parameter Number7,Parameter Size1)
Denes which command from blocking device to interpret as closed door and hence, unprotected.
Value Description
0 on On (Default)
1 on Off
Stop or Revert if opposite button is pressed (Parameter Number8,Parameter Size1)
Denes behaviour on open press while closing and vice versa. To allow Stop behavior when switched by remote, use Stop by Basic
Value Description
0 Stop (by buttons and Binary) (Default)
2 Stop (by buttons, Binary and Basic)
1 Revert
Invert open and close relays (Parameter Number9,Parameter Size1)
Allow exchanging open and close relays if blind control is wired to the motor incorrectly
Value Description
0 No (Default)
1 Yes
Typical click timeout (Parameter Number10,Parameter Size1)
Typical time used to differentiate click, hold, double and triple clicks
Value Description
1 — 100 in 10ms units (Default50)
Invert buttons (Parameter Number11,Parameter Size1)
Value Description
0 No (Default)
1 Yes
Switch by buttons (Parameter Number12,Parameter Size1)
If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode
buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF
commands only.
Value Description
0 No
1 By single press and hold (Default)
2 By double press and press-hold
Action on button single press or hold (Parameter Number13,Parameter Size1)

Denes which command should be sent on button single press or hold. Basic and Scene Activation commands are sent to Association group.
Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast.
Value Description
0 Disabled
4 Switch On/Off and Dim (send Basic Set and Switch Multilevel) (Default)
1 Switch On/Off only (send Basic Set)
2 Switch All
3 Send Scenes
5 Send Precongured Scenes
Action on button double press or hold (Parameter Number14,Parameter Size1)
Denes which command should be sent on button double press or press-hold. Basic and Scene Activation commands are sent to Association
group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast. If not disabled, the device
will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands
Value Description
0 Disabled (Default)
4 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
1 Switch On/Off only (send Basic Set)
2 Switch All
3 Send Scenes
5 Send Precongured Scenes
Send the following Switch All commands (Parameter Number15,Parameter Size1)
Value Description
1 Switch off only (Default)
2 Switch on only
255 Switch all on and off
What to do on button Down press (Parameter Number16,Parameter Size1)
Denes how to interpret button Down press. Depends on "Switch by buttons" parameter. If not Disabled this parameter will affect the action
selected by the latter parameter. Can be used in conjunction with Auto Off function.
Value Description
0 Close (Default)
1 Open if closed else close
2 Open
Action on Auto open or close function (Parameter Number17,Parameter Size1)
Value Description
0 Close blinds (Default)
1 Open blinds
Command Classes
Supported Command Classes

Basic (version 1)
Binary Switch (version 1)
Multilevel Switch (version 3)
Version (version 1)
Indicator (version 1)
All Switch (version 1)
Multi Channel Association (version 2)
Conguration (version 1)
Manufacturer Specic (version 1)
Protection (version 1)
Node Naming and Location (version 1)
Association (version 2)
Multi Channel (version 2)
Scene Activation (version 1)
Scene Actuator Conguration (version 1)
Scene Controller Conguration (version 1)
Controlled Command Classes
Basic (version 1)
Multilevel Switch (version 3)
All Switch (version 1)
Multi Channel (version 2)
Scene Activation (version 1)
Technical Data
Power Supply 230V ~50-60 Hz
Attachable Loads Motors up to 1800 W
Fuse Type: T 1.25 A H (Load 1.25 Ampere, high shutdown capacity), D: 5 mm, L: 20 mm
IP Rating IP 20
Frequency 868.42 MHz (SRD Band)
Wireless Range up to 100 m outside, on average up to 20 m inside buildings
Explorer Frame Support Yes
SDK 4.54.01
Device Type Slave with routing capabilities
Generic Device Class Multilevel Switch
Specic Device Class Motor Control Class C
Routing Yes
FLiRS No
Firmware Version 1.8
Explanation of Z-Wave specic terms

Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways, Remote Controls or
battery operated wall controllers.
Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a
Z-Wave network.
Inclusion — is the process of bringing new Z-Wave devices into a network.
Exclusion — is the process of removing Z-Wave devices from the network.
Association — is a control relationship between a controlling device and a controlled device.
Wakeup Notication — is a special wireless message issued by a Z-Wave device to annonces that is is able to communicate.
Node Information Frame — is a special wireless message issued by a Z_Wave device to announce its capabilities and functions.
Disposal Guidelines
The product does not contain hazardous chemicals.
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for
information regarding the collection systems available. If electrical appliances are disposed of in landlls or dumps, hazardous substances can
leak into the groundwater and get into the food chain, damaging your health and well-being.
xxx
Table of contents
Other Z-Wave.Me Controllers manuals
Popular Controllers manuals by other brands

Johnson Controls
Johnson Controls FX-PCV1615 installation instructions

Peter electronic
Peter electronic VersiStart i II Commissioning instructions

Satel
Satel ACU-250 Installer manual

Atmel
Atmel WINC1500 Getting started guide

Vescent
Vescent SLICE-QTC quick start guide

Unitronics
Unitronics Samba SM70-J-TA22 installation guide

Woodward
Woodward TecJet 52 Installation and operation manual

NOVABO
NOVABO SQUEALER-GSM manual

Deep Sea Electronics Plc
Deep Sea Electronics Plc 5320 Installation instructions and instructions for use

Parker
Parker Sporlan S3C manual

Hanbay
Hanbay MC A 8.09 Series user manual

ComfortClick
ComfortClick Jigsaw manual