ZKTeco Atlas 00 Series User manual

Installation Guide
Atlas x00 Series Access Control Panels
Version: 1.0
Date: July, 2019

2
Atlas x00 Series Access Control Panels Installation Guide
What’s in the Box
4 Diodes4 Screws & Anchors 1 Screwdriver

3
Atlas x00 Series Access Control Panels Installation Guide
CONTENTS
What’s in the Box..................................................................... 2
Optional Accessories............................................................ 4
Safety Precautions................................................................... 5
Product PIN Diagram............................................................ 6
LED Indicators............................................................................ 7
Product Dimension................................................................ 8
Installation of Panel & Cabinet...................................... 9
Wiring Legend........................................................................ 10
Power Wiring Diagram .................................................... 11
Wiegand Connection........................................................ 12
OSDP Connection................................................................ 13
REX Connections.................................................................. 14
Lock Connection .................................................................. 15
AUX. I/O Connection ........................................................ 16
Ethernet Connection ........................................................ 17
Typical Installation ............................................................... 18
Troubleshooting ................................................................... 19
Electrical Specifications .................................................. 20
Introduction ............................................................................ 23
Understanding the Atlas Series Network .......... 24
Initial Controller Setup ..................................................... 25
Connect the Controller to the Network ............. 31
Complete the Configuration ...................................... 32
Add a User and Test Access ......................................... 36
Add Secondary Controllers ......................................... 38
Mobile App................................................................................. 39
Special Considerations for Complex Networks ..... 43
Where to Go Next ............................................................... 43
Web Management Application
Programming Guide starts at
page 22

4
Atlas x00 Series Access Control Panels Installation Guide
Optional Accessories
Wiegand Card Reader Prox Card
Alarm
Door Sensor Exit Button
Atlas x00 Series Metal Cabinet
CR10E Card Enroller

5
Atlas x00 Series Access Control Panels Installation Guide
Safety Precautions
The following precautions are to keep user’s safe and prevent any damage.
Please read carefully before installation.
Do not expose to direct sunlight, water, dust and soot.
Do not place any magnetic objects near the product. Mag-
netic objects such as magnets, CRT, T V, monitors or speakers
may damage the device
Do not place the device next to heating equipment.
Prevent water, drinks or chemicals leaking into the device.
This product is not intended for use by children unless they
are supervised.
Do not drop or damage the device.
Do not disassemble, repair or modify the device.
Do not use the device for any purpose other than those
specied.
Remove dust or dirt regularly. While cleaning, wipe dust o
with a smooth cloth or towel instead of water.
Contact your supplier in case of any problem!

6
Atlas x00 Series Access Control Panels Installation Guide
Product PIN Diagram
Ethernet Port
Atlas Power
Figure 1
4 Lock & Door Sensor
Aux Input
RESET
Aux Output
Power Detection
USB Port
Wiegand
Reader 3
WIFI
Wiegand
Reader 4
Wiegand
Reader 1
Wiegand
Reader 2
OSDP
Reader
Status Indicator
The function of reset button (once reset button is pressed, LED will blink fast):
1. Press reset button for about 2-5 seconds, zk firmware will check if there is a USB disk which stores an upgrade package
inserted into controller, if yes, then controller will do firmware upgrade automatically.
2. Press reset button for about 5-10 seconds, zk firmware will temporarily set IP to default 169.254.202.242.
RS485 Comm.
(not used)
(POE)

7
Atlas x00 Series Access Control Panels Installation Guide
LED Indicators
COMM1 Flashing Yellow indicates the
system is communicating with upper-level
devices (for example, the PC).(NOT USED)
COMM2 Flashing Yellow indicates the
system is communicating with lower-level
devices (for example, readers).
Flashing (RUN) Green LED indicates
that panel is in normal working state.
LINK Solid Green LED indicates TCP/IP
communication is normal
Flashing (ACT )Yellow LED indicates
data communication is in progress
Flashing (WLAN) Green LED indicates
the system is communicating in wireless
(Wi-Fi) mode.
Flashing (DOOR) Green LED indicates a
door opening signal (a door is opened).
Solid (POWER) Red LED indicates the
panel is powered on.
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 8
Figure 7

8
Atlas x00 Series Access Control Panels Installation Guide
Product Dimension
Atlas x00 Series Metal Cabinet
Figure 10
Figure 9
15in (380mm)
11in
(280mm)
3.15in
(80mm)
The surface of the metal cabinet is high temperature baking paint, which can prevent rust.
Atlas-100 Atlas-200 Atlas-400
4.17 in (140mm)
6.3in (160mm) 7.75in (197mm)
6.73in (171mm)
7.75in (197mm)

9
Atlas x00 Series Access Control Panels Installation Guide
Cable Conduit
(Punch hole for cables)
Atlas Panel
Heat Dissipation Grill
Mounting HolesState Indicators
We recommend drilling the mounting plate screws into solid wood (i.e. stud/beam). If a stud/beam cannot be
found, then use the supplied drywall plastic mollies (anchors).
Step 1
Pass the cable through holes
Step 2
Mount the Metal Cabinet
Step 3
Fasten the Atlas Panel with four screws.
Figure 11
Figure 12
Installation of Panel & Cabinet

10
Atlas x00 Series Access Control Panels Installation Guide
Wiring Legend
Ethernet Cable
P
U
S
H
T
O
T
E
S
T
W
E
E
K
L
Y
P
U
S
H
T
O
T
E
S
T
W
E
E
K
L
Y
FIRE
ALARMDetector
Door Sensor
Floodlight
Exit Button
Normally
Open Lock
Normally
Close Lock
Card Reader
12V DC Power
Supply
The auxiliary input may be connected to infrared motion sensors, fire alarms, or smoke detectors. The auxiliary
output may be connected to alarms, cameras or door bells, etc.
Figure 13
OSDP Reader
POE

11
Atlas x00 Series Access Control Panels Installation Guide
Power Wiring Diagram
Figure 14
12V DC
POE Power Supply
POE
ETHERNET

12
Atlas x00 Series Access Control Panels Installation Guide
Wiegand Connection
Wiegand Card Reader
Beeper
Green LED
Wiegand D1
Wiegand D0
GND
DC+(6-14V)
Figure 15
16 or 18 AWG shielded
cable recommended

13
Atlas x00 Series Access Control Panels Installation Guide
OSDP Connection
Figure 16
OSDP Reader
D0
GND
DC
D1

14
Atlas x00 Series Access Control Panels Installation Guide
REX Connections
Exit Button
IR Sensor
Separate Power Supply
Unused
NO
COM COM
NO
12V DC ( + )
12V DC ( - )
Figure 17

15
Atlas x00 Series Access Control Panels Installation Guide
Lock Connection
FR107
Diode
GND
GND
12V DC
12V DC
ETHERNET
Figure 18
+
-
Sensor
Sensor
Door Contact
Normally Closed Lock

16
Atlas x00 Series Access Control Panels Installation Guide
AUX. I/O Connection
AUX. Input Connection
AUX. Output Connection
12V DC
12V DC
12V DC
GND
P
U
S
H
T
O
T
E
S
T
W
E
E
K
L
Y
P
U
S
H
T
O
T
E
S
T
W
E
E
K
L
Y
FIRE
ALARM
ALARM
ETHERNET
ETHERNET
Figure 20
Figure 19

17
Direct Connection
To connect Atlas-400 with a PC directly, connect both devices with a straight network
cable. As the Atlas-400 supports auto MDI/MDIX, it is not necessary to use a crossover
type cable.
ETHERNET
ETHERNET
Atlas x00 Series Access Control Panels Installation Guide
Ethernet Connection
LAN Connection
Important Notes:
1. Both 10Base-T and 100Base-T are supported.
2. This cable distance must be less than 330 ft. (100m).
3. For cable length of more than 330 ft. (100m). use HUB to amplify the signal.
Figure 21
Figure 22
CAT5e or CAT6 ethernet
cable recommended

18
Atlas x00 Series Access Control Panels Installation Guide
Installation Diagram
Sensor
CEILING
INDOOROUTDOOR
Atlas x00 Access Control Bundle
Electric Lock
Exit Button
Reader for “Out” DoorReader for “In”Door
Figure 23
Ethernet Communication wire
220/110 V Input

19
Atlas x00 Series Access Control Panels Installation Guide
Troubleshooting
1. How do I connect two-way doors?
› Connect “Out” door readers as needed, in pairs with “In”door readers according to the follow-
ing table.
Model “In”Reader Pairs with "Out" Reader
1-door 1 2
2-door
1 3
2 4
4-door
15 (RS485 connection)
26 (RS485 connection)
37 (RS485 connection)
48 (RS485 connection)
› Connect door locks and sensors to the port for their “In”door.
› See “Initial Controller Setup” in the “Programming Guide” for conguration instructions and
additional options.
2. What does it mean when I get “Access Denied (Unknown Format)?”
› Your D0 and D1 wiring might be reversed.
› The type of card you swiped might not be recognized. See“Add a User and Test Access”in the
“Programming Guide.”
3.How do I connect a third party reader or a stand-alone reader to an Atlas x00
panel?
› Connect the wiegand output to the WD0 and WD1 of the stand-alone readers on the panel’s
reader port.
Note: The board can only supply 12 V DC, 300mA power so an external power supply may be required.
4. What kind of wire is recommended for the panel?
› 16 or 18 AWG twisted shielded wire is recommended.
5. What is the default IP of the panel?
› 169.254.202.242 - This is a “link local”IP address. See“Initial Controller Setup”in the “Program-
ming Guide”for link local usage.
6. How long is the device under warranty?
› 2 Years from original purchase date, replacement/repair of hardware under ZK standard war-
ranty requires an evaluation of the failed system by a ZK Technical Support specialist, and the
issuance of a Technical Support RMA number.

20
Atlas x00 Series Access Control Panels Installation Guide
Electrical Specications
Minimum
Typical
Maximum
Notes
WORKING POWER SUPPLY
Voltage (V) 9.6 12 14.4 Use regulated DC power
adaptor only
Current (A) 2
ELECTRONIC LOCK RELAY OUTPUT
Switching voltage (V) 12V 30V Use regulated DC power
adaptor only
Switching Current (A) 2 3
Auxiliary relay output
Switching voltage(V) 12V 30V Use regulated DC power
adaptor only
Switching Current (A) 1.25 1.5
SWITCH AUX. INPUT
VIH (V) TBD 30V
VIL (V) TBD
Pull-up resistance (Ω) 4.7k The input ports are pulled
up with 4.7k resistors
WIEGAND INPUT
Voltage (V) 10.8 12 13.5
Current (mA) 500
ZK ELECTRONIC LOCK
Voltage (V) 10.8 12 13.2
Current (mA) 500
This manual suits for next models
3
Table of contents
Other ZKTeco Control Panel manuals
Popular Control Panel manuals by other brands

rako
rako RCM100 Installation, Programming and Operating Instructions

Siemens
Siemens 3KC ATC6500 operating instructions

Gewiss
Gewiss Chorus GW 10 753 manual

Woodward
Woodward easYgen-300 Operation manual

AEG
AEG COMPETENCE 3300 S operating instructions

Extron electronics
Extron electronics ACP VC1 D Setup guide