Zamel ROP-03 User manual

www.ledix.pl
2-channel radio
ush receiver
ROP-03
Zamel Sp. z o.o.
PL 43-200 Pszczyna, ul. Zielona 27, Poland
tel: +48 32 449 15 00, fax: +48 32 449 15 02
10÷14 V DC / 0,7 W; IP20
weight: 36 g
Declaration of Conformity is on www.ledix.pl
2-channel radio ush receiver
ROP-03
The symbol means selective collecting of electrical and electronic equipment.
It is forbidden to put the used equipment together with other waste.
ROP-03 receiver is designed to carry out simple control functions in the low-voltage instal-
lations from 10 ÷ 14 V DC. In connection with EXTA FREE system transmitters it enables the
realisation of the switch on/switch o function, the monostable mode, the bistable and
time modes. The receiver is recommended for use with LED diode lighting.
Characteristic features:
• cooperation with wireless EXTA FREE system transmitters,
• independent control of up to two receivers in the following modes: switch on/switch off,
monostable, bistable, time,
• 2 relay potential free outputs (NO) with a maximum capacity of 5 A for 250 V AC,
• wide operation range (up to 230 m outdoors),
• small dimensions - suitable for mounting in a typical Ø60 junction box,
• low power consumption in the standby mode (0.15 W) - the receiver is used to a continu-
ous operation.
Mounting in a Ø60
junction box
Mounting
indoor only
Co-operation
with EXTA FREE
transmitters
ROP-03 ENG Ver. 01
SCAN
the technical
data
10
÷
14
V
DC
CET Lighting Sp. z o.o. declares that the equipment complies with the principal requirements
and other applicable rules of the RTTE Directive.

230 V AC 14 V DC
750 W 250 W 500 W 375 W
CAUTION !The device is designed for single-phase installation and must be installed
in accordance with standards valid in a particular country. Installation, connection
and control should be carried out by a qualied electrician sta, who act in accord-
ance with the service manual and the device functions.
1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch- discon-
nector combined to the proper circuit.
2. Check if there is no voltage on connection cables by means of a special measure equip-
ment.
3. Connect the power supply to 230 V AC.
4. 4. Connect the output cables with appropriate receiver’s cables in accordance with the
connection diagram.
5. Mount the controller in the Ø60 junction box.
6. Switch on the power supply from the mains.
7. Add selected transmitters to the receiver (description in the TRANSMITTERS’ PRO-
GRAMMING section) and check if they work properly.
ROP-03 receiver is designed to carry out simple control functions in the low-voltage instal-
lations from 10 ÷ 14 V DC. This device in connection with any wireless EXTA FREE (www.
extafree.pl)system transmitter enables the realisation of the switch on / switch o func-
tion, the monostable mode, the bistable and time modes. The receiver is recommended
for use with LED diode lighting. ROP-03 device has two potential free (NO) relay outputs
with a maximum capacity of 5 A for 250 V AC. Small dimensions of the casing allow for
a direct mounting of the receiver in the Ø60 mm junction box. The product belongs to
the ECOLINE group and is characterised by low power consumption. The features of the
controller:
• cooperation with wireless EXTA FREE system transmitters,
• realisation of the control function in low voltage installations including LED diode lighting,
• two output relays (dry contacts),
• the possibility of independent control of two circuits,
• multiplicity of operation modes: switch on / switch o, monostable, bistable, time,
• wide operation range (up to 230 m outdoors),
• a possibility to increase the operation range by using RTN-01 retransmitter,
• operation is optically signalled,
• low power consumption in the standby mode (0.15 W) - a device designed for continu-
ous operation.
TECHNICAL DATA
MOUNTING
DESCRIPTION
DIAGRAM
APPEARANCE
Nominal supply voltage: 10 ÷ 14 V DC
Nominal power consumption: 0,7 W
Number of channels: 2
Maximum current in the channel: 5 A / 250 V AC
Relay contacts parameters: 2xNO 5 A/250 V AC1 1250 VA
Modes: Switch on/switch o, Monostable, Bistable, Time
Control: EXTA FREE system transmitters
Radio transmission: 868,32 MHz
Transmission method: One-way without conrmation
Coding: Yes – transmission with addressing
Maximum number of transmitters: 32
Range: Up to 230 m in the open area
Time adjustment: 1 s ÷ 18 h
Ambient temperature range: -10 ÷ +55 oC
Mounting: In a Ø60 junction box
Casing protection degree: IP20
Protection class: III
Dimensions: 47,5 x 47,5 x 20 mm
Weight: 36 g
Reference standard: PN-EN 60669; PN-EN 60950; PN-EN 61000
Channel 1 terminals (12, 11 )
Channel 2 terminals (22, 21)
Power supply terminals (+, -)
Optic signalling of the
receiver’s operation
Programming button
MAXIMUM CURRENT CAPACITY:
ZNP, ZNN or ZNM series
of the power supply
in 14 V DC version
Exemplary LEDIX
series ttings

1
s 2
s n
s
1
s 2
s n
s
CAUTION! The adjusted time can not be deleted.
The application presents how to use LEDIX
series ttings and ROP-03 radio receiver.
LEDIX TICO ttings are connected to OUT1
output. A hermetic LED strip and a exible
LED strip are connected to OUT2 output.
OUT1 and OUT2 outputs are switched on /
switched o by means of the double NO dry
contact (normally open) cooperating with
RNP-02 ush battery transmitter. Time mode
can be realised from every output which
means that the light switches o automati-
cally after a adjusted time is nished. Each
output can be controlled independently.
OPERATION
APPLICATION
MONOSTABLE
the relay operates only while pressing
transmitter’s push-button.
BISTABLE
(one push-button) the device changes
the relay status cyclically always after
pressing the same push-button.
SWITCH ON
the device switches on after pressing the
push-button.
SWITCH OFF
the device switches o after pressing the
push-button.
TIME
the device switches o according to
the adjusted time (tp), but it may be
switched o before the adjusted time
nishes. Default settings - 15 seconds.
TIME PROGRAMMING
Wait again (about 5 seconds) until
LED red diode switches on (rst
signal pulsates, next the signal is
constant)
Wait for the third time
(about 5 seconds)
until LED red diode
switches on (rst
signal pulsates, next
the signal is constant)
After the adjusted time
is nished (the number
of LED red diode ashes)
press PROG push-button
and then release it - TIME
IS ADDED
After the adjusted time
is nished (the number
of LED red diode ashes)
press PROG push-button
and then release it - TIME
IS ADDED
Press PROG push-button of
ROP-03 device and then release
it. LED red diode switches o
and then switches on (signal
pulsates). Every LED diode
pulse equals 1 second
for
CHANNEL 1
for
CHANNEL 2
Press PROG push-button
of ROP-03 device and
then release it. LED red
diode switches o and
then switches on (signal
pulsates). Every LED diode
pulse equals 1 second
Press PROG push-button of ROP-03 device for a longer
time till LED red diode switches on (constant signal).
Next release the PROG push-button. Wait (for about
5 seconds) till LED red diode switches on (rst signal
pulsates, next the signal is constant)
Maximum time is 18 hours for each channel.
RADIO TRANSMITTERS DELETION
Press PROG push-button
of ROP-03 device for a
longer time.
After 5 seconds LED red
diode switches on (the
signal pulsates) and then it
switches o.
Release the push-button
in ROP-03 - MEMORY IS
DELETED.
The device can operate in ve modes for every channel:

RADIO TRANSMITTERS PROGRAMMING CHANNEL 1
RADIO TRANSMITTERS PROGRAMMING CHANNEL 2
BISTABLE mode:
SWITCH ON/SWITCH OFF mode (two push-buttons):
TIME mode (one push-button):
An exemplary programming procedure with the use of P-257/2 remote control. The
procedure for the rest of radio EXTA FREE transmitters is analogous. CAUTION: Every
transmitter can cooperate with ROP-03 in a dierent mode, depending on how they
were added to the device. One transmitter can be added during one programming
cycle. Full memory is signalled with pulsating LED red diode.
Press the transmitter’s
push-button for a longer
time. LED red diode
switches on (rst signal
pulsates, next the signal is
constant)
Press and release
transmitter’s push-button.
LED red diode switches on
(rst the signal pulsates,
next the signal is constant)
Press and release the rst
transmitter’s push-button.
LED red diode switches on
(rst the signal pulsates,
next the signal is constant)
Press and release the same
transmitter’s push-button.
LED red diode switches on
(the signal pulsates) and
next it switches o - THE
TRANSMITTER IS ADDED
Press and release the same
transmitter’s push-button.
LED red diode switches on
(the signal pulsates) and
next it switches o - THE
TRANSMITTER IS ADDED
Press and release the
second transmitter’s
push-button. LED red
diode switches on (the
signal pulsates) and
next it switches o - THE
TRANSMITTER IS ADDED
Press PROG push-button of
ROP-03 device for a longer time
until LED red diode switches on
(constant signal). Next release
PROG push-button.
Press PROG push-button of
ROP-03 device for a longer time
until LED red diode switches on
(constant signal). Next release
PROG push-button
Press PROG push-button of
ROP-03 device for a longer time
until LED red diode switches on
(constant signal). Next release
PROG push-button
Press the
transmitter’s
push-button
for a longer
time.
Release the
transmitter’s
push-button. LED
red diode switches
on (rst the signal
pulsates, next the
signal is constant).
Press the same transmit-
ter’s push-button and
release it. LED red
diode switches on (the
signal pulsates) and
next it switches o - THE
TRANSMITTER IS ADDED.
Press PROG push-button
of ROP-03 device for a
longer time until LED
red diode switches on
(constant signal). Next
release PROG push-
button
MONOSTABLE mode:
CAUTION:
For the monostable mode press the remote control push-button before pressing
PROG push-button.
Press PROG push-button of ROP-03 device for a longer
time until LED red diode switches on (constant signal).
Next release PROG push-button. Wait (about 5 seconds)
until LED red diode switches on (rst the signal pulsates,
next the signal is constant).
Choose one mode out of ve
ROP-03 operation modes and
programme the device similarly
as for channel 1.
OPERATION TABLE
Symbol
RNK-02
RNK-04
P-256/8
P-257/2
P-257/4
RNM-10
RNP-01
RNP-02
RNL-01
RTN-01
RCR-01
RTI-01
RXM-01
P-260
ROP-03
200 200 250 200 200 250 180 180 180 200 180 180 250 -
CAUTION:The given range concerns open area - an ideal condition without any natural
or articial obstacles. If there are some obstacles between a transmitter and a receiver,
it is advisable to decrease the range according to: bricks: from 10 to 40 %, wood and
plaster: from 5 to 20 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100%,
glass: from 10 to 20 %. Over- and underground medium and high electrical power
lines, radio and television transmitters, GSM transmitters set close to a device system
have also a negative inuence on the range.
Other Zamel Receiver manuals

Zamel
Zamel ROP-01 User manual

Zamel
Zamel Exta Free ROM-10 User manual

Zamel
Zamel EXTA LIFE ROM-22 User manual

Zamel
Zamel ledix ROP-04 User manual

Zamel
Zamel SUPLA ROW-07 User manual

Zamel
Zamel ROM-24 User manual

Zamel
Zamel Sundi ST-251 User manual

Zamel
Zamel ROP-01 User manual

Zamel
Zamel ROP-22 User manual

Zamel
Zamel ROP-21 User manual
Popular Receiver manuals by other brands

Kenwood
Kenwood KRF-V7070D Service manual

Omnex
Omnex GENERIC T300 Installation and configuration manual

Yamaha
Yamaha CinemaDSP digital RX-Z1 Service manual

ActionTec
ActionTec ScreenBeam Enterprise 950 quick start guide

Pyramid
Pyramid Ac receiver installation manual

Harman Kardon
Harman Kardon AVR 330 Brochure & specs