ADTRAN /FXS/FXO 850 Quad User manual

C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
JOBAID
QUAD FXO
L1 CLEI: SIC2VXOK_ _
L2 CLEI: SIC2VXHK_ _
QUAD FXS
L1 CLEI: SIC2WXOK_ _
L2 CLEI: SIC2WXHK_ _
TOTAL ACCESS 750 QUAD FXS/FXO
TURN UP STEPS
Insert card into slots 1-6 on the TA 750. The unit will automatically map
DS0s in the T1 as noted below.
TIME SLOT ASSIGNMENT
Physical Slot T1 Time Slot Assigned
11-4
25-8
3 9-12
4 13-16
5 17-20
6 21-24
Verify LED sequencing. LEDs will stop sequencing once unit is initialized.
Note: If the unit is inserted into a physical slot which has its timeslots allocated to the FT1
(DSX-1) or Nx56/64 port, the LEDs will sequence continually, indicating a problem.
The time slots must be freed up using the menu interface before the unit will become
operational.
STATUS LEDS (GREEN)
●●OFF On Hook
✸FLASHING Ringing (FXS only)
●ON Off Hook (Busy)
●●SEQUENCING All Four Time Slots Unavailable
●
●●
●●
If factory default settings to be used for the application, then installation
is complete. If further provisioning is desired proceed to step 4.
FACTORY DEFAULT SETTINGS
The FXS unit has factory default provisioning: FXS mode, loop start signaling and
automatic loop provisioning. The automatic loop provisioning function will
automatically set the line impedance and gain after the first off hook event.
The FXO factory default settings are FXO mode and loop start signaling.
If different settings are desired, the VT 100 terminal interface is used.
61175408L2-22B
0006
Connect VT 100 compatible terminal to BCU faceplate ADMIN port
4a Connect DB-9 cable
4b Run terminal emulation program
Craft Port Settings are as follows: 9600 Baud, No parity, 8 data
bits, 1 Stop bit, No flow control.
4c If using Windows Hyperteminal open by selecting
Programs/Accessories/Hyperterminal
Note: To ensure proper display background, select VT 100 Terminal Emulation under Settings.
Proceed through menus to desired access module
5a select Access Modules
5b select 1-6 (slot)
5c select 1-4 (circuit)
Note: To traverse through the menus, select the desired entry and press Enter. To work back-
wards in the menu press ESC (escape key). To return to the top of the menu at any time,
press the return key twice.
Change port provisioning for a particular application.
Note: Provisioning for a port can be copied to another port or to all similar ports.
Testing - to access the test menu for an access module select test (item 4
after 5c)
TESTING
Self Test
■Performed when the Quad FXS or FX0 is inserted into an active chassis
to verify proper operation of critical circuits.
Initiated Tests
■Digital Loopback Test – loops back DS0 data coming from the network
for each individual channel.
■Network On-Hook / Off-Hook Test –tests signaling sent to the network
by the unit.
■Customer Ring Test (FXS only) –activates the unit’s ring relay in a 2-on /
4-off ring cadence, providing ringing to the customer loop.
■1000 Hz DRS Tone Generation Test –sends DRS signal on the receive
path to the loop and transmit path towards Carrier.
Note: All tests except self test are initiated through the TA 750 BCU Admin Port, TA 850
RCU, or TA 1500 SCU.
Note: The Quad FXS is for use in the TA 750 and the TA 850.
The Quad FX0 is for use in the TA 750, the TA 850, and the TA 1500.
Note: The 1175408L2 is completely interchangeable with the 1175408L1.
The 1175407L2 is completely interchangeable with the 1175407L1.
1
3
4
5
6
7
2
■For a complete Quad FXS I&M Practice: 877.457.5007, Document # 484. Please have your fax number available.■
■For a complete Quad FX0 I&M Practice: 877.457.5007, Document # 485. Please have your fax number available.■
CONNECTIONS
■All connections are made through the 50-pin amphenol connector on the back panel
TA 750/850/1500.
ELECTRICAL CODE COMPLIANCE
The Quad FXS and Quad FXO are to be installed in restricted access locations and in equipment
with a Type “B”or “E”installation code.
Code Input Output
IC A –
TC – X
PC C C
APPLICATIONS
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user’s authority to
operate this equipment.
PRICING AND AVAILABILTY 800.827.0807
TECHNICAL SUPPORT 888-4ADTRAN
RETURN FOR REPAIR 256.963.8722
www.adtran.com
TOTAL ACCESS 750 QUAD FXS/FXO
MODES OF OPERATION
Note: Signaling states are provisioned through the BCU.
FXS
■FXS Loop Start (default)
■FXS Ground Start
■TR-08 Single Party
■TR-08 Universal Voice Grade
■DPO
■Tandem (E & M)
FXO
■FXO Loop Start (default)
■FXO Ground Start
■DPT
ATTENUATION LEVELS
0 dB to -9 dB
FXS
■Short loop default: -6 dB Transmit, –3 dB Receive
■Long loop default: -3 dB Transmit, –3 dB Receive
FXO
■Default 0 dB Transmit, 0 dB Receive
IMPEDANCE SETTINGS
FXS
600 Ω
900 Ω
600 Ω+ 2.16 µF (short loop default)
900 Ω+ 2.16 µF (long loop default)
FXO
900 Ω+ 2.16 µF
WARRANTY
Warranty for Carrier Networks products manufactured by ADTRAN and supplied under
Buyer's order for use in the U.S. is ten (10) years. For a complete copy of ADTRAN's U.S.
Carrier Networks Equipment Warranty: (877) 457-5007, Document 414.
Router
Switch GR303 Access
Concentrator
Data Switch
DCS
Switch
Switch
DS1
DS1
TDM
GR303

This manual suits for next models

1

Other ADTRAN Switch manuals

ADTRAN NetVanta 1224STR PWR Manual

ADTRAN

ADTRAN NetVanta 1224STR PWR Manual

ADTRAN NetVanta 7000 Series User manual

ADTRAN

ADTRAN NetVanta 7000 Series User manual

ADTRAN NetVanta 1560-48-740W User manual

ADTRAN

ADTRAN NetVanta 1560-48-740W User manual

ADTRAN NetVanta 1224 User manual

ADTRAN

ADTRAN NetVanta 1224 User manual

ADTRAN T1 CSU ACE User manual

ADTRAN

ADTRAN T1 CSU ACE User manual

ADTRAN NetVanta 1224ST User manual

ADTRAN

ADTRAN NetVanta 1224ST User manual

ADTRAN D4 TRDDB User manual

ADTRAN

ADTRAN D4 TRDDB User manual

ADTRAN NetVanta 1638 Manual

ADTRAN

ADTRAN NetVanta 1638 Manual

ADTRAN NetVanta 1024 User manual

ADTRAN

ADTRAN NetVanta 1024 User manual

ADTRAN 3192 H2TU-C User manual

ADTRAN

ADTRAN 3192 H2TU-C User manual

ADTRAN 1534/1544 User manual

ADTRAN

ADTRAN 1534/1544 User manual

ADTRAN 1703594G1 User manual

ADTRAN

ADTRAN 1703594G1 User manual

ADTRAN NetVanta 1560-24-370W User manual

ADTRAN

ADTRAN NetVanta 1560-24-370W User manual

ADTRAN NetVanta 1748F Series Manual

ADTRAN

ADTRAN NetVanta 1748F Series Manual

ADTRAN DSU III S2W User manual

ADTRAN

ADTRAN DSU III S2W User manual

ADTRAN 7912 Instruction Manual

ADTRAN

ADTRAN 7912 Instruction Manual

ADTRAN NetVanta 1570-24-370W User manual

ADTRAN

ADTRAN NetVanta 1570-24-370W User manual

ADTRAN D4 OCU DP (ETR) D4-OCU Instruction Manual

ADTRAN

ADTRAN D4 OCU DP (ETR) D4-OCU Instruction Manual

ADTRAN TRACER 5045 User manual

ADTRAN

ADTRAN TRACER 5045 User manual

ADTRAN FT1 DP User manual

ADTRAN

ADTRAN FT1 DP User manual

ADTRAN NetVanta 1560-08-150W User manual

ADTRAN

ADTRAN NetVanta 1560-08-150W User manual

ADTRAN netvanta 1230 series User manual

ADTRAN

ADTRAN netvanta 1230 series User manual

ADTRAN NetVanta 1335 Series User manual

ADTRAN

ADTRAN NetVanta 1335 Series User manual

ADTRAN TRACER 1280050L1 User manual

ADTRAN

ADTRAN TRACER 1280050L1 User manual

Popular Switch manuals by other brands

Nortel 425-24T manual

Nortel

Nortel 425-24T manual

Acnodes IP-16 Specifications

Acnodes

Acnodes IP-16 Specifications

Yeastar Technology UF51 5G CPE installation guide

Yeastar Technology

Yeastar Technology UF51 5G CPE installation guide

Encore ENHGS-800X4 datasheet

Encore

Encore ENHGS-800X4 datasheet

EcoFlow EFM100 user manual

EcoFlow

EcoFlow EFM100 user manual

EUCHNER N1A operating instructions

EUCHNER

EUCHNER N1A operating instructions

IOGear GWU647 installation guide

IOGear

IOGear GWU647 installation guide

ATEN ALTUSEN KH1516 user manual

ATEN

ATEN ALTUSEN KH1516 user manual

NETGEAR GS205 installation guide

NETGEAR

NETGEAR GS205 installation guide

Berker Arsys IP44 installation instructions

Berker

Berker Arsys IP44 installation instructions

ATEN CS1762a user manual

ATEN

ATEN CS1762a user manual

AVMATRIX HVS0403U manual

AVMATRIX

AVMATRIX HVS0403U manual

IBM 8275 217 Quick installation guide

IBM

IBM 8275 217 Quick installation guide

Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Administrator's guide

Brocade Communications Systems

Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Administrator's guide

Extron electronics ISS 612 Setup guide

Extron electronics

Extron electronics ISS 612 Setup guide

netsys NS-280FX user manual

netsys

netsys NS-280FX user manual

Hama USB Hub operating instructions

Hama

Hama USB Hub operating instructions

SilverStone EP01 manual

SilverStone

SilverStone EP01 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.