1. This unit is designed to be used with water as the circulating fluid. The quality of fluid used in
your temperature control unit will greatly effect its short and long-term operation. Lack of as
well as improper water treatment can damage the temperature control unit by causing scale
build-up, excessive corrosion and/or bacterial contamination. It is the equipment owner’s
responsibility to prevent damage caused by poor water quality. The services of a water
treatment professional is recommended.
2. Before installing and operating the unit, be aware of and follow any local laws and codes that
apply to the installation.
3. When contacting the Service Department always have the unit Model and Serial number from
the data tag located on the side of the unit.
SERVICE DEPARTMENT: 317-887-0729
*Reference the manual for requirements for 300°F set point.
Installation
Before Installing or Operating
Refer to the Manual for complete details on Installation.
1. Electrical: Be certain all electrical connections are tight in the unit. Install unit power cord (when
supplied) to power disconnect switch. Applied power must be equal to the unit voltage and amps
listed on the unit data tag. Follow all applicable local and national electrical codes.
2. Plumbing: Care should be taken to use materials (hose, rigid piping, valves or filters) rated
for the temperature and pressure duty of your unit. Most units have a maximum operating
temperature of 300°F or less and a maximum pressure of 150 PSI. The unit is most efficient
when full size plumbing is run from the unit connections to and from the process. If necessary,
reduce the plumbing size at your process, not at the unit.
Maximum Setpoint
300°F*
This reference guide covers standard
Advantage temperature control units with the
T300 Series Control Instrument. This guide
may be used for customized units using the
T300 Series Control Instrument even when
the unit may not be physically the same as the
units depicted in the included photos. Download and read the manual before starting installation.
The complete manual is available online at
www.advantageengineering.com/Sentra-SRT-300.
Sentra SR Series with T300 Control Instrument
REFERENCE GUIDE
INSTALLATION • OPERATION • TROUBLESHOOTING
Alert
AC 3-Phase
Setpoint
300
°F
Setup
Ready
Standby
Alert
Sensor (From)
Alert
Sensor (To)
Alert
High Temperature
Alert
Sensor Probe
Alert
Cooling Valve
Alert
Water Pressure
Operating Temperature
Water Supply Pressure
200°F
30 PSI
210°F
35 PSI
220°F
40 PSI
240°F
50 PSI
250°F
50 PSI
275°F
50 PSI
300°F
50 PSI
3. Connect the unit’s To Process port to the
Water In port on the process manifold.
4. Connect the unit’s From Process port
to the Water Out port on the process
manifold.
5. Please note: Process water piping
circuitry should be designed to avoid an
excessive use of elbows and/or lengths
of pipe or hose. If hose is the material
of choice, avoid tight twists or curls and
excessive lengths.
6. Valves and lters may be installed in the
process water piping circuitry to facilitate
service and maintenance, provided that
such devices maintain the full inside
diameter of the process connection. If
installed, all such devices must be open
and clean during unit operation.
7. Connect Unit drain to plant’s open drain,
tower water system return or chilled water
system return. The factory recommends
a minimum of 20 psi pressure differential
between the water supply and drain line.
A larger differential may be required for
larger cooling needs.
8. Connect Unit water supply to plant’s city
water or well water source or tower water
supply or chilled water supply. Water
supply pressure requirements vary with
operating temperatures as shown in the
chart below.
Drain
To Process
From Process
Water Supply
Start Unit Refer to the Manual for complete details on start up and operations information.
1. Fill unit with water.
2. Apply power. The Standby screen will
illuminate. When Standby is displayed,
the unit is not running.
3. A System Fault may prevent startup.
Probe, cooling valve, water supply
pressure, pump overload or high
temperature limit may display once power
is applied and must be corrected prior to
operation.
4. This unit features a touch screen interface panel. Press gently on the screen to navigate. Do not
press the screen with tools or other foreign objects when navigating.
5. Determine that the pump is rotating in a clockwise direction when viewed from the rear of the
motor. Follow the instructions in Section 3.2 of the factory operations manual.
Typical unit with ¾ - 3 HP pump and/or 10 - 16 kW heater.
To Process
300
°F
Setpoint
300
°F
Setup
Cooling
8%
To Process
85
°F
Setpoint
85
°F
Setup
Cooling
8%
To Process
78
°F
Setpoint
300
°F
Setup
Heating
100%
To Process
78
°F
Setpoint
300
°F
Setup
Heating
100%
To Process
78
°F
Setpoint
85
°F
Setup
Standby
To Process
78
°F
Setpoint
300
°F
Setup
Heating
100%
Alert
AC 3-Phase
Setpoint
300
°F
Setup
Ready
Standby
Alert
Sensor (From)
Alert
Sensor (To)
Alert
High Temperature
Alert
Sensor Probe
Alert
Cooling Valve
Alert
Water Pressure
Operating Temperature
Water Supply Pressure
200°F
30 PSI
210°F
35 PSI
220°F
40 PSI
240°F
50 PSI
250°F
50 PSI
275°F
50 PSI
300°F
50 PSI
Controller Basic Controller use is presented.
Refer to the Manual for full information.
6. The unit is ready to start when no errors are shown on the
screen and pump rotation is correct.
7. Press the green start button. The unit will auto vent if the fluid
temperature is below 100°F or as programmed in the features
menu.
8. Adjust the setpoint to the desired value by pressing the Up or
Down button until the value is displayed.
8. The unit will heat or cool to maintain the setpoint temperature.
Stop Unit Refer to the Manual for complete details on shut down information.
1. Decrease the setpoint temperature lower than 85°F and
allow the unit to cool to the temperature.
2. Press the Stop Button to disengage the pump.
3. Caution. Dissipate static pressure before disconnecting hoses.
4. A pump seal cooling feature can be selected from the Features
menu to automatically cool the unit once the stop button is
pressed.
WARNING: When the pump seal cooling feature is activated, pressing the stop button will not
turn off the unit. To completely shut down the unit, press the Stop button twice.
WARNING: proper care should be employed when checking pump rotation as power is applied to
the unit at this point.
The Home Screen is the screen that appears once
the unit has started. It offers To Process temperature,
Setpoint temperature, Setup button, the Tools and Status
button and various machine and alert icons.
• Icons with a gold outline are buttons. Press the button
to advance to different screens.
• Icons with a white outline are indicators and only offer
information.
Setup Button and Screens ... Basic, Remote, Features
and Machine Setup screens are displayed by pressing
the blue Setup button and advancing to the Basic Setup
Screen. The Remote, Features and Machine items can
be pressed to advance to those screens. The Setup
button can be pressed any time it is displayed to advance
to the Basic Setup screen and then to the other set up
screens.
SRT-300
<< Back
More
Basic Remote Features Machine
10 °F
10 °F
0 GPM
<< Back
More
Basic Remote Features Machine
High Devivation
Low Devivation
Low Flow Alarm
Second Setpoint
Remote
Start/Stop
Remote
Setpoint
Communication
<< Back
More
Basic Remote Features Machine
Interface
Pump Seal
Cooling
Pump Stopped
Alarm
Autovent
Screen Locking
System
Information
Basic Remote Features Machine
Max Setpoint
Alarm Output Mold Purge
Enabled
Flow Valve Size
Heat Only Mode
To Process
78
°F
Setpoint
300
°F
Setup
Heating
100%
<< BackManual Vent
AC Phase
Supply Water Pressure
Pump Overlaod
High Temperature Limit
Cooling Valve
To Process Probe
From Process Probe
Tools and Status
Alert
AC 3-Phase
Setpoint
300
°F
Setup
Ready
Standby
Alert
Sensor (From)
Alert
High Temperature
Alert
Sensor Probe
Alert
Cooling Valve
Alert
Water Pressure
Alert
Sensor (To)
Unit Underheats
1. Process water
leakage -
defective cooling
solenoid valve.
2. Heater element
failure.
3. Process heating
requirement
exceeds
unit heating
capability.
4. Control instrument defective.
Pressure Relief Valve Leaks
1. Water supply pressure too high.
2. Pressure relief valve contamination.
Troubleshooting
Controller
Basic Troubleshooting is shown here. Refer to the Manual for full information.
Continued
Current Factory Operations Manual
Scan this QR code to download an electronic PDF copy to a smart phone or tablet. Download the electronic
PDF copy to a desktop computer for view or print: www.advantageengineering.com/Sentra-SRT-300.
If you have any questions regarding this Reference Guide, the Sentra SRT-300 Series Operations Manual,
installation, operation or servicing of the unit, please call the Advantage Service Department.
317-887-0729
525 East Stop 18 Road, Greenwood, IN 46143 phone: 317-887-0729 fax: 317-881-1277
Web site: www.AdvantageEngineering.com Email: [email protected]
Form #ADV-1084 updated 03/23/2023 ©2023 Advantage Engineering, Inc.
Basic Setup ... congures the Low Flow
Alarm, High and Low temperature Deviation.
Remote Setup ... congures Second
Setpoint, Remote Start/Stop, Remote
Setpoint and Communications.
Features Setup ... congures Interface,
Pump Seal Cooling, Autovent, Screen
Locking and Pump Stopped Alarm.
Machine Setup ... congures Max Setpoint,
Alarm Output, Flow, Heat Only Mode, Mold
Purge Enable, Valve Size and System
Information.
Tools and Status Button ... from the
Home screen use the Tools and Status icon
(shown below) to advance Tools and Status
screen. This screen gives the user insights
into the operation and status of the unit. A
Green light indicate the item is functioning
normally A Red light indicates the item is in
a stop or error condition.
Refer to the troubleshooting section for more information
on items that have caused a stop or error condition.
Unit Will Not Start (Display Blank & Off)
1. Fuse open at main power disconnect
2. Transformer fuse open
Unit Will Not Start (Display On)
1. Error or alert indicator displayed.
2. Follow instructions on screen to
troubleshoot and refer to manual or
contact the service department.
Unit Overheats
1. Low water supply pressure.
2. Cooling solenoid valve defective.
3. Drain line obstructed.
4. Instrument defective.
5. Cooling requirement exceeds valve
capacity.
Basic Setup Screen
Features Setup Screen
Remote Setup Screen
Machine Setup Screen
To Process
300
°F
Setpoint
300
°F
Setup
Cooling
8%
To Process
85
°F
Setpoint
85
°F
Setup
Cooling
8%
To Process
78
°F
Setpoint
300
°F
Setup
Heating
100%
To Process
78
°F
Setpoint
300
°F
Setup
Heating
100%
To Process
78
°F
Setpoint
85
°F
Setup
Standby
To Process
78
°F
Setpoint
300
°F
Setup
Heating
100%

This manual suits for next models

10

Other Advantage Control Unit manuals

Advantage Sentra SR Series User manual

Advantage

Advantage Sentra SR Series User manual

Advantage Sentra SR Series User manual

Advantage

Advantage Sentra SR Series User manual

Advantage Sentra SR Series User manual

Advantage

Advantage Sentra SR Series User manual

Advantage Sentra SR Series User manual

Advantage

Advantage Sentra SR Series User manual

Popular Control Unit manuals by other brands

LOVATO ELECTRIC RGK900MC instruction manual

LOVATO ELECTRIC

LOVATO ELECTRIC RGK900MC instruction manual

DIDIESSE Electronic System instruction manual

DIDIESSE

DIDIESSE Electronic System instruction manual

Siemens SPCN110 installation instructions

Siemens

Siemens SPCN110 installation instructions

Epson S1D15710D00B Series Technical manual

Epson

Epson S1D15710D00B Series Technical manual

Digital Equipment ML200-AA Installation

Digital Equipment

Digital Equipment ML200-AA Installation

Hauck MCOV Series instructions

Hauck

Hauck MCOV Series instructions

Audioplex RCLL-1 installation manual

Audioplex

Audioplex RCLL-1 installation manual

Stahl ConSig 7040 Series operating instructions

Stahl

Stahl ConSig 7040 Series operating instructions

Danfoss VLT AutomationDrive FC 360 installation instructions

Danfoss

Danfoss VLT AutomationDrive FC 360 installation instructions

CHERUBINI BLUE BUS TDS Series instructions

CHERUBINI

CHERUBINI BLUE BUS TDS Series instructions

VIEWEG DV-5625-U instruction manual

VIEWEG

VIEWEG DV-5625-U instruction manual

MD mXion TLD user manual

MD

MD mXion TLD user manual

Emerson Dixell XEV20D Quick reference guide

Emerson

Emerson Dixell XEV20D Quick reference guide

Innogy DC operating manual

Innogy

Innogy DC operating manual

Hach 4-20 mA User instructions

Hach

Hach 4-20 mA User instructions

Siemens SINUMERIK 840D Simodrive  611 digital Startup guide

Siemens

Siemens SINUMERIK 840D Simodrive 611 digital Startup guide

TELEVAC MP4AR Series instruction manual

TELEVAC

TELEVAC MP4AR Series instruction manual

Kohler K-2977 Installation and care guide

Kohler

Kohler K-2977 Installation and care guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.