manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Advantech
  6. •
  7. Server
  8. •
  9. Advantech BB-VESR902D User manual

Advantech BB-VESR902D User manual

Documentation Number: 20BB710-10572-00_r4_BB-VESR90x_3020qsg
Before you begin, be
sure you have the following:
BB-VESR901, BB-VESR902D, BB-VESR902T
Ethernet Serial Server
Fast and easy on the web:
www.advantech.com
QUICK START
GUIDE
+ BB-VESR90x Ethernet Serial Server
+ CD with Vlinx Manager S/W and Manuals
+ This Quick Start Guide
+ Network Cable (not included)
+ Serial Cable/s (not included)
+ 10 to 48VDC (6.0W) Power Supply (not included)
Set Up Advanced Parameters
10
1. If you want to set up Advanced parameters, click Advanced on
the Port Network Parameters page.
2. If necessary for your application, select “I want to control when
connections are forced closed, then set up the Network Watch-
dog and Serial Watchdog as required.”
3. If necessary for your application, select “I want to control data
packets are sent over the network, then set up the Character
Count, Forced Transmit, Intercharacter Timeout, Delimiters and
Delimiter Removal as required.”
4. Click Next.
Save And Log Out
11
1. If you have completed the conguration, click Save to save the
conguration to the serial server.
2. To Logout, click the Logout button.
To Test & Verify Operation
12
1. Set up serial server as a TCP Server on serial port 1.
2. Set serial port to RS-232 on serial port 1.
3. Set to 9600 8-N-1 on serial port 1.
4. Loopback serial port 1 by connecting TD to RD.
5. Open a DOS window and type “telnet x.x.x.x yyyy” where x.x.x.x
is the IP address of the serial server and yyyy is the port number
of the serial port.
6. Type characters on the keyboard. The characters should appear
in the window. If not, double check your settings.
SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D
HAZARDOUS LOCATIONS, OR NONHAZARDOUS LOCATIONS ONLY.
CONVENANT À L’EMPLOI DANS LES SITES DANGEREUX DE CLASSE I,
DIVISION 2, GROUPES A, B, C ET D, OU DANS LES SITES NON HASARDEUX
SEULEMENT
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF ANY COMPONENT
MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2.
ATTENTION - DANGER D’EXPLOSION - LA SUBSTITUTION DE COMPOSANTS
PEUT ENTRAÎNER UNE ADÉQUATION À LA CLASSE I, DIVISION 2.
The unit is to be powered by a Class 2 power source, of a grounded-type, when
power is applied to the barrel connector.
L’unité doit être alimentée par une source d’alimentation de classe 2, de type mise à
la terre, lorsque le connecteur du canon est alimenté.
THE POWER CABLE MUST HAVE A MINIMUM RATING OF 80°C.
LE CÂBLE D’ALIMENTATION DOIT AVOIR UNE INDICATION MINIMALE DE 80
°C.
Power cannot be applied to both the terminal block and barrel connectors
simultaneously.
L’alimentation ne peut pas être appliquée simultanément aux connecteurs du bornier
et du barillet.
The use of coaxial cable for the eld wiring shall be in accordance with Class 2/Class
3 requirements in Article 725 of the NEC.
L’utilisation d’un câble coaxial pour le câblage sur site doit être conforme aux
exigences de classe 2 / classe 3 de l’article 725 du NEC.
One Conductor Per Terminal
Un conducteur par borne
Use Copper Wire Only
Utiliser uniquement du l de cuivre
Wire Size: 28 to 16 AWG
Taille de l: 28 à 16 AWG
Tightening Torque: 5 KG-CM
Couple de serrage: 5 KG-CM
Wire Temperature Rating: 105 °C Minimum (Sized for 60 °C Ampacity)
Indice de température du l: 105 °C Minimum (calibré pour 60 °C)
80 °C Maximum Surrounding Ambient Air Temperature
80 °C Température ambiante ambiante maximale
UL Class 1 / Division 2
13
5. If you want the serial server to act as a virtual communications
port for a computer, select VCOM. This allows your computer to
connect to a serial device on the network as if it were connected
to a physical COM port.
6. If you want the serial server to operate in Paired mode with an-
other serial server, select Paired, then congure it as a client or
server and set up the IP address, port numbers and other related
parameters (similar to setting up TCP).
707 Dayton Road | PO Box 1040 | Ottawa, IL 61350
Phone:1 (815) 433-5100 | Fax: 1 (815) 433-5109
www.advantech.com | E-mail: support@advantech-bb.com
All manuals and user guides at all-guides.com
Install the Hardware
Install Vlinx Manager Software
LED Status
1
4
2
1. Connect a 10-48 VDC (58 VDC max.) power supply (6W
required).
2. Connect the network cable from the serial server to a network
drop using a standard network cable.
3. Connect the serial device(s):
• RS-232 with DB9: straight-through for DCE device, null
modem for DTE device.
• RS-232/422/485 with terminal blocks. See Appendix D of
User Manual for pinouts.
UL Installation - See Step #13 for more information.
1. Insert the included CD and it should autostart.
2. Follow the prompts to install the Vlinx Manager software.
Note: Be sure you have administrative rights & disable rewalls.
Set Up Vlinx Manager Software
5
1. Open Vlinx Manager, by clicking:
Start > Programs > B&B Electronics > Vlinx > Vlinx Man-
ager > VESR Serial Server
The Discovery page opens.
Log In
6
1. Click Login. (Password is blank from factory.)
The General page appears.
LED STATUS
Ready Blinks if system is operating correctly.
Port 1 ON indicates serial port open; blinks when data is present on serial port.
Port 2 Same as Port 1. (Present on 2-port units only.)
Link ON indicates Ethernet operating in 100BaseTX;
Blinks when data is present on Ethernet link.
Mode Switch
3
HOLD MODE SWITCH IN for... RESULT
0 to 2 seconds Initiates a Hardware Reset.
2 to 10 seconds Enters Console Mode.
Over 10 seconds Reset to Factory Defaults.
2. To congure via the network, select Network.
3. If you know the IP address, select “The device is at this ad-
dress”, and type in the address. If not, select “I don’t know the
IP address of the device.”
4. Click Connect.
OR...Set Up the Web Interface:
1. Open a browser and type the IP address of the serial server in
the Address Bar.
2. When the serial server is found, the Conguration window
appears.
Set Up Network
7
• The serial server is set at the factory to receive an IP assign-
ment from a DHCP server. If a DHCP server is not available
on your network, it will default to 169.254.102.39.
• If this address does not work with your PC, change your
network settings to:
• IP Address = 169.254.102.1
• Subnet Mask = 255.255.255.0
• Default Gateway = 169.254.102.100
Note: If you need different settings, refer to User Manual, Chapter 4.
Set Up Serial Port Parameters
8
1. Click Port 1 Serial to open the Serial Port Parameters page.
Select the type of serial connection between the serial server
and the serial device (RS-232, RS-422, RS-485 2-wire, or
RS-485 4-wire).
2. Select the Baud Rate, Data Bits, Stop Bits, Parity and Flow
Control needed to communicate with the serial device.
3. If your serial server is 2 port, select the next port in the de-
scription box, then repeat the previous steps.
4. Click Next.
Set Up Port Network Parameters
9
1. Click Port 1 Network to open the Port Network Parameters
page.
2. Select the type of network protocol you want to use: TCP,
UDP, VCOM or Paired Mode.
3. If you select TCP, select whether the serial server will oper-
ate as a Client or Server, then congure the required IP ad-
dress, port numbers and other related parameters.
4. If you select UDP, congure the IP addresses, ports and
other related parameters for the devices you want to receive
from and send to.
All manuals and user guides at all-guides.com

This manual suits for next models

2

Other Advantech Server manuals

Advantech EKI-1351 User manual

Advantech

Advantech EKI-1351 User manual

Advantech EPC-T2000 Series User manual

Advantech

Advantech EPC-T2000 Series User manual

Advantech B+B SmartWorx AirborneM2M BB-ABDN-SE-DP553 User manual

Advantech

Advantech B+B SmartWorx AirborneM2M BB-ABDN-SE-DP553 User manual

Advantech RS-100-RT User manual

Advantech

Advantech RS-100-RT User manual

Advantech sky-8100 User manual

Advantech

Advantech sky-8100 User manual

Advantech EKI-1521 User manual

Advantech

Advantech EKI-1521 User manual

Advantech SKY-8260S User manual

Advantech

Advantech SKY-8260S User manual

Advantech SKY-7210 Installation and operation manual

Advantech

Advantech SKY-7210 Installation and operation manual

Advantech SKY-8132S User manual

Advantech

Advantech SKY-8132S User manual

Advantech EKI-152X series User manual

Advantech

Advantech EKI-152X series User manual

Advantech DVG-1100 User manual

Advantech

Advantech DVG-1100 User manual

Advantech EKI-1528 User manual

Advantech

Advantech EKI-1528 User manual

Advantech ASMB-781 Installation and operation manual

Advantech

Advantech ASMB-781 Installation and operation manual

Advantech ECU-579 Series User manual

Advantech

Advantech ECU-579 Series User manual

Advantech EKI-1511 Series User manual

Advantech

Advantech EKI-1511 Series User manual

Advantech SKY-6200 Installation and operation manual

Advantech

Advantech SKY-6200 Installation and operation manual

Advantech SKY-642 User manual

Advantech

Advantech SKY-642 User manual

Advantech MIC-8303C User manual

Advantech

Advantech MIC-8303C User manual

Advantech BB-VESR90 Series User manual

Advantech

Advantech BB-VESR90 Series User manual

Advantech EKI-1512X User manual

Advantech

Advantech EKI-1512X User manual

Advantech EKI-1528-DR User manual

Advantech

Advantech EKI-1528-DR User manual

Advantech BB-VESR901 User manual

Advantech

Advantech BB-VESR901 User manual

Advantech RS-100-SF User manual

Advantech

Advantech RS-100-SF User manual

Advantech IPC-644 Series User manual

Advantech

Advantech IPC-644 Series User manual

Popular Server manuals by other brands

Oracle Sun Server X4-4 installation guide

Oracle

Oracle Sun Server X4-4 installation guide

Cisco CSACS-1121-K9 reference guide

Cisco

Cisco CSACS-1121-K9 reference guide

Nortel CallPilot 1001rp Installation and configuration

Nortel

Nortel CallPilot 1001rp Installation and configuration

Lenovo ThinkServer RD330 Garantie et support

Lenovo

Lenovo ThinkServer RD330 Garantie et support

Dell E75S Series Installation and service manual

Dell

Dell E75S Series Installation and service manual

Lenovo ThinkServer TD230 Informações sobre Garantia e Suporte

Lenovo

Lenovo ThinkServer TD230 Informações sobre Garantia e Suporte

Intel R1000GL Quick installation user's guide

Intel

Intel R1000GL Quick installation user's guide

Themis RES-11XR3 installation manual

Themis

Themis RES-11XR3 installation manual

Thecus N8900 series user manual

Thecus

Thecus N8900 series user manual

HP DL320 - ProLiant - G3 Quickspecs

HP

HP DL320 - ProLiant - G3 Quickspecs

Netscape NETSCAPE ENTREPRISE SERVER 6.1 - INSTALLATION AND MIGRATION... Installation and migration guide

Netscape

Netscape NETSCAPE ENTREPRISE SERVER 6.1 - INSTALLATION AND MIGRATION... Installation and migration guide

Fujitsu PRIMERGY TX1310 M5 Upgrade and maintenance manual

Fujitsu

Fujitsu PRIMERGY TX1310 M5 Upgrade and maintenance manual

Supermicro SUPERSERVER 6011L user manual

Supermicro

Supermicro SUPERSERVER 6011L user manual

Intel SR1530HSH - Server System - 0 MB RAM user guide

Intel

Intel SR1530HSH - Server System - 0 MB RAM user guide

Avaya S8300 Series manual

Avaya

Avaya S8300 Series manual

Acer Altos G500 user guide

Acer

Acer Altos G500 user guide

Supermicro SuperServer 6011D user manual

Supermicro

Supermicro SuperServer 6011D user manual

NEC N8800-164F user guide

NEC

NEC N8800-164F user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.