14
Ventilation is too weak
If ventilation is not ecient enough, check that:
• the lters are clean and do not need to be changed.
If the lters are dirty, change them as described in the
instructions in the chapter Changing lters.
• ventilation needs have not changed signicantly after
designing and installing the system. For example, if
the number of people using the building or your daily
routines have changed, your ventilation system may
require an update. Contact the system designer.
Ventilation is too noisy
Although our ventilation units are fairly quiet, it is
impossible to make them completely silent. A well-
planned and built system, where the units are not near
the bedrooms, and where sound-proofed doors and
silencers are used, reduces the disturbance caused by
ventilation.
If the ventilation system is noisier than usual, check that:
• the lters are clean and do not need to be changed.
If the lters are dirty, change them as described in the
instructions in the chapter Changing lters.
• the fans are clean and do not need to be cleaned.
If they are dirty, clean them as described in the
instructions in the chapter Cleaning the fans.
• automatic humidity boosting is not in operation. If
the ventilation boost is constantly on*, it can be a sign
of too high indoor air humidity. Contact the system
designer.
If ventilation needs to be silenced only temporarily, you
can activate the Silent mode by tapping the green circle
on the main page of the control panel and choosing
Silent mode. The ventilation unit automatically reverts to
normal operation after a time period congured in the
settings.
* You can check this from the system information menu.
Control panel is not working
If controlling the ventilation unit with the control panel is
not working, check that:
• the control panel battery is not run out. If the battery
is empty, recharge it by placing the control panel in
the wall mount, or connect it to a mobile charger
(µUSB connector), If the battery is faulty, it must be
removed. The control panel will function without a
battery in its wall mount.
• If the control panel is showing "connecting to
network"-icon, check that the ventilation unit is on
and operating. A new pairing connection between
control panel and wall holder can be made by
following the instructions in the Installation manual
on page 12, or Youtube.com, search word: eAir
pariliitos.
Air is too humid
Besides your own observations, you can notice high
humidity by checking the control panel and listening to
the sound level of the ventilation system. If the automatic
humidity boost is constantly* on, it can be a sign that the
indoor air is too humid and the ventilation system is trying
to x the issue. If the indoor air is too humid, check that:
• the lters are clean and do not need to be changed.
If the lters are dirty, change them as described in the
instructions in the chapter Changing lters.
• ventilation needs have not changed signicantly after
designing and installing the system. For example,
if the number of people using the building and/
or the use of sauna and showers has changed, your
ventilation system may require an update. Contact the
system designer.
* You can check this from the system information menu.
Ventilation is not on
If ventilation is not working, check that:
• the service door upper latching screw is locked.
• the unit power cable is plugged in
• the power outlet has power
• the fuse in the fusebox is ok
• there is no alarm shown on the control panel
If the problem is not any of the above, and the ventilation
is not working, contact a maintenance company.