Zennio MAXinBOX SHUTTER 8CH v3 Guide

© Zennio Avance y Tecnología S.L. Edition 1 Further information www.zennio.com Page 1/2
MAXinBOX SHUTTER 8CH v3
Shutter Actuator with up to 8 Shutter Channels with KNX Secure
ZIOMBSH8V3 TECHNICAL DOCUMENTATION
FEATURES
•Up to 8 shutter channels
•Manual output operation with push button and LED status
indicator
•Supports KNX Data Secure
•20 logic functions
•Output timing
•Total data saving on KNX bus failure
•Integrated KNX BCU (TP1-256)
•Dimensions 67 x 90 x 140 mm (8 DIN units)
•DIN rail mounting according to IEC 60715 TH35, with fixing
clamp
•Possibility of connecting different phases in adjacent outputs
•Conformity with the CE, UKCA, RCM directives (marks on the
right side)
1. Upper outputs
2. Lower outputs
3. Programming/Test LED
4. KNX connector
5. Fixing clamp
6. Programming/Test button
7. Output status LED
8. Output control button
Figure 1: MAXinBOX SHUTTER 8CH v3
Programming/Test button: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe
mode. If this button is held for more than 3 seconds, the device enters the test mode. In order to perform a KNX Secure factory reset, while the device
is in safe mode, press the button for 10 seconds until the programming LED changes its state.
Programming/Test LED: programming mode indicator (red). When the device enters the safe mode, it blinks (red) every half second. The test mode is
indicated by the green color. During the start-up (reset or after KNX bus failure) and if the device is not in safe mode, it starts a blue blinking sequence.
GENERAL SPECIFICATIONS
CONCEPT
DESCRIPTION
Type of device
Electric operation control device
KNX supply
Voltage (typical)
29 VDC SELV
Voltage range
21-31 VDC
Maximum
consumption
Voltage
mA
mW
29 VDC (typical)
4.5
130.5
24 VDC¹
10
240
Connection type
Typical TP1 bus connector for 0.8 mm Ø rigid cable
External power supply
Not required
Operation temperature
0 .. +55 °C
Storage temperature
-20 .. +55 °C
Operation humidity
5 .. 95%
Storage humidity
5 .. 95%
Complementary characteristics
Class B
Protection class
II / III (4000 V)
Operation type
Continuous operation
Device action type
Type 1
Electrical stress period
Long
Degree of protection
IP20 / 2 (clean environment)
Installation
Independentdevice to be mountedinside electrical panelswith DIN rail (IEC
60715)
Minimum clearances
Not required
Response on KNX bus failure
Data saving according to parameterization and relays contacts opening
Response on KNX bus restart
Data recovery according to parameterization
Operation indicator
The programming LED indicates programming mode (red) and test mode
(green). Each output LED indicates its status
Weight
452 g
PCB CTI index
175 V
Housing material
PC FR V0 halogen free / 75 °C (housing) - 125 °C (connectors)
¹ Maximum consumption in the worst-case scenario (KNX Fan-In model).
1
5
3
2
4
8
6
7
© Zennio Avance y Tecnología S.L. Edition 1 Further information www.zennio.com Page 2/2
SAFETYINSTRUCTIONSANDADDITIONAL NOTES
•Installation should only be performed by qualified professionals according to the laws and regulations applicable in each country.
•Do not connect the mains voltage nor any other external voltage to any point of the KNX bus; it would represent a risk for the entire
KNX system. The facility must have enough insulation between the mains (or auxiliary) voltage and the KNX bus or the wires of other
accessories, in case of being installed.
•Once the device is installed (in the panel or box), it must not be accessible from outside.
•Keep the device away from water (condensation over the device included) and do not cover it with clothes, paper or any other material
while in use.
•The WEEE logo means that this device contains electronic parts and it must be properly disposed of by following the instructions at
https://www.zennio.com/en/legal/weee-regulation.
•This device contains software subject to specific licences. For details, please refer to https://zennio.com/licenses.
OUTPUTS SPECIFICATIONS AND CONNECTIONS
CONCEPT
DESCRIPTION
Number of outputs
8 shutter channels
Output type / Disconnection type
Potential-free outputs through bistable relays / Micro-disconnection
Rated current per output
AC 8(4) A @ 250 VAC (2000 VA)
DC 5 A @ 30 VDC (150 W)
Maximum load per output
Resistive
2000 W
Inductive
1000 VA
Different phases connection
Possibility of connecting different phases. It is not allowed to connect power
supplies of different order, SELV with NO SELV, in the same block.
Short-circuit protection
NO
Overload protection
NO
Connection method
Screw terminal block (0.5 Nm max.)
Cable cross-section
1.5-4 mm² (IEC) / 26-10 AWG (UL)
Outputs per common
2
Maximum response time
15 ms
Mechanical lifetime (min. cycles)
1 000 000
⚠In order to ensure the expected status of
the relays, please check that the device is
connected to the KNX bus before energizing
the power circuit.
WIRING DIAGRAMS
Figure 2: Wiring example (from left to right): one shutter on channel A
and two shutters on channels A and B with different phases.
Figure 3: Mounting MAXinBOX SHUTTER
8CH v3 on DIN rail
Attaching MAXinBOX SHUTTER 8CH v3 to DIN rail:
Removing MAXinBOX SHUTTER 8CH v3 from DIN rail:
A1 A2
M
N
L
B1 B2 A1 A2
M
N
LM M
B1 B2
B1 B2
A1 A2
N
L
B1 B2
B1A1 B2A2
A1 A2
N
L
B1 B2
B1 B2B1 B2
A1 A2
N
L
B1 B2
L1 L2 L1 L2
L1 L2 L3 L4
A1 A2 B1 B2 C1 C2 D1 D2
E1 E2 F1 F2 G1 G2 H1 H2
L1 L2
L3 L1
F1 F2 F3 V1
 




 
 







This manual suits for next models

1

Other Zennio Controllers manuals

Zennio ZoningBOX 6 Guide

Zennio

Zennio ZoningBOX 6 Guide

Zennio inBOX 24 v2 User manual

Zennio

Zennio inBOX 24 v2 User manual

Zennio MAXinBOX 16 Guide

Zennio

Zennio MAXinBOX 16 Guide

Zennio ALLinBOX 1612 v2 User manual

Zennio

Zennio ALLinBOX 1612 v2 User manual

Zennio ZN1CL-IRSC User manual

Zennio

Zennio ZN1CL-IRSC User manual

Zennio MAXinBOX SHUTTER 4CH User manual

Zennio

Zennio MAXinBOX SHUTTER 4CH User manual

Zennio MAXinBOX 8 v3 Guide

Zennio

Zennio MAXinBOX 8 v3 Guide

Zennio ZN1VI-TPZAS User manual

Zennio

Zennio ZN1VI-TPZAS User manual

Zennio MAXinBOX FC 0-10V FAN User manual

Zennio

Zennio MAXinBOX FC 0-10V FAN User manual

Zennio ACTinBOX MAX6 User manual

Zennio

Zennio ACTinBOX MAX6 User manual

Zennio MAXinBOX 24 v2 Guide

Zennio

Zennio MAXinBOX 24 v2 Guide

Zennio MAXinBOX FANCOIL 2CH2P User manual

Zennio

Zennio MAXinBOX FANCOIL 2CH2P User manual

Zennio MAXinBOX FC 0-10V VALVE User manual

Zennio

Zennio MAXinBOX FC 0-10V VALVE User manual

Zennio FANinBOX 230V 1CH Guide

Zennio

Zennio FANinBOX 230V 1CH Guide

Zennio MAXinBOX66 Guide

Zennio

Zennio MAXinBOX66 Guide

Zennio MAXinBOX 66 Guide

Zennio

Zennio MAXinBOX 66 Guide

Zennio MAXinBOX FC 0-10V VALVE User manual

Zennio

Zennio MAXinBOX FC 0-10V VALVE User manual

Zennio FANinBOX 110V 1CH Guide

Zennio

Zennio FANinBOX 110V 1CH Guide

Zennio MAXinBOX 66 Guide

Zennio

Zennio MAXinBOX 66 Guide

Zennio HeatingBOX 230V 4X Guide

Zennio

Zennio HeatingBOX 230V 4X Guide

Zennio MAXinBOX FANCOIL 4CH2P Guide

Zennio

Zennio MAXinBOX FANCOIL 4CH2P Guide

Zennio MAXinBOX FC 0-10V FAN Guide

Zennio

Zennio MAXinBOX FC 0-10V FAN Guide

Zennio inBOX 24 vT User manual

Zennio

Zennio inBOX 24 vT User manual

Zennio Roll-ZAS User manual

Zennio

Zennio Roll-ZAS User manual

Popular Controllers manuals by other brands

Lamtec ETAMATIC manual

Lamtec

Lamtec ETAMATIC manual

Mitsubishi Electric LGF-100GX-E Handbook

Mitsubishi Electric

Mitsubishi Electric LGF-100GX-E Handbook

FAAC E024 U manual

FAAC

FAAC E024 U manual

Maretron MPOWER CLMD16 user manual

Maretron

Maretron MPOWER CLMD16 user manual

HPE Nimble Storage HF Series Hardware guide

HPE

HPE Nimble Storage HF Series Hardware guide

Emerson Asco 642 Series Installation and maintenance instructions

Emerson

Emerson Asco 642 Series Installation and maintenance instructions

Capstone Microturbine C1000 Series installation guide

Capstone

Capstone Microturbine C1000 Series installation guide

Crouzet em4 B26 manual

Crouzet

Crouzet em4 B26 manual

Mohlenhoff OEM-Actuator 24 V technical information

Mohlenhoff

Mohlenhoff OEM-Actuator 24 V technical information

CB ELECTRONICS TMC-1 Setup guide

CB ELECTRONICS

CB ELECTRONICS TMC-1 Setup guide

FLIR Raymarine p70s Installation & operation instructions

FLIR

FLIR Raymarine p70s Installation & operation instructions

Compit B750 T-1 OPERATING AND INSTALLATION Manual

Compit

Compit B750 T-1 OPERATING AND INSTALLATION Manual

Rowley R-TEC Automation ARC Motor Programming quick start guide

Rowley

Rowley R-TEC Automation ARC Motor Programming quick start guide

Datakom DKG-109 user manual

Datakom

Datakom DKG-109 user manual

Mitsubishi FX Series Hardware manual

Mitsubishi

Mitsubishi FX Series Hardware manual

LOYTEC L-VIS user manual

LOYTEC

LOYTEC L-VIS user manual

Kapego LED 843022 manual

Kapego LED

Kapego LED 843022 manual

Midea KJRH-120H / BMKO-E Operation manual

Midea

Midea KJRH-120H / BMKO-E Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.