LOOPBACK TESTING
Initiate loopback testing from the maintenance screen or use the MODE and SEL
pushbuttons. The inband codes below can also be sent by a test set.
For more information about the maintenance screens, refer to the H2TU-C-319 List 1A
technical practice, document number 152-319-111-xx. Contact Customer Service to obtain
a copy of the practice.
System option pushbuttons (for manual
setting of system parameters)
DSX-1 test access jacks
Card handle
Status LED
Four-character display
Displays status, provisioning, and
alarm messages. See tables below
for a list of message descriptions.
STATUS LEDs report the following conditions:
Use MODE and SEL to manually modify user options,
initiate loopbacks, and display DSX-1 line parameters.
Connect standard test equipment.
Craft port provisioning
To access all system maintenance, provisioning
and performance screens, connect a standard
9-pin terminal cable between the serial port on a PC
and the H2TU-C craft port.
1
2
3
4
Press the MODE pushbutton for 1 second and release.
The front panel alternately displays the first
system parameter and its current setting.
Press SEL to step through all possible settings for
the displayed parameter.
Press MODE to update the parameter and advance
to the next parameter.
After scrolling through all the parameters, press SEL
to confirm changes when prompted with a CONF NO
message, or press MODE to cancel all changes.
LINE Provides splitting jack access to
(IN) and from (OUT) the HDSL2 span
at the DSX-1 interface.
MON Provides non-intrusive monitoring jack
access to (IN) and from (OUT) the
HDSL2 span at the DSX-1 interface.
Allows monitoring of the DS1 payloads.
Modem settings:
S
E
L
M
O
D
E
O
U
T
I
N
M
O
N
M
O
N
L
I
N
E
L
I
N
E
H
2
T
U
*
C
3
1
9
H
D
S
L
2
R
S
2
3
2
SETUP
STATUS
3
4
5
6
C
D
E
F
H7
8
J
9
K
10
L
GND
HDSL2-T HDSL2-R
System alarm Management bus
Frame GND -48V BAT
Fusealarm
Factory useonly
1
A
DSX-1TX-T DSX-1TX-R
2
B
DSX-1 RCV-T1 DSX-1RCV-R1
Card-edge connector
List number
A Customer Remote (CREM)
or Network Local (NLOC)
loopback is in effect.
Green LED Normal operation.
Red LED Fuse alarm.
Flashing Red LED
Yellow LED
FlashingYellow LED System is in Armed (ARM)
mode.
Off Line power is off.
(ECI bar code
label on outside
of handle)
1A
HDSL2 acquisition or
system alarm.
Alternating green and
red LED
Alternating yellow and
red LED
Host alarm reporting is
disabled.
System alarm and host alarm
reporting is disabled.
HiGain
HDSL2
DCE
9600 baud
8 data bits
No parity
1 stop bit
Hardware flow control:OFF
Terminal emulation:VT100
GNLB Loopback Commands
Loopback Inband Code Description
NLOC 1111000 DSX-1 signal is looped back to the network at the H2TU-C.
NREM 1110000 DSX-1 signal is looped back to the network at the H2TU-R.
SMJK 11000 DSX-1 signal is looped back to the network at the H2TU-R
SmartJack module.
CREM 1111110 DS1 signal from customer is looped back to the customer
at the H2TU-C.
CLOC 1111100 DS1 signal from customer is looped back to the customer
at the H2TU-R.
Loopdown 11100 Deactivates any of the above loopbacks.
Front-Panel Alarm Messages(a)
(a) Front-panel alarm messages are listed in order of priority. ALRM displays prior to any alarm message.
Pressing the SEL button initiates an Alarm Cutoff (ACO) message.
Message Description
PWR FEED SHRT (b)
(b) Message displays repeatedly as long as the alarm condition exists and is not included in the priority order.
A short between the Tip and Ring of the HDSL2 pair.
PWR FEED GND (b) The HDSL2 loop is grounded.
PWR FEED OPEN (b) A line-power open condition.
SPNn-LOSW The HDSL2 loop has lost synchronization. The span closest to the network has highest
priority.
LLOS No signal is detected at the DSX-1 input to the H2TU-C.
RLOS No signal is detected at the DS1 input to the H2TU-R.
LAIS (c)
(c) Does not activate the alarm relay access pin H.
Line Alarm Indication Signal.
RAIS (c) Remote Alarm Indication Signal.
TRCI (c) An RAI alarm (yellow LED) from the CPE with an error-free signal from the line unit or
network.
RRAI(c) An RAI alarm (yellow LED) from the Customer Premises Equipment (CPE) with errors
from the line unit or network.
xxx-LOF The DS1 input does not contain the ESF or SF frame pattern setting of the FRMG option.
(xxx denotes either TUC or TUR.)
xxx-DBER (c) A system DS1 Bit Error Rate (BER) alarm. (xxx denotes either TUC or TUR.)
PRMF (c) H2TU-R Performance Report Messaging BER threshold exceeded at far end.
PRMN (c) H2TU-R Performance Report Messaging BER threshold exceeded at near end.
xxx-HBER A system HDSL2 Block Error Rate (BER) alarm. (xxx denotes either TUC or TUR.)
xxx-MAL The margin on the HDSL2 loop has dropped below the threshold setting. (xxx denotes
either TUC or TUR.)
xxx-LA The attenuation on the HDSL2 loop has exceeded the maximum threshold value. (xxx
denotes either TUC or TUR.)
To comply with the intrabuilding wiring requirements of
GR-1089 CORE, Section 4.5.9, the shields of the ABAM-type
cables that connect the H2TU-C-319 List 1A DSX-1 output ports
to the cross-connect panel must be grounded at both ends.
Network
Customer
Premises
H2TU-C H2TU-R
TLOS*
NLOC CREM CLOC
1111000 NREM
1110000 1111100
1111110
11000
SMJK
When enabled,TLOS is an automatic loopback
that occurs with an LOS at the remote DS1 input.
*
DS1DSX-1
Front-Panel Diagnostic Messages
Display Code Description (normal operating messages in bold)
A=xx The loop attenuation of the longest (maximum loss) span, measured in dB.
ACQ The multiplexers of the H2TU-C-319 and H2TU-R are trying to establish synchronization.
AnL The multiplexers of the two devices on Span n are trying to establish synchronization with
each other, where nis the number of the span.
ARM Armed to respond to Intelligent Repeater Loop (ILR) codes.
BAD RT? The H2TU-C is not receiving a response from the H2TU-R.
FERR A framing bit error occurred at H2TU-C DSX-1 input.
FLDL Flash download of firmware updates. (Contact Customer Service for update procedures.)
HES H2TU-C HDSL2 loop cyclical redundancy check (CRC) error.
LBPV A local bipolar violation has been received at the DSX-1 input to the H2TU-C.
M=xx Indicates the power of the received HDSL2 signal relative to noise (S/N with respect to
21.5 dB). Any value of 6 dB or greater is adequate for reliable system operation.
MNGD The H2TU-C is under control of the HMU-319 network management unit.
PWR FEED OFF HDSL2 span power is turned off.
PWR FEED ON Indicates that the HDSL2 loop is not grounded or shorted.
SIG The transceivers of the H2TU-C and H2TU-R are trying to establish contact with each
other on Span 1 of the HDSL2 loop.
SnL The transceivers of the two devices on Span nare trying to establish contact with each
other, where nis the number of the span.
Front-Panel Configuration Options Using MODE and SEL(a)
(a) Front-panel configuration options display in the order listed.
Display Code Description (default values in bold)
EQL Sets the DSX-1 Equalizer to: 0(0 to 132 ft.), 133 (133 to 265 ft.), 266 (266 to 398 ft.),
399 (399 to 532 ft.), 533 (533 to 655 ft.).
RLBO Sets the H2TU-R line buildout to 0 dB, -7.5 dB, or 15 dB.
LPBK Enables (ENA) or disables (DIS) SmartJack loopback commands.
SPLB xxxx Configuressystem for generic (GNLB) or special inband loopback commands (A1LB, A2LB, A3LB,
A4LB, A5LB).
PWRF OFF = disables HDSL2 powering; ON = HDSL2 line voltage is -185 Vdc maximum.
HBER 1E-6 or 1E-7 = alarm activates when the HDSL2 BER alarm threshold exceeds 10-6 or 10-7.
NONE = prevents generation of a system alarm due to BER.
DBER Enables (ENA) or disables (DIS) fixed 24-hour DSX-1 BER alarm threshold.
LBTO Loopback timeout = NONE, 20, 60, 120 minutes.
ALM Enables (ENA) or disables (DIS) alarm indications on pin H.
DS1 DSX-1 line code = AUTO, B8ZS, AMI.
FRMG DS1 frame formatting = AUTO (auto framing mode), SF (SuperFrame), ESF (Extended
SuperFrame), or UNFR (unframed mode).
RDA Enables (ENA) or disables (DIS) alarm indications due to remote DS1 LOS at H2TU-R input.
ALMP Enables system to output an alarm pattern: AIS or LOS.
BPVT Enables (ENA) or disables (DIS) Bipolar Violation Transparency.
NLBP Enables the H2TU-R to transmit either AIS or LOS towards CI for any network loopback.
TLOS Enables (ENA) or disables (DIS) a logic loopback at the H2TU-R when an LOS occurs at its
DS1 input.
RTPV Enables (ENA) or disables (DIS) remote provisioning.
NAIS If ALMP is set to AIS, this option specifies which pattern is sent to the network when a
remote LOS or AIS occurs. CI = AIS-CI sent to the network; AIS = AIS sent to the network.
RACI Enables (ENA) or disables (DIS) conversion of a DS1 SF-RAI signal received by the H2TU-R
to an SF-RAI-CI signal towards the network.
Front-Panel System Information Messages (Scroll Mode)(a)
(a) To scroll through system information messages, press the MODE button for 3 or more seconds.
Code Description Code Description
CODE xxxx Line code setting (AMI or B8ZS). LIST xx List number of the H2TU-C-231.
FRM xxxx Frame pattern received from the
DSX-1 (SF, ESF, UNFR). MARG xx Margin threshold (0 to 15 dB).
Default is 4.
LATT xx Loop attenuation (0 to 40 dB).
Default is 35. VER x.xx Software version number.