Zodiac Ei2 Expert User manual

Noce d’installaon et d’ulisaon
Français
Instrucons for installaon and use
English
Montage- und Gebrauchsanleitung
Deutsch
Installae en gebruikshandleiding
Nederlands
Manual de instalación y de uso
Espanõl
Manual de instalação e ulização
Português
Manuale di installazione e di uso
Italiano
More documents on:
www.zodiac-poolcare.com
EN
H0470400.B - 2016/10

1
WARNINGS
GENERAL WARNINGS
• Failure to respect the warnings may cause serious damage to the pool equipment or cause serious injury, even death.
• The appliance is intended for use in swimming pools only and must not be used in applicaon other than that for which it is
designed.
• It is important that the equipment is operated by competent and qualied (both physically and mentally) people who have
previously received the instrucons for use. All persons not meeng these criteria must not approach the appliance in order to
avoid exposure to dangerous elements.
• Keep the appliance out of the reach of children.
• The appliance must be installed in accordance with the manufacturer’s instrucons and respecng current local standards. The
installer is responsible for installaon of the equipment and for compliance with naonal installaon regulaons. Under no
circumstances can the manufacturer be held liable in the event of failure to comply with applicable local standards.
• For other than the simple user-maintenance described in this manual, the product must be serviced by a qualied professional.
• Incorrect installaon and/or use may cause serious damage to property or serious injuries (possibly causing death).
• All equipment, even postage and packing paid, travels at the risks and perils of the recipient. The consignee shall make reservaons
in wring on the carrier’s bill of lading if damage is detected, caused during transport (conrmaon to be sent to the carrier
within 48 hours by registered mail with acknowledgement of receipt). In the event of a device containing coolant that has been
turned on its side, menon your reservaons in wring to the carrier.
• If the appliance suers a malfuncon, do not try to repair the appliance yourself, contact a qualied technician.
• Refer to the warranty condions for details of the permied water balance values for operang the appliance.
• Defeang, eliminang or shunng any of the safety that may be a part of the device automacally voids the warranty, as does the
use of unauthorized, third party replacement parts.
• Do not spray inseccide or any other chemical (inammable or non-inammable) in the direcon of the appliance, as this may
damage the body and cause a re.
• Zodiac® Heat pump, ltraon pump and lter appliances are compable with most commonly used pool water treatment systems.
• For heat pump appliances or dehumidiers, do not touch the fan or insert a rod or your ngers through the grang when the
appliance is in operaon. The fan rotates at high speed and may cause injuries or even death.
WARNINGS ASSOCIATED WITH ELECTRICAL APPLIANCES
• The electrical supply to the appliance must be protected by a dedicated 30 mA dierenal residual current protecon device
(RCD), complying with the standards and regulaons in force in the country where it is installed.
• Before carrying out any operaons, check that:
- The voltage indicated on the rang plate of the appliance corresponds to the mains voltage,
- The power grid is adapted to the power requirements of the appliance, and is grounded.
- The plug (where applicable) is suitable for the socket.
• In the event of abnormal funcon or signs of overheang such as a burning odour from the appliance, turn it of immediately,
unplug it from its power supply and contact a professional.
• Before accessing the enclosure for any reason, ensure that all power to the appliance and also power to any accessories or
external devices which may be connected to the appliance, is disconnected from the mains power supply.
• Do not disconnect and reconnect the appliance to the power supply when in operaon.
• Do not pull on the power cord to disconnect it from the power supply.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied persons in order
to avoid a hazard.
• Do not operate or service the product with wet hands.
• Ensure that all terminals for mains power are free in good condion and free of corrosion and/or dirt/debris.
• For any component or sub-assembly containing a baery: do not recharge or dismantle the baery, or throw it into a re. Do not
expose it to high temperatures or direct sunlight.
• In stormy weather, unplug the appliance to prevent it from suering lightning damage.
• Do not immerse the appliance in water (with the excepon of cleaners) or mud.
Recycling
This symbol means that your appliance must not be thrown into a normal bin. It will be selecvely collected for the
purpose of reuse, recycling or transformaon. Any substances it may contain which are potenally dangerous to the
environment shall be eliminated or neutralised.
Request informaon on recycling procedures from your retailer.

2
Contents
1. Informaon before installaon .............................................................................. 3
1.1 Contents............................................................................................................................................. 3
1.2 Technical specicaons...................................................................................................................... 3
2. Installaon............................................................................................................. 4
2.1 Preparing the pool: water balance ....................................................................................................4
2.2 Installing the control box ...................................................................................................................4
2.3 Installing the cell................................................................................................................................ 4
2.4 Installing the ow controller (Ei² Expert only) ................................................................................... 5
2.5 Electric connecons........................................................................................................................... 6
3. Use ........................................................................................................................ 7
3.1 Descripon of the Ei² - GenSalt OE user interface ............................................................................ 7
3.2 Descripon of the Ei² Expert user interface.......................................................................................7
4. Maintenance........................................................................................................ 11
4.1 Washing the pool lter (backwash) .................................................................................................11
4.2 Cleaning the electrode..................................................................................................................... 11
4.3 Winterizing....................................................................................................................................... 11
5. Troubleshoong................................................................................................... 12
6. Product conformity.............................................................................................. 12
• Before you do anything with the device, it is vital that you read this installaon and user manual, as well
as the "warnings and warranty" booklet delivered with the device. Failure to do so may result in material
damage or serious or fatal injury and will invalidate the warranty.
• Save these instrucons for future reference for service and maintenance.
• It is prohibited to distribute or modify this document in any way without authorisaon from Zodiac®.
• Zodiac® is constantly developing its products to improve their quality; therefore, the informaon contained
in this document may be modied without noce.
EN

3
1. Informaon before installaon
1.1 Contents
Ei² - GenSalt OE
Control box Cell Installaon kit
Ei² Expert
Control box Cell Installaon kit Fixture collar kit
1.2 Technical specicaons
Power supply voltage 230 Vac-50 Hz
Electric power Max. 140 W
Protecon index IPX5
Box size (l x h x d) 28.5 x 40.5 x 12.5 cm
Cell size (l x h x d) 16.5 x 22.5 x 12.5 cm
Weight (box + cell) 6.0 kg (+/- 500 g depending on model)
Minimum Maximum
Flow through the cell 5 m³/h 18 m³/h - ND 50 mm
25 m³/h - ND 63 mm
Pressure in the cell /2.75 bar
Operang water temperature 5 °C 40 °C

4
2. Installaon
2.1 Preparing the pool: water balance
These appliances are designed to disinfect pool water using its salt water chlorinaon funcon.
It is essenal that the pool water balance and salinity are controlled and adjusted before the appliance is installed. Making
sure that those parameters are correct from the very start will reduce the likelihood of encountering problems on the rst
days of operaon or during the season the pool is in use.
Even though it is an autonomous system, it is essenal to regularly analyse the water to check the water balance
parameters and adjust them if necessary.
Unit Recommended
values To increase To decrease Test frequency
(during season)
pH /7.2 – 7.4 Add pH+ or use
automac regulaon
Add pH- or use
automac regulaon Weekly
Free
chlorine
mg/L or
ppm 0.5 – 2
Increase the chlorine
producon or use Boost
mode (Ei² Expert only)
Reduce chlorine
producon Weekly
TAC
(alkalinity or
buering power)
°f
(ppm)
8 – 15
(80 – 150)
Add alkaline corrector
(Alca+ or TAC+) Add hydrochloric acid Monthly
HL
(level of calcium
carbonate)
°f
(ppm)
10 – 30
(100 – 300) Add calcium chloride
Add a calcium carbonate
sequestering agent
(Calci-) or carry out
carbonate removal
Monthly
Cyanuric
acid
(stabiliser)
mg/L or
ppm < 30 Only add cyanuric acid if
necessary (Chlor Stab)
Parally empty the pool
and rell it Quarterly
Salinity g/L or
kg/m³ 4Add salt
Leave as such or
parally empty the pool
and rell it
Quarterly
Metals
(Cu, Fe, Mn…)
mg/L or
ppm ± 0 /Add metal binder (Metal
Free) Quarterly
2.2 Installing the control box
• The control box must be installed in a dry venlated equipment room protected against frost, with no pool maintenance
products stored nearby.
• The control box must be installed a minimum of 2.0m from the surrounding edge of the pool. Any addional local
installaon codes in the installaon country must also be adhered to.
• It must not be installed more than 1.5 metres from the cell (maximum cable length).
• If the box is xed to a post, a waterght panel must be xed behind the control box (350x400 mm minimum).
• Fix the support solidly to the wall or the waterght panel, and place the control box on it using the screws provided.
2.3 Installing the cell
Ei² - GenSalt OE Ei² Expert
EN

5
• The cell must be installed on the piping aer the ltering, aer any measurement sensors, and aer eventual heang systems.
• The cell must be installed on a horizontal pipe to ensure an essenally horizontal ow of water through it, with no more than a 30
deg angle/slope. The pipe must have a free horizontal length of at least 30cm on which the cell will be installed. The cell must also
be installed as far away as possible from any bends or elbows in the plumbing (1).
• Ensure that the direcon of ow of water through the cell is in accordance with the arrows marked on the cell (see arrows (2)).
• Dismantle the cell.
• Posion the lower collar of the cell (3) upside down at the posion where the pipe will be installed.
• Use a drill bit or centre-punch to mark the posions of the holes to be drilled on the pipe (4), remove the lower collar and drill the
holes using the hole saw supplied.
• Check that the edges are perfectly smooth and deburred (use abrasive paper, for example).
• Clip together the lower and upper parts of the cell collar on the pipe at the holes, respecng the water ow direcon (use the "EU"
Ø50 reducer for a Ø50 mm pipe).
• Posion the top transparent part of the cell (presence of a foolproof locang notch), posion the locking ring on the
thread of the upper collar, then ghten rmly by hand (do not use a tool).
• Connect the cell power supply cable in compliance with the wire colour codes (red, black and blue connectors) and then
t the protecve cap.
• Pour les modèles Ei² 12, GenSalt OE 10 ou Ei² Expert 10, le deuxième connecteur rouge ne sera pas branché ; le laisser
tel quel avant de mere le cache de protecon.
• The cell must always be the last element placed on the pool return pipe (see diagram).
• It is always recommended to install the cell on a by-pass. This assembly is MANDATORY if the ow is in
excess of 18 m³/hour to avoid load loss.
• If you installed the cell on a by-pass, it is recommended to t a check valve downstream from the cell
instead of a manual valve, to avoid the risk of an improper seng which could result in the incorrect ow
water back into the cell.
• Failure to locate and orient the cell in strict accordance with these instrucons can result in a hazardous
buildup of pressurized gas which can result in serious property damage and serious injury, including loss of
life.
An "AUS" reducer and a black seal are supplied in the installaon kit. They are intended for 1 1/2" (= 38 mm)
pipes. However, the black seal can be used instead of the original seal if the pipe is not standardised (diameter
smaller than ND 50 or ND 63).
2.4 Installing the ow controller (Ei² Expert only)
The ow controller and its xture collar (Ø50 mm) must imperavely be installed on the piping close to the cell and
upstream from it. Use the threaded adapter and Teon tape supplied to install the ow controller on its xture collar.
• Cell installed in by-pass: the ow controller must be installed on the cell by-pass between the upstream isolaon valve
and the cell itself.
• Cell installed in line: the ow controller must be installed just in front of the cell and aer a possible valve.
• Fixer le contrôleur de débit en ulisant uniquement l’écrou de serrage.
Écrou de
serrage
• Failure to comply with these instrucons could lead to the destrucon of the cell! The manufacturer cannot
be held liable in this case.
• The ow detector has a direcon for installaon (arrow indicated on it showing the ow direcon
for the water). Make sure that is is correctly placed on its xture collar so that it stops the salt water
chlorinator producon when ltering is stopped ("No ow" displayed showing the absence of ow, see "5.
Troubleshoong").

6
2.5 Electric connecons
2.5.1 Connecng the control box
The salt water chlorinator can be connected in compliance with the applicable standards in the country of installaon.
Ei² - GenSalt OE :
• Mandatory connecon: directly interlocked with the pool ltraon pump (the appliance is only supplied with power
when the pool ltraon pump is operang).
Ei² Expert:
• Preferred connecon: the appliance is permanently connected (hard-wired) to the power supply (power supply
protected by a 30 mA ground fault circuit breaker).
• Possible connecon: directly coupled to the pool ltering (the appliance is only supplied with power when ltering is
operang).
==> When all connecons (electrical and hydraulic) have been made, reconnect (turn on) the mains power supply to
power on the appliance.
• Failure to comply with these instrucons could lead to the destrucon of the cell! The manufacturer cannot
be held liable in this case.
• Whichever connecon is used, it is mandatory to programme the Ei² Expert operang mes (called "Timers")
(see "3.2.5 "Summer" and "Winter" modes and seng the "Timers"").
2.5.2 Connecon to an electric pool cover (Ei² Expert only)
If the pool is ed with an electric roll-on electric pool cover, it can be connected to the Ei² Expert chlorinator using a
dry contact so that the laer automacally adapts its chlorine producon when the electric pool cover is closed (see "").
• Make sure the appliance is powered o and disconnected (e.g., by turning o the circuit breaker or disconnect switch)
from the mains source of power.
• Remove the 12 screws securing the cover screws and remove it (take care not to tear out the ribbon cables).
• Unscrew the dedicated cable gland ghtening ring (at the boom of the control box) and remove the plug to feed
through the cable from the electric pool cover. Tighten the cable gland ghtening ring.
• Connect the cable from the electric pool cover on the "POOL+" and "POOL-" connectors on the electronic board.
• Close the box respecng the ghtening order shown on the following diagram (9 long screws for the perimeter of the
box and 3 short screws for the boom of the box). The box IPX5 protecon index cannot be guaranteed if this procedure
is not followed.
Ei² Expert connecons Torque = 1.2 N.m (= 12.2 kg.cm)
Ei²
GenSalt OE
Ei²
Expert
Ei²
GenSalt OE
Ei²
Expert
AMains power supply 220-240 Vac / 50 Hz X X EConnecon of ow detector X
BCell power supply X X FRibbon cables at the user interface X (1) X (2)
CMemory baery type CR2032 X X GTransformer connecons X X
DCover connecon (contact closed = cover closed) XHFuse 2.5 A me-delayed X X
EN

7
• The Ei² Expert chlorinator is compable with several dierent types of electric pool cover. However, certain
systems may not be compable. In this case, acvate "Low" mode manually from the chlorinator control panel
(see "").
• Refer to the electric pool cover manufacturer's installaon manual.
• The dry contact operang principle is as follows: contact closed = electric pool cover closed.
3. Use
3.1 Descripon of the Ei² - GenSalt OE user interface
Increase or reducon the chlorine producon:
20 %
40 % 60 % 80 %
100 %
- Acvate / deacvate the chlorine producon by a short press.
- Switch o the device with a long press (5 seconds).
- Switch on the device with a short press.
FLOW Red indicator showing the absence of ow and/or presence of air in the cell.
SALT Orange indicator showing a water conducvity problem (not enough salt,
water too cold, etc.).
3.2 Descripon of the Ei² Expert user interface
- Exit the user menu or the internal sengs menu.
- Deacvate Boost mode or Low mode.
- From the home screen: increase or decrease in chlorine producon.
- In the user menu: value changes when a choice is proposed (ashing
characters).
- Simultaneous press for 5 seconds: access the internal sengs menu.
- Access to user menu and navigaon in the sengs (with successive
presses)
- Acvate/deacvate the chlorine producon by a short press.
- Switch o the device with a long press
- Switch on the device with a short press
and - Acvate Boost mode
and - Acvate "Low" mode manually
If the language displayed on the screen when the Ei² Expert is rst switched on is not appropriate, see "3.2.6
"Internal sengs" menu".

8
3.2.1 Chlorine producon acvated
When chlorine producon starts, the "Start..." message is displayed on screen for about 6 seconds. "CHLORINATION" is
then displayed, indicang that the device is producing chlorine.
3.2.2 "Boost" mode: chlorine producon increased to 100 % for 24 h
In certain cases the pool may need higher than normal chlorinaon (stormy weather, high number of bathers, etc.).
"Boost" mode is used to increase chlorine level quickly.
• Press buons and simultaneously: "BOOST" is displayed on the screen and 100 % chlorine producon
starts.
• To stop "Boost" mode, press .
When "Boost" mode is acvated, the rated chlorine producon sengs are temporarily overridden and the Ei²
Expert chlorinator will operate for a total of 24 hours at 100 % chlorine producon. The number of days will
therefore depend on the Ei² Expert operang mes (see "3.2.5 "Summer" and "Winter" modes and seng the
"Timers"").
3.2.3 "Low" mode: chlorine producon reduced to 10 % if the pool is covered
If the pool has a covering system (shelter, electric pool cover, etc.), "Low" mode is designed to adapt the chlorine
producon to situaons where the pool is covered (lower needs). Its eect is to limit chlorine producon to 10%.
This mode is also called " electric pool cover" mode.
Manual acvaon (shelter, cover, etc.) :
• Press buons and simultaneously: "LOW" is displayed on the screen and chlorine producon is reduced
to 10 %.
• To stop "Low" mode, press .
Automac acvaon (compable electric pool cover):
• Make sure that the electric pool cover is compable and connected to the Ei² Expert chlorinator (see "").
• «Low» mode will automacally be acvated when the electric pool cover is closed.
• "Low" mode will stop as soon as the electric pool cover is completely open.
3.2.4 Seng the me
The Ei² Expert chlorinator is ed with an internal memory. When the device is rst switched on it is important
to leave it powered on connuously for at least 24 hours in order to inially charge the accumulator (permanent
separate power supply or ltering on permanently). Once charged the accumulator has several weeks of
autonomy in the event of a power failure.
The me is displayed in a 24 hour format.
• Switch on the device and wait unl screen start-up sequence is nished.
• Press the buon to access the user menu, the minutes start to ash.
• Use the and buons to set the minutes, then press to store.
• Use the and buons to set the hours, then press to store.
• Press the buon to return to the home screen.
EN

9
3.2.5 "Summer" and "Winter" modes and seng the "Timers"
"Timer" programming is used to dene the device operang mes within the ltering system operaon mes.
The daily operang mes must be sucient to correctly treat the water. Ei² Expert proposes default sengs of
Timers 1 and 2. They can be customised (see "3.2.5.b Programming the mers according to the modes").
A reminder of the calculaon rule: the ideal daily ltering me is obtained by dividing the required pool water
temperature (measured in °C) by 2.
Example: for water at 28 °C, me = 28/2 = 14 hours per day
The Ei² Expert chlorinator can store 2 seasonal operang modes called by default "Sum" and "Win". The following
sengs can be customised for each mode:
- the device operang mes, the "mers": T1 (Timer 1) and T2 (Timer 2)
- the required chlorine producon rate: 10 %, 20 %, 30 %,... up to 100 %.
STANDBY = Device operang status
T = "Timer" mode (always acve)
SUM = "Summer" operang mode
80 % = chlorine producon rate
14:25 = me in 24 h format
3.2.5.a Mode selecon: "SUMMER" or "WINTER"
• Press 4 mes to set the clock. "SUM" starts to ash.
• Use the and buons to choose "SUM" or "WIN" mode, then press the buon to return the home
screen.
3.2.5.b Programming the mers according to the modes
The mes of Timers 1 and 2 cannot overlap. In addion, the me range of Timer 1 necessarily precedes that of
Timer 2.
TE1 / TE2 = Timer in "summer" mode No. 1 / Timer in "summer" mode No. 2
08:00-12:00 = Operang me range of Timer No. 1
14:00-18:00 = Operang me range of Timer No. 2
• Press 4 mes to set the clock. "SUM" starts to ash.
• Select the mode to be customised "SUM" or "WIN" using the and buons, then press to store and
move to the mer seng screen.
• Use the and buons to set the Timer 1 stop minutes, then press to store.
• Use the and buons to set the Timer 1 stop hours, then press to store.
• Use the and buons to set the Timer 1 start minutes, then press to store.
• Use the and buons to set the Timer 1 start hours, then press to store.
• Repeat the steps for Timer 2.
• Press the buon to store the mers and move to seng the chlorine producon rate.
• Use the and buons to choose the required chlorine producon rate (from 10 % to 100 %).

10
3.2.6 "Internal sengs" menu
Ei² Expert has an "Internal sengs" menu to change and/or view the following operang parameters:
• Language
• Polarity inversion cycles
• Operang hours counter
To access this menu, press the and buons simultaneously for 5 seconds.
EMEA: Device sale and use region (not modiable)
FR French: Language used (modiable, by default = French)
Cyc=5h: Polarity inversion cycle (modiable, by default = 5 h)
00000: Operang hours counter (not modiable)
3.2.6.a Seng the language
By default the Ei² Expert chlorinator is set to display in French. 13 languages are available: French, English, Spanish,
Italian, Swedish, German, Portuguese, Dutch, Afrikaans, Czech, Hungarian, Slovakian and Turkish.
• From the home screen, press the and buons for 5 seconds. The current language starts to ash.
• Use the and buons to select the required language.
• Press the buon to return to the home screen.
3.2.6.b Polarity inversion
The choice of polarity inversion cycles may aect the cell lifeme (+/- 15 %). Ask your professional reseller for
advice in case of doubt.
The electrolyc cell is equipped with a smart polarity inversion system designed to prevent the electrode plates
from scaling. However cleaning may be required in regions where the water is very hard. (default seng = 5
hours).
Ei² Expert oers a choice of 3 inversion cycles:
• 3 hours: for water of high carbonate content (TH > 40 °f or 400 ppm)
• 5 hours: for normal water (20 °f < TH < 40 °f or 200 ppm < TH < 400 ppm)
• 7 hours: for water of low carbonate content (TH < 20 °f or 200 ppm).
• From the home screen, press the and buons for 5 seconds.
• Press the buon. The polarity inversion cycle hours start to ash.
• Use the and buons to select the required cycle.
• Press the buon to return to the home screen.
EN

11
3.2.6.c Operang hours counter
Ei² Expert can count its total operang hours (= chlorine producon me, aché en jours). This informaon
may be useful to determine the electrode age. The value is provided for informaon only and may be modied.
• From the home screen, press the and buons for 5 seconds.
• The number of operang hours is displayed at the boom right of the screen.
• Press the buon to return to the home screen.
4. Maintenance
4.1 Washing the pool lter (backwash)
L’appareil doit impéravement être éteint lors des procédures de lavage de ltre. When the device is on
(ltraon on), press the buon for 5 seconds to switch it o.
Aer cleaning the lter, switch the device on again by pressing the buon (short press). It will resume
normal operaon (producon slaved to ltraon for Ei² and GenSalt OE.
Pour Ei² Expert la producon fonconnera selon le réglage des mers.
The manufacturer cannot be held liable in case of incorrect handling.
4.2 Cleaning the electrode
The electrolyser is equipped with a smart polarity inversion system designed to prevent the electrode plates from
scaling. However cleaning may be required in regions where the water is very hard. (default seng = 5 hours).
• Turn o the chlorinator and the ltering, close the isolaon valves, remove the protecon cover and disconnect the cell
power cable.
• Unscrew the ghtening ring and remove the cell. The ring is notched thus allowing a lever to be used in the event of it
jamming. Place the cell backwards and ll it with a cleaning soluon so that the electrode plates are immersed.
• Leave the cleaning soluon to dissolve the scale deposit for about 15 minutes. Dispose of the cleaning soluon at an
approved waste recycling site, never pour into the rainwater drainage system or into the sewers.
• Rinse the electrode using clean water and put it back on the cell xture collar (there is an alignment foolproofer).
• Ret the ghtening ring, reconnect the cell cable and ret the protecve cover. Open the isolaon valves and restart
the ltering and chlorinator.
• If you do not use a commercially available cleaning soluon, you can manufacture it yourself by carefully
mixing 1 volume of hydrochloric acid with 9 volumes of water (Warning: always pour the acid into the water
and not the opposite and wear suitable protecve equipment!).
• Make sure that the seng of the polarity inversion cycles is adapted to the pool water hardness. See "3.2.6.b
Polarity inversion" to change them.
4.3 Winterizing
The chlorinator has a protecve system to limit chlorine producon under poor operang condions such as cold
water (winter) or a lack of salt.
• Acve winterizing = ltering operaonal in winter: below 10 °C it is preferable to switch o the chlorinator. Above this
temperature you can leave it running.
• Passive winterizing = lower water level and drained piping: leave the electrode dry in its cell with its isolaon valves
open.

12
5. Troubleshoong
Ei²
GenSalt OE Ei²Expert Possible causes Soluons
«FLASH»
INVERSION The self-cleaning cycle is automac;
this message is not an error code
but an informaon message.
• Wait for about 10 minutes and chlorine
producon will resume automacally at
the previously set level.
/ HIGH SALT • Salt overload (> 10 g/L). • Drain the pool parally to reduce the salt
concentraon.
"Salt" indicator
on
CHECK SALT • Lack of salt (< 3g/L) due to water
loss or diluon (lter backwash,
water renewal, rain, leaks, etc.).
• Pool water temperature too low
(< 18 °C, variable).
• Cell scaled up or worn.
• Add salt to the pool to keep the level at
4 g/l. If you do not know the salt level or
how to test it, consult your reseller.
• Basic producon limitaon signal when
the water is too cold. Reduce chlorine
producon or add salt to compensate.
• Clean or replace the cell.
"Flow" indicator
on
NO FLOW • Stop or failure of the ltering
pump.
• Presence of air or gas in the cell
(incorrect lling with water).
• By-pass valves closed.
• Flow controller and/or cell
disconnected or defecve.
• Check the pump and its programming
clock, the lter, the skimmer(s), and the by-
pass valves. Clean them if necessary.
• Check the cable connecons (cell and ow
controller).
• Check that the ow controller is working
correctly (replace it if necessary).
/
PUMP
CONTROLLER
• This message is displayed
alternately with "NO FLOW" if
the situaon connues.
• Perform the same checks as above.
/
OUTPUT
FAULT
• Short-circuit in the cell or cable
disconnected/badly connected.
• Worn electrode.
• Important manque de sel, ou pas
de sel.
• Sel non encore susamment
dilué.
• Check the cell connecons.
• Replace the cell.
• Have the control box (electronic board
and transformer) checked by a qualied
technician if necessary.
• Ajouter du sel dans la piscine pour
maintenir un niveau à 4 g/L.
/
OVERHEAT-
ING
• Device internal temperature
over 70 °C.
• Device internal temperature
over 80 °C.
• The device reduces its producon to 50 %.
• Producon stops.
• Producon restarts automacally when the
temperature drops.
/
Loss of
me
seng
• The accumulator is worn or
defecve.
• Check the condion of the accumulator.
• Replace it if necessary (3 V accumulator,
type "CR2032"), see "" to open and close
the box.
==> If the problem continues contact your reseller
6. Product conformity
This appliance has been designed and manufactured to comply with the applicable requirements of the following stand-
ards :
EN6000-6-1: 2006
EN6000-6-3: 2007
IEC 60335-1
Relative to which it is compliant. The product has been tested under the intended normal conditions of use.
EN

Pour plus de renseignements, merci de contacter votre revendeur.
For further informaon, please contact your retailer.
ZODIAC® is a registered trademark of Zodiac Internaonal, S.A.S.U., used under license.
Votre revendeur / your retailer
www.zodiac-poolcare.com
Zodiac Pool Care Europe - BP 90023 - 49180 St Barthélémy d’Anjou cedex - S.A.S.U. au capital de 1 267 140 € / SIREN 395 068 679 / RCS PARIS
Other manuals for Ei2 Expert
3
This manual suits for next models
1
Table of contents
Other Zodiac Control Unit manuals

Zodiac
Zodiac PRO User manual

Zodiac
Zodiac Jandy AquaLink RS R04685 Series User manual

Zodiac
Zodiac Jandy Pro Series NeverLube User manual

Zodiac
Zodiac TRi pH Module User manual

Zodiac
Zodiac Jandy Pro Series User manual

Zodiac
Zodiac Jandy Pro Series JXi R0589700 User manual

Zodiac
Zodiac Jandy Pro Series User manual
Popular Control Unit manuals by other brands

Fukuda Denshi
Fukuda Denshi HR-800 Service manual

Edwards
Edwards CTM Installation sheet

FutureSmart
FutureSmart MDAD8-6 installation guide

GRASS VALLEY
GRASS VALLEY KAMELEON Series instruction manual

National Instruments
National Instruments FlexRIO PXIe-79 R Series installation guide

Alemite
Alemite 3685-A Service guide