UNIONCOMMUNITY AC-6000 User manual

Doc. Ver. : V2.10
Aug.,21.2014
R&D Center
Union Community Co., Ltd.
Installation & Wiring Guide
Fingerprint/Card Terminal
AC-6000 V2.0

Installation for AC-6000 V2.0 2
1. Power Connector connection
Power Adapter
Interface
GND (BK) - 2
+12V (RE) - 1
P - 3
P - 2
P - 1
** Insert the Power Cable to VIN/PG Terminal Block
in right color matching as the picture

Installation for AC-6000 V2.0 3
2. Connecting Ethernet & Power Cable
Switch Hub or Hub
UTP 10Base-T
RJ45
** UTP Connector
Adapter

Installation for AC-6000 V2.0 4
3. Main Board Feature
J303 Power/Door Lock Control Output
1 [Vin ] : DC Power Input
2 [ PG ] : Ground for DC Power
3 [ DPV ] : Door Phone Voltage IN
4 [ DPS ] : Door Phone Signal
5 [ L1 ] : Lock Output 1
6 [ L1C ] : Lock COM for Output 1
7 [ L2 ] : Lock Output 2
8 [ L2C ] : Lock Com for Output 2
9 [ LG ] : Ground for Lock Control
J304 communication/ Status Input
1 [ IO ]: Inside Open
2 [M0 ]: Door Monitor 0
3 [M1 ]: Door Monitor 1
4 [M2 ]: Door Monitor 2
5 [ G ] : Ground [ Door Status ]
6 [R2T]: RS232 TXD Output
7 [R2R]: RS232 RXD Input
8 [ G ] : Ground for RS232
9 [R4A]: RS485 A
10 [R4B]: RS485 B
11[WI0]: Wiegand Input 0
12[WI1]: Wiegand Input 1
13[WO0]: Wiegand Output 0
14[WO1]: Wiegand Output 1
15[ G ] : Ground [ Wiegand interface ]
16[ 5V ] : 5V Output
Switch Setting I[ Lock Type Selection ]
SW301 : ST/M [ Strike/Motor/Dead-bolt Lock ]
A/D [ Auto Door / Lock1 No Power Contact ]
SW302 : NO/MT [ Normal Open Relay Contact ]
NC [ Normal Close Relay Contact ]
SW303 : ST/AT.DR [ Strike, Auto Door, Dead bolt ]
MT [ Motor Lock Selection ]
SW304, SW305 : Normal [ 2nd Lock, Emergency Lamp]
nPwr[ Lock2 No Power contact ]
Switch Setting II [ RS485 T_Resistor Selection ]
SW251 : ON [ 120ohm termination resistor ]
OFF [ Open the termination resistor ]
Switch Setting III [ RS485RS232 Selection ]
SW255 : RS232 [ J304 Pin 6&7 Enabled ]
RS485 [ J306 Pin 9&10 Enabled ]
Switch Setting IV [ DebugIrDA Selection ]
SW254 : Debug [ for Developer ]
IrDA [ for IrDA ]
J304 Communication/ Status Input Interface
J303 Power/ Lock/ Door-phone Interface
SW301~305
Lock Type Switch
SW251 RS485 Termination
Resistor Select Switch
SW254 Debug/IrDA
Select Switch
SW255 RS485RS232
Select Switch
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
J252 RF/SC Card
J203 USB1.1 Host
J202 USB1.1 Host
J201 USB2.0 Client
J152 RJ45 Jack for Ethernet
SW1 Reset Switch
1
2
3
4
5
6
7
8
9
F351 Fuse

Installation for AC-6000 V2.0 5
4. Keypad Board Feature
J606 MiC
J671 LCD/AC97
FPC 40pin
J603 Camera
Opposite Side
J602 FP/Camera/Button
FPC 50pin
J673 Speaker
J604 FP Sensor
J672 LCD
FPC 45pin
RV601 Door Phone
Volume
J674 Touch Screen

Installation for AC-6000 V2.0 6
5. Schematic for Door Lock Interface
FB301
HH1M2012-601JT
1 2
LOCK2
C303
104C2
1
2
LockCon1
C306
104C2
1
2
NO/MT
473
222 Q301
KRC105S
2
13
DoorLock Interface
NP VIN
NP
SW302
BSI-10
NC
SW304
BSI-10
D302
S1A
AK
SW305
BSI-10
NML
VIN
Lock1_COM
SW303
BSI-10
ST//MT
NML
LOCK2_COM
LockCon2
473
222 Q302
KRC105S
2
13
LOCK1
VCC_5V
SW301
BSI-10
MT
VCC_5V
AT.DR
C305
104C2
1
2
D301
S1A
AK
K301
G6S-2G-5VDC
910
8
43
5
1
12
AT.DR/ST
K302
G6S-2G-5VDC
910
8
43
5
1
12
LOCK2_COM
LOCK2
J303
BI-35-DB250-09
5
6
7
9
1
2
3
4
8
Lock 1
Lock 1 Com
Lock 2
Gnd
DC_IN
DC_Gnd
IP_V(+)
IP_SIG
Lock 2 Com
IP_V10
Lock1_COM
Terminal Block 9PIN
DC_IN9
IP_SIG10 LOCK1

Installation for AC-6000 V2.0 7
6. Connection of Wires to terminal blocks
J304 communication/ Status Input
16[5V] : 5V Output
15[ G ] : Ground [ Wiegand ]
14[WO1]: Wiegand Output 1
13[WO0]: Wiegand Output 0
12[WI1]: Wiegand Input 1
11[WI0]: Wiegand Input 0
10[R4B]: RS485 B
9 [R4A]: RS485 A
8 [ G ]: Ground [ Serial Port ]
7 [R2R]: RS232 RXD Input
6 [R2T]: RS232 TXD Output
5 [ G ] : Ground [ Input ]
4 [M2 ]: Door Monitor 2
3 [M1 ]: Door Monitor 1
2 [M0 ]: Door Monitor 0
1 [ IO ]: Inside Open
J303 Door Lock Control Output
1 [ VIN ] : DC Power Input
2 [ PG ] : Ground for DC Power
3 [ DPV ] : Door Phone Voltage IN
4 [ DPS ] :Door Phone Signal
5 [ L1 ] : Lock Output 1
6 [ L1C ] : Lock COM for Output 1
7 [ L2 ] : Lock Output 2
8 [ L2C ] Lock COM for Output 2
9 [ LG ] : Ground for Lock Control

Installation for AC-6000 V2.0 8
7. Connection of Door Phone
※ The Installation distance is Max 30M(100feet) between AC-6000 and Door Phone.
If you want to call the door phone, please use the “Call”button.
※ The Color is not important….
Door
Phone
pin5 Ground (BK)
pin1 Inside Open (OR)
** Inside Open Switch Connection
pin3 VIN (RE)
pin4 Signal (Blue)

Installation for AC-6000 V2.0 9
8. Connecting Dead-Bolt Type Door Lock (Fail Safe)
8.1. Connect with One System/ One Lock
Black
Red
Gray
Green
Red
Black
Green
Gray
: Lock (+)
: Lock (-)
: Door Monitor (NO)
: Ground (Door Status Com)
Lock(+)
Lock Type Select S/W
Lock(-)
AutoDoor/ST == MT
NC ======== NO/MT
ST/MT == AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
Inside Door
Open S/W
Door Monitor
Inside Open
GND

Installation for AC-6000 V2.0 10
Lock(+)
Lock Type Select S/W
Lock(-)
AutoDoor/ST == MT
NC ======== NO/MT
ST/MT == AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
8. Connecting Dead-Bolt Type Door Lock (Fail Safe)
8.2. Connect with Two Systems/ One Lock
System 1
Lock(+)
Lock Type Select S/W
Lock(-)
AutoDoor/ST == MT
NC ======== NO/MT
ST/MT ==AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
System 2 Black
Red
Gray
Green
Red
Black
Green
Gray
: Lock (+)
: Lock (-)
: Door Monitor (NO)
: Ground (Door Status Com)
Door Monitor

Installation for AC-6000 V2.0 11
9. Connecting Strike Type Door Lock (Fail Safe)
9.1. Connect with One system/ One Lock
Lock(+)
Lock Type Select S/W
Lock(-)
AutoDoor/ST == MT
NC ======== NO/MT
ST/MT == AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
Inside Door
Open S/W
Door Monitor
Inside Open
GND
(-)Black
(+)Red

Installation for AC-6000 V2.0 12
9. Connecting Strike Type Door Lock (Fail Safe)
9.2. Connect with Two systems/ One Lock
Lock(+)
Lock Type Select S/W
Lock(-)
AutoDoor/ST == MT
NC ======== NO/MT
ST/MT == AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
System 1
Lock(+)
Lock Type Select S/W
AutoDoor/ST == MT
NC ======== NO/MT
ST/MT ==AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
System 2
Door Monitor
(-)Black
(+)Red

Installation for AC-6000 V2.0 13
10. Connecting Strike Type Door Lock (Fail Secure)
10.1. Connect with One system/ One Lock
Lock(+)
Lock Type Select S/W
Lock(-)
AutoDoor/ST == MT
NC ========NO/MT
ST/MT == AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
Inside Door
Open S/W
Door Monitor
Inside Open
GND
(-)Black
(+)Red

Installation for AC-6000 V2.0 14
10. Connecting Strike Type Door Lock (Fail Secure)
10.2. Connect with Two systems/ One Lock
Lock(+)
Lock Type Select S/W
Lock(-)
AutoDoor/ST == MT
NC ========NO/MT
ST/MT == AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
System 1
Lock(+)
Lock Type Select S/W
Lock(-)
AutoDoor/ST == MT
NC ========NO/MT
ST/MT ===AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
System 2
Door Monitor
(-)Black
(+)Red

Installation for AC-6000 V2.0 15
11. Connecting EM Type Door Lock (Fail Safe)
11.1. Connect with One system/ One Lock
Lock(+)
Lock Type Select S/W
Lock(-)
AutoDoor/ST == MT
NC ======== NO/MT
ST/MT == AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
Inside Door
Open S/W
Door Monitor
Inside Open
GND
(-)Black
(+)Red

Installation for AC-6000 V2.0 16
11. Connecting EM Type Door Lock (Fail Safe)
11.2. Connect with Two System/ One Lock
Lock(+)
Lock Type Select S/W
Lock(-)
AutoDoor/ST == MT
NC ======== NO/MT
ST/MT == AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
System 1
Lock(+)
Lock Type Select S/W
AutoDoor/ST == MT
NC ======== NO/MT
ST/MT ==AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
System 2
Door Monitor
(-)Black
(+)Red

Installation for AC-6000 V2.0 17
11. Connecting EM Type Door Lock (Fail Safe)
11.3. Connect with One system/ Two Locks ** Use external DC Power adapter
Lock(+)
Lock Type Select S/W
AutoDoor/ST == MT
NC ======== NO/MT
ST/MT ==AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
Inside Door
Open S/W
Door Monitor
Inside Open
GND
Lock(-) (-)Black
(+)Red
Door Monitor
12V 3A
Adapter
(+) (-)
External
Lock 1
Lock 2

Installation for AC-6000 V2.0 18
12. Connecting Auto-Door (Contact Control)
12.1. Connect with One system/ One Door
Lock(+)
Lock Type Select S/W
AutoDoor/ST == MT
NC ========NO/MT
ST/MT ==AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
Inside Door
Open S/W
Sensor Input Line
9P CONN
Auto-Door Sensor Auto-Door Monitor
Auto Door Operating Part Auto Door Motor
Lock(-)

Installation for AC-6000 V2.0 19
12. Connecting Auto-Door (Contact Control)
12.2. Connect with Two systems/ One Door
Lock(+)
Lock Type Select S/W
AutoDoor/ST == MT
NC ========NO/MT
ST/MT ==AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
Lock(-)
System 1
Lock(+)
Lock Type Select S/W
AutoDoor/ST == MT
NC ========NO/MT
ST/MT ==AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
Lock(-)
System 2
Sensor Input Line
9P CONN
Auto-Door Sensor Auto-Door Monitor
Auto Door Operating Part Auto Door Motor

Installation for AC-6000 V2.0 20
13. Connecting Mortise Lock
13.1. Connect with Motor Lock
Motor 1
Lock Type Select S/W
Motor 2
AutoDoor/ST ==MT
NC ========NO/MT
ST/MT == AutoDoor
Normal ===== nPwr
Normal ===== nPwr
SW251
SW303
SW302
SW301
SW304
SW305
5V
G
wo1
wo0
wi1
wi0
R4B
R4A
G
R2R
R2T
G
M2
M1
M0
IO
VIN
PG
DPV
DPS
L1
L1C
L2
L2C
LG
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
9
Inside Door
Open S/W
Inside Open
** Select motor lock 1st in the Lock setting
at the configuration menu.
Blue
Brown
Orange
White
Yellow
Black
Red
: Motor 2
: Motor 1
: Door Monitor
: Ground
: Unlock Signal
: Ground
: Lock Signal
** Example : AL3M Series.
Other UNIONCOMMUNITY Touch Terminal manuals

UNIONCOMMUNITY
UNIONCOMMUNITY AC-5000 User manual

UNIONCOMMUNITY
UNIONCOMMUNITY UBio-X Face Premium User manual

UNIONCOMMUNITY
UNIONCOMMUNITY VS-R20DSC User manual

UNIONCOMMUNITY
UNIONCOMMUNITY UBio-X Face Premium User manual

UNIONCOMMUNITY
UNIONCOMMUNITY MiKey AC1100 User manual

UNIONCOMMUNITY
UNIONCOMMUNITY AC-5000RF User manual
Popular Touch Terminal manuals by other brands

Huawei
Huawei OptiXstar K153-10 quick start

Omron
Omron Programmable Terminals NT631 Operation manuals

Allen-Bradley
Allen-Bradley PanelView Plus 400 installation instructions

CreativeStar
CreativeStar JXG-213-F instruction manual

Ysoft
Ysoft YSoft SafeQ Administrator's guide

Prestel
Prestel VCS-G2PRO user guide