ADJ HYDRO WASH X19 User manual

HYDRO WASH X19
User Manual

2
©2022 ADJ Products, LLC
instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product
names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes
all forms and matters of copyrightable materials and information now allowed by statutory or judicial
law or hereinafter granted. Product names used in this document may be trademarks or registered
trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC
brands and product names are trademarks or registered trademarks of their respective companies.
ADJ Products, LLC
equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic
loss associated with the use or reliance of any information contained within this document, and/or as a
of this product.
ADJ USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
ADJ Supply Europe B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
ADJ Mexico | AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000
+52 (728) 282-7070
DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of this
document may be available online.
Please check www.adj.com for the latest revision/update of this manual
Date Document
Version
Software
Version DMX Channels Notes
06/29/2020 1.0 1.1 16 / 88 / 90 Initial Release
08/13/2020 1.1 NC No Change Updated System menu / error codes
10/08/2020 1.2 NC No Change Updated zoom range value
07/14/2021 1.3 1.2 16 / 26 / 88 / 90
Added 26-ch DMX mode; added Pixel
Zones; updated Features, Safety
Guidelines, Fixture Installation, System
Menu, & Technical Specs
08/10/2021 1.4 N/C No Change
Updated Overview, System Menu, WiFly
Control, and Specifications, removed
Software Updates
03/07/2022 1.5 3.0 16 / 20 / 26 / 30 / 88 / 90 Updated Features, System Menu, DMX
Addressing, DMX Traits, Specifications.
05/13/2022 1.6 N/C No Change Updated Overview, Pixel Zones, System
Menu.
12/13/2022 1.7 N/C N/C

3
CONTENTS
Introduction 4
Limited Warranty 5
IP65 Notice 6
Safety Guidelines 7
Overview 10
Torque Settings & IP Tester 11
Torque Screw Locations 12
Fixture Installation
Omega Bracket & Truss Clamp
Truss Installation
Direct Light Source
Connecions
13
14
15
16
17
Remote Device Management (RDM) 18
DMX Setup 19
DMX Addressing 20
Color Macro Chart 21
Color Temperature Chart 23
Pixel Zones 24
System Menu 25
WiFly Control 32
Target Modes 34
Dimmer Curve Chart 36
DMX Traits 37
Error Codes 42
Multiple Unit Power Linking | Cleaning 43
44
Dimensions 45
FCC Statement 46

4
GENERAL
INTRODUCTION
followed. Please read and understand all the instructions and guidelines carefully and thoroughly before
operating this unit. This manual contains important information regarding safety, installation, use, and
maintenance.
UNPACKING
the outer shipping carton for signs of any damage that may have occurred during shipping. If the
accessories have arrived intact. In the event damage has been found and/or parts are missing, please
outer shipping carton in the trash. Please recycle whenever possible.
FEATURES
IP65 Outdoor Rated
Electronic Dimming 0-100%
DMX-512 Protocol
IP65, 5-pin XLR, Data Locking In/Out Connections
16, 20, 26, 30, 88, & 90 Channel DMX Control Modes
IP65 Locking Power In/Out Connections
6°to 40°Motorized Linear Zoom
Multiple Unit Power Linking (see section on Multiple Unit Power Linking)
INCLUDED ITEMS
• IP65 Locking Main Power Cable (1x)
• Omega Brackets (x2)
CUSTOMER SUPPORT: Contact ADJ Service for any product related service and support needs. Also visit
forums.adj.com with questions, comments or suggestions.
ADJ SERVICE USA - Monday - Friday 8:00am to 4:30pm PST
ADJ SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET
REPLACEMENT PARTS please visit parts.adj.com
WARRANTY RETURNS
All returned service items, whether under warranty or not, must be freight pre-paid and accompanied
by a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of
the return package. A brief description of the problem as well as the R.A. number must also be written
down on a piece of paper and included in the shipping container. If the unit is under warranty, you must
provide a copy of your proof of purchase invoice. Items returned without an R.A. number clearly marked
R.A. number by contacting customer support.

5
LIMITED WARRANTY (USA ONLY)
A. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be
free of manufacturing defects in material and workmanship for a prescribed period from the date
of purchase (see specific warranty periods below). This warranty shall be valid only if the product
is purchased within the United States of America, including possessions and territories. It is the
time service is sought.
B. For warranty service you must obtain a Return Authorization number (RA#) before sending back
the product–please contact ADJ Products, LLC Service Department at 800-322-6337. Send
the product only to the ADJ Products, LLC factory. All shipping charges must be pre-paid. If the
requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ
Products, LLC will pay return shipping charges only to a designated point within the United States.
If the entire instrument is sent, it must be shipped in its original package. No accessories should be
shipped with the product. If any accessories are shipped with the product, ADJ Products, LLC shall
have no liability whatsoever for loss of or damage to any such accessories, or for the safe return
thereof.
C. This warranty is void if the serial number has been altered or removed; if the product is modified
in any manner which ADJ Products, LLC concludes, after inspection, affects the reliability of the
product; if the product has been repaired or serviced by anyone other than the ADJ Products, LLC
factory unless prior written authorization was issued to purchaser by ADJ Products, LLC; if the
product is damaged because not properly maintained as set forth in the instruction manual.
D. This is not a service contract, and this warranty does not include maintenance, cleaning or periodic
checkup. During the period specified above, ADJ Products, LLC will replace defective parts at its
expense with new or refurbished parts and will absorb all expenses for warranty service and repair
labor by reason of defects in material or workmanship. The sole responsibility of ADJ Products,
LLC under this warranty shall be limited to the repair of the product, or replacement thereof,
including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty
were manufactured after August 15, 2012, and bear identifying marks to that effect.
E. ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its
products without any obligation to include these changes in any products theretofore manufactured.
No warranty, whether expressed or implied, is given or made with respect to any accessory
supplied with products described above. Except to the extent prohibited by applicable law, all
implied warranties made by ADJ Products, LLC in connection with this product, including warranties
of merchantability or fitness, are limited in duration to the warranty period set forth above. And no
warranties, whether expressed or implied, including warranties of merchantability or fitness, shall
shall be such repair or replacement as is expressly provided above; and under no circumstances
shall ADJ Products, LLC be liable for any loss or damage, direct or consequential, arising out of the
use of, or inability to use, this product. This warranty is the only written warranty applicable to ADJ
Products, LLC Products and supersedes all prior warranties and written descriptions of warranty
terms and conditions heretofore published.
LIMITED WARRANTY PERIODS
• Non-LED Lighting Products = 1-Year (365 Days) (Including Special Effect Lighting, Intelligent
Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par Cans, Trussing,
Lighting Stands, Power/Data Distribution, etc. excluding LED and lamps)
• Laser Products = 1-Year (365 Days) (excluding laser diodes which have a 6-Month Limited
Warranty)
• LED Products = 2-Year (730 Days) (excluding batteries which have a 180 Day Limited Warranty)
PLEASE NOTE: 2-Year (730 Days) Limited Warranty ONLY applies to product purchased
within the USA.
• StarTec Series = 1-Year (365 Days) (excluding batteries which have a 180 Day Limited Warranty)
• ADJ DMX Controllers = 2 Year (730 Days)
• American Audio Products = 1 Year (365 Days)

6
IP65 RATED
designed with an enclosure that effectively protects the ingress (entry) of external foreign objects such as
dust and water. The International Protection (IP) rating system is commonly expressed as “IP” (Ingress
against the ingress of dust (6) and low-pressure water jets from any direction (5).
NOTE: THIS FIXTURE IS INTENDED FOR TEMPORARY OUTDOOR USE ONLY!
MARINE/COASTAL ENVIRONMENT INSTALLATIONS
NOT
and/or coastal environment may cause corrosion and/or excessive wear to the interior and/or exterior
and/or coastal environment will void the manufactures warranty and will NOT be subject to any warranty
claims and/or repairs.

7
SAFETY GUIDELINES
For Your Own Personal Safety, Please Read and Understand This Manual Completely Before
You Attempt To Install Or Operate This Unit!
• THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY
DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE
DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE
AND/OR REPAIRS.
• DO NOT PLUG THE FIXTURE INTO A DIMMER PACK!
• NEVER OPEN THIS FIXTURE WHILE IN USE!
• UNPLUG POWER BEFORE SERVICING FIXTURE!
• NEVER TOUCH THE FIXTURE DURING OPERATION AS IT MAY BE HOT!
• KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
• ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC
GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER
CORROSION AND/OR ELECTRICAL SHORT CIRCUIT.
• IF THE FIXTURE IS EXPOSED TO ENVIRONMENTAL TEMPERATURE CHANGES, SUCH AS
RELOCATION FROM AN OUTDOOR COLD TO AN INDOOR WARM ENVIRONMENT, DO NOT
POWER THE FIXTURE ON IMMEDIATELY. INTERNAL CONDENSATION AS A RESULT OF
ENVIROMENTAL TEMPERATURE CHANGE CAN CAUSE INTERNAL FIXTURE DAMAGE.
LEAVE THE FIXTURE POWERED OFF UNTIL IT HAS REACHED ROOM TEMPERATURE
BEFORE POWERING ON.
• NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY INDUCE
BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!
• Be sure that the power outlet matches the required voltage for your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken.
• Do not attempt to remove or break off the ground prong from the electrical cord. This prong is used
to reduce the risk of electrical shock and fire in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover fro any reason. There are no user serviceable parts inside.
• Never operate this unit with the cover removed.
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 7.9”
(20cm) between this device and a wall.
• Do not attempt to operate this unit if it has been damaged in any way.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items
placed upon or against them, paying particular attention to cords at plugs, convenience receptacles,
and the point at which they exit from the appliance.
• Cleaning - The fixture should be cleaned only as recommended by the manufacturer. See the
Cleaning section of this manual for details.
• Heat - This fixture should be situated away from heat sources such as radiators, heat registers,
stoves, or other appliances (including amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when the appliance does not appear to
operate normally or exhibits a marked change in performance.

8
SAFETY GUIDELINES
To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual.
will void the original manufactures warranty and increase the risk of damage and/or personal injury.
PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT
ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES
WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE
AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS
MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY
WARRANTY CLAIMS AND/OR REPAIRS.
DO NOT PLUG FIXTURE INTO A DIMMER PACK!
NEVER OPEN THIS FIXTURE WHILE IN USE!
UNPLUG POWER BEFORE SERVICING FIXTURE!
NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT!
KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH
A DIELECTRIC GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO
PREVENT WATER CORROSION AND/OR ELECTRICAL SHORT CIRCUIT.
IF THE FIXTURE IS EXPOSED TO ENVIRONMENTAL TEMPERATURE CHANGES SUCH
AS RELOCATION FROM AN OUTDOOR COLD TO AN INDOOR WARM ENVIRONMENT,
DO NOT POWER THE FIXTURE ON IMMEDIATELY. INTERNAL CONDENSATION AS
A RESULT OF ENVIRONMENTAL TEMPERATURE CHANGE CAN CAUSE INTERNAL
FIXTURE DAMAGE. LEAVE THE FIXTURE POWERED OFF UNTIL IT HAS REACHED
ROOM TEMPERATURE BEFORE POWERING ON.
NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY
INDUCE BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!

9
SAFETY GUIDELINES
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow approximately 15
minutes for the fixture to cool down before servicing.
DO NOT shake fixture, and avoid brute force when installing and/or operating fixture.
DO NOT operate fixture if the power cord has become frayed, crimped, damaged and/or if any of the
power cord connectors are damaged and do not insert into the fixture securely with ease.
NEVER force a power cord connector into the fixture. If the power cord or any of its connectors are
damaged, replace it immediately with a new one of the same power rating.
DO NOT block any air ventilation slots; these must remain clean and never blocked. Allow approx. 7.9”
(20cm) between fixture and other devices or a wall for proper cooling.
When installing fixture in a suspended environment, always use mounting hardware that is no less
than M10 x 25 mm, and always attach an appropriately rated safety cable.
ALWAYS disconnect fixture from main power source before performing any type of service and/or
cleaning procedure. Only handle the power cord by the plug end; never pull out the plug by tugging
the wire portion of the cord.
During the initial operation of this fixture, a light smoke or smell may emit from the interior of the
fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off
from the heat associated with the LED and will decrease gradually over time.
Consistent operational breaks will ensure fixture will function properly for many years.
ONLY use the original packaging and materials to transport the fixture in for service.

10
OVERVIEW
UP Button
ENTER Button
LCD Menu Control Display
IP65 Locking
5-Pin DMX In/Out
Gore Valve
IP65 Locking
Power Connector
In/Out
DOWN Button
MENU Button
Fuse: T 10A
Service Port

11
# Screw Locations Screw Torque Settings
1 Heat Sink to Head Front Cover (x8) 7.5-10.0 In-Lb
2 Sealed Back Cover to Head Back Cover (x4) 7.5-10.0 In-Lb
3 Yoke Arm Cover to Yoke Frame (8 x Each Side = 16 Total) 7.5-10.0 In-Lb
4 Access Cover to Yoke Frame (x4) 7.5-10.0 In-Lb
5 2nd Access Cover to Yoke Frame (x8) 7.5-10.0 In-Lb
6 Power & Data Connector to Base Casting (x10) 6.0-8.5 In-Lb
7 Handle to Base Casting (2 x Each Side = 4 Total) Fasten by Air Screwdriver
8 Base Bottom Cover to Base Casting (x12) 7.5-10.0 In-Lb
9 Quick Lock Plate to Base Bottom Cover (x16) 7.5-10.0 In-Lb
10 Fixture Feet to Base Bottom (x4) 6.0-8.5 In-Lb
TORQUE SCREWS & IP TESTER
ALL SCREWS MUST BE TIGHTENED WITH A TORQUE DRIVER. All screws are Allen Head screws.
Please see below for screw locations, screw quantity and torque settings. The number listed in the “#”
for SCREW LOCATION depictions.
TORQUE DRIVERS (Recommended): UTICA TS-30 (Shown)
ALTERNATIVE DRIVERS:
Proto J6107A
Wiha 28887
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE
ISSUES! TO CONFIRM THE IP65 INTEGRITY AFTER MAINTENANCE, TEST THE
FIXTURE USING THE ADJ IP TESTER. CONTACT ADJ SERVICE FOR MORE
DETAILS.

12
TORQUE SCREW LOCATIONS

13
FIXTURE INSTALLATION
FLAMMABLE MATERIAL WARNING
pyrotechnics, etc.
ELECTRICAL CONNECTIONS
installations.
MINIMUM DISTANCE TO OBJECTS/SURFACES MUST BE 40 FEET (12 METERS)
MAXIMUM TEMPERATURE OF EXTERNAL SURFACE 167°F (75°C)
DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!
Fixture MUST be installed following all local, national, and country commercial electrical and construction
cables, and accessories.
appropriately rated safety cable that meets all local, national, and country codes and regulations.
Fixture ambient operating temperature range is -4°F to 104°F. (-20°C to 40°C)
outside this temperature range.
Fixture should be installed in areas outside walking paths, seating areas, or away from areas were

14
Screw one clamp via an M12 screw and nut into the Omega Bracket. Insert the quick-lock fasteners
of the Omega Bracket into the respective holes of the fixture base plate. NOTE: The clamp must be
attached to the Omega Bracket before attaching the bracket to the fixture. Tighten the quick-
lock fasteners fully clockwise. Pull the safety-cable through the openings located on the bottom of the
unit and over the trussing system or a safe fixation spot. Insert the end in the carabiner and tighten
the safety screw.
NEVER stand directly below the fixture when rigging, removing, or servicing.
Always allow approximately 60 minutes for the fixture to cool down before servicing.
FIXTURE INSTALLATION

15
FIXTURE INSTALLATION
The trussing or area of installation must be able to support at least 10 times the weight without any
deformation. The unit must be secured with a secondary safety attachment, such as an appropriately
rated safety cable. Never stand directly below the unit when mounting, removing, or servicing the unit.
Overhead mounting requires extensive experience, including calculating working load limits,
installation material being used, and periodic safety inspection of all installation material and the unit.
If you lack these qualifications, do not attempt the installation yourself.
The installation should be checked by a skilled person once a year.
The Hydro Wash X19 is fully operational in three different mounting positions: hanging upside-down,
mounted sideways on trussing, or set on a flat level surface. Always use and install a safety cable as
a safety measure to prevent accidental damage and/or injury in the event the clamp fails. Never use
the carrying handles to secure the secondary attachment.
SIDE MOUNTING
TO MAINTAIN IP65 RATING
INSTALLED WITH CABLES FACING
THE GROUND AT ALL TIMES.
NOT COLLECT AROUND CABLE
CONNECTIONS.
SAFETY CABLE
CABLE WHENEVER INSTALLING
THIS FIXTURE IN A SUSPENDED
ENVIRONMENT TO ENSURE THE
FIXTURE WILL NOT DROP IF THE
CLAMP FAILS.
LCD
CONTROL
CABLES
DOWN
LCD
CONTROL
CABLES
DOWN

16
SAFETY GUIDELINES
POTENTIAL INTERNAL FIXTURE DAMAGE FROM EXTERNAL SOURCES OF LIGHT BEAMS
are focused directly towards the exterior housing and/or penetrate the front lens opening of ADJ lighting
lamps, and LEDs.
manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines
below can prevent any potential damage from occurring if followed. Contact ADJ Service for more details.
DO NOT EXPOSE THE FIXTURE AND/OR FRONT LENS OPENING TO LIGHT BEAMS FROM
DIRECT SUNLIGHT, OTHER LIGHTING MOVING HEAD FIXTURES, AND LASERS WHILE
UNPACKING, INSTALLATION, USE, AND EXTENDED IDLE TIMES OUTDOORS.
DO NOT FOCUS A LIGHT BEAM FROM ONE LIGHTING FIXTURE DIRECTLY TOWARDS ANOTHER.

17
FIXTURE INSTALLATION
ENSURE ALL CONNECTIONS AND END CAPS ARE PROPERLY SEALED WITH A DIELECTRIC
GREASE (AVAILABLE AT MOST ELECTRICAL SUPPLIERS) TO PREVENT WATER CORROSION
AND/OR ELECTRICAL SHORT CIRCUIT.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE
FIXTURE, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED.

18
MANUFACTURER
SOFTWARE VERSION
DMX START ADDRESS
DEVICE MODEL DESCRIPTION
DEVICE LABEL
DMX PERSONALITY
DMX PERSONALITY DESCRIPTION
DEVICE HOURS
RESET DEVICE - WARM RESET
RESET DEVICE - COLD RESET
REMOTE DEVICE MANAGEMENT (RDM)
NOTE: In order for RDM to work properly, RDM enabled equipment must be used
throughout the entire system, including DMX data splitters and wireless systems.
Remote Device Management (RDM) is a protocol that sits on top of the DMX512 data
standard for lighting, allowing the DMX systems of the device to be managed, modified,
and monitored remotely (hence, remote device management). This protocol is ideal for
fixtures installed in locations that are not easily accessible.
With RDM, the DMX512 system becomes bi-directional, allowing a compatible RDM
enabled controller to send out a signal to devices on the wire, as well as allowing
the fixture to respond (known as a GET command). The controller can then use it’s
SET command to modify settings that would typically have to be changed or viewed
directly via the unit’s display screen, including the DMX Address, DMX Channel Mode,
and Temperature Sensors.
FIXTURE RDM INFORMATION:
Please be aware that not all RDM devices support all RDM features, and therefore it
is important to check beforehand to ensure that the equipment that you are considering
includes all of the features that you require.
The following parameters are accessible in RDM on this device:
RDM Code Device ID Device Model ID Personality ID
0x1900 33a0326d 0x04A0 0x0103(16CH) 0x0203(88CH)
0x0303(90CH) F: 1(16ch) 2(88ch)
3(90ch)

19
DMX SETUP
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of
communication between intelligent fixtures and controllers. A DMX controller sends DMX data
instructions from the controller to the fixture. DMX data is sent as serial data that travels from
fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most
controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of different manufacturers to be
linked together and operate from a single controller, as long as all fixtures and the controller are
DMX compliant. To ensure proper DMX data transmission, try to use the shortest cable path possible
when using several DMX fixtures. The order in which fixtures are connected in a DMX line does not
influence the DMX addressing. For example, a fixture assigned a DMX address of 1 may be placed
anywhere in a DMX line: at the beginning, at the end, or anywhere in the middle. When a fixture is
assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that
unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): The Hydro Wash X19 can be
data input and data output. We recommend IP65 rated DMX cables to secure the IP65 connections,
such as our Accu Cable STR Series Data Cables. If you are making your own cables, be sure to use
standard 110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores).
cable and an IP65 rated female 5-pin XLR type connector on the other. Also remember that DMX
cable must be daisy chained and cannot be split.
Special Note: Line Termination. When longer runs of cable are used, you may need to use a
terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor
which is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is
inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a
cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
TO MAINTAIN IP65 RATING INTEGRITY AND PREVENT WATER FROM ENTERING THE
FIXTURE, ALL UNUSED CONNECTION RUBBER CAPS MUST BE SEALED, AND ONLY IP65
RATED POWER AND DATA CABLES MUST BE USED.

20
Channel Mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address
16 Channels 1 17 33 49
20 Channels 1 21 41 61
26 Channels 1 27 53 79
30 Channels 1 31 61 91
88 Channels 1 89 177 265
90 Channels 1 91 181 271
DMX ADDRESSING
All fixtures should be given a DMX starting address when using a DMX controller, so the correct
fixture responds to the correct control signal. This digital starting address is the channel number from
which the fixture starts to “listen” to the digital control signal sent out from the DMX controller. The
assignment of this starting DMX address is achieved by setting the correct DMX address on the digital
control display on the fixture.
for each individual fixture. Setting all fixtures to the same DMX address will cause all fixtures to
react in the same way. In other words, changing the settings of one channel will affect all the fixtures
simultaneously.
If you set each fixture to a different DMX address, each unit will start to “listen” to the channel number
you have set, based on the quantity of DMX channels of each fixture. That means changing the
settings of one channel will only affect the selected fixture.
For example, when operatin this device in 16 Channel Mode, you should set the starting DMX address
of the first unit to 1, the second unit to 17 (1 + 16), the third unit to 33 (1 + 16 + 16), and so on.
Other manuals for HYDRO WASH X19
1
Table of contents
Other ADJ Lighting Equipment manuals

ADJ
ADJ ECO UV BAR PLUS IR User manual

ADJ
ADJ FOCUS FLEX User manual

ADJ
ADJ 3 SIXTY 2R User manual

ADJ
ADJ FLAT PAR TW12 User manual

ADJ
ADJ VIZI HEX WASH7 User manual

ADJ
ADJ Warlock User manual

ADJ
ADJ 18P HEX IP User manual

ADJ
ADJ FOCUS FLEX L19 User manual

ADJ
ADJ ENCORE BURST User manual

ADJ
ADJ COB CANNON WASH User manual

ADJ
ADJ Jelly Globe User manual

ADJ
ADJ Encore Profile 1000 WW User manual

ADJ
ADJ Flash Kling Panel 64 User manual

ADJ
ADJ ENCORE LP18IP User manual

ADJ
ADJ HYDRO SPOT I User manual

ADJ
ADJ 12P HEX IP User manual

ADJ
ADJ IKON IR User manual

ADJ
ADJ FLAT PAR TW12 User manual

ADJ
ADJ Encore Profile Mini WW User manual

ADJ
ADJ Vizi Spot LED PRO User manual