DESCRIPTION
The Small Form-Factor Pluggable Gigabit Ethernet,
Single-Mode (SFPGS) plugs into ADTRAN GigE host
modules designed to accept SFPs. The SFPGS provides
an optical interface to the GigE physical interface.
Installed into an appropriate host module, the SFPGS
provides a Gigabit Ethernet tributary interface to the
supporting system.
NOTE: To ensure compatibility, refer to the documentation
provided with the host module.
The following features are supported on the SFPGS:
♦1000Base-LX 1310 nm, single-mode, 2 fiber
operation
♦Optical distance: 10 km maximum
CAUTION: Due to compliance certification requirements,
only SFPs supplied by ADTRAN are to be used
with the host module. ADTRAN cannot certify
system integrity with other SFPs.
Operational Specifications
♦Optical Specifications:
– Optical transmit level: –3 dBm to –11 dBm
– Optical receive level: –3 dBm to –19 dBm
– Link power budget: 8 dB
– Optical connectors: LC
♦Extended Environmental Support:
– Operational temperature range: –40°C to +85°C
– Storage temperature range: –40°C to +100°C
– Relative humidity to 95%, noncondensing
Small Form-Factor Pluggable
Gigabit Ethernet, Single-Mode
INSTALLATION
To install the SFPGS into an appropriate module,
complete the following steps:
1. Inspect the SFPGS. If damaged, file a claim with the
carrier and then contact ADTRAN Customer Service.
2. Remove the safety cap from the optical connectors of
the SFPGS.
3. Insert the SFPGS into the receptacle on the circuit
board of the host module, with the manufacturer’s
label facing outward. Slide the SFPGS all the way
into the receptacle.
4. Use thumb and forefinger to squeeze the receptacle
and SFPGS together, to ensure a proper connection.
NOTE: The latch on the SFP is for removal only.
5. Continue the installation and turn-up of the host
module using the instructions in the Job Aid
provided with that module, or using the Installation
and Maintenance Practice (I&M), available online at
www.adtran.com.
PROVISIONING
The SFPGS is not directly provisionable. To provision the
SFPGS, access the menu system of the host module.
Refer to the “Provisioning” section of the Job Aid or I&M
provided with the host module for provisioning details.
CLEI: SOOTAD9J_ _
Product P/N: 1184561PG1 Issue Date: 0804
Document P/N: 61184561PG1-22A
NOTE: The Gigabit Ethernet port is optical and therefore
are not classified as any type of port as defined in
Appendix B of GR-1089-CORE Issue 4.
The SFPGS is designed to meet the following environ-
mental classes:
♦ETSI EN 300 019-1-1 “Classification of
environmental conditions; Storage,” Class 1.2
♦ETSI EN 300 019-1-2 “Classification of
environmental conditions, Transportation,” Class 2.3
♦ETSI EN 300 019-1-3 “Classification of
environmental conditions, Stationary use at weather-
protected locations,” Class 3.3
The equipment is designed to function without degra-
dation during exposure to all test severities per Class 3.3.
The Small Form-Factor Pluggable Gigabit Ethernet
Single-Mode meets the EU’s RoHS Directive 2002/95/EC
and/or applicable exemptions. See www.adtran.com for
further information on RoHS/WEEE.
COMPLIANCE
CAUTION: Electrostatic Discharge (ESD) can damage
electronic modules. When handling modules,
wear an antistatic discharge wrist strap to
prevent damage to electronic components. Place
modules in antistatic packing material when
transporting or storing. When working on
modules, always place them on an approved
antistatic mat that is electrically grounded.
The SFPGS is NRTL Listed to the applicable UL
standards. The SFPGS meets or exceeds all the
applicable requirements of NEBS, Telcordia
GR-63-CORE, and GR-1089-CORE. The SFPGS
is intended for deployment in Central Office type
facilities, EEEs, EECs, and locations where the
NEC applies (for example, Customer Premises).
Install the SFPGS in an ADTRAN product located
in a restricted access location.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received,
including interference that may cause undesired
operation.
Changes or modifications not expressly approved by
ADTRAN could void the user's authority to operate this
equipment.
CAUTION: Per GR-1089-CORE the ADTRAN system that
the SFP is being deployed in is designed and
intended for installation as part of a Common
Bonding Network (CBN). The ADTRAN system
that the SFP is being deployed in is not designed
nor intended for installation as part of an
Isolated Bonding Network (IBN).
Per GR-1089-CORE Section 9, the SFPGS does
not have an internal DC connection between
battery return and frame ground. The SFPGS
can be installed in a DC-I (isolated) or DC-C
(common) installation. For installations where
other cards or the host system have internal
connections between battery return and frame
ground, the system would be intended for
deployment only in a DC-C installation.
The ADTRAN system chassis frame ground
terminal must be connected to an earth ground to
ensure that the metal enclosure of the SFPGS is
properly grounded via the backplane connector.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet
its published specifications or fails while in service. Warranty information can be found
online at www.adtran.com/warranty.
© 2008 ADTRAN, Inc. All Rights Reserved. *61184561PG1-22A*
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
CLEI: SOOTAD9J_ _
Product P/N: 1184561PG1 Issue Date: 0804
Document P/N: 61184561PG1-22A
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
Small Form-Factor Pluggable
Gigabit Ethernet, Single-Mode

Other ADTRAN Switch manuals

ADTRAN NetVanta 1560-08-150W User manual

ADTRAN

ADTRAN NetVanta 1560-08-150W User manual

ADTRAN Total Access 1210 Installation guide

ADTRAN

ADTRAN Total Access 1210 Installation guide

ADTRAN DDM+ H2TU-C User manual

ADTRAN

ADTRAN DDM+ H2TU-C User manual

ADTRAN NetVanta Series User manual

ADTRAN

ADTRAN NetVanta Series User manual

ADTRAN NetVanta 1748F Series User manual

ADTRAN

ADTRAN NetVanta 1748F Series User manual

ADTRAN DSU III S2W User manual

ADTRAN

ADTRAN DSU III S2W User manual

ADTRAN NetVanta 1544 Series User manual

ADTRAN

ADTRAN NetVanta 1544 Series User manual

ADTRAN NetVanta 7000 Series User manual

ADTRAN

ADTRAN NetVanta 7000 Series User manual

ADTRAN NetVanta 1234P Manual

ADTRAN

ADTRAN NetVanta 1234P Manual

ADTRAN NetVanta 1560-08-65W User manual

ADTRAN

ADTRAN NetVanta 1560-08-65W User manual

ADTRAN NetVanta 1560-48 User manual

ADTRAN

ADTRAN NetVanta 1560-48 User manual

ADTRAN TRACER 1280050L1 User manual

ADTRAN

ADTRAN TRACER 1280050L1 User manual

ADTRAN NetVanta 1531P User manual

ADTRAN

ADTRAN NetVanta 1531P User manual

ADTRAN T1 CSU ACE User manual

ADTRAN

ADTRAN T1 CSU ACE User manual

ADTRAN NetVanta 1224STR PWR User manual

ADTRAN

ADTRAN NetVanta 1224STR PWR User manual

ADTRAN 3192 H2TU-C User manual

ADTRAN

ADTRAN 3192 H2TU-C User manual

ADTRAN NetVanta 1560-48-370W User manual

ADTRAN

ADTRAN NetVanta 1560-48-370W User manual

ADTRAN NetVanta 1224 PoE User manual

ADTRAN

ADTRAN NetVanta 1224 PoE User manual

ADTRAN SDX 8110-24-740W User manual

ADTRAN

ADTRAN SDX 8110-24-740W User manual

ADTRAN netvanta 1230 series User manual

ADTRAN

ADTRAN netvanta 1230 series User manual

ADTRAN NetVanta 1235P User manual

ADTRAN

ADTRAN NetVanta 1235P User manual

ADTRAN NetVanta 1524ST User manual

ADTRAN

ADTRAN NetVanta 1524ST User manual

ADTRAN NetVanta 1560-24-740W User manual

ADTRAN

ADTRAN NetVanta 1560-24-740W User manual

ADTRAN 1702594G1 NetVanta 1234 Manual

ADTRAN

ADTRAN 1702594G1 NetVanta 1234 Manual

Popular Switch manuals by other brands

Tycon Power Systems TP-MS4x4 user manual

Tycon Power Systems

Tycon Power Systems TP-MS4x4 user manual

LEGRAND Wattstopper InteliSwitch TS-400 installation instructions

LEGRAND

LEGRAND Wattstopper InteliSwitch TS-400 installation instructions

Renkforce 1289403 operating instructions

Renkforce

Renkforce 1289403 operating instructions

Fairchild NC7SB3257 TinyLogic General description

Fairchild

Fairchild NC7SB3257 TinyLogic General description

TP-Link TL-SG105 installation guide

TP-Link

TP-Link TL-SG105 installation guide

Channel Vision P-1205 user guide

Channel Vision

Channel Vision P-1205 user guide

ROLF HEUN 720.0030 instruction manual

ROLF HEUN

ROLF HEUN 720.0030 instruction manual

EINHELL 41.742.21 Original operating instructions

EINHELL

EINHELL 41.742.21 Original operating instructions

Luxul XMS-1024P Quick install guide

Luxul

Luxul XMS-1024P Quick install guide

socomec ATyS Series instruction manual

socomec

socomec ATyS Series instruction manual

Linkskey LKS-SG5P user guide

Linkskey

Linkskey LKS-SG5P user guide

Flaming River BIG SWITCH 500 manual

Flaming River

Flaming River BIG SWITCH 500 manual

Linkskey LKS-SG16R user manual

Linkskey

Linkskey LKS-SG16R user manual

eicos FH12B02-M12 manual

eicos

eicos FH12B02-M12 manual

Edimax GS-1026 manual

Edimax

Edimax GS-1026 manual

AETEK D51-084-30 Quick installation guide

AETEK

AETEK D51-084-30 Quick installation guide

Cisco Nexus 4005I Getting started guide

Cisco

Cisco Nexus 4005I Getting started guide

Planet Networking & Communication ISW-504PT user manual

Planet Networking & Communication

Planet Networking & Communication ISW-504PT user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.