Absen JP Series User manual

JP Series User Manual
STEP
Simple Operation
Panel Weight Cooling System Fast Assembly
High Brightness Front Servicing
High Refresh

Catalogue
Safety Information 03
Product Introduction 06
About JP Series 06
Product Specifications 08
Basic Wiring Overview for Hanging Installation
Locking System 10
Product Assembly 12
Hanging bar 13
Service and Maintenance 15
Accessories 16
Flight Cases 17

Safety Information
在安装、供
电、运行、调试本产品之前,请务必阅读本节
The following marks on the product and in this manual indicate important safety
measures.
Warning: Be sure to understand and follow all safety guidelines, safety
instructions, warnings and precautions listed in this manual.
This product is for professionals use only!
This product may result in serious injury or death due to fire hazard, electric
shock or on dropping.
Please read this manual carefully before installing, powering up,
operating and maintenance of this product.
Follow safety instructions in this manual and on the product. If you
have any questions, please seek help from Absen.
WARNING!
Please read the Safety Measures listed in this section carefully before
installing, switching on, operating and maintenance of this product.
WARNING!
Safety Risk!
Might cause
equipment
damage
Or safety risk
WARNING!
Please read the
manual before
operating
WARNING!
Dangerous
Voltage!
Might cause
equipment
damage or
electric shock
WARNING!
Hot Surface!
Do not touch
WARNING!
Flammable!
WARNING!
Possible damage
to eyes

Beware of Electric Shock!
⚫To prevent electric shock the device must be properly grounded during
installation. Do not ignore using the grounding plug, or else there is a risk
of electric shock.
⚫During a lightning storm, please disconnect the device’s power supply, or
provide other suitable lightning protection. If the equipment is not in use
for a long time, please unplug the power cord.
⚫When performing any installation or maintenance work (e.g. removing
the fuses, etc.,) make sure to turn off the master switch.
⚫Disconnect AC power when the product is not in use, or before
disassembling, or installing the product.
⚫The AC power used in this product must comply with local building
and electrical codes, and should be equipped with overload and
ground fault protection.
⚫The main power switch should be installed at a location near the
product and should be clearly visible and easily reached. This way in
case of any failure the power can be promptly disconnected.
⚫Before using this product check all electrical distribution equipment,
cables and all connected devices, and make sure all meet current
requirements.
⚫Use appropriate power cords. Please select the appropriate power
cord according to the required power and current capacity, and
ensure the power cord is not damaged, aged or wet. If any
overheating occurs, replace power cord immediately.
⚫For any other questions, please consult a professional.
Beware of Fire!
⚫Use a circuit breaker or fuse protection to avoid fire caused by power
supply cables overloading.
⚫
⚫Maintain good ventilation around the display screen, controller,
power supply and other devices, and keep a minimum 0.1 meter gap with
other objects.
⚫Do not stick or hang anything on the screen.
⚫Do not modify the product, do not add or remove parts.
⚫Do not use the product in case ambient temperature is over 50 ℃.

Beware of Injury!
⚫Warning: Wear a helmet to avoid injury.
⚫Ensure any structures used to support, fix and connect the
equipment, can withstand at least 10 times the weight of all the
equipment.
⚫When stacking products, please hold products firmly to prevent
tipping or falling.
⚫Ensure all components and steel frames are securely installed.
⚫When installing, repairing, or moving the product, ensure the
working area is free of obstacles, and ensure the working platform is
securely and stably fixed.
⚫In the absence of proper eye protection, please do not look directly
at the lit screen from within a 1 meter distance.
⚫Do not use any optical devices that have converging functions to
look at the screen to avoid burning the eyes.
Product Disposal
⚫Any component that has a recycling bin label can be recycled.
⚫For more information on collecting, reusing and recycling, please
contact the local or regional waste management unit.
⚫Please contact us directly for detailed environmental performance
information.
WARNING: Beware of suspended loads.
LED lamps used in the module are sensitive and can be damaged by ESD
(electrostatic discharge). To prevent damage to LED lamps, do not touch
when the device is running or switched off.
WARNING: The manufacturer shall not bear any responsibility for any
incorrect, inappropriate, irresponsible or unsafe system installation.

Product Introduction
About JP Series
JP series products are designed for stage display. It is mainly used in rental
applications for festival and vocal concert, as a medium for video broadcast, result of
exhibition and so on.
JP series includes JP6.25, JP8.33 and JP9.3. The JP series uses aluminum profile +
die-casting aluminum structure and the LED curtain with more than 35%
transparency, greatly reducing wind resistance and better cooling effect. The cabinet
dimension includes 600 X 600 X 100mm, 600 X 1200 X 100mm and 500 X 1000 X
100mm.
600
1200

JP6.25
JP8.33
Up-down lock
Power box
Locating pin
Left-right lock
Up-down lock
Power box
Arc lock
Left-right lock
Power in
Power out
Date in
Date out

Product Specifications
Parameters
JP6.25
JP8.33
JP9.37
Physical
Parameters
Pixels
SMD1515
SMD1921
SMD1515
Pixel Pitch (mm)
6.25
8.33
9.37
Cabinet Pixels
96×96
60×60
64×128
Pixel Density (Pixels / m2)
25600
7200
11377
Module size (L ×W)/(mm)
600×200
500×125
600×150
Panel size (L ×W ×H)/(mm)
600×600×100
600×1200×100
500×1000×100
600×1200×100
Cabinet Material
Aluminum Profile + Die CastingAluminum
Cabinet Weight (㎏/Cabinet)
5.5/8.1
6.5
6.5
Electronic
Parameters
Color Processing Depth (Bit)
14
14
14
Grayscale
16384
16384
16384
Refresh Rate (Hz)
3840
3840
3840
Drive Mode
1/3
1/3
1/4
Picture Frame Frequency
(Hz)
50/60
50/60
50/60
Signal Transmission
Distance (m)
UTP cable:<
100 m;
Single-mode
fiber:<10 km
UTP cable:<
100 m;
Single-mode
fiber:<10 km
UTP cable:<
100 m;
Single-mode
fiber:<10 km
Optical
Parameters
Brightness (nit)
4500
5000
3000
Horizontal Viewing Angle (°)
120
140
140
Vertical Viewing Angle (°)
110
140
120
Electrical
Parameters
AC Input Voltage (V)
100~240
100~240
100~240
AC Input Frequency (Hz)
50/60
50/60
50/60
Power Consumption
(Max./Avg)(W/m2)
750/250
660/220
375/125
Environmental
Parameters
Storage Temperature (˚C)
- 40~+60
- 40~+60
- 40~+60
Working Temperature (˚C)
- 20~+50
- 20~+50
- 20~+50
Storage Temperature (RH)
10%~90%
Non-condensing
10%~90%
Non-condensing
10%~90%
Non-condensing
Working Humidity (RH)
10%~90%
Non-condensing
10%~90%
Non-condensing
10%~90%
Non-condensing
Ingress Protection
IP65/IP54
Product Life (hrs)
100000
100000
100000
Leasing Product
Installation
Cabinet Installation Method
Rigging
Rigging
Rigging
Maximum number of hoisted
cabinets
16
16
16

Basic Wiring Overview for Hanging Installation
Notes:
1、Hanging bars can load a max height of 16 panels.
2、At an input voltage of 220V, one power cable can load 16 panels of JP series ; at an input voltage of 110V, one
power cable can load 8 panels of JP series.
220V-240V
100V-120V

Locking System
Horizontal Locking Procedures

Vertical Locking Procedures

Product Assembly
Procedure
Hanging
Hanging Installation
Fix the Hanging Bar on the Truss
Turn the adjustment screw to make the clamps close. The hanging bar should be directly affixed
to the truss.

Connect and assemble tiles.
Hanging bar
0.5m hanging bar

1m hanging bar

Service and Maintenance
Module Front Maintenance
Easy Maintenance for Power Box
.
Step1: Loosen the screws
used for fixing module
with a cross screwdriver
Step2: Replace a good
module
Step1: Loosen the fixed
bolts from the power
box
Step2: Remove the power
box and maintain it

Accessories
Name:Power Cable
Dimension: 1m
Max Current :16A
Name:long Power Cable
Dimension: 10m
Max Current :16A
Name:Display DATA cable
Dimension: 20m
Name:Panle DATA cabel
Dimension: 1m
Name: Sending card Box
Dimension:
W480×H45×D240mm
Name:Flight case
Max Capacity :12 in 1
Name:Front Maintenance
tool
Name:base stand
Dimension: 0.5M,1M

Flight case
LED panels stored horizontally to prevent SMD damage.
Flight cases are optimised to fit in vehicles for low cost transport. Fully stackable to save space.
12 in 1 design.

All rights reserved by Shenzhen Absen Optoelectronic Co., Ltd.
Shenzhen Absen Optoelectronic Co., Ltd. reserves the rights to modify contents without any further
notice.
Shenzhen Absen Optoelectronic Co., Ltd.
18-20F Building 3A, Cloud Park, Bantian, Longgang District, Shenzhen 518129, P.R.China
T: +86-755-89747399
W: www. absen.com
This manual suits for next models
3
Table of contents
Other Absen Monitor manuals

Absen
Absen XD6 User manual

Absen
Absen CR Series User manual

Absen
Absen HC Series User manual

Absen
Absen X3 User manual

Absen
Absen NX Series User manual

Absen
Absen K Plus Series User manual

Absen
Absen KLCOB V2 Series User manual

Absen
Absen K Series User manual

Absen
Absen A27 Plus Series User manual

Absen
Absen PL Lite Series User manual