2easy DT594 User manual

DT594 USER MANUAL(EN)
2-Wire Video Intercom System
Read this manual carefully before using the product, and keep it well for future use.

-2-
Introduction
The door station is designed with high resolution color CCD camera, it pro-
vides wide angle of 1050for DT 2-wire intercom system. The high white LED
for night view makes the door station working efciently at night.
The front panel is made of plexiglass or stainless steel with rainy cover for
better protection against water. One or two touch sensor call button can be se-
lected. The large name label with white backlight is covered by a fully secured
and ameproof glass plate.
Parts and Function
178
92
35.6
22
Camera Lens
Night View LED
Speaker
Nameplate
Call Button
Microphone
Rainy Cover
1 2
ON
Lock Control Jumper
Doorstation Code DIP
T/R+ T/R-
1 2 3
1 2
ON
BUS(Blue&Green)
S2+(Red)
PL(White)
S1+(Yellow)
S1-(Black)
Connection line
Terminal Description
Note:the door station support two call buttons to control two users.

-3-
Lock Control Jumper: To select the lock type.
Door Station Code DIP: Total 4 door stations can be supported.
T/R+,T/R-: USB-RS485 communication terminal.
Main Connect Port: To connect the bus line and the electronic locks.
BUS(Blue&Green): Connect to the bus line, non-polarity.
PL(White): External lock power input, connect to the power positive(power +).
S1+(Yellow): The rst lock power(+) output.
S2+(Red): The second lock power(+) output.
S-(Black): Lock power(-) output.
Door Station Mounting
1
Mounting with rainy cover
Mounting without rainy cover
2 3
1 2 3

-4-
System Wiring and Connections
Bus PL S1+ S2+ S-
-
+
monitor
AC~
PC6
Basic one-to-one Connection
Adjusting Camera Angle
1 2
ON
Use a screwdriver to loosen
the screw and then adjust the
angle of the camera ,then x
the screw.
The location of the unit should keep away from snow,rain,and intensity light.
Installation Steps:
Installation height for door station usually is 145~160cm.
1. Use screws to fix the back panel and rainy cover(if mounting with rainy
cover) to the wall after connect the cable correctly.
2. Attach the front panel to the back panel, then use the screw to x it.

-5-
Multi Door Stations Connection
85~260VAC
monitors
Bus PL S1+ S2+ S- Bus PL S1+ S2+ S- Bus PL S1+ S2+ S- Bus PL S1+ S2+ S-
1 2
ON
1 2
ON
1 2
ON
1 2
ON
1# Camera
DIP=on,off,off
ID=00
ID=10
ID=01ID=11
2# Camera3# Camera4# Camera
DBC-4S
A B C D
OFF
ON
Impedance
switch
AC~
PC6
Multi Monitors Connection
monitor monitor monitor monitor
Code=0, DIP-6=off
123 4 5 6
ON
Code=1, DIP-6=off
123 4 5 6
ON
AC~
PC6
Code=14, DIP-6=off
1 2 3 4 5 6
ON
Code=15, DIP-6=on
1 2 3 4 5 6
ON
1 2
ON
ID=00

-6-
With DBC-4S Wiring Mode
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=3, DIP-6=on
Code=1, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=2, DIP-6=on
Code=0, DIP-6=on
Code=15, DIP-6=on
Code=13, DIP-6=on
Code=14, DIP-6=on
Code=12, DIP-6=on
OFF ON
OFF ON
monitor
monitor
monitor
monitor
monitor
monitor
monitor
monitor
DBC-4S
A B C D
DBC-4S
A B C D
Impedance
switch
Impedance
switch
DIP=on,off,off
DIP=on,off,off
AC~
PC6
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2
ON
ID=00

-7-
Electric Lock Connection
Door Lock Controlled with Internal Power
connect one lock connect two locks
Note:
1. Electronic lock of Power-on-to-unlock type should be used.
2. The door lock is limited to 12V, and holding current must be less than
250mA.
3. The door lock control is not timed from Exit Button(EB).
4. The Unlock Mode Parameter of Monitor must be set to 0 (by default).
EB
*
LOCK
LOCK
2nd
1ST
2nd
EB
*
1ST
Jumper position in
Connect two locks
2-3
1 2 3
BUS PL S1+ S2+ S-
EB
*
LOCK
BUS PL S1+ S2+ S-
Jumper position in
Connect one lock
2-3
1 2 3
Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according to the lock.
2. Setup the Unlock Mode of Monitor for different lock types.
•Power-on-to-unlock type:Unlock Mode=0 (by default)
•Power-off-to-unlock type:Unlock Mode=1

-8-
LOCK
Take off the Jumper
POWER
SUPPLY
LOCK
Take off the Jumper
POWER
SUPPLY
LOCK
BUS PL S1+ S2+ S- BUS PL S1+ S2+ S-
connect one lock connect two locks
5.2.3 Unlock parameter setting(set on monitor)
1.Touch item on main
menu page.
2.Touch the screen anywhere and
hold for 2s.
3.Touch Installer setup item
4.A digital keypad and setting
instructions will be shown.
Manual
Monitor
Monitor
Memory
Playback
Album User Setup
09/30/2010 Thu.16:41
Close
Intercom Multimedia
H/W : --- a1.3
S/W: V17.11.418.00
Local addr: ---
Unlock timing: ---
Video standard: -
UI-CODE: ---
MCM-VER.: ---
Updated: ---
Home
Installer
setup
Caliber
TouchScreen
Code Number:[----]
[0010]#:Remove all remote control
[0011]#:Add remote control
[8000]#:Set as master unit 0
[8001]#:Set as slaver unit 1
[8002]#:Set as slaver unit 2
[8003]#:Set as slaver unit 3
[8004]#:Set as guard unit
[8005]#:Set as not guard unit
[8006]#:Panel on as slaver unit called
[8007]#:Panel off as slaver unit called
[8008]#:Date format:MM/DD/YYYY
[8009]#:Date format:DD/MM/YYYY
[8010]#:Set lock mode to 0
[8011]#:Set lock mode to 1
[8021]~[8029]
#Set the lock time of 1~9s
Multi language settings:
---
1
4
78
0
9
6
5
23
Cancel
Installation settings:
Note:
1.must connect correctly before setting.
2.the parameter will be saved in door station automatically,so you need only
set on one monitor.
3.the above diagram is t for icon menu series monitors only, to text menu se-
ries monitors,please refer to the corresponding user manual.

-9-
DIP Switches Setting
The DIP switch is designed to set the code
for door station and monitor, there are two
states for each DIP switch, please refer to
the sketch map.
ON(1)
=
OFF(0)
=
ON
ON
Total 2 bits can be congured, bit-1 and bit-2 are used to assign ID code for door sta-
tion.The switches can be modied either before or after installation.
There are 6 bits in total. The DIP switches are used to congure the user code
for Monitors.
Bit-6 is an video impedance match switch, which have to be set to ON if match
the impedance, otherwise set to OFF.
Bit-1~Bit-5 are used to set user code. If the door station with one call button,
the user code should be set to 0~15. If the door station with two call buttons,
the user code should be set to 0~31.
Please refer to the following settings:
Door station DIP setting
Indoor monitor DIP setting
Bit state Descriptions
Default setting, ID = 0(00), set to the rst Door Station.
ID = 1(10), set to the second Door Station.
ID = 2(01), set to the third Door Station.
ID = 3(11), set to the fourth Door Station.
12
ON
1 2
ON
1 2
ON
1 2
ON
Bit state Setting Bit state Setting
Not match Match the video impedance
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON

-10-
Bit state User code
code=0
code=1
code=2
code=3
code=4
code=6
code=7
code=8
code=9
code=10
code=5
Bit state User code Bit state User code
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
123 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
123 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
123 4 5 6
ON
1 2 3 4 5 6
ON
123 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
code=11
code=12
code=13
code=14
code=15
code=16
code=17
code=18
code=19
code=20
code=21
code=22
code=23
code=24
code=25
code=26
code=27
code=28
code=29
code=30
code=31
123 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Note:Monitors response button A must set the
user code from 0 to 15.and button B set the user
code from 16 to 31.
A A
B

-11-
Cables Requirements
The maximum distance of the wiring is limited in the DT system. Using dif-
ferent cables may also affect the maximum distance which the system can
reach.
The farest monitor
B
A
C
DBC-4S
monitor
monitor
monitor
with two or four monitors
AC~
PC6
When Monitor quantity < 20
Cable Usage A B C
Twisted cable 2x0.75 mm260 60 30
Twisted cable 2x1 mm280 80 40
When Monitor quantity > 20
Cable Usage A B C
Twisted cable 2x1 mm270 30 20
Twisted cable 2x1.5 mm270 50 30
Note:If the monitor has been specied
the distance,refer to the parameter.

The design and specications can be changed without notice to the user. Right to
interpret and copyright of this manual are preserved.
DT-ENG-594-V1 P130422
Specication
Power Supply : DC 24V (supplied by PC6);
Power Consumption: Standby 60mA; Working status 200mA;
Camera: 1/4 ACS 4T image sensor with DSP processor
Lock Power supply: 12Vdc, 300mA(Internal Power);
Working temperature: -10ºC ~ +45ºC
Dimension: 188(H)×110(W)×34(D)mm
Precautions
• Please clean the unit with soft cotton cloth, don't use the organic impregnant
or chemical clean agent. If necessary, please use a little pure water or dilute
soap water to clean the dust.
• The unit is weather resistant. However do not spray high pressure water on
access control keypad directly. Excessive moisture may cause problems with
the unit.
• You must use the right adaptor which is supplied by the manufacturer or ap-
proved by the manufacturer.
• Pay attention to the high voltage inside the products, please refer service
only to a trained and qualied professional.
Other manuals for DT594
1
Table of contents
Other 2easy Intercom System manuals

2easy
2easy DT24 User manual

2easy
2easy DT 2-wire Quick start guide

2easy
2easy DMR11-D8 User manual

2easy
2easy DT43/D4 User manual

2easy
2easy DMR21 User manual

2easy
2easy DT 2-wire Quick start guide

2easy
2easy 2-wire Series User manual

2easy
2easy IRIS/DT39 User manual

2easy
2easy 2-wire Series User manual

2easy
2easy 2-wire Series User manual