ZKTeco Atlas x60 Series User manual

Installation Guide
Atlas x60 Series
Access Control Panels

2
Atlas x60 Series Access Control Panels Installation Guide
What’s in the Box
4 Diodes4 Screws & Anchors 1 Screwdriver
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F

3
Atlas x60 Series Access Control Panels Installation Guide
CONTENTS
What’s in the Box.......................................................................2
Optional Accessories..............................................................4
Safety Precautions.....................................................................5
Product PIN Diagram..............................................................6
LED Indicators..............................................................................7
Product Dimension..................................................................8
Installation of Panel & Cabinet.........................................9
Wiring Legend..........................................................................10
Power Wiring Diagram ......................................................11
Wiegand Connection..........................................................12
OSDP Connection..................................................................13
FR1500A Connection..........................................................14
DIP Switch Setting for FR1500A Device ID..........15
REX Connections....................................................................16
Lock Connection ....................................................................17
AUX. I/O Connection...........................................................18
Ethernet Connection ..........................................................19
Typical Installation .................................................................20
Troubleshooting .....................................................................21
Reader 485 Setting Table..................................................22
Electrical Specifications ....................................................24
Introduction ..............................................................................27
Understanding the Atlas Series Network ............28
Initial Controller Setup .......................................................29
Connect the Controller to the Network ...............35
Complete the Configuration ........................................36
Add a User and Test Access ...........................................40
Add Secondary Controllers ...........................................43
Mobile App...................................................................................44
Special Considerations for Complex Networks .......48
Where to Go Next .................................................................48
Web Management Application
Programming Guide starts at
page 26

4
Atlas x60 Series Access Control Panels Installation Guide
Optional Accessories
Wiegand Card Reader
SLK20R Enrollment reader
FR1500A FP & Prox Reader
Prox Card
CR10E Card Enrollment Reader
Exit Button
Atlas x60 Metal Cabinet
Door Sensor

5
Atlas x60 Series Access Control Panels Installation Guide
Safety Precautions
The following precautions are to keep user’s safe and prevent any damage.
Please read carefully before installation.
Do not expose to direct sunlight, water, dust and soot.
Do not place any magnetic objects near the product.
Magnetic objects such as magnets, CRT, T V, monitors or
speakers may damage the device
Do not place the device next to heating equipment.
Prevent water, drinks or chemicals leaking into the device.
This product is not intended for use by children unless they
are supervised.
Do not drop or damage the device.
Do not disassemble, repair or modify the device.
Do not use the device for any purpose other than those
specied.
Remove dust or dirt regularly. While cleaning, wipe dust o
with a smooth cloth or towel instead of water.
Contact your supplier in case of any problem!

6
Atlas x60 Series Access Control Panels Installation Guide
Product PIN Diagram
Status Indicator
4 Lock & Door Sensor
Aux Input
Reader Ethernet Port
(not used)
Wiegand
Reader 3
Atlas Power
RESET
Figure 1
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Aux Output
Power Detection
USB Port
WIFI
Wiegand
Reader 4
Wiegand
Reader 1
Wiegand
Reader 2
RS485 Reader
Ethernet Port
RS485 Communication
(not used)
The function of reset button (once reset button is pressed, LED will blink fast):
1. Press reset button for about 2-5 seconds, zk firmware will check if there is a USB disk which stores an upgrade package
inserted into controller, if yes, then controller will do firmware upgrade automatically.
2. Press reset button for about 5-10 seconds, zk firmware will temporarily set IP to default 169.254.202.242.
(POE)

7
Atlas x60 Series Access Control Panels Installation Guide
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
COMM1 Flashing Yellow indicates the
system is communicating with upper-level
devices (for example, the PC).
COMM2 Flashing Yellow indicates the
system is communicating with lower-level
devices (for example, readers).
Flashing (RUN) Green LED indicates
that panel is in normal working state.
LED Indicators
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
LINK Solid Green LED indicates TCP/IP
communication is normal
Flashing (ACT )Yellow LED indicates
data communication is in progress
Flashing (WLAN) Green LED indicates
the system is communicating in wireless
(Wi-Fi) mode.
Flashing (DOOR) Green LED indicates
a door opening signal (a door is opened).
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 8
Figure 7
Solid (POWER) Red LED indicates the
panel is powered on.

8
Atlas x60 Series Access Control Panels Installation Guide
Product Dimension
Atlas-160 Atlas-260 Atlas-460
Atlas x60 Metal Cabinet
Figure 10
Figure 9
AUX1
GND
AUX2
NC
COM
NO
SEN
GND
BUT
PWR
GND
RUN
COMM
GND
485B
485A
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
BREAK
GND
ACFAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
CO
MM
RUN
GND
PW
R
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
A
CFAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
CO
MM
RUN
GND
PW
R
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
A
CFAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
6.73in
(171mm)
4.17in
(106mm)
15in (380mm)
7.75in (197mm)7.75in (197mm)6.3in (160mm)
11in
(280mm)
3.15in
(80mm)

9
Atlas x60 Series Access Control Panels Installation Guide
Installation of Panel & Cabinet
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
A
CFAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Cable Conduit
(Punch hole for cables)
Atlas x60 Panel
Heat Dissipation Grill
Mounting HolesState Indicators
We recommend drilling the mounting plate screws into solid wood (i.e. stud/beam). If a stud/beam cannot be
found, then use the supplied drywall plastic mollies (anchors).
Step 1
Pass the cable through holes
Step 2
Mount the Metal Cabinet
Step 3
Fasten the Panel with four screws.
Figure 11
Figure 12

10
Atlas x60 Series Access Control Panels Installation Guide
Wiring Legend
P
U
S
H
T
O
T
E
S
T
W
E
E
K
L
Y
P
U
S
H
T
O
T
E
S
T
W
E
E
K
L
Y
FIRE
ALARMDetector
Ethernet Cable
Floodlight
Exit Button
Normally
Open Lock
Normally
Close Lock
Card Reader
12V DC
Power Supply
Figure 13
FR1500A/OSDP
Reader
The auxiliary input may be connected to infrared motion sensors, fire alarms, or smoke detectors. The auxiliary
output may be connected to alarms, cameras or door bells, etc.
POE
Door Sensor
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F

11
Atlas x60 Series Access Control Panels Installation Guide
Power Wiring Diagram
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
ACFAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Figure 14
12V DC

12
Atlas x60 Series Access Control Panels Installation Guide
Wiegand Connection
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Wiegand Card Reader
Figure 15
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Beeper
Green LED
Wiegand D1
Wiegand D0
GND
DC+(6-14V)

13
Atlas x60 Series Access Control Panels Installation Guide
OSDP Connection
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
ACFAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
ETHERNET
OSDP Reader
Figure 16
NOTE: OSDP and ZKTeco RS485 (FR1500A readers) cannot both be connected to one control panel.
D0 D1
GND
DC
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F

14
Atlas x60 Series Access Control Panels Installation Guide
FR1500A Connection
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
ACFAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
12V DC
ETHERNET
3FR1500A
2FR1500A
1FR1500A 8FR1500A
Figure 17
12V DC
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F

15
Atlas x60 Series Access Control Panels Installation Guide
DIP Switch Setting for FR1500A Device ID
DIP Switch
Figure 18
RS485 Terminal Resistance
8
4
2
1
Address Switch Settings Address Switch Settings
1 5
2 6
3 7
4 8
Important Notes
1. There are six DIP switches on the
back of FR1500A, Switches 1-4 is for
RS485 address, switch 5 is reserved,
switch 6 is for reducing noise on long
RS485 cable.
2. Set the odd number for IN reader,
and the even number for OUT reader
(for eg. For two readers for one door-
the RS485 address 1 is for IN reader,
RS485 address 2 is for OUT reader)
3. If FR1500A is powered from Atlas-460
panel ,the length of wire should be
less than 100 meters or 330 ft.
4. The External RS485 interface can
supply maximum 500mA current,
The FR1500A’s startup current is
240mA. So Atlas-460 only can only
power two FR1500As.
5. If the cable length is more than
200 meters or 600 ft , the number 6
switch should be ON as below
Distance: More than 200 meters

16
Atlas x60 Series Access Control Panels Installation Guide
REX Connections
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Exit Button
IR Sensor
Separate Power Supply
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Unused
NO
NO
COM
COM
12V DC(+)
12V DC( - )
Figure 19

17
Atlas x60 Series Access Control Panels Installation Guide
Lock Connection
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
FR107
Diode
GND
GND
Sensor
Sensor
CO
MM
RUN
GND
PW
R
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
ACFAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
12V DC
Door Contact
ETHERNET
Figure 20
+
-
ETHERNET

18
Atlas x60 Series Access Control Panels Installation Guide
AUX. I/O Connection
AUX. Input Connection
AUX. Output Connection
CO
MM
RUN
GND
PW
R
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
A
CFAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
12V DC
ALARM
ETHERNET
ETHERNET
Figure 22
Figure 21
12V DC
12V DC
GND
P
U
S
H
T
O
T
E
S
T
W
E
E
K
L
Y
P
U
S
H
T
O
T
E
S
T
W
E
E
K
L
Y
FIRE
ALARM
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
AC FAIL
BAT FAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
CO
MM
RUN
GND
PW
R
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
A
CFAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F

USB
USB
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
ACFAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Direct Connection
To connect Atlas-460 with a PC directly, connect both devices with a straight
network cable. As the Atlas-460 supports auto MDI/MDIX, it is not necessary to
use a crossover type cable.
SLK20R Enrollment reader
SLK20R Enrollment reader
ETHERNET
ETHERNET
19
Atlas x60 Series Access Control Panels Installation Guide
Ethernet Connection
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
A
CFAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
COMM
RUN
GND
PWR
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
NC
COM
NO
SEN
GND
BUT
+12V
GND
485B
485A
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
485A
485B
GND
NC
COM
NO
AUX1
GND
AUX2
BREAK
GND
A
CFAIL
BATFAIL
+12V
GND
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
+12V
GND
D0
D1
RETURN
GLED
RLED
BEEP
HOLD
SHIELD
PWR
RUN
COMM1
COMM2
WLAN
DOOR
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
LAN Connection
Important Notes:
1. Both 10Base-T and 100Base-T are supported
2. This cable distance must be less than 330 ft. (100m)
3. For cable length of more than 330 ft. (100m). Use HUB to amplify the signal.
Figure 23
Figure 24
CAT5e or CAT6 ethernet
cable recommended

20
Atlas x60 Series Access Control Panels Installation Guide
Installation Diagram
Sensor
CEILING
INDOOROUTDOOR
Atlas x60 Access Control Bundle
Electric Lock
Exit Button
Reader for "Out" DoorReader for "In" Door
Figure 25
Ethernet Communication wire
220/110 V Input
Table of contents
Other ZKTeco Control Panel manuals
Popular Control Panel manuals by other brands

Rockwell Automation
Rockwell Automation Allen-Bradley OptixPanel installation instructions

Eclipse
Eclipse ACC970 instruction manual

INIM Electronics
INIM Electronics PREVIDIA MAX manual

Helo
Helo WE-50 User and installation manual

Strong
Strong SM-RBX-EXT-14-WH installation manual

weintek
weintek MT-8080T installation instructions

Grossenbacher Systeme
Grossenbacher Systeme SmartPanel SP-240 Device description

JCM
JCM ROLLER 868 manual

Rehau
Rehau NEA operating instructions

Digital Monitoring Products
Digital Monitoring Products 1912XR installation guide

AERMEC
AERMEC NRA Directions for use

CROW ELECTRONIC ENGINEERING LTD.
CROW ELECTRONIC ENGINEERING LTD. RUNNER 8 Program guide