The thermometer is a non-contact infrared
thermometer, also with Probe thermometer. You
can select only one Mode at the same time but
can change the Mode at will. Please remember to
keep away from baby and children and don’t use it
for safety related applications.
* Special Features:
1. HACCP Zone Display;
2. Splash Proof (IP65)
In Non-contact Infrared Thermometer function (IRT Mode)
# The white light will automatically turns on while the Scan button is pressed.
Simply aim the thermometer at the measure target with “Infrared Lens”
and press Scan (infrared) key to display the surface temperature. The
distance to target ratio is 2.5:1 therefore the thermometer should be
positioned as close to the target as possible.
While scanning, the newest temperature will be updated on the LCD and the measurement will continue as long as
the Scan (infrared) key is depressed. When the Scan (infrared) key is released, icon “Hold” will appear on the display
and the last measurement will remain visible for 15 seconds before the display goes blank.
Mode Selection MIN ÆMAX ÆLOCK ÆoC/ oF ÆEMIS
MINIMUM OR MAXIMUM MODE
The thermometer will display the minimum or maximum reading during the measurement period only until the Mode
key is pressed.
To utilize the minimum mode, please press Scan (infrared) key ÆMode key ÆScan (infrared) key. And keep
pressing Scan (infrared) key for measurement.
To utilize the maximum mode, please press Scan (infrared) key ÆMode key *twiceÆScan (infrared) key. And keep
pressing Scan (infrared) key for measurement.
LOCK MODE
The lock mode is particularly useful for continuous monitoring of temperatures. The thermometer will continuously
display the temperature for up to 60 minutes or until the Scan (infrared) key button is pressed.
To utilize the lock mode, please press Scan (infrared) key ÆMode key *three timesÆScan (infrared) key.
oC OR oF MODE
To change the ‘oC’ or ‘oF’ mode, please press Scan (infrared) key ÆMode key *four timesÆScan (infrared) key.
Same steps can be taken when switching from oF to oC.
EMISSIVITY
The infrared thermometer is supplied with a default emissivity of 0.95. The emissivity can be changed from 0.10 (10E)
to 1 (100E). Changes should only be carried out by experienced personnel. For information relating to the emissivity
of specific materials, please contact the nearest retailer. Note: non-contact infrared thermometers are not
recommended for use in measuring the temperature of shiny or polished metals.
To change the emissivity, please Scan (infrared) key ÆMode key *five timesÆScan (infrared) key for each 0.01
(1E) adjustmentÆMode key.
In Contact Thermocouple Probe function (COT Mode)
Attach the thermometer at the measure target with “Probe” and press Probe key to continuously display the
temperature for up to 4 minutes. After that the device will automatically shut off to extend the battery life. Press Probe
key will interrupt the scanning to display the last temperature with a 'Hold' wording. To reenter scanning just press
Probe key again.
1. Do not twist the probe and rotate the probe in wrong direction.
2. Over stress on probe may cause break.
3. After measure high temp, the probe may remain HOT for a while.
4. Probe is dangerous for human when the probe is in an open position. Remember to hold the probe back
when not in use.
The probe of contact thermometer may be damaged if exceeding the specification of measurement
temperature range.
To avoid electric shock and thermometer damage, do not measure live circuit where voltage exceeding
24V AC RMS or 60V DC with the thermocouple probe.
HACCP check
The “HACCP CHECK” feature is incorporated in our thermometer
temperature to graphically indicate critical temperature zone. The icons
and LED indicators located above the display indicate a food product
stays in a safe or unsafe HACCP “ Danger Zone” temperature. The
green and red LED light will always be lit before power off.
A Green LED appears with icon ” ” indicates a safe cool or frozen
condition below 4oC(40oF) or appears with icon ” ” indicates a safe
holding temperature above 60oC(140oF).
When temperature is between 4oC and 60oC, the red LED with icon ”
” will appear and indicate that the temperature is fallen within the
HACCP “Danger Zone” from 4oC to 60oC (40~140oF).
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
「」「 」
‘Hi’ or ’Lo’ is displayed when the temperature being measured is outside of the
measurement range.
「 」「 」
‘Er2’ is displayed when the thermometer is exposed to rapid changes in the
ambient temperature. ‘Er3’ is displayed when the ambient temperature exceeds
0oC (32oF) or +50 oC (122 oF). The thermometer should be allowed plenty of time
(minimum 30 minutes) to stabilize to the working/room temperature.
「」
For all other error messages it is necessary to reset the thermometer. To reset it, waiting for auto
power off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn
on. If the error message remains please contact the Service Department for further assistance.
Distance:Spot (FOV)= 2.5:1
Emissivity = 0.1~1 Step.01
Wave Length = 8um-14um
Ref No.:032011
BATTERIES
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements
are possible
‘Battery Low’: battery needs to be
replaced, measurements are possible
‘Battery Exhausted’:
measurements are not possible
CHANGE BATTERIES
1. Æ Æ 2. Æ
3. Æ4. Æ
5. Æ
1. Please pick the rubber gasket on the battery cover by using small, pointed screwdriver with the “X” shaped, then
release the screw on the battery cover.
2. Open the battery cover.
3. Replace the new battery.
(Power Supply: AAA*2pcs, 1.5V)
4. First, close the bottom side and insert the battery cover, push downward and then press forward.
5. Use the same way as point 1 to close the battery cover and stuff the screw hole with the rubber gasket.
When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AAA*2
batteries. Please note: It is important to turn the instrument off before replacing the battery otherwise the
thermometer may malfunction. Dispose of used battery promptly and keep away from children.
SPECIFICATION
Infrared Scan function
(IRT Mode)
Thermocouple Probe (K type, Grounded)
(COT Mode)
Measurement Range -55~250°C (-67~482°F) -55~330°C (-67 to +626 oF)
Operating Range 0~50°C (32~122°F)
Accuracy
(Tobj=15-35°C, Tamb=25°C) +/-0.6°C (1.1 oF)
Accuracy
(Tamb=23+/-3°C)
-33~0:+/-(1°C+0.1/degree)
0~ 65: +/-1°C
65~250:+/-1.5% of reading
below -5 :+/-1°C
-5~ 65 : +/-0.5°C
above 65 :+/-1% of reading
Emissivity Range 0.95 default – adjustable 0.1 to 1
step .01
Resolution (-9.9~199.9°C) 0.2°C/0.5°F, otherwise 1°C/1°F
Distance:Spot 2.5:1
Dimension 22.18*38*160 mm(0.87*1.50*6.3inch)
Weight (with battery) 98.1g(3.5oz)
Battery Life 18 hours continuous use (auto power off after 15 seconds)
EMC/RFI
Readings may be affected if the unit is operated within a radio frequency electromagnetic field strength of
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
A new way to measure
temperature
Manufactured by Radiant Innovation Inc.
Add: 1F, No.3, Industrial East 9th Road, Science-Based Industrial Park,
HsinChu, Taiwan 300, Tel: +886 (3) 5644185, Fax: +886 (3) 5644170
E-mail: service@ZyTemp.com, Http://www.ZyTemp.com
Since the thermometer is
splash proof, please make
sure the battery cover is tight
for the thermometer and also
with the rubber gasket.

Other ZyTemp Thermometer manuals

ZyTemp TN905-05F User manual

ZyTemp

ZyTemp TN905-05F User manual

ZyTemp TN425LCE User manual

ZyTemp

ZyTemp TN425LCE User manual

ZyTemp TN01U User manual

ZyTemp

ZyTemp TN01U User manual

ZyTemp TN288LF User manual

ZyTemp

ZyTemp TN288LF User manual

ZyTemp TN49RXG User manual

ZyTemp

ZyTemp TN49RXG User manual

Popular Thermometer manuals by other brands

Unit UT325F user manual

Unit

Unit UT325F user manual

ACU-RITE 00305 instruction manual

ACU-RITE

ACU-RITE 00305 instruction manual

oneConcept Meatmaster manual

oneConcept

oneConcept Meatmaster manual

A/DA TEMPRO 550 operating instructions

A/DA

A/DA TEMPRO 550 operating instructions

ACU-RITE 00891W3 instruction manual

ACU-RITE

ACU-RITE 00891W3 instruction manual

Silvercrest KH 8105 Operation and safety notes

Silvercrest

Silvercrest KH 8105 Operation and safety notes

Master cool 52228 operating instructions

Master cool

Master cool 52228 operating instructions

Digi-Sense 20250-34 user manual

Digi-Sense

Digi-Sense 20250-34 user manual

SereneLife SLTM20 user manual

SereneLife

SereneLife SLTM20 user manual

Radiant TH879S user manual

Radiant

Radiant TH879S user manual

AccuMac AM1640 user guide

AccuMac

AccuMac AM1640 user guide

Ryobi RP4030 user manual

Ryobi

Ryobi RP4030 user manual

TESTO 110 instruction manual

TESTO

TESTO 110 instruction manual

Oakton Temp-16 instruction manual

Oakton

Oakton Temp-16 instruction manual

BORETTI BBA87 user manual

BORETTI

BORETTI BBA87 user manual

Dr.Frei T-30 instructions

Dr.Frei

Dr.Frei T-30 instructions

Topcom DIABLO 101 user guide

Topcom

Topcom DIABLO 101 user guide

Meec tools 010985 operating instructions

Meec tools

Meec tools 010985 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.