2easy DMR11-D8 User manual

- 1 -
DT 2-wire System
Quik Start Guide
ATTENTION:
This is an abbreviated Installation Manual, addressing
Wiring and Programming of the DT System only. For all
the detail information of DT 2-wire system, please refer
to the DT Technical Manual.
DT-ENG-QSG-V1 20091221

- 2 -
1.1. IN-OUT wiring without any distributor
Code=1, DIP-6=off
Code=31, DIP-6=off
Code=32, DIP-6=on
Code=2, DIP-6=off
ID=00
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
85~260AC
DPS PS5
1 2 3 4 5 6
ON
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
1
3
A
4
B
4
1 2 3 4 5 6
ON
CALL
UNLOCK
TALK/MON
IN-USE
4
5
2
1. System Wirings and Connections
Cable Usage A B
Twisted cable 2x0.75 mm260 60
Twisted cable 2x1 mm280 80
Cable Usage A B
Twisted cable 2x1 mm270 30
Twisted cable 2x1.5 mm270 50
When Monitor quantity < 20
When Monitor quantity > 20
[1]: Door Station, when there is only one Door Station,
the DIP bit-1 and bit-2 should be set to 00.
[2]: Power Supply(PS5), MUST be installed side by
side with the DPS unit.
[3]: Power Separator, MUST be installed side by side
with the PS5 unit.
[4]: Monitor, each one with a unique User Code
(Max.32 Monitors), the bit-6 of the DIP should be set
to 0 (off) if the Monitor is not at the end of the bus line.
[5]: Monitor, the bit-6 of the DIP should be set to 1 (on)
if the Monitor is connected at the and of the bus line.

- 3 -
1.2. IN-OUT wiring with DBC One-user distributor
ID=00
1 2 3 4 5 6
ON
85~260AC
DPS PS5
DBC
1 2 3 4 5 6
ON
Code=31, DIP-6=off
CALL
UNLOCK
TALK/MON
IN-USE
1 2 3 4 5 6
ON
Code=32, DIP-6=on
CALL
UNLOCK
TALK/MON
IN-USE
DBC
1 2 3 4 5 6
ON
Code=8, DIP-6=off
CALL
UNLOCK
TALK/MON
IN-USE
DBC
1 2 3 4 5 6
ON
Code=1, DIP-6=off
CALL
UNLOCK
TALK/MON
IN-USE
B
C
A
1
3
4
4
4
5
7
6
6
2
[1]: Door Station, when there is only one Door Station,
the DIP bit-1 and bit-2 should be set to 00.
[2]: Power Supply(PS5), MUST be installed side by side
with the DPS unit.
[3]: Power Separator, MUST be installed side by side
with the PS5 unit.
[4]: Monitor, each one with a unique User Code (Max.32
Monitors), the bit-6 of the DIP should be set to 0 (off) if
the Monitor is not at the end of the bus line.
[5]: Monitor, the bit-6 of the DIP should be set to 1 (on)
if the Monitor is connected at the end of the bus line.
[6]: DBC(DT Branch Controller) unit, each apartment
use one DBC unit to connect to the bus, except the last
apartmet at the end of the bus line.
[7]: DBC(DT Branch Controller) unit, at the end of
the bus line, can connect two apartments, the last
apartment and the 2nd last apartment.
Cable Usage A B C
Twisted cable 2x0.75 mm260 60 30
Twisted cable 2x1 mm280 80 40
Cable Usage A B C
Twisted cable 2x1 mm270 30 20
Twisted cable 2x1.5 mm270 50 30
When Monitor quantity < 20
When Monitor quantity > 20

- 4 -
1.3. Star wiring with 4 output distributor DBC-4
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
HI
HI
Code=32, DIP-6=on
Code=30, DIP-6=on
Code=31, DIP-6=on
Code=29, DIP-6=on
Code=4, DIP-6=on
Code=2, DIP-6=on
Code=3, DIP-6=on
Code=1, DIP-6=on
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
DBC-4
A B C D
IN
OUT
DBC-4
A B C D
IN
OUT
85~260AC
DPS PS5
ID=00
1 2 3 4 5 6
ON
A
C
B
1
3
2
4 4
4 4
4 4
6
5
4 4
[1]: Door Station, when there is only one Door Station, the DIP bit-1 and
bit-2 should be set to 00.
[2]: Power Supply(PS5), MUST be installed side by side with DPS unit.
[3]: Power Separator, MUST be installed side by side with the PS5 unit.
[4]: Monitor, each one with a unique User Code, note that all the bit-6 of
the DIP should be set to 1 (on) in this case.(Max.32 Monitors)
[5]: DBC-4(4 output Branch Controller) unit, the switch of the DBC-4
should be set to HI except the last one which is at the end of the bus
line.
[6]: DBC-4(4 output Branch Controller) unit, the switch of the DBC-4
should be set to 120 as it is at the end of the bus line.
Cable Usage A B C
Twisted cable 2x0.75 mm260 60 30
Twisted cable 2x1 mm280 80 40
Cable Usage A B C
Twisted cable 2x1 mm270 30 20
Twisted cable 2x1.5 mm270 50 30
When Monitor quantity < 20
When Monitor quantity > 20

- 5 -
1.4. Multi Door Station wiring
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
HI
ID=00
1 2 3 4 5 6
ON
ID=01
1 2 3 4 5 6
ON
ID=10
1 2 3 4 5 6
ON
ID=11
1 2 3 4 5 6
ON
DBC-4
A B C D
IN
OUT
85~260VAC
DPS PS5
Code=4, DIP-6=on
CALL
UNLOCK
TALK/MON
IN-USE
Code=3, DIP-6=on
Code=2, DIP-6=on Code=1, DIP-6=on
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
8
8
9
8
8
1
5
67
3
2 4
B
C
A
DPS-4
A B C D
BUS
[1]: The rst Door Station, the DIP bit-1 and bit-2 should be set to 00.
[2]: The 2nd Door Station, the DIP bit-1 and bit-2 should be set to 01.
[3]: The 3rd Door Station, the DIP bit-1 and bit-2 should be set to 10.
[4]: The 4th Door Station, the DIP bit-1 and bit-2 should be set to 11.
[5]: Power Supply(PS5), MUST be installed side by side with DPS unit.
[6]: Power Separator, MUST be installed side by side with the PS5 unit.
[7]: DPS-4(4 input Power Separator), can connect Max. 4 Door Stations.
[8]: Monitor, each one with a unique User Code, note that all the bit-6 of
the DIP should be set to 1 (on) in this case.(Max.32 Monitors)
[9]: DBC-4(4 output Branch Controller) unit, the switch of the DBC-4
should be set to HI except the last one which is at the end of the bus
line.
Cable Usage A B C
Twisted cable 2x0.75 mm260 60 30
Twisted cable 2x1 mm280 80 40
Cable Usage A B C
Twisted cable 2x1 mm270 30 20
Twisted cable 2x1.5 mm270 50 30
When Monitor quantity < 20
When Monitor quantity > 20

- 6 -
1.5. CCTV wiring with DCU
ID=00
1 2 3 4 5 6
ON
85~260VAC
DPS PS5
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
HI
DBC-4
A B C D
IN
OUT
Code=4, DIP-6=on
CALL
UNLOCK
TALK/MON
IN-USE
Code=3, DIP-6=on
Code=2, DIP-6=on Code=1, DIP-6=on
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
CALL
UNLOCK
TALK/MON
IN-USE
1 2 3 4 5 6
ON
DCU
AC
B
C
A
1
2
3
4
5
10 10
6
7
8 8
8 8
9
[1]: The rst Door Station, the DIP bit-1 and bit-2 should be set to 00.
[2]: Power Supply(PS5), MUST be installed side by side with DPS unit.
[3]: Power Separator, MUST be installed side by side with the PS5 unit.
[4]: DCU(CCTV Controller), can connect Max.2 CCTV cameras and
lamp/lock at the same time.
[5]: Light turn on button.
[6]: AC input for the lamp.
[7]: Lamp.
[8]: Monitor, each one with a unique User Code, note that all the bit-6 of
the DIP should be set to 1 (on) in this case.(Max.32 Monitors)
[9]: DBC-4(4 output Branch Controller) unit, the switch of the DBC-4
should be set to HI except the last one which is at the end of the bus
line.
[10]: CCTV camera.
Cable Usage A B C
Twisted cable 2x0.75 mm260 60 30
Twisted cable 2x1 mm280 80 40
Cable Usage A B C
Twisted cable 2x1 mm270 30 20
Twisted cable 2x1.5 mm270 50 30
When Monitor quantity < 20
When Monitor quantity > 20

- 7 -
2. Parts and Installations
2.1. PS5 - Power Supply
The PS5 power supply unit is designed for DT system to supply up to 32 Monitors and total 4 Door Stations at the same time.
• Universal AC input/full range.
• Multi protection: short sircuit, overload, over voltage
• Cooling by free air convection
• DIN rail mounting.
• Support up to 32 Monitors
• Support up to 4 Door Stations.
Dimension and Terminal
• L(AC): AC input.
• N(AC): AC input.
• : Earth Ground.
• V-: DC power output.(21.5~26.5 adjustable)
• V+: DC power output.(21.5~26.5 adjustable)
• VADJ: Output voltage adjustment.
• LED: Working state indicator.
Input Voltage: 85~260Vac, 120~370Vdc
Input Frequency: 47~63 Hz
Leakage Current: >2mA / 240Vac
AC current (TYP.) 1.5A /150Vac, 0.9A / 230Vac
Output VADJ range: 21.5~26.5 Vdc adjustable
Rated Voltage: 24Vdc
Rated Current: 3.2A
Rated Power: 76.8W
Electronic Specications
VADJ
LED
9
152.5
L (AC)
N (AC)
V-
V+
79
56
2-M3
1506.5
78
24
159
22 117
Unit: mm
9
81
83
DIN Installation
85~260AC
DPS
DIN nail
PS5

- 8 -
2.2. DPS - DT Power Separator
DPS: This unit is a power supply adaptor for the PS5 or PS4 power supply, it transfers the power from the power supply to the suitable
power for the non-polarity bus. Note that the DPS must work together with the PS5 or PS4 power supply.
2.3. DBC - DT Branch Controller
DBC: This unit is a single user distributor unit used to transfer all data between the Monitor and the Bus Line. Every Monitor(except the
last one at the end of the line) needs one DBC to connect to the Non-polarity Bus Line. No extra power supply needed, and one LED
indicator to show the working state.
Technical Specications(DPS)
Power input: 24Vdc (supplied by PS5)
Power output: 18Vdc
Power Consumption: 0.25W in standby, 0.5 W in actting
Working temperature: -5ºC +45ºC
Technical Specications(DBC)
Power Consumption: 0.25W standby, 0.5 W in working
Working temperature: -5ºC +45ºC
DPS
Connect to Door Station Connect to Monitor
Connect to
Power Supply(PS5)
Bus In/Out Bus Out(to Monitor)
DBC
Direct Wall Mounting DIN Rail Mounting
85mm
Use the screws to fasten the unit on the wall directly. Install on the DIN Rail.

- 9 -
2.4. DBC-4 - DT 4 output Branch Controller
DBC-4 (4 output Branch Controller)Distributor is a 4 output user distributor for DT system, to approach the star topology connection in
the apartment system. See Section 3 Cables and Connection for detail connection information.
2.5. DPS-4 - DT 4 input Power Separator
DPS-4 (4 input Power Separator)Unit is used to connect multi Door Stations, total 4 Door Stations can be connected to the DPS-4 unit.
In-use
Video Match
Power
ABCD
Trunk Bus
Bus Out Bus In
HI
120
set to 120 for the last DBC-4
on the building, the others
must be set to HI.
Connect to Monitors
DBC-4
ABCD
Trunk Bus
Connect to
Monitor/Distributor Connect to DPS
Connect to Door Stations
Direct Wall MountingDIN Rail Mounting

- 10 -
Jointer*2
Stopper
1 2 3 4 5 6
ON
L1
+12V T/R -
T/R+
LK - (GND)
CN-LK JP-LK
RS-485
SET
PA
PB
BUS
LK+(COM)
N.O.
EB+
EB -
L2
1
2
3
298.5 mm
114.5 mm
45 mm
Camera Angle adjustment
Open the mounting box of the panel, use a
cross screw to adjust the view angle of the
camera before installation.
Note
The double button line expansion panel can only
be connected to double button line Door Station;
the single button line expansion panel can only be
connected to single button line Door Station. For
example, the EP11/Dx can only be connected to
DMR11/Dx Door Station.
2.7. Door Station Mounting
Installation with expanding panel

- 11 -
2.8. Door Station DIP setting
Total 6 bits in the DIP switches can be congured. The switches can be modied either before or after installation.
ON(1)
=
OFF(0)
=
ON
ON
ON 123456
Bit denition Bit state Function Descriptions
Bit-1 and bit-2
Door Station ID
setting
1 2 3 4 5 6
ON
Default setting, ID = 0, set to the rst Door Station.
1 2 3 4 5 6
ON
ID = 1, set to the second Door Station.
1 2 3 4 5 6
ON
ID = 2, set to the third Door Station.
1 2 3 4 5 6
ON
ID = 3, set to the fourth Door Station.
Bit-3
User ID select
1 2 34 5 6
ON
Default setting for using a double line button Door Station.
1 2 34 5 6
ON
when using a single line button Door Station.
Bit-4
Button line select
12345 6
ON
Default setting for using the default codes of the button.
12345 6
ON
using the progremmed codes of the button.
Bit-5
Unlocking time quick
select
1 2 3 4 56
ON
Default setting, unlocking time = 1 second.
1 2 3 4 56
ON
Unlocking time = 5 seconds.(can be changed by software)
Bit-6
Function reserved
1 2 3 4 5 6
ON
Working state.
1 2 3 4 5 6
ON
Function reserved.
2.9. Standard Electronic Lock Connection
This example is a standard electronic lock wiring, by connecting the lock directly to the door station. note that the lock used here is
a 12Vdc 500mA power-to-unlock type. (other locks can be supported, please refer to DT technical manual for Lock connection detail
information-)
Exit Button
Electronic Lock
+
-+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
1 2 3 4 5 6
ON
SET
L1
T/R -
T/R+
RS-485
JP-LK
DMR11
Connection Board
PA
PB
BUS
L2
Connect to DPS or DPS-4
1
2
3

- 12 -
3.1. Monitor Mounting
1 2 3 4 5 6
ON
S1
L1 L2
SW+
SW-
EXT-RING
GND
VIDEO
POWER
INTERCOM
UNLOCK
TALK/
MONITOR
+
-
IN-USE
1 2 3 4 5 6
ON
DIPS
L1
BT1
BT2
EH
GND
VD
L2
CALL
UNLOCK
TALK/MON
IN-USE
1 2 3 4 5 6
ON
DIPS
L1
BT1
BT2
EH
GND
VD
L2
1 2 3 4 5 6
ON
S1
L1
L2
SW+
SW-
EXT-RING
GND
VIDEO
3. Monitor Mounting and User Code Setup
DMR11-D8
01 02 09 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
03 04
05 06
07 08
EP11-D24 EP11-S12 EP11-S12DMR11-S4
01 05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
02
03
04
3.2. What’s User Code
In 2-wire DT system, each Monitor installed in system must be programmed with a calling address or calling number, which is User
Code.
For Monitor, User Code is dened by 1~5 bits DIP switchers on the back of Monitor, according the User Code rules. For example, if you
want to program the Monitor’s User Code to be “03”, the Monitor’s 1~5 bit DIP switches should be set as: ON, ON, OFF, OFF, OFF.
For Door Station, each Call Button on panel is assigned to a specied User Code, and press this button will call related Monitor. For
example, press the call button pre-dened as “03”, system will launch a call to the Monitor which programmed with “03” User Code.
The User Code array on panels has been pre-dened as below, that’s the default mapping as follow:

- 13 -
3.3. Monitor User Code Setup
ON(1)
=
OFF(0)
=
ON
ON
ON 123456
Bit state User Code Bit state User Code Bit state User Code
1 2 3 4 5 6
ON
Code=1
1 2 3 4 5 6
ON
Code=12
1 2 3 4 5 6
ON
Code=23
1 2 3 4 5 6
ON
Code=2
1 2 3 4 5 6
ON
Code=13
1 2 3 4 5 6
ON
Code=24
1 2 3 4 5 6
ON
Code=3
1 2 3 4 5 6
ON
Code=14
1 2 3 4 5 6
ON
Code=25
1 2 3 4 5 6
ON
Code=4
1 2 3 4 5 6
ON
Code=15
1 2 3 4 5 6
ON
Code=26
1 2 3 4 5 6
ON
Code=5
1 2 3 4 5 6
ON
Code=16
1 2 3 4 5 6
ON
Code=27
1 2 3 4 5 6
ON
Code=6
1 2 3 4 5 6
ON
Code=17
1 2 3 4 5 6
ON
Code=28
1 2 3 4 5 6
ON
Code=7
1 2 3 4 5 6
ON
Code=18
1 2 3 4 5 6
ON
Code=29
1 2 3 4 5 6
ON
Code=8
1 2 3 4 5 6
ON
Code=19
1 2 3 4 5 6
ON
Code=30
1 2 3 4 5 6
ON
Code=9
1 2 3 4 5 6
ON
Code=20
1 2 3 4 5 6
ON
Code=31
1 2 3 4 5 6
ON
Code=10
1 2 3 4 5 6
ON
Code=21
1 2 3 4 5 6
ON
Code=32
1 2 3 4 5 6
ON
Code=11
1 2 3 4 5 6
ON
Code=22
Bit-6 line terminal setting:
Bit
state
Setting Bit
state
Setting
1 2 3 4 5 6
ON
Monitor not
at the end of
the line.
1 2 3 4 5 6
ON
Monitor at
the end of
the line.

- 14 -
4.5. Authorize master cards:
When Door Station is
in standby, press PA
button and hold for 3
seconds to get into the
master card manage
state
Show the card to be
autorized as MASTER
CARD ADD , you will
hear a long beep*1
show the card to be
authorized as MASTER
CARD DELETE , and then
the Reader willexit out
automatically.
4.1. Introduction
DMR11/ID/D8
4.2. How to add user cards:
4.3. How to delete user cards:
4.4. How to delete all user cards(formating):
Show the MASTER
CARD ADD card in
standby.
Note. sounded Di~,Di
Show the MASTER
CARD DELETE card in
standby.
Note. sounded Di~,Di
Show the MASTER
CARD DELETE card in
standby.
Note. sounded Di~,Di
Show the cards to be
added, one by one.
Note. Long beep if
add success, two long
beep if repeated.
Show the cards to be
deleted, one by one.
Note. Long beep if
deleted successfully
Show theMASTER
CARD ADD card to
run format operation.
Show the MASTER CARD
ADD card again to exit.
However, will exit if no card
was showed within 15s.
Show the MASTER CARD
DELETE card again to
exit.
However, will exit if no card
was showed within 15s.
Show the MASTER CARD
ADD card again within
3 seconds to conrm the
Format operation.
• Up to 1000 user cards can be registered by the Door Station.
• Easy management with LED state and Sound hint.
• There are two master cards, one MASTER CARD ADD card and one MASTER CARD DELETE
card, When adding a new master card, the old one will be replaced automatically.
• Card reading distance is from 3 to 5 cm.
The Master cards are necessary when you add or delete user cards, Please keep the Master cards
carefully. However, it is much easier to manage the ID cards using DT-CONFIG software.
4. Proximity ID Card Operation

- 15 -
Note 1: The MASTER CARD ADD card must be showed before the Reader can get
in to the Authorize DELETE-Card state, and make sure each operation have to take
place within 10 seconds, or the Door Station will return to normal state automatically.
State Operation Sound hint
standby state
show user card(registered) a long 'D~.' (door opens)
show user card(not-registered) 3 short 'Di' (Di, Di ,Di)
Card
management
state
Enter the card management state a long 'Di~' + a short 'Di' (Di~ Di)
Exit out the card management state 2 short 'Di' (Di ,Di)
Add card/Delete card/Format successful a long 'Di~' (Di~)
Add a already existed card 2 long 'Di~' (Di~, Di~)
Add card/Delete card/Format unsuccessful 3 short 'Di' (Di, Di, Di)
Add a debug card(16666666) 4 short 'Di' (Di, Di ,Di, Di)
Add card failure (1000 cards registered) 5 short 'Di' (Di, Di ,Di, Di, Di)
4.8. Card management shoud hints
DMR11/ID/D8
LED-A
LED-B
LED-C
LED-D
State LED-A LED-B LED-C LED-D
Standby ON ON ON ON
Authorize ADD-Card ON OFF OFF ON
Authorize DELETE-Card OFF ON OFF ON
Add user card ON OFF OFF OFF
Delete user card OFF ON OFF OFF
Format ON ON OFF OFF
4.9. Card management LED hints
4.6. Add user cards by Room:
4.7. Delete user cards by Room:
Show the MASTER
CARD ADD card in
standby
Show the MASTER
CARD DELETE card in
standby
Press a certain button on
the Door Station, then
show the cards which to
be assigned to this Room.
Then press an other button
and show the cards.....
Press the button(s)
that the cards belong
to on the Door Station.
(all cards belong to the
room will be deleted)
Show the MASTER
CARD ADD card
again to conrm and
exit.
Show the MASTER
CARD DELETE card
again to conrm and
exit.

- 16 -
5.1. Online search
Online search function is designed for the purpose of getting a quick view of the Monitors installing situations, or to check if each of
them works or not. It is very useful for installation maintain.
When the Online search is acting, the Door Station will search every Monitor with the User Code from 1 to 32. If the Monitor is one
line(work normally), the LED light of that button will light up, and one 'Di~' sound hit will be heared; if the Monitor is off line(disconnected
or malfunctioning), the LED light of that button will not light up, and a 'Di,Di,Di' sound hit will be heard. After 32 Monitors all be searched,
the Monitor will quit out automatically, or press PB button to abort the searching.
A. Manual search
To execute searching, just press PB button(or hold it for 3 seconds) on
Door Station Connection Board, the Door Station will start searching,
and the result is shown by lighting the related Name Label backlight
with sound tips. After 5 seconds, Door Station returns to normal.
• Press the PB button, will search the Monitors in the right Call
Buttons column.
• Press the PB button and hold for 3 seconds, will search the
Monitors in the left Call Buttons column.
PB button for 3 seconds
Online search range
01 02 09 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
03 04
05 06
07 08
PB button
Online search range
01 02 09 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
03 04
05 06
07 08
For Example, if 01, 03, 04, 11, 12, 13, 28 Monitors are installed and work correctly, the result will be:
press PB button and hold for 3 seconds
(or show the Online Search Card twice
with in 3 seconds)
01 02 09 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
03 04
05 06
07 08
(or show the Online Search Card once)
press PB button once
01 02 09 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
03 04
05 06
07 08
5.2. Auto-CallBack
The Auto-Callback function is designed for the purpose of testing the
Monitor's working state, which enable the installer to check a certain
Monitor working state by only one person.
Press and hole the Call Button for 2 seconds on any Monitor, the Door
Station will call the Monitor automatically, then the installer can answer
the call and check if system work properly(such as video, audio etc).
MENU
Calling...
CALL
UNLOCK
TALK/MON
IN-USE
1 2 3 4 5 6
ON
L1
+12V T/R -
T/R+
LK - (GND)
CN-LK JP-LK
RS-485
SET
PA
PB
BUS
LK+(COM)
N.O.
EB+
EB -
1
2
3
L2
1 2 3 4 5 6
ON
L1
+12V T/R -
T/R+
LK - (GND)
CN-LK
RS-485
SET
PA
PB
BUS
LK+(COM)
N.O.
EB+
EB -
1
2
3
L2
DMR11
Connection Board
5. Quik Debug
B. Use ID tag(Only for DMR11/ID series)
If the Door Station has ID card function(DMR11/ID series), it will be
equiped with a Online search Card with a card number of 16666666,
which is designed for the online search only.
• Show the Online search card on the card window one time within
3 seconds, the Door Station will start to search the Right column
Monitors.
• show the Online search card on the card window twice within
3 seconds, the Door Station will start to search the Left column
Monitors.
16666666
DMR11/ID/D8
This manual suits for next models
3
Table of contents
Other 2easy Intercom System manuals

2easy
2easy DMR12/S8 User manual

2easy
2easy IRIS/DT39 User manual

2easy
2easy 2-wire Series User manual

2easy
2easy DK1721 User manual

2easy
2easy DMR21 User manual

2easy
2easy DT43/D4 User manual

2easy
2easy DT-SCU User manual

2easy
2easy DT-597 User manual

2easy
2easy CDV17D User manual

2easy
2easy DMR21/D32/F1 User manual

2easy
2easy CDV4791 User manual

2easy
2easy DT692 User manual

2easy
2easy DT594 User manual

2easy
2easy DT24 User manual

2easy
2easy DT594 User manual

2easy
2easy DT 2-wire Quick start guide

2easy
2easy XT24 User manual

2easy
2easy DK4761 User manual

2easy
2easy DT 2-wire Quick start guide

2easy
2easy 2-wire Series User manual