2
WARNINGS
This manual contains only basic informaon on the safety measures to be adopted during
installaon, maintenance and start-up. The complete manual can be read and downloaded
as a PDF le from the website: www.zodiac.com. All assembly, electrical installaon and
maintenance work must be carried out by qualied, authorized personnel who have read
this manual carefully and completely. We reserve the right to totally or parally change our
products’ features or the content of this document without prior warning.
GENERAL WARNINGS
• The appliance is intended to be used for pools and spas for a specic purpose; it must not be used for any purpose
other than that for which it was designed.
• Failure to respect the warnings may cause serious damage to the pool equipment or cause serious injury, even
death.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilies, or lack of experience and knowledge, unless they have been given supervision or instrucon concerning
use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do
not play with the appliance.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory
or mental capabilies or lack of experience and knowledge if they have been given supervision or instrucon
concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without supervision.
• The appliance must be installed according to the manufacturer’s instrucons and in compliance with local and
naonal regulaons.
• Our products may only be assembled and installed in pools compliant with standards IEC/HD 60364-7-702 and
required naonal rules. The installaon should follow standard IEC/HD 60364-7-702 and required naonal rules for
swimming pools. Consult your local dealer for more informaon.
WARNINGS ASSOCIATED WITH ELECTRICAL APPLIANCES
• The power supply to the appliance must be protected by a dedicated 30mA Residual Current Device (RCD), complying
with the standards and regulaons in force in the country in which it is installed.
• The equipment not include electrical switch for disconnecon; include a disconnecon supply device in the xing
wiring at least OVC III, in accordance applicable naonal laws.
• If the power supply cord is damaged, it must be replaced by the manufacturer, an authorized representave or a
repair facility only.
WARNINGS CONCERNING APPLIANCES CONTAINING R32 REFRIGERANT
• This device contains R32 refrigerant, a class A2L refrigerant, which is considered to be potenally ammable.
• Do not discharge R32 uid into the atmosphere. This is a uorinated greenhouse gas, covered by the Kyoto Protocol,
with a Global Warming Potenal (GWP) = 675 (European regulaon EU 517/2014).
• In order to comply with the applicable standards and regulaons in terms of the environment and installaon, in
parcular Decree No. 2015-1790 and/or European regulaon EU 517/2014, a leak test must be performed on the
cooling circuit when the appliance is rst started and at least once a year. This operaon must be carried out by a
specialist cered to test cooling appliances
• The appliance shall be stored in a room without connuously operang ignion sources (for example: open ames,
an operang gas appliance or an operang electric heater).
• For further informaon consult the safety instrucons concerning appliances containing gas R32 in the extended
version of the manual, in which the elds area check, work procedure, general work area, check for the presence
of refrigerant, check for the presence of a re exnguisher, no source of ignion, area venlaon, refrigerant
equipment check, electrical component check, repair of insulated components, repair of intrinsically components,
wiring, detecon of ammable refrigerant, removal and discharge, loading procedures and dismantling are specied.
INSTALLATION AND MAINTENANCE
• Only a person qualied in the technical elds concerned (electricity, hydraulics or refrigeraon) is authorized to
carry out installaon, maintenance or repair work on the appliance
• The appliance may not be installed close to combusble materials, or the air duct inlet of an adjacent building.
• When servicing the appliance, the composion and state of the heat transfer uid must be checked, as well as the
absence of any traces of coolant.
• During the appliance’s annual sealing test in accordance with applicable legislaon, the high and low pressure
switches must be checked to ensure that they are securely fastened to the cooling circuit and that they cut o the
electrical circuit when tripped.
• During maintenance work, ensure there are no traces of corrosion or oil around the cooling components.
• Before beginning work on the cooling circuit, stop the appliance and wait for a few minutes before ng the
temperature and pressure sensors. Some elements such as the compressor and piping may reach temperatures in
excess of 100°C and high pressures with the consequent risk of severe burns.