Specifications:
;Temperature measurement range: -55 to +220°C (-67~428°F)
;Operating temperature range: 0 to +50°C (32 to +122°F)
;Resolution: 0.2°C /0.5°F (for thermometer); 0.01sec (for Stop Watch)
;Accuracy (Tamb=23±3°C): -55~0°C: +/-(2+0.05/deg)°C; above 0°C: +/-2°C(4°F) or +/-2% of the reading,
whichever is greater
;Measurement Distance is18mm, Spot Size is 2.5 mm
;Emissivity Range: 0.95 default –adjustable 0.05 to 1
;Auto real time clock and Room temperature while power off
;°C / °F Switch, MIN/MAX/LOCK, Stop Watch function
;Battery Life: 15 hours continuous use (auto power off after 15seconds), The battery life of the shelf =8month.
;Power Supply:: AAA*2 batteries
Real time clock setting
1Power on: Press the “Meas. key”.
2Press the “Mode key” seven times and the “Set” icon starts
to flash, which indicates the setting screen.
3Press the “Meas. key” to make the “24” icon flashing, which
indicates the 12/24-hour setting screen.
Press the “Meas. key” again to set 12/24-hour Format from
24-hour to 12-hour.
4Press the “Mode key” to move the flashing in the sequence shown below to select other settings.
Hour ÆMinutes
5While the hour, minutes setting is flashing, use “Meas. key” to change it. Press “Mode key” when complete.
Use of the thermometer
1Always make sure the sensor lens is clean without any damage.
2Power on: Press the “Meas. key”.
3Temperature taking: Remove the head cover before taking
temperature. When you press the “Meas. key”, will get the
temperature immediately. If you hold down the “Meas. key”, the
reading of measurement will be continuous updated.
*Note: The measurement distance is18mm. Please make sure the
target is located at the focus point where two laser dots converged into one.
Note:Applications include the Water, Milk, Cloth, Skin, or visit Http://www.ZyTemp.com for further information.
Power off: Device will automatically power off if left idle for more than 15sec to extend battery life
**If you have set the“ clock” mode, after “power-off”, room temperature & clock will be showed on the
screen immediately.
CAUTION
1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE
MAY RESULT.
2. USE EXTREME CAUTION WHEN OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.
4. KEEP OUT OF REACH OF ALL CHILDREN.
Use of the Stop Watch
1Power on: Press the “Meas. key”.
2Press the “Mode key” four times and the “count”
icon starts to flash.
3For start or stop counting, press the “Meas. key”.
For reset counting, press the “Mode key”.
4Press “Mode key” to enter the thermometer
function
Other Functions
MIN / MAX