H0430700.A - EN - 2014-05 4
EN
Follow the hydraulic connecon direcon (see § «Dimensions» in the appendix).
The piping must be supported.
• Connecon must use Ø50 PVC rigid pressure piping, from a bypass, on the pool lter circuit, aer the lter and before
water treatment.
• Installing a by-pass is mandatory and facilitates operaons on the appliance.
• Make sure the hydraulic ngs are correctly ghtened and that there are no leaks.
Condensate drainage: warning, your appliance can release several litres
of water per day; it is highly recommended to connect the drainage to the
drains.
Connect an interior Ø18 pipe (not supplied), to the corrugated angle to be
ed under the appliance base (orientable outlet).
1.5 Electric connecons
1.5.1 Voltage and protecon
• the heat pump’s power supply must come from a protecon and cut-o device (not included) which is compliant with
the country’s applicable standards and regulaons,
• addional protecon may be required on installaon to guarantee power surge category II,
• the machine is designed to be connected to a power supply using a neutral TT and TN.S wiring system,
• electric protecon: using a circuit breaker (D curve) or a fuse (calibre 16A see § 1.1), with a separate 30 mA ground fault
circuit breaker (circuit breaker or switch).
• the electricity supply connecon ducng must be stac,
• acceptable voltage variaon: ± 6% (when running),
• use cables suitable for outside use of the H07RN-F type, and of an outer diameter included between 9 and 18
mm,
• use the cable gland to pass the power supply cable into the appliance.
1.5.2 Connecons
• The electric power supply cable must be isolated from all sharp or hot elements that could damage or crush it.
• With the power o, check that the power cable is properly connected to the connecon terminal
• Loose terminals can cause the terminal block to heat and lead to the warranty being voided.
• It is imperave to connect the appliance to an earth rod.
• Risk of electric shocks inside the appliance.
• Only a qualied and experienced technician is authorised to wire inside the appliance.
• If the power supply cable is damaged it should be replaced by a qualied technician.
1.5.3 Remote control panel
The heat pump control panel can be installed at a distance from the appliance. To do this, use the remote control kit
(plasc cover + metal holder + RJ11/RJ45 cable extension, see kit instrucon to install).
1.5.4 Connecng opons
• use cables with a cross secon of: 2x0.75 mm² at least, of the H07RN-F type, and of an outer diameter included between
8 and 13 mm
Remove the cover (above the cable gland) and install the supplied cable gland to pass the cabling into the
appliance. The opons cables and the power supply cable must be supported separately (risk of interference)
using a cable e inside the appliance just aer the cable glands.
Any incorrect connecons to terminals 1 to 12 may damage the regulator and void its warranty.
The ltering pump motor should not, under any circumstances, be directly supplied from terminals 11-12.
If there is any intervenon on terminals 1 to 12 there is a risk of electric current being returned.
phase (L) + neutral (N) + Ground ( )