ADE Captiv8-256 User manual

Captiv8-256
Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04 1
Captiv8-256
User Manual
The purpose of this manual is to describe how to use the Captiv8-256 intruder alarm a system.
Some of the features described in this guide may not be applicable to your installation and should
be ignored. The engineer from the alarm company will have completed the System Information in
this booklet that gives information specific to your installation. You will need to refer to this as you
read these instructions in order to check if certain features have been used. If in any doubt, consult
you alarm company.
Alarm Company (Installer name): ___________________________
Telephone Number:_______________________________________
Account Number:_________________________________________
Installation Date: _________________________________________
Thursday 06-May
09:37:00

Engineering Manual
2 Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04
Contents
Contents 2
1) Introduction 4
a) The Captiv8 Keypad 4
b) Warning Indications 6
c) Using Tags 6
d) Leaving the Building 7
i) Timed Exit 7
ii) Manual Setting 9
2Using the Keypad with PIN Code or Tag 10
a) Security Checks 10
i) Faults When Switching On 10
b) Leaving the Building 11
c) Entering the Building 11
d) Part-Setting the System 11
i) Smart Set 11
e) Staying in the Building 12
3When Problems Arise 13
a) Silencing Alarms 13
b) Engineer Reset 13
4Setting Individual Areas 14
a) Codes with Flexi-Set 14
b) Flexi-Set 15
5More Advanced Functions 16
a) Ignoring an Open Door or Window 16
b) Omitting a Zone when Leaving the Building 17
c) Keypad Personal Attack 18
6Manager Menu 19
a) Omit Zones 20
b) Changing Date and Time 21

Captiv8-256
Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04 3
c) Changing or Adding PIN Codes or Tags 22
d) Changing or Adding PIN Codes or Tags 23
e) Changing or Adding New PIN Codes or Tags 24
f) Review History Logs 26
g) Check all Detectors are Working 27
h) Testing the Alarm Sounders 27
7SMS Messaging System 29
a) Menu Exit 29
8Service Information 31
a) User Codes 32

Engineering Manual
4 Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04
1) Introduction
a) The Captiv8 Keypad
This is the Keypad from where the alarm system is controlled.
Figure 1 The Keypad Keypad1.wmf
The display shows any important messages, including an alert to call the alarm
installation engineer.
The 10 digit numeric keypad is where the PIN code is entered.

Captiv8-256
Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04 5
Figure 2 Numeric keys Keypad3.wmf
The A B C D keys help to simplify usage.
Figure 3 ABCD keys Keypad3.wmf
MAINS FAIL
The numeric
keys
NOVAR PLC
TIME
The ABCD keys

Engineering Manual
6 Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04
The illustration below shows the ward reader where the tag is offered up.
Figure 4 Ward Reader WardReader2.wmf
b) Warning Indications
All setting points (keypads or ward readers) have lamps to indicate the current
status.
Lamp Indicatiing
Power The lamp will flash if the mains supply fails
Alarm The lamp will flash if an alarm occurs.
Set/Unset The lamp will light for 5 seconds if the system is completely unset
(steady) or if some areas remain set (flashing). It will also light during
the setting procedure and go off once set.
c) Using Tags
The high security proximity tag will set or unset the alarm system in a
straightforward manner.
The bottom panel.
Tags are offered up
here to be read.
The top panel.
This is where the LED
indicators are located.

Captiv8-256
Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04 7
The tag contains no batteries and is completely maintenance free.
Offer the tag to the bottom panel on the ward reader for it to be read, when
the reader will beep to acknowledge the tag.
Before activating the system…
Ensure that all doors and windows are securely closed and any pets or people
are excluded from areas protected by movement sensors.
d) Leaving the Building
If leaving the building, key in the PIN code on the keypad or present the tag at
the reader.
On completion, the exit tone will sound.
There are now two possible procedures that can be used to set the system.
• Timed Exit
• Manual Setting
Whichever method is used, this will be referred to as the setting procedure in
later text.
i) Timed Exit
If the exit mode is timed, the screen shown below will be displayed. This allows
a preset time for the operator to leave the building before the system becomes
set.

Engineering Manual
8 Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04
Figure 5 Exit Timer Keypad3.wmf
If a push-to-set button, or a final door set is used, the following message will be
displayed.
Figure 6 Designated Route Message Keypad3.wmf
SETTING[009]
OFFICE
Exit timer
EXIT VIA DESIG ROUTE

Captiv8-256
Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04 9
If flexi-set is enabled, the settable areas will be selectable. (See chapter 5
More Advanced Functions on page 16.)
ii) Manual Setting
With this method, the system is set by closing the final exit door, or by pressing
a push-to-set button outside the building, near the final door. The message
displayed is …
EXIT VIA DESIG ROUTE

Engineering Manual
10 Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04
2 Using the Keypad with PIN
Code or Tag
a) Security Checks
If a warning tone sounds when the PIN code is keyed in or the tag is presented,
a message will show the nature of the problem.
The tone will cease after about 10 seconds.
Press the NO key.
The system will remain unset, so that the problem can be resolved.
For example, a door may have been left open. If this is the case, close the door.
With the problem corrected, repeat the setting procedure.
i) Faults When Switching On
If the exit tone continues to sound an interrupted tone... "beep - beep - beep - "
after the setting procedure has been completed, there is probably a protected
door left open on the exit route.
Return to the keypad and note the message on the display. E.g.
EXIT VIA HALLWAY
Stop the setting procedure by entering the PIN code, or offering up the tag.
Close the open door and repeat the setting procedure.

Captiv8-256
Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04 11
b) Leaving the Building
If leaving the building, go to the Keypad and key in the PIN code, or present the
tag. The exit tone will start.
Leave by the agreed exit route and close and lock the final exit door.
If fitted, press the 'Push to Set' button and the exit tone will cease. Captiv8-256
is now set.
c) Entering the Building
To enter the building the agreed entry route must be used, moving directly to
the keypad.
Entry tone will sound, “Beep - beep - beep -…”
ENTRY [020]
TIME
Key in the PIN code or present the tag and the entry tone will cease.
Captiv8-256 is now unset.
d) Part-Setting the System
i) Smart Set
To set the system while personnel remain in the building (e.g. to set the alarm
at night), the Smart operating system will recognise the level of security
required and will set only part of the system.
If partial setting is required the Push-to-Set button will not need to be used.

Engineering Manual
12 Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04
e) Staying in the Building
To part-set the system, enter the PIN code at the keypad or present the tag to
the ward reader and the exit tone will start.
Leave the protected area and go immediately to the un-protected area (e.g.
upstairs).
After a preset time the exit tone will cease.
The system is now part set.

Captiv8-256
Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04 13
3 When Problems Arise
a) Silencing Alarms
If an alarm tone sounds, key in the PIN code or present the tag and the alarm
will stop sounding.
The display will indicate the problem.
ALARM SILENCE
LOW VOLTS
Press the 'YES' Key
The system will advise any action that is needed.
b) Engineer Reset
When an alarm has been cancelled, a random 5-digit code may be displayed,
along with the message…
ENGINEER RESET REQUIRED
21055
Under these circumstances, it is normally necessary for an engineer from the
installation company to check the installation and reset the system.
If the alarm has been triggered in error, the alarm receiving centre may permit a
reset of the system without an engineer being present.
The centre will need to be notified of the 5-digit code by telephone (advising
the agent that the system is a Captiv8-256). The alarm receiving centre will then
issue a one-use code that can be used to reset the system.

Engineering Manual
14 Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04
4 Setting Individual Areas
Sometimes, security needs will be a little more complex and the A B C D keys
will need to be used.
The Installer can identify to all of the A B C D areas.
For example…
A Reception or All Set
B Warehouse or Bedtime Set
C Office or Cat in Lounge
D Storeroom or Dog in Study
SETTING
RECEPTION
In addition, names can be given to the whole system. E.g. 'ALL AREAS'.
SETTING
ALL AREAS
These will be displayed when setting the system.
a) Codes with Flexi-Set
For greater flexibility in setting parts of the system, choices can be made at the
keypad.
SET AREAS
[ABCD]
Key in the PIN code or present the tag.
If only some of the areas assigned to the tag or PIN number are to be set, select
those required by pressing the relevant A, B, C D keys.

Captiv8-256
Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04 15
To alter the selection, press the relevant A B C D keys again.
Press the Yes key to accept the selection.
Setting areas will be displayed.
SETTING
ALL AREAS
Captiv8-256 will now set the selected areas.
b) Flexi-Set
When the system is already set and it is required to unset it…
Key in the PIN code or present the tag.
NOVAR PLC
TIME:
All areas for which the tag or PIN is valid will be Unset. Any areas set for which
the code is not valid will remain set. E.g. if A and B are set…
If an 'A' tag is presented, only area A will be unset.
If an 'A B' tag is presented, both A & B will be unset.
An 'A B C' tag will unset A & B, leaving C unset.
If there are no areas set for which the code is valid, the system will set as
described in chapter 5 More Advanced Functions on page 16.

Engineering Manual
16 Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04
5 More Advanced Functions
a) The Chime FacilityThe 'C' key can be used to select the 'chime' facility
while the system is Unset.
For example, an alert is to sound if someone enters through a particular door
during the day.
NOVAR PLC
TIME:
Press the 'C' key.
The display will show a 'C'
NOVAR PLC
TIME: C
If the door opens the 'chime' tone will occur.
To cancel the 'Chime' function, press 'C' again.
NOVAR PLC
TIME:
a) Ignoring an Open Door or Window
In a domestic setting it may be necessary to ignore windows deliberately left
open in the summer-time.
Enter the PIN code or present the tag.

Captiv8-256
Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04 17
The display will ask if a window is to be left open.
To omit the window Press 'YES' (or 'NO' if it is not to be omitted.)
LEAVE OPEN?
BEDRM WINDOW
The system will then set as normal.
The window will be omitted for this one arming period only.
Only doors or windows already open can be omitted in this way.
b) Omitting a Zone when Leaving the
Building
It may be occasionally necessary to isolate a detector if a room is occupied.
To do this, enter the PIN code or tag.
NOVAR PLC
TIME:
While the exit tone is sounding press the 'YES' key.
OMIT ZONE?
When the 'OMIT ZONE' menu is displayed…
Key in the number of the zone to omit and press 'YES'.
Always use a leading zero; e.g. 02 is zone 2. On larger systems
002 is zone 2.
Accepted zones will be displayed on the screen.
Repeat for any other zones that need to be omitted.

Engineering Manual
18 Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04
After 10 seconds Captiv8-256 will begin to set.
Zones set in this way will be omitted for this one period only.
c) Keypad Personal Attack
Captiv8-256 allows personal assistance to be summoned in an emergency.
To do this, press the two PA keys at the same time.
To reset…
Enter the PIN code or present the tag.
This facility is only available if it has been enabled by the alarm
installer. It can also send a signal to the Alarm Receiving Centre.

Captiv8-256
Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04 19
6 Manager Menu
NOVAR PLC
TIME:
To enter Manager Menu, key in the manager PIN code.
SET SYSTEM?
The system must be fully disarmed in order to enter the manager menu.
The master manager code can only give access to the manager
menu, and will not set or unset the system.
The manager menu has a choice of…
• Set System?
• Set Time & Date?
• Omit Zones?
• Change Codes?
• Review Events?
• Walk Test?
• Bell Test?
• Engineer Menu?
• Exit Manager Menu?
Pressing the 'NO' key will move the selection from one menu item to the next (as
well as escaping from within a menu).
Pressing the 'YES' key will take you into a menu (as well as accepting a choice
within a menu).

Engineering Manual
20 Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04
With the system Unset…
Key in the Manager PIN code.
SET/UNSET SYSTEM?
To set the Captiv8-256 system, press 'YES'. To move on to another menu item
press 'NO'.
a) Omit Zones
Press 'NO'.
SET DATE AND TIME[--]
Press 'NO'.
OMIT ZONES[--]
Some of doors may be used only rarely. Opening them, even with the system
unset, may cause an alarm. To open these doors safely, omit them from the
system as shown below.
Enter the zone number to omit.
OMIT ZONES?[06]
FIRE DOORS
Press 'YES'
To reinstate zones, key in the number again.
Press 'YES'