6Mounting/installation
Pos:21 /B us ch-Jaeg er (Neus truktur )/M odul-S truktur/O nline-Dok u mentatio n/Siche rheit (- -> Fü ralle D okument e <--) /War nhinweis e/Siche rheit - N ie derspan nungs- und 230V -Leitung en @ 18\ mod_13 026 178214 91_15.d ocx@ 103 465 @ @ 1
Warning
Electric voltage!
Dangerous currents flow through the body when coming into direct or indirect contact with live
components.
This can result in electric shock, burns or even death.
■Disconnect the mains power supply prior to installation and/or disassembly!
■Permit work on the 110-240 V supply system to be performed only by specialist staff!
Pos:22 /B usch-J aeg er (Neus truktur )/M odul-S truktur/O nline-Dok u mentatio n/Siche rheit (- -> Fü ralle D okument e <--) /War nhinweis e/Siche rheit - Fachkenn tnisse @ 18 \mod_1 302 774384 017_15. docx@ 10 3564 @ 2 @ 1
6.1 Requirements for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering knowledge and experience.
• Incorrect installation endangers your life and that of the user of the electrical system.
• Incorrect installation can cause serious damage to property, such as a fire.
The minimum necessary expert knowledge and requirements for the installation are as follows:
• Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power.
2. Secure against being re-connected.
3. Ensure there is no voltage.
4. Connect to earth.
5. Cover or barricade adjacent live parts.
• Use suitable personal protective clothing.
• Use only suitable tools and measuring devices.
• Check the type supply network (TN system, IT system, TT system) to secure the following
power supply conditions (classic connection to ground, protective earthing, necessary
additional measures, etc.).
Pos:23 /D i nA4 -A nl eitungen Onlin e/In halt/KNX /DoorE nt ry/Monta ge/Mont agehinw eis e- A llg emein @ 1 9\mod_ 131056 367047 8_15.docx @ 1077 43 @ 2 @ 1
6.2 General installation instructions
• Terminate all branches of the wiring system via a connected bus device (e.g., indoor station, outdoor station,
system device).
• Do not install the system controller directly next to the bell transformer and other power supplies (to avoid
interference).
• Do not install the wires of the system bus together with 230 V wires.
• Do not use common cables for the connecting wires of the door openers and wires of the system bus.
• Avoid bridges between different cable types.
• Use only two wires for the system bus in a four-core or multi-core cable.
• When looping, never install the incoming and outgoing bus inside the same cable.
• Never install the internal and external bus inside the same cable.
Pos:24 /B usch-J aeg er (Neus truktur )/M odul-S truktur/O nline-D oku mentatio n/Steuer modul e - Onlin e-Dokume ntati on( -- > F ür alle D okume nte <- -)/ +++ +++++++ ++S ei tenumb ruch + +++ ++ ++++++ @ 9\m od_126 8898668 093 _0.doc x @ 521 49 @ @ 1