ZigBoat ZB204 User manual

eng
KitchenBathroom
Garage
max 10 m
Salon Cabin
7. When the LED button stops ashing, the
Smoke Alarm has successfully joined the
ZigBoat™network.
Tocheckthecorrectconguration,selectthe
overviewtabintheZigBoat™App.(g.5)
Green dot: The sensor is working properly
Red dot: The sensor is not able to reach the
Gateway.
• Please check the battery status;
• Please check that the serial number has been
entered correctly
• In case of a weak or a bad signal, change the
location of the ZigBoat™ Smoke Alarm Sensor
“OK”: No smoke detected
“ALARM”: The sensor detects smoke and
will send push notication if the gateway is
connected to internet
min 50 cm wall
ceiling
min 30 cm
max 50 cm
wall
ceiling
WALL PLACEMENT
TheSmokeAlarmSensorshouldbebetween
30cm(12”)and50cm(20”)fromtheceiling.
CEILING PLACEMENT
Thesmokealarmshouldbeaminimumof50
cm(20”)fromthewall.
There should be at least one smoke alarm
sensor per area with a maximum distance of
10meters(30’)betweensmokealarmsensors.
Mounting
1. Detach the alarm from the mounting base
bytwistingcounter-clockwise.
2. Use the mounting base ring to mark the
screwholesontheceilingoronthewall.
3. Use enclosed screws and plugs to install
themountingbaseinthemarkedposition.
4.Ifthebatteryismissingorinsertedincorrectly,
it will be impossible to attach the alarm in
themountingbase.
5.Attachthealarmbytwistingclockwiseuntil
itclicks.
Placement
• PlacetheSmokeAlarmSensorindoorsata
temperaturebetween0-50°C(32-122°F).
• Thedistancebetweenthesmokealarmand
walls,ventilationorotherobstacles,should
beatleast50cm(20”).
• The distance between the Alarm Sensor
andan ovenor cookershould be atleast 4
meters.
• The alarm should be placed within reach
forbatterytestingandmaintenance.
• Thealarmshouldnotbeplacedatthetop
ofhighpointedceilingsorinceilingcorners
orwithin50cm(20”)ofawall.
2. Tondtheserialnumberdetachthesensor
mountbase.
3. You can change the devices name by
selecting “Name” (g. 4). Then, press the
button“AddDevice”
4. Insert the battery (1xCR123) taking note of
polarity.
Product description
Thesmoke alarmsensorwillwarn occupants
when smoke is detected by sounding a loud
siren. While away from the boat, the system
willalsosendaninstantnoticationofpotential
rethroughthegateway.
UsingtheZigbeecommunicationprotocol,the
smoke alarm sensor can also activate other
smokealarmsensorsandtheirsirensonboard.
Precautions
• Do not remove the product label as it
containsimportantinformation.
• Donotpaintthealarm.
• Avoid placing the Smoke Alarm Sensor in
dustyrooms.
• Donot placethe sensorin placeswhereit
is damp or has naturally occurring gas or
smoke.
Version1.0
OWNER MANUAL
Smoke Alarm Sensor
RECOMMENDED LOCATIONS
• Cabin
• Salon
code: ZB204
Adding the sensor to the Gateway
NOTE:  Make sure the Gateway is turned on
and congurated, for more details see the
Gatewayownermanual.
1. OpentheZigBoat™App,selecttheGateway
in the ZB Gateways menu, waiting a few
seconds. then select the menu button on
the top right (g. 1) Select “Device list” (g.
2). Add the sensor by entering the serial
numberwhichisonthesensor’slabel(g.3).
Fig. 1Fig. 2
Fig. 3
Fig. 4
Fig. 5
CR123A
PRODUCT
LABEL
5. The
Smoke Alarm Sensor
 will now start
searching(upto15minutes)fortheZigBoat™
networktojoin.
6. WhilesearchingfortheZigBoat™networkto
join,theLEDbuttonashesred.
OK
Smoke Sensor
Smoke #1
• Galley
Disposal
Dispose the product and battery properly at
the end of life. This is electronicwastewhich
shouldberecycled.
1. To replace the battery, detach the smoke
alarmfromthe mountingbasebytwisting
counter-clockwise.
2. Replacethebatterynotingthepolarity.The
SmokeAlarmSensoruses1xCR123battery.
3. Attachthe alarmin themounting baseby
twisting clockwise until it clicks, and test
thealarm.
EN14604 : 2005/AC:2008
DoP no.: 2102-002
0333
16
DistributedbyGlomexSrl
viaFaentina165/G
48124Ravenna
Italy
Glomex assumes no responsibility for any
errors, which may appear in this manual.
Furthermore,Glomexreservestherighttoalter
the hardware, software, and/or specications
detailedhereinatanytimewithoutnotice,and
Glomex does not make any commitment to
update the information contained herein. All
thetrademarkslistedhereinareownedbytheir
respectiveowners.
All rights reserved.
Glomex guarantees the Smoke Alarm Sensor
(ZB204) against manufacturing defects for
a period of 2 years from date of purchase.
Warranty can be in the form of repair or
replacement of the unit if manufacturing
defects have been found and are conrmed
by Glomex or one of its aliates. In order to
validate warranty, either the original sales
receiptoracopymustbeprovidedatthetime
warranty is requested. Before returning any
itemsforwarranty,pleasecontacttheGlomex
Customer Service department to receive a
RMAwhichshouldbecompletedandsentwith
theunittothefollowingaddress:
GLOMEXS.r.l.
ViaFaentina165/G
48124Ravenna(Italy)
completewithall theaccessories suppliedat
the time of purchase for shipment.The serial
number must neither be erased nor made
illegible,otherwisethewarrantywillbevoided.
Warranty
Other certications
• ZigBee®certied
• RoHS compliant according to the EU
Directive2002/95/EC
• TheZigBoat™SmokeSensorisnotintended
as a device to prevent and detect re and
smoke.
CE certication
The CE mark axed to this product conrms
its compliance with the European Directives
whichapplytotheproductand,inparticular,its
compliancewiththeharmonizedspecications
ofstandardEN14604:2005/AC:2008relatingto
ConstructionProductsRegulation305/2011.
Other information
• Notelocalregulationsaboutinformationto
yourinsurancecompanyregardinginstalled
smokealarms.
Battery replacement
CAUTION: When removing cover for battery
change - Electrostatic Discharge (ESD) can
harmelectroniccomponentsinside.
CAUTION: RISK OF EXPLOSION IF BATTERIES
ARE REPLACED BY AN INCORRECT TYPE.
DISPOSE OF THE BATTERIES IN ACCORD-
ANCE WITH INSTRUCTIONS.
Resetting
Resetting is needed it you want to connect
yourSmokeAlarmSensortoanothergateway
or if you need to perform a factory reset to
eliminateabnormalbehavior.
STEPS FOR RESETTING
1. Detachthesensorfromthemountingbase
bytwistingitcounterclockwise.
2. PressandholdtheLEDbuttonuntilitashes
continuously.
3. Releasethebutton.
4. Resettingprocessiscompletewhenthered
LEDstartstoblink.
Modes
SEARCHING GATEWAY MODE
Red LED light in the back of the device is
ashingeverysecond(upto15minutes)
NORMAL MODE
FrontLEDisashingevery45seconds.
ALARM MODE
ThesimultaneousashingofthefrontredLED
andsoundingofintermittentaudiblesignal.
Whensmokeisdetected,thealarmwillsound.
Fault nding & cleaning
• Dust particles in the smoke chamber can
beremovedbyvacuumingthemesh.
• High humidity condensation can be
resolvedbydryingthesmokealarmsensor.
• If the smoke alarm sensor does not work
when the test button is pushed, the
probablecauseisafaultybattery.Replace
thebatteryifitiswornout.
• In case of a bad or weak signal, change
the location of the smoke alarm sensor.
Otherwiseyoucanrelocateyourgateway.
• Ifthesearchforthegatewayhastimedout,
ashortpressontheLEDbuttonwillrestartit.
Consultailmanualeutenteinitalianosu:
Consultez le manuel d’utilisation en français
sur:
SiehedasdeutscheBenutzerhandbuchauf:
Consulteelmanualdeusuarioenespañolen:
Testing
• Always test the working order of the
Smoke Alarm Sensor after installation or
batterychange.
• When pressing the sensor button, the
alarmsoundshouldbeheard.
• Anetworkalarmtestcanbeperformedby
holdingdownthesensorbuttonforatleast
6.5seconds.
Press the “button/top” of the Alarm Sensor
to acknowledge and stop the siren.  For 10
minutes after the alarm has been silenced,
there will be no additional alarms to allow
ventilationofthesmokebeingdetected.
LOW BATTERY MODE
Simultaneous audible signals and front LED
ashes every 45 seconds, means that the
batteryshouldbereplaced.
REPLACE DEVICE MODE
IftherearenoaudiblesignalsorthefrontLED
does not ash every 45 seconds, the sensor
should be replaced. The life expectancy of
smoke alarm sensors is generally 10 years,
after which point their sensors begin to lose
sensitivity.

Other ZigBoat Accessories manuals

ZigBoat ZB206 User manual

ZigBoat

ZigBoat ZB206 User manual

ZigBoat Schuko ZB207 User manual

ZigBoat

ZigBoat Schuko ZB207 User manual

ZigBoat ZB203 User manual

ZigBoat

ZigBoat ZB203 User manual

Popular Accessories manuals by other brands

Waterpik 200 Series instruction manual

Waterpik

Waterpik 200 Series instruction manual

MITECH GEMINI Series Installation and user manual

MITECH

MITECH GEMINI Series Installation and user manual

Kemot URZ3148 owner's manual

Kemot

Kemot URZ3148 owner's manual

GTV CR-13 Circuit Diagram

GTV

GTV CR-13 Circuit Diagram

SkyBell SH02300BZ Troubleshooting

SkyBell

SkyBell SH02300BZ Troubleshooting

Procon Grumbach MP GTFS operating manual

Procon

Procon Grumbach MP GTFS operating manual

PCB Piezotronics 401B04 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 401B04 Installation and operating manual

ULTIMATE SPEED UPBS 12000 A1 Operation and safety notes

ULTIMATE SPEED

ULTIMATE SPEED UPBS 12000 A1 Operation and safety notes

Advaning CLASSIC Series owner's manual

Advaning

Advaning CLASSIC Series owner's manual

Laser PB-CJ12000 quick start guide

Laser

Laser PB-CJ12000 quick start guide

Hach ORBISPHERE 31x9 Series Basic user manual

Hach

Hach ORBISPHERE 31x9 Series Basic user manual

Nordic Deltaco PB-C1004 user manual

Nordic

Nordic Deltaco PB-C1004 user manual

Conrad 99 77 77 operating instructions

Conrad

Conrad 99 77 77 operating instructions

IFM Electronic efector 800 VSE100 operating instructions

IFM Electronic

IFM Electronic efector 800 VSE100 operating instructions

Endress+Hauser OUSAF46 operating instructions

Endress+Hauser

Endress+Hauser OUSAF46 operating instructions

PCB Piezotronics 261A02 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 261A02 Installation and operating manual

Xenith BACK PLATE Assembly instructions

Xenith

Xenith BACK PLATE Assembly instructions

Fern-Howard FHL414 Setup instructions

Fern-Howard

Fern-Howard FHL414 Setup instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.