❺ Troubleshoo ng
• Before you contact your reseller, please carry out these few simple checks using the following
tables if a problem occurs.
• If the problem con nues contact your reseller.
• : Ac ons reserved for a qualifi ed technician
5.1 I Device behaviour
The device does
not start hea ng
straight away
• On start-up, the device remains "paused" for 5 minutes before it starts opera ng.
• When the setpoint temperature is reached, the heat pump stops hea ng: the water temperature
is higher than or equal to the setpoint temperature.
• When the water fl ow rate is zero or is not enough, the heat pump stops: check that the water is
circula ng correctly in the heat pump and that the hydraulic connec ons are correct.
• The heat pump stops when the outdoor temperature falls below 7 °C.
• It may be that the heat pump has detected an opera ng fault (see § “5.2 I Error code display”).
• If you have checked these points and the problem persists: contact your reseller.
The device is
draining water
• O en called condensa on, this water is the moisture contained in the air which condenses
on contact with certain cold mechanisms in the heat pump, especially on the evaporator. The
more damp the air, the more condensa on your heat pump will produce (your device may
drain several litres of water per day). This water is retrieved by the base of the heat pump and
drained through a hole.
• To check that the water is not coming from a leak in the pool circuit on the heat pump, shut
down the heat pump, wait a few minutes and run the fi ltra on pump for the water to circulate
in the heat pump. If the water con nues to fl ow through the condensa on drain, there is a
water leak in the heat pump; contact your reseller.
The evaporator is
iced over
• Your heat pump will soon switch to its defrost cycle to melt the ice.
• If your heat pump cannot manage to deice its evaporator, it will stop itself; this means that the
outdoor temperature is too low (below 7°C).
The device is not
working
• If there is no display, check the supply voltage and the F1 fuse.
• When the setpoint temperature is reached, the heat pump stops hea ng: the water temperature
is higher than or equal to the setpoint temperature.
• When the water fl ow rate is zero or is not enough, the heat pump stops: check that the water
is circula ng correctly in the heat pump.
• The heat pump stops when the outdoor temperature falls below 7 °C.
• It may be that the heat pump has detected an opera ng fault (see § “5.2 I Error code display”).
The device is
working but
the water
temperature does
not increase
• It may be that the heat pump has detected an opera ng fault (see § “5.2 I Error code display”).
• Check that the automa c fi lling valve is not stuck in open posi on; this will keep supplying cold
water into the pool and will prevent the temperature from rising.
• There is too much heat loss as the air is cool. Install a heat insulated cover on your pool.
• The heat pump is unable to capture enough calories as its evaporator is clogged with dirt. Clean
it to restore its performances (see § “4.2 I Maintenance”).
• Check that the external environment is not hindering the heat pump (see § “❷ Installa on”).
•
Check that the external environment is not hindering the heat pump (see § “❷ Installa on”).
Check that the heat pump is the right size for this pool and its environment.
The ven lator is
running but the
compressor stops
from me to me
with no error
message
• If the outdoor temperature is low, the heat pump will perform defrost cycles.
• The heat pump is unable to capture enough calories as its evaporator is clogged with dirt. Clean
it to restore its performances (see § “4.2 I Maintenance”).
The device trips
the circuit breaker
• Check that the circuit breaker is correctly dimensioned and that the cable sec on used is
the right one (see § “1.2 I Technical specifi ca ons”).
• The supply voltage is too low; contact your electricity supplier.