-8-
LOCK
Take off the Jumper
POWER
SUPPLY
LOCK
Take off the Jumper
POWER
SUPPLY
LOCK
BUS PL S1+ S2+ S- BUS PL S1+ S2+ S-
connect one lock connect two locks
5.2.3 Unlock parameter and Unlocking time programming (via Monitor)
1.Touch icon 2.Touch the screen and hold for 2s
3.Touch Installer setup icon
4.A digital keypad will opens
Manual
Monitor
Monitor
Memory
Playback
Album User Setup
09/30/2010 Thu.16:41
Close
Intercom Multimedia
H/W : --- a1.3
S/W: V17.11.418.00
Local addr: ---
Unlock timing: ---
Video standard: -
UI-CODE: ---
MCM-VER.: ---
Updated: ---
Home
Installer
setup
Caliber
TouchScreen
Code Number:[----]
[0010]#:Remove all remote control
[0011]#:Add remote control
[8000]#:Set as master unit 0
[8001]#:Set as slaver unit 1
[8002]#:Set as slaver unit 2
[8003]#:Set as slaver unit 3
[8004]#:Set as guard unit
[8005]#:Set as not guard unit
[8006]#:Panel on as slaver unit called
[8007]#:Panel off as slaver unit called
[8008]#:Date format:MM/DD/YYYY
[8009]#:Date format:DD/MM/YYYY
[8010]#:Set lock mode to 0
[8011]#:Set lock mode to 1
[8021]~[8029]
#Set the lock time of 1~9s
Multi language settings:
---
1
4
78
0
9
6
5
23
Cancel
Installation settings:
Using the keypad, type in following codes:
8010 # for Power-on-to-unlock mode
8011 # for Power-off-to-unlock mode
Next step is to set unlocking time. Refer to the Installer Setup info or to the
monitor manual because codes are different for different models.
NOTE: Locks must be connected before programming. Programming should
be done on one monitor only. Settings will be synced with door station