2easy DT 2-wire Quick start guide

DT 2-wire
Video Intercom System
Technical Guide

CONTENT
Section1 - Introduction 1
System Features-- - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1
System Capacity- - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1
System Extension- - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - 1
System Function- - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1
Section2 - Units and Installations 4
DoorStation-- - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - 4
Features- - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
Parts and functions - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5
Place Name Plate- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - 5
Electronic Specifications- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5
StandardInstallation - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
Installation with expanding panel-- - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - 6
Terminal Descriptions-- - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7
Door Station wiring - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7
DIP Switches settings - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - 8
Door Station Lock Connections-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - 9
Proximity ID Card Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - 11
Monitor-- - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - 13
Features- - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -13
Electronic Specifications- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13
Terminal Descriptions-- - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -14
Intercom function-- - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -14
Camera Auto Switching - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - -16
Color Picture Memory - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - -16
SD Card- - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -16
User Code Setup-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - -17
Monitor Extending Connection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - -18
Accessories-- - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - 19
PS5 - Power Supply-- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - -19
DPS- - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -21
DBC- - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -21
DBC-4 Unit- - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -23
DPS-4 Unit- - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -23
DCU Unit- - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -25

Section3 - Cables and Connections 28
GeneralRulesforInstallation-- - - - - - - - - - - - - - - - - - - - -
28
Connectingthe Connectors - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - -28
Installation Height - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -28
Door Station Install Condition- - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - -28
Table of Cables and Distance- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - -29
SystemWiringsandConnections-- - - - - - - - - - - - - - - - - -
30
1. Basic IN-OUT wiring mode- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - -30
2. Basic IN-OUT wiring mode (1~n risers) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 31
3. IN-OUT wiring with One-user distributor- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 32
4. Basic Star wiring mode-- - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - -33
5. 4 Door Stations andstar wiring mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 34
6. 1 Door Station and 2 CCTVcameras- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 35
7. Mixed 1/4 user distributors wiring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - -36
Section4 - Setup and Debug 37
SystemOperations-- - - - - - - - - - - - - - - - - - - - - - - - - - - -
37
Busy State Management - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-37
Door Station Function - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - -38
SystemSetup-- - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - 39
What’s User Code- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - -39
What's Slave Address - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - -40
Online search- - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -41
Simulating Call - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -42
Section5 - DT CONFIG Software 43
Introduction-- - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -43
Hardware connection- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - -43
Interface Preview-- - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -44
This technical document is published for information purposes by Guangzhou Video-Tech Electronics.
In a policy of ongoing improvement, Guangzhou Video-Tech Electronics reserves the right to modify
the contents of this document and the features of the products referred to herein at any time and
without prior notice. Anysuch modifications shall be reflected in subsequent editions of this document.

Section1 - Introduction
System Features
• With only 2 wires (no polarity) throughout the whole installation, the 2-wire DT system is a simplified installation
system with minimum wiring and powerful features. The minimum wiring drastically reduces installation times and
errors. By means of FM video modulation and ASK data transmission technology, system provides better
protection against interference, which guarantees best color quality at all points of the installation.
• Centralized power supply for the entire system. With advanced power management, the whole system use only
one power supply, so there is no power supply needed for any Monitor or other system parts.
• Use Plug-in connectors and DIP switchers for more rapid installation.
• Flexible cable connection to wire, support in-out, branching and mixed mode.
• Multi Monitors for one apartment/house in same User Code, and automatically switching the video.
• Online searching and diagnose function for installer.
• Using PC to program and diagnose the system.
System Capacity
• Max. 4 Door Stations, or 3 Door Station plus 2 CCTV cameras, or 1 Door Station plus 6 CCTV cameras.
• Max. 32 Monitors in a system, max.4 Monitors in same User Code.
• Proximity access control function, max. 1000 user ID cards.
• Maximum 150 meters distance from Door Station to the farthest Monitor.
System Extension
• Connect Door Strike and Exit Button to Door Station directly.
• Connect door bell and extra ringer to Monitor directly.
• Control staircase light or relay executors for second electronic lock.
• Connect up to 6 CCTV cameras by DCU unit.
System Function
• Name list intercom
• Inner call intercom among Monitors in same Room Code
• One Monitor can be programmed as Guard unit
• Color Memo or SD card DVR function
1

Villa Application
Although the DT system is mainly designed
for the small apartment system usage, it can
be used in villa or villa group applications.
Multi Monitors can be installed in a family with
the same User Code, or many houses can
be connected as one system, and all of these
Monitors can have calling conversation each
other.
2
2
2
2
DPS
PS5 AC
2
2
Apartment Applications
This is the most common way that the system
is used. One building or multi buildings can be
connected as one system. Every apartment
can open the door, and the users in the
system can have intercom talk each other.
DT - System - Technical Guide 2

3

Section2 - Units and Installations
Door Station
Bit-4=off
ON
1 2 3 45 6
DMR11/ID/D8 DMR11/D8 EP11/D24
Bit-4=on
ON
1 2 3 45 6
DMR11/ID/S4 DMR11/S4 EP11/S12
Features
• Full anodize aluminum panel.
• SONY color CCD camera.
• camera angle adjustable.
• ID card access control
• Night-view LED with CDS light sensor.
• Backlit name plate for each button.
• Use DIP switches for multi Door Station configuration.
• Direct connect to electronic lock of 12Vdc.
• Exit button.
• USB-RS485 interface to connect to computer.
• Plug-in connector to connect bus line.
• On line Monitor search.
DT - System - Technical Guide 4

308 mm
298.5 mm
Parts and functions
Camera Lens
CDS Sensor
Infrared LED Camera Angle
adjustment
Speaker
Microphone
Name plate
Call button
123 mm
Place Name Plate
Speaker Vol
adjustment
Connection
Board
18 mm 45 mm 114.5 mm
Press down and shift right/left to open the transparent name plate cover, then insert the name paper, then put the
plate cover back to the panel. Note that double button line panel can be opened both direction, single button line Can only
be opened at right side.
Electronic Specifications
Power supply: 24Vdc(supplied by PS5)
Power Consumption: 1W in standby, 15 W in working
Unlock Power output: 12Vdc 300mA
NO, COM exchange contact: Max. 48V dc 1.5A
Monostable relay activation time: 1 second to 10 minutes ±5%
Working temperature: -5ºC +45ºC
5

1 2 3 4 5 6
ON
RS
-485
SET
298.5 mm
Standard Installation
Camera Angle adjustment
Open the mounting box of the panel, use a
cross screw to adjust the view angle of the
camera before installation.
Installation with expanding panel
Jointer*2
Stopper
Note
The double button line expansion panel can
only be connected to double button line Door
Station; the single button line expansion panel
can only be connected to single button line
Door Station. For example, the EP11/Dx can
only be connected to DMR11/Dx Door Station.
+12V T/R -
LK - ( G ND)L K+( C OM)
T/R+
N.O.EB+EB -
L1 L2
PA
12
PB
3 BUS
DT - System - Technical Guide 6

SET
RS
-
485
RS
-485
SET
Terminal Descriptions
+12V T/R -T/R+
LK - (GND)LK+(COM)
N.O.
EB+
EB -
DMR11
Connection Board
1
2
3
L1 L2
•
+12V:
12VDC power output.
•
LK-(GND):
power ground.
•
LK+(COM):
electronically load activation relay contact common.
L1 L2
PA
PB
BUS
•
NO.:
electronic load activation relay normally open contact (the default setting for this terminal is NO, this
terminal can be configured to NC, normally-closed contact by the DT CONFIG software). That means, by
default, only the power-to-unlock type of electronic lock can be connected to the COM and NO terminal, if using
the power-off-to-unlock type locks, the NO terminal must be set to NC contact by the DT CONFIG software.
•
EB+:
Exit button.
•
EB-:
Exit button.
•
JP-LK:
For electronic lock safety type setting(refer to Door Station Lock Connections).
•
T/R-:
USB-RS485 communication terminal negative.
•
T/R+:
USB-RS485 communication terminal positive.
•
SET:
DIP switches for system configurations.
•
PA:
Press once to send the name list to Monitor; press and hold for 3 seconds to add Master card.
•
PB:
Press once to search the Right line Monitor; press and hold for 3 seconds to search left line Monitor.
•
Bus(
L1,L2
):
non-polarity bus line.
Door Station wiring
This example is one Door Station wiring, note that the lock used here is a 12Vdc 300mA power-to-unlock type.
-
+12V
T/R -
LK - (GND)LK+(COM)
T/R+
+
N.O.
Connect PC
EB+EB -
Outlet Button
1
L1 L2
PA
23
PB
Connect to DPS or DPS-4
7

DIP Switches settings
Total 6 bits in the DIP switches can be configured. The switches can be modified either before or after installation.
• Bit-1 and Bit 2 is for Door Station ID settings, when muti Door Stations are installed in the system, these two bit
ON(1) OFF(0)
= =
ON
1
2 3 4 5 6
must be set correctly, the first Door Station set to 00, the second one set to 01, the third one set to 10, the fourth one
set to 11. If only one Door Station is installed, set to 00.
•
•
•
•
Bit-3: Single line button Door Station or double line button Door Station selection. If the Door Station is a double
line button, for example, the DMR11-D8, set this bit to 0, set to 1 for single line button Door Stations.
Bit-4: Button code selection; if use the default codes for each button of the Door Station, set to 0, if use the
programmed codes, set to 1.(the code for each button can be programmed by the DT CONFIG software, see the
program section in this manual)
Bit-5: Unlocking time quick selection, by default it is set to 0, for 1 second unlocking time; set to 1 for 5 seconds.
(this 5 second unlocking time can be changed by DT-CONFIG software)
Bit-6: MUST be set to off.
Bit definition Bit state Function Descriptions
Default setting, ID = 0, set to the first Door Station.
ON
1 2 3 4 5 6
ID = 1, set to the second Door Station.
ON
1 2 3 4 5 6
Bit-1 and bit-2
Door Station ID setting ID = 2, set to the third Door Station.
ON
1 2 3 4 5 6
ID = 3, set to the fourth Door Station.
ON
1 2 3 4 5 6
Default setting for using a double line button Door Station.
Bit-3
User ID select
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
when using a single line button Door Station.
Default setting for using the default codes of the button.
Bit-4
Button line select
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
using the programmed codes of the button.
Default setting, unlocking time = 1 second.
Bit-5
Unlocking time quick select
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Unlocking time = 5 seconds.(can be changed by software)
Working state.
Bit-6
Function reserved
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Function reserved.
DT - System - Technical Guide 8

RS
-485
SET
RS
-
485
SET
Door Station Lock Connections
+12V T/R -
LK - (GND) T/R+
LK+(COM)
N.O.
EB+
EB -
DMR11
Connection Board
+12 VLK - (G ND)
T/ R - T/ R +
LK +( CO M)N . O. E B +E B -
1
L1 L2
PA
2 3
PB
BUS
1. Direct lock connection
L1 L2
PA
1
2
3 PB
BUS
Use the power of the system to supply for the electronic lock, so that the lock can connect to the Door Station directly,
without an additional power supply for the electronic lock. Note that the Door Station can only output a 12Vdc power;
therefore the kind of lock used is limited.
•
•
•
•
•
The rated power of the lock must be less than 12Vdc 300mA when using direct lock connection method.
The GND must connect to the negative of the lock, and the COM connects to the positive.
Jumper set to 1-2 position for Power-to-Unlock safety type; set to 2-3 position for Power-off-to -Unlock type(in
this case the Unlock Relay mode should be set to Normally Closed on DT CONFIG software)
The 5th bit of the DIP switches is for the unlocking time setting, its set to off by default, for 1 second unlocking
time. If set this bit to on, the unlocking time is 5 seconds.
If different unlocking time is needed to be configured, the DT CONFIG software can be used to change the
Unlock Timingon the Parametertab(see the program section).
A. Connection for Power-to-Unlock type:
+12V
DIPS
-
LK - (GND)
+
LK+(COM)
N.O.
ON
1 2 3 4 5 6
EB+
12V 300mA
EB -
1
Jumper set to 1-2 position
2
3
DIPS-5: default set to off,
unlocking time is 1 second.
(In most cases, 1 second is
work for Power-to-Unlock type)
9

B. Connection for Power-- off-to-Unlock type:
-
+12V
LK - (GND)
LK+(COM)
+
N.O.
12V 300mA
EB+
EB -
Jumper set to2-3position
12
settoNormallyClosedonthe
3
UnlockRelay mode onDTsoftware.
2. Additional power supply
DIPS
ON
1 2 3 4 5 6
DIPS-5: set to on,
unlocking time is 5 seconds.
When the electronic lock is over 12 Vdc, additional power supply for the lock is needed.
• The power supply for the lock must be less than 48Vdc 1.5A.
•
The Jumper must be removed when using additional power supply. The default is set for Power-to-Unlock
type(Normally open), if use Power-off-to-Unlock type, change the Unlock Relay mode to Normally closed on
the Parameter tab of DT CONFIG software.
• If different unlocking time is needed to be configured, please use the DT CONFIG software to change the setting
on the Parametertab(see the program section).
C. Connection for Power-to-Unlock type:
Note:
Cut off this line when using
additional power supply
+ -
+12V
DIPS
+
LK - (GND)
LK+(COM)
N.O.
1 2 3 4 5 6
-
EB+
EB -
Removethe Jumper
1
set toNormally Open onthe
2
3
UnlockRelaymode.(default)
ON
DIPS-5: default set to off,
unlocking time is 1 second.
(Inmost cases, 1 second is
work for Power-to-Unlock type)
D. Connection for Power-- off-to-Unlock type:
Note:
Cut off this line when using
additional power supply
+ -
+
-
Remove the Jumper
settoNormallyClosedonthe
+12V
DIPS
LK - (GND)
LK+(COM)
N.O.EB+
ON
1 2 3 4 5 6
EB -
DIPS-5: set to on,
1
unlocking time is 5 seconds.
2
3
UnlockRelay mode onDTsoftware.
DT - System - Technical Guide 10

Proximity ID Card Operation
• Up to 1000 user cards can be registered by the Door Station.
• Easy management with LED state and Sound hint.
• There are two master cards, one MASTER CARD ADDcard and
one MASTER CARD DELETE card, When adding a new master
card, the old one will be replaced automatically.
• Card reading distance is from 3 to 5 cm.
The Master cards are necessary when you add or delete user cards,
Please keep the Master cards carefully. However, it is much easier to
manage the ID cards using DT-CONFIG software.
DMR11/ID/D8
How to add user cards:
Show the cards to be added, Show the MASTER
Show the MASTER CARD one by one. CARD ADD card again to
ADDcard in standby. Note. Long beep if add exit.
Note. sounded Di~,Di success, two long beep if However, will exit if no card
repeated. was showed within 15s.
How to delete user cards:
Show the cards to be deleted, Show the MASTER
Show the MASTER CARD one by one. CARD DELETE card
DELETEcard in standby. Note. Long beep if deleted again to exit.
Note. sounded Di~,Di successfully However, will exit if no card
was showed within 15s.
How to delete all user cards(formatting):
Show theMASTER CARD Show the MASTER CARD
Show the MASTER CARD
DELETE card in standby.
Note. sounded Di~,Di
Authorize master cards:
When Door Station is in
standby, press PAbutton and
hold for 3 seconds to get into
the master card manage state
ADD card to run format
operation.
Show the card to be authorized
as MASTER CARD ADD ,
you will hear a long beep*
1
ADD card again within
3 seconds to confirm the
Format operation.
show the card to be
authorized as MASTER
CARD DELETE, and
then the Reader willexit out
automatically.
11

Add user cards by Room:
Press a certain button on the
Show the MASTER CARD Door Station, then show the Show the MASTER
ADDcard in standby cards which to be assigned to CARD ADD card again to
this Room. Then press another confirm and exit.
button and show the cards......
Delete user cards by Room:
Press the button(s) that the Show the MASTER
Show the MASTER CARD
DELETEcard in standby cards belong to on the Door CARD DELETE card
Station.(all cards belong to the again to confirm and exit.
room will be deleted)
Note 1: The MASTER CARD ADD card must be showed before the Reader can get in to the Authorize DELETE
Card state, and make sure each operation have to take place within 10 seconds, or the Door Station will return to
normal state automatically.
Card management should hints
State Operation Sound hint
standby state show user card(registered) a long 'D~.' (door opens)
show user card(not-registered) 3 short 'Di' (Di, Di ,Di)
Enter the card management state a long 'Di~' + a short 'Di' (Di~ Di)
Exit out the card management state 2 short 'Di' (Di ,Di)
Card Add card/Delete card/Format successful a long 'Di~' (Di~)
management
state
Add a already existed card 2 long 'Di~' (Di~, Di~)
Add card/Delete card/Format unsuccessful 3 short 'Di' (Di, Di, Di)
Add a debug card(16666666) 4 short 'Di' (Di, Di ,Di, Di)
Add card failure (1000 cards registered) 5 short 'Di' (Di, Di ,Di, Di, Di)
Card management LED hints
State LED-A LED-B LED-C LED-D
Standby ON ON ON ON
Authorize ADD-Card ON OFF OFF ON
Authorize DELETE-Card OFF ON OFF ON
LED-D
Add user card ON OFF OFF OFF
LED-C
Delete user card OFF ON
LED-B
OFF OFF
LED-A
Format ON ON OFF OFF
DMR11/ID/D8
DT - System - Technical Guide 12

Monitor
Features
POWER
+
IN-USE
-
LCD screen
LED Indicator
Speaker
+ Button
- Button
CALL
UNLOCK
TALK/MON
LCD Touch Screen
Microphone
CALL button
UNLOCK button
INTERCOM
MENU Button
UNLOCK
INTERCOM Button
T A LK / M O N I T O R
UNLOCK Button
TALK/MON Button
Microphone
Mounting Hook
Connection Port
Mounting Hook
• Touch screen optional.
• 128 pieces color picture memory optional.
• Using DIP for Monitor ID setting.
• Using plug-in connector.
• On screen namelist for intercom.
• No additional power supply needed(supplied by system).
• TV-OUT function for connecting the TV.
• Additional door bell call button
• External ringer connection
Electronic Specifications
IN-USE
1 2 3 4 5 6
TALK/MON button
LED indicator
Speaker
Ventilation Vent
Mounting Hook
Connection Port
Mounting Hook
Power supply: 24Vdc(supplied by DPS)
Power Consumption: 1W in standby, 10 W in working
Working Currency: Max.30mA in standby, 500mA in working
TV output signal: 1V
p-p
CVBS
External Ringer: 12Vdc 100mA
13

Terminal Descriptions
Monitor S1
Connection Board
ON
SW+
SW-
1 2 3 4 5 6
EXT-RING
GND
VIDEO
BUS
Intercom function
•
SW+:
Door bell call button.
•
SW-:
Door bell call button.
•
EXT-RING:
External ringer output(12Vdc 100mA)
•
GND:
Ground.
•
VIDEO:
Video signal output.
•
S1:
DIP switches for system configurations.
•
BUS:
non-polarity bus line.
There are three kinds of intercom function available in the DT system.
1. Guard Unit Call
A Monitor can be assigned to be the guard unit Monitor, by setting on the OSD screen of the
Monitor. When the user's Monitor is in standby, press call button or intercom button, the intercom
page will show up on the screen, than select and confirm 'Call Guard Unit' item, and the Monitor
will call the guard unit Monitor, when the guard unit Monitor answers the call, conversation with
the guard person is started.
2. Inner Call
When multi Monitors are installed in one apartment, inner call is available. Note that all Monitors should have the
same User Code, and the Master and Slave address should be set on the Monitor(see page 40 for detail
information).
When the Monitor is in standby, press call button or intercom button, the intercom page will show up on the screen,
than select and confirm 'Inner Call' item, and other Monitors will ring at the same time. When any Monitor answers the
call, other Monitors will stop ringing and go back to standby state.
3. Intercom Call (Namelist)
The namelist intercom is for apartment to apartment calling. The user in one apartment can call other apartments by
selecting the name on the screen. In this way, it's no need to remember the ID(User Code or room address) of the
other users. A complete name list of all the users in the system can be upload to the Door Station by the DT CONFIG
software, and then the Door Station will send the name list to all Monitors.
DT - System - Technical Guide 14

Step 1: Run the DT CONFIG software. Connect the USB-485 Convertor to the DMR11 Door Station and the PC,
double click the software to make it running on the PC, then click the Namelist tap, the screen will be showed:
Step 2: Edit the namelist. In the name input field, there is a Room No. column and a Name Label column, each User
Code has a corresponding Room No. and a Name Label. Input all the names in the Name label field for each User
Code, and then click Download Namelist Button to download the namelist to the Door Station, and the Door Station will
sent the data to all the Monitors in the system.
Step 3: Calling people using the namelist. After downloaded from the PC, every Monitor will have a built-in namelist. To
access the namelist, go to the Main menu, select Intercom -- > Intercom Call to enter the intercom namelist
screen(see the picture bellow), and then just select the user name to call the other apartment.
play
monitor
intercom
setup
exit
Intelligent HomeS y s t em
Intercom Function
Intercom Call
Inner Call
Direct Call Guard Unit
Exit
Intelligent HomeS y s t em
[0101] Jim Zhang
[0102] Cherry Shi
[0201] David Le
[0202] Calo Lou
[0301] Samuel G
Intelligent HomeS y s t em
15

Camera Auto Switching
When multi Door Stations or CCTV cameras are installed in the system, Monitor can display the video one after
another. The Monitoring time for each Station or Camera must be set by the DT-CONFIG software manually to enable the
Auto Switching function(DT-CONFIG-- >Parameter-- >Camera Switching Time). Also, you can touch the icon on the
screen to monitor a specific camera only.
Color Picture Memory
Total 128 pcs picture can be stored in the Monitor. User can both record the picture manually and set the Monitor to
automatically record pictures.
•
Manually record: when the Monitor is in monitoring or talking state(the screen is turned on), press the record
icon on the touch screen or press a record button, the current picture which show on the screen will be saved into
the built-in flash memory of the Monitor.
• Automatically record: A picture will be saved after 2 seconds the visitor pressed the call button on the Door
Station. To enable the auto record function, go to the Main-- >Setup menu, and turn on the 'Auto Record' item.
• Pictures can be deleted manually using the touch screen.
• When the memory is full(about 128 pcs), the oldest picture will be replaced by the latest saved picture.
SD Card
Built-in SD card reader, maximum 2 GB supported.
•
Video and audio(DVR) record: Automatically or manually record can be set in need, total 4.5 hours recording
time; play back on the Monitor or on the PC.
• Digital Photo frame: play back the pictures (JPEG format only) on the SD card using a slide show as photo frame.
• MP3 background music: The MP3 files on the SD card can be played as a background music.
DT - System - Technical Guide 16

User Code Setup
In the DT system, every apartment must have a unique identification called User Code. The DIP switches are used to
configure the User Code for each Monitor.
• Bit-1 to Bit-5 are used to User Code setting. The value is from 1 to 32, which have 32 different codes for 32
apartments.
• When multi Monitors are installed in one apartment, these Monitors have to use the same User Code setting,
and the Master/Slave mode should be set on the Monitor.
• Bit-6 is line terminal switch, which have to be set to ON if the Monitor is in the end of the line(bus), otherwise set
to OFF. The end of the line is terminal that no other section will start from it.
Bit-6 line terminal setting:
ON(1) OFF(0)
Bit state Setting Bit state Setting
ON
1
2 3 4 5 6
= =
ON
1 2 3 4 5 6
Monitor not at
the end of the
line.
ON
1 2 3 4 5 6
Monitor at
the end of
the line.
Bit state User Code Bit state User Code Bit state User Code
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Code=1
Code=2
Code=3
Code=4
Code=5
Code=6
Code=7
Code=8
Code=9
Code=10
ON ON
Code=12
1 2 3 4 5 6
1 2 3 4 5 6
ON ON
Code=13
1 2 3 4 5 6
1 2 3 4 5 6
ON ON
Code=14
1 2 3 4 5 6
1 2 3 4 5 6
ON ON
Code=15
1 2 3 4 5 6
1 2 3 4 5 6
ON ON
Code=16
1 2 3 4 5 6
1 2 3 4 5 6
ON ON
Code=17
1 2 3 4 5 6
1 2 3 4 5 6
ON ON
Code=18
1 2 3 4 5 6
1 2 3 4 5 6
ON ON
Code=19
1 2 3 4 5 6
1 2 3 4 5 6
ON ON
Code=20
1 2 3 4 5 6
1 2 3 4 5 6
ON ON
Code=21
1 2 3 4 5 6
1 2 3 4 5 6
Code=23
Code=24
Code=25
Code=26
Code=27
Code=28
Code=29
Code=30
Code=31
Code=32
ON
1 2 3 4 5 6
Code=11
ON
Code=22
1 2 3 4 5 6
17
Other manuals for DT 2-wire
1
Table of contents
Other 2easy Intercom System manuals

2easy
2easy DT594 User manual

2easy
2easy 2-wire Series User manual

2easy
2easy XT24 User manual

2easy
2easy DMR11-D8 User manual

2easy
2easy DT594 User manual

2easy
2easy DT-SCU User manual

2easy
2easy CDV4791 User manual

2easy
2easy 2-wire Series User manual

2easy
2easy 2-wire Series User manual

2easy
2easy DMR21 User manual

2easy
2easy DT24 User manual

2easy
2easy DT-597 User manual

2easy
2easy DK4761 User manual

2easy
2easy IRIS/DT39 User manual

2easy
2easy DT43/D4 User manual

2easy
2easy DT 2-wire Quick start guide

2easy
2easy DMR21/D32/F1 User manual

2easy
2easy DK1721 User manual

2easy
2easy DMR12/S8 User manual

2easy
2easy DT692 User manual