ADS-tec VMT6000 series User manual

User Manual
Terminals
VMT6008
Version 2.0

VMT6008 1
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
Index
1Remarks 3
1.1 Relevant Documentation for this device 3
1.2 Used Symbol Explanation 3
1.3 Data, Figures, Modifications 3
1.4 Trademarks 3
1.5 Copyright 4
1.6 Environmental Conditions 4
1.7 Standards 5
1.8 Equipment Versions 5
1.9 Scope of Delivery 6
2Notes on Operation & Safety 7
2.1 Operation Location 7
2.2 Damage Caused By Improper Use 8
2.3 Warranty / Repair 8
2.4 Treatment and Disposal of Lithium Batteries 8
2.5 Notes on Safety 8
3Mounting 9
3.1 External Device Dimensions VMT6008 9
4Commissioning 10
4.1 Available Interfaces 10
4.2 Order of Steps during Commissioning 11
4.3 Check for operational Readiness 12
5Operation 13
5.1 Frontkeys Control Keys 13
5.2 Softkeyboard 15
5.3 TouchScreen 16
5.4 Status Indicators 17
5.5 RFID-Reader (optional) 18
5.6 RFID-Configuration 19
5.7 COMInput-Configuration 21

VMT6008 2
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
6Interfaces 22
6.1 Interface Setup 22
6.2 24V DC Power Supply 22
6.3 Autostart (S1) 24
6.4 Speakers 25
6.5 USB-Interface 26
6.6 PS/2 Interface 26
6.7 Netzwork Connection (RJ45) 27
6.8 Optional Radio Network Card 28
6.9 Serial COM Interface (RS232) 29
7Drives 30
8Software-/Driver-Installation 31
8.1 Configuration Center 33
8.1.1 Automatic Brightness Adaption 34
8.1.2 COM Input Configuration 35
8.1.3 Ignition 35
8.1.4 USB-Lock Function 36
8.1.5 On/Off Button Configuration 37
8.1.6 Exemplary RFID Application 38
8.1.7 Softkeyboard 38
8.1.8 Screen Mob 39
8.1.9 Softkeyboard 39
9Technical Details 40
10 Service & Support 41
10.1 ads-tec Support 41
10.2 Company adress 41
11 Declaration of CE-Conformity 42

VMT6008 3
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
1 Remarks
1.1 Relevant Documentation for this device
The following documents are essential for setting up and operating this device:
User Manual (This Documentation):
Contains information for installation, commissioning and operating the device along with technical data
of the device hardware.
Qucik Start Guide:
Quick Install Guide for fast commissioning.
1.2 Used Symbol Explanation
Warning:
The "Warning" symbol refers to activities which might cause personal injury
or damage to the hardware or software!
Note:
The "Note" symbol familiarises you with conditions to be observed in order to
ensure flawless operation. Additionally, hints and advice are given for a more
efficient use of the device and for software optimisation.
1.3 Data, Figures, Modifications
All texts, data and figures are non-binding. We reserve the right of modification in accordance with
technological progress. At that point in time when the products leave our premises, they comply with all
currently applicable legal requirements and regulations. The operator/operating company is
independently responsible for compliance with and observance of any subsequently introduced
technical innovations and new legal requirements, as well as for all usual obligations of the
operator/operating company
1.4 Trademarks
It is hereby notified that any software and/or hardware trademarks further to any company brand names
as mentioned in this User’s Guide are all strictly subject to the various trademark, brand name and
patent protection rights.
Windows®, Windows® CE are registered trademarks of Microsoft Corp.
Intel®, Pentium®, Atom™ , Core™2 are registered trademarks of Intel Corp.
IBM®, PS/2® and VGA® are registered trademarks of IBM Corp.
CompactFlash™ and CF™ are registered trademarks of SanDisk Corp.
RITTAL® is a registered trademark of the Rittal Werk Rudolf Loh GmbH & Co. KG.
Any further additional trademarks and/or brand names herein, be they domestic or international, are
hereby duly acknowledged.

VMT6008 4
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
1.5 Copyright
This manual, including all contained figures, is protected by copyright law. Any use for third parties non-
compliant with the copyright provisions is prohibited. Any reproduction, translation as well as electronic
and photographic archiving and modification shall only be permitted after explicit written authorisation by
ads-tec GmbH.
Any party in violation of this provision shall be obliged to damage compensation.
1.6 Environmental Conditions
The device may be operated under the following conditions. Failure to observe these specifications will
terminate any warranty for this device. Ads-tec cannot be held liable for any damages arising due to
improper use and handling.
Temperature for devices without a heater
in operation -20 ... 55°C
for storage -30 ... 60°C
Temperature for devices including a heater
in operation -30 ... 55°C
for storage -30 ... 60°C
Humidity:
In operation 10 … 85% without condensate
For storage 10 … 85% without condensate
Vibration resistance
Standard EN 60068-2-6 / 1 G, 10 … 150 Hz
Additionally applies MIL-STD 810F (01.2000), annex C., figure 514.5C
(US highway truck transportation)
Shock resistance
Standard EN 60068-2-27 / 5 G, with a half-wave of 11 ms duration

VMT6008 5
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
1.7 Standards
This device complies with the requirements and protective aims of the following EC regulations:
Standards
This device meets the test requirements for granting the CE sign according to
the European test standards EN 61000-6-4 and EN 61000-6-2
This device complies with the test requirements in accordance with EN 60950
(VDE0805, IEC950) "Safety of Information Technology Equipment"
The device meets the EN 60068-2-6 test requirements (sinus excitation).
This device meets the EN 60068-2-27 test requirements (shock resistance
test)
Note:
A respective conformity declaration for the authority in charge is available at the
manufacturer and may be viewed on request.
All connected components, as well as cable connections must also meet
these requirements for compliance with the EMC legislation. For this reason,
screened bus and LAN cables including screened connectors must be used
and installed according to the instructions in this user manual.
Note:
By using the CE conformity declaration in this document, you can find
detailed information about the standards applicable to this device.
Warning:
This is equipment of class A. This unit might cause radio interferences in
living areas; in this case the operator might be obliged to take suitable
protective measures at the operator’s expense
1.8 Equipment Versions
The system is available in two equipment versions:
Platform including a Flash SSD:
Platform without any rotating mass storage medium (hard disc, etc.) and with an embedded operating
system (Windows CE 6.0 / XP embedded) for stationary use with a standard Ethernet or with radio
networking cards installed on moving commissioning / forklift equipment.
Platform including a hard disc:
Equipped with a hard disc for stationary use, e.g. in the manufacturing department using a standard
operating system.

VMT6008 6
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
1.9 Scope of Delivery
Please check that all of the following components are contained in the packaging:
Scope of Delivery VMT6000 series
1 x device
4-pin Lead-through connector from Phoenix Contact, COMBICON MC 1,5/4-
STF3.81
Service CD
Protective covers
Optional scope of delivery:
Operating system
Installation kit

VMT6008 7
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
2 Notes on Operation & Safety
This device contains electrical voltages and extremely sensitive components. Intervention by the user is
only designated for establishing the required cable connections. The manufacturer or a service partner
authorised by the manufacturer should be consulted if you plan to make further modifications. Before
beginning any works on this device, it must be disconnected from the power supply. Suitable measures
for avoiding any electrostatic discharges towards components must be taken. If the device is opened by
an unauthorised person, hazards for the user might arise and any warranty claim will cease.
General Instructions
All users must read this manual and have access to it at all times
Installation, commissioning and operation may only be carried out by trained
and qualified staff
The security instructions and the manual itself must be observed by all
persons who work with this device
At the location of use, the valid guidelines and regulations for accident
prevention must be observed
The manual contains the most important instructions on how to use this device
in a safe way
Appropriate storage, proper transport, installation and commissioning, as well
as careful operation are prerequisites for ensuring safe and proper operation
of this device
The device can be cleaned by using a soft cloth and a commercially available
glass cleaning agent (e.g. Sidolin) with low alcohol content.
Warning:
Any installation works on the device are only permitted if the power supply is
switched off, and handling the device is safe.
2.1 Operation Location
The VMT control system is designed for use on support arm systems or on moving transport equipment
(like commissioning trolleys, forklifts or similar). You have to take care that the environmental conditions
specified in the technical data specification are met. Using the device in non-specified environments, for
example on board ships, or in areas that might contain explosive gases or in extreme heights is
prohibited.
Warning:
For the prevention of water condensate accumulation, the unit should be turned
ON only when it reaches ambient temperature. This particularly applies when the
unit is subject to extreme temperature fluctuations and/or variations.
Avoid overheating during unit operations; the unit must not be exposed to direct
sunlight or any other direct light or heat sources.

VMT6008 8
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
2.2 Damage Caused By Improper Use
This device must immediately be shut down and protected from any accidental commissioning if the
operating system shows any obvious damage caused by, for example, improper operating or storage
conditions, or by improper use or handling.
2.3 Warranty / Repair
During the warranty period, any repair must only be carried out by the manufacturer or by a person
authorised by the manufacturer.
2.4 Treatment and Disposal of Lithium Batteries
This device contains a lithium battery for supplying the system clock with power as long as the supply
voltage is not connected. The battery has a life cycle of 3 - 5 years depending on which load is applied.
Note:
The more the battery is exposed to higher temperatures, the faster it ages.
Warning:
There is an acute risk of explosion should the wrong type of battery be used.
Warning:
Do not put lithium batteries into a fire, do not solder on the cell body, do not
recharge them, open them, short-circuit them, do not reverse their polarity or heat
them up over 100°C; dispose of them properly and protect lithium batteries from
direct sun light, humidity and condensation.
Lithium batteries may only be replaced by the same type, or by a type recommended by the
manufacturer.
The lithium battery must be disposed of according to the local legislation at the end of its life cycle.
2.5 Notes on Safety
Warning:
Installation works at the device are only permitted if the device is disconnected
from the power supply and protected from accidental switch-on.
Note:
Always adhere to the safety measures applicable when handling components at
risk of being destructed by electrostatic discharges..
(DIN EN 61340-5-1 / DIN EN 61340-5-2)

VMT6008 9
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
3 Mounting
3.1 External Device Dimensions VMT6008
Abb.
1
:

VMT6008 10
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
4 Commissioning
The power supply connection and interfaces of this device are installed underneath a protective cover.
This cover has to be removed in order to connect the power supply lead and the interface cables.
All supply leads and all required data leads have to be connected before commissioning. All supply
leads and all required data leads have to be connected before commissioning.
Warning:
The device must be switched off before connecting or disconnecting any cables in
order to prevent damage to the electronics!
The device may only be switched on after acclimatising to the ambient temperature
in order to avoid condensate accumulation. Make sure to meet the permissible
voltage requirements for this device.
After switching off and before switching on you must wait for at least 5 seconds.
Note:
The screen of a data cable must always be connected with the connector housing
(EMC).
Under the embedded operating system, interfaces must explicitly be enabled
and required drivers must be installed in order to be able to use them.
4.1 Available Interfaces
Abb.
2
:

VMT6008 11
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
Note:
If the case is connected with earth potential at the provided PE contact (e.g. by
connecting the PE contact with the device plug), the electrical insulation is no
longer given. This also applies if the device is installed by using a metal retainer
clip.
If you want to have the device electrically insulated from the power supply,
you have to use a method of installation that ensures appropriate insulation.
Pos: 18 /Datentech nik/Inbetriebnahm e/Reihenfolge der Inbetri ebnahme/Rei henfolge der Inbetriebnah mef ürVMT 60xx- Serie @ 1\mod_1222 073159179_6.d oc @ 4100 @
4.2 Order of Steps during Commissioning
Removing the Lid from the Service Slot
Loosen the undetachable screws on the service slot cover by using a Torx Tx10 wrench and
subsequently remove the service slot cover from the device.
Abb.
3
:
Connecting The Cables
Please connect all required cables. Use grommets in this case, in order to install the cables correctly
and to avoid any potential damage to the cables.

VMT6008 12
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
Note:
A cable installation kit, which includes grommets for several cable diameters,
is available as an option.
Abb.
4
:
Warning:
The indicated protection class is only fully guaranteed if the case cover is correctly
installed!
Pos: 19 /Datentechni k/Inbetriebnahme/Betri ebsbereitschaft prüfe n/Betriebsbereitschaf t prüfenf ürO PC/CPC/PLC/OTC /ITC/VMT-Serie(+M onitore) / IPC 5100/550 0/2400/1100 @ 0\mod_1 158905578361_6.doc @ 38 1@
4.3 Check for operational Readiness
Check the device for any hidden damage potentially caused by improper transport, operating or storage
conditions or by improper use or handling (e.g. smoke development from the device, etc.). If any
damage is detected, the device must be put out of service immediately and protected from accidental
switch-on.

VMT6008 13
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
5 Operation
5.1 Frontkeys Control Keys
Abb.
5
:
Version 1 (State until Q1/2010)
ON / OFF pushbutton of the device (ATX functionality) The
operating system is shut down, but the device is not disconnected
from the input voltage.
Depending on the actual equipment version, each device is equipped with an operating
system (Windows CE 6.0, Windows XP embedded or Windows XP Professional) ex works,
and a soft keyboard is installed. The keys on the front panel are pre-allocated with the
following functions by a specific driver in the soft keyboard:
Level 1:
Activate and deactivate the soft keyboard for letter/character input
by using the touch screen.
Level 2:
Increase the volume of the internal speakers
Level 1:
Change task (Alt+ESC) in Windows.
Level 2:
Decrease the volume of the internal speakers.
Level 1:
Not allocated. The configuration of this level can be customised by
programming via the soft keyboard programme
Level 2:
Increase display brightness.
Level 1:
Right mouse-key function.
Level 2:
Decrease display brightness.
Shift key (SHIFT) for activating the second keyboard level. This
key must be pressed simultaneously with the desired function key.

VMT6008 14
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
Note:
If the software keyboard is not installed, only the functions for display
settings and volume control are active. When changing the values, no
representation is visible on the screen. The key functions can have been
previously modified in accordance with customer specific requirements. The
above described functions are pre-set ex works.
Version 2 (State from Q2/2010)
ON / OFF pushbutton of the device (ATX functionality)
The operating system is shut down, but the device is not
disconnected from the input voltage.
Depending on the actual equipment version, each device is equipped with an operating
system (Windows CE 6.0, Windows XP embedded or Windows XP Professional) ex
works, and a soft keyboard is installed. The keys on the front panel are pre-allocated
with the following functions by a specific driver in the soft keyboard:
Level 1:
Activate and deactivate the soft keyboard for letter/character input
by using the touch screen.
Level 2:
Decrease display brightness.
Level 1:
Change task (Alt+ESC) in Windows.
Level 2:
Increase display brightness.
Level 1:
Not allocated. The configuration of this level can be customised by
programming via the soft keyboard programme
Level 2:
Decrease the volume of the internal speakers.
Level 1:
Right mouse-key function.
Level 2:
Increase the volume of the internal speakers
Shift key (SHIFT) for activating the second keyboard level. This
key must be pressed simultaneously with the desired function
key..

VMT6008 15
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
Note:
If the software keyboard is not installed, only the functions for display
settings and volume control are active. When changing the values, no
representation is visible on the screen. The key functions can have been
previously modified in accordance with customer specific requirements. The
above described functions are pre-set ex works.
Pos: 21 /Datent echni k/Bedienung/Soft keyboard/Softke yboard für VM T 60xx @ 1\mod_122 8750145198_ 6.doc @ 42 51 @
5.2 Softkeyboard
If an operating system is installed ex works, the soft keyboard is also preinstalled. If the operating
system is delivered separately with the device, the soft keyboard must also be installed on site. By using
the soft keyboard, data can be entered via the touch screen like with an external keyboard.
Abb.
6
:

VMT6008 16
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
How to operate the Soft Keyboard from Version 3.11::
Activate and deactivate the soft keyboard for letter/character input
using the touch screen
Switches numeric keys on and off (only if numeric keys are visible)
Switching between different representations (Alphanumeric keys
Numeric keys Function key bar)
Soft keyboard representation, zoom in
Soft keyboard representation, zoom out
Note:
If a function is to be activated which requires pressing two keys at the same
time (e.g. Alt + F4), these keys have to be pushed one after another at the
soft keyboard, and the special keys Shift, Alt and Ctrl must always be
pushed first.
Due to differences in programming of a large variety of software
programmes, we cannot ensure that the soft keyboard works properly with
all available software.
When deactivating the soft keyboard, the previously active state
(alphanumeric / numeric keys or function keys) will be stored and will be
displayed when re-activating the keyboard.
Pos: 22 /Datentech nik/Bedienung/Touch Scr een/Touch Scree n für VMT 60xx @ 1\mod_1 246361069977 _6.doc @ 5853 @
5.3 TouchScreen
The control system is equipped with a touch screen monitor. The touch screen monitor is internally
connected with the USB interface. The driver software required for using the touch screen is integrated
in the corresponding operating system, or can alternatively be installed from the enclosed service CD.
Pos: 23 /Datentech nik/Bedienung/St atus-Anzeigen/SYS- LED/SYS-LED für VMT 60xx-Serie @ 2\ mod_126052554026 9_6.doc @ 6876 @

VMT6008 17
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
5.4 Status Indicators
SYS-LED (Bicoloured)
Depending on the colour and type of flashing, different device states are displayed by the SYS LED.
Abb.
7
:
Folgende Signale werden dargestellt:
System-LED Indicators
Behaviour
Description
static
Device is connected with a power
source and switched on.
flashing
Volume / display brightness is
being modified
static
Minimum / maximum value for
volume / display brightness is
reached.
Lightsensor
static
Brightness adaptation depending
on the received light intensity with
automatic setting
Pos: 24 /Datentech nik/Sondergeräte-M odule/VMT6000-S erie/RFID-Rea der für VMT6000-Seri e @2 \mod_1260527 463758_6.doc @ 688 5@

VMT6008 18
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
5.5 RFID-Reader (optional)
By using the RFID reader, passive RFID TAGS (RFID chip / key card) are available for automatic
system login. The user applies the RFID tag like a key and requires neither user name nor password.
For authentication, the key card or the RFID chip are held in front of the position highlighted in the
figure. The information from your key card or RFID chip is read and evaluated by the device.
The VMT6000 series uses Mifare-, and LEGIC Technology.
Abb.
8
:

VMT6008 19
© ads-tec GmbH • Heinrich-Hertz-Str.1• 72622 Nürtingen
5.6 RFID-Configuration
The equipment is pre-configured to test the RFID functionality without configuration.
Note:
Check the functionality of your RFID reader through the following steps
before starting the commissioning of a software to exclude any transport
damage or other error sources.
Depending on the hardware configuration a MIFARE or LEGIC RFID reader is installed.
MIFARE
1) To test the RFID function, select the application "ads-tec RFID sample application" on the pre-
installed Configuration Center.
Ads-tec RFID-Reader Tool
The configuration of the application starts automatically, by launching the application which searches on
all COM ports to the RFID reader.
Abb.
9
:
If an RFID reader is detected,it is interrogated cyclically whether a serial number (CSN) was read. It
generates a transponder serial number which is output directly to the surface.