AEC ST3200 User manual

User Manual
1kVA ~ 3kVA 220VAC

User Manual 1-3kVA Rev. 9
i
Contents
1.1 General Description..............................................................................................1
1.2 System Configuration...........................................................................................2
`Tower .................................................................................................... ……… 2
`Rack-Mount....................................................................................................3
1.3 Front Panel.........................................................................................................4
1.3.1 Tower ..........................................................................................................4
`LCD .................................................................................... 4
`LED.....................................................................................4
1.3.2 Rack-Mount ..................................................................................................5
1.4 Rear Panel.......................................................................................................... 6
`Tower ............................................................................................................ 6
`Rack-Mount....................................................................................................7
`External Battery Bank or Module .......................................................................8
2. Installation.............................................................................................................9
2.1 Unpacking ..........................................................................................................9
2.2 Installation ....................................................................................................... 11
`Tower .......................................................................................................... 11
`Rack-Mount.................................................................................................. 11
2.3 Connection to communication ............................................................................. 12
2.3.1 Standard.................................................................................................... 12
`RS-232............................................................................... 12
2.3.2 Optional Interface Cards............................................................................... 13
`USB Card ............................................................................ 13
`DB9 Dry Contact Card.............................................................. 13
`AS400 Card ......................................................................... 14
`SNMP/HTTP Agent .................................................................. 14
3. Operation .............................................................................................................15
3.1 LCD and LED Display.......................................................................................... 15
`LCD ............................................................................................................ 15
`LED............................................................................................................. 17
3.2 Starting up/ Shutting down the UPS ..................................................................... 18
3.3 Operating Modes ............................................................................................... 19
3.4 Configuration Settings........................................................................................ 21
`Output Voltage / Frequency ............................................................................ 21
`Bypass Voltage ............................................................................................. 22
4. Maintenance.........................................................................................................23
4.1 General Maintenance ......................................................................................... 23
`Environment................................................................................................. 23
`Storing the UPS and Battery ........................................................................... 23
`Replace the Battery ....................................................................................... 23
4.2 Replacing the New Battery .................................................................................. 24
4.3 Testing the New Battery ..................................................................................... 24
4.4 Recycling the Used Battery ................................................................................. 24
5. Troubleshooting ...................................................................................................25
`LCD............................................................................................. 25
`LED............................................................................................. 27
6. Appendix ..............................................................................................................28
6.1 Specifications.................................................................................................... 28
`General Specification ........................................................................................ 28
`Battery Run Time ............................................................................................. 29
6.2 Contact Information........................................................................................... 30

User Manual 1-3kVA Rev. 9
ii
Important Safety Instructions
SAVE THESE INSTRUCTIONS. This UPS unit operates from utility power and contains a number of high
current back-up batteries, the information is important to all personnel involved. Please read this manual
before installation and operation of the UPS.
Safety of Persons
ÎOpening or removing the cover of the unit may expose you to lethal voltage within the unit, even if it is
apparently not in operation and the input wiring is disconnected from the electrical source.
ÎRefer all UPS and battery servicing to authorized service personnel from the manufacturer or an agent authorized
by the manufacturer.
ÎDo not dispose of the battery in a fire, as the battery may explode.
ÎDo not open or damage the battery. Battery acid is toxic and harmful to eyes and skin.
ÎThe following precautions should be observed when working on batteries:
•Remove watches, rings, and other metal objects.
•Use tools with insulated handles.
Product Safety
ÎInstall the UPS in a clean environment, free from moisture, flammable gases or fumes and corrective
substances.
ÎKeep the UPS on a flat, stable surface with a 10cm space around it for proper ventilation.
ÎOperate the UPS in an indoor environment only in an ambient temperature range of 32oF to +104oF (0oC to
+40oC).
ÎThe UPS is designed for data processing equipment. It is not intended for use with life support and other
designated “critical” devices.
ÎThe maximum load must not exceed that shown on the UPS rating label.
ÎStoring magnetic media on top of the UPS may result in data loss or corruption.
ÎOnce batteries have reached the end of their life, ensure they are disposed of properly. REFER TO YOUR LOCAL
LAWS AND REGULATIONS FOR BATTERY DISPOSAL REQUIREMENTS.
ÎThe UPS must be handled with care and attention since there is high energy stored within the batteries. It must
always be kept in the position marked on the external packaging and must not be dropped.
ÎPlease keep the exhaust holes of UPS unobstructed.
ÎThe battery should be maintained at regular intervals.
Special Precautions
ÎThe UPS should be installed according to the instructions in this manual. Failure to do so could result in safety
issues. It could also invalidate your warranty.
ÎDO NOT CONNECT equipment that could overload the UPS or demand half-wave rectification from the UPS, for
example: electric drills, vacuum cleaners, printers or hair dryers.
ÎAdjust only those controls that are listed in the Adjustment Section. If the unit does not operate normally by
following the operating instructions, contact the sales representatives.
Icon Usage
These icons may be found in the contents.
WARNING: Obvious danger to personnel or equipment.
CAUTION: Possible danger to personnel or equipment
Important information

User Manual 1-3kVA Rev. 9
- Page 1 of Total 30 -
1. Presentation
1.1 General Description
The continuity of electrical power is an essential requirement for critical load operations .The
Uninterruptible Power System (UPS) is a compact and quiet solution for power protection of
computer, server and office equipment.
To choose the UPS as your equipment protector is a wise investment as it supplies reliable, pure and
stable power at an affordable price.
Feature & Benefits:
9True on-line double conversion
9PWM technologies w/ IGBTs
9Wide input voltage range
9DC Start
9Battery self-test
9Microprocessor based control
9User-friendly LCD or LED
9Communication ports: Standard RS232 and optional communication slot for either DB9,
USB, AS-400 or SNMP/HTTP card.
9Light weight unit
9Optional external battery slot for long runtime requirement
Application:
9Computers
9Network Servers
9Workstations
9Wireless Communication
9Other Electronic Peripherals

User Manual 1-3kVA Rev. 9
- Page 2 of Total 30 -
1. Presentation
1.2 System Configuration
`Tower
1kVA: 160W x 220H x 400D mm / 15 kgs
2kVA:200W x 352H x 450D mm / 34 kgs
3kVA:200W x 352H x 450D mm / 35 kgs

User Manual 1-3kVA Rev. 9
- Page 3 of Total 30 -
1. Presentation
`Rack-Mount
1kVA: 440W x 88H x 465D mm / 15.5 kgs
2kVA: 440W x 88H x 465D mm / 35 kgs
3kVA: 440W x 88H x 465D mm / 36 kgs

User Manual 1-3kVA Rev. 9
- Page 4 of Total 30 -
1. Presentation
1.3 Front Panel
1.3.1 Tower
`LCD
1 2 3 4 5 6 7
1. 2-line LCD Display
2. Normal LED (green)
3. Warning LED (yellow)
4. Fault LED (red)
5. Select-up button
6. Select-down button
7. Enter button
5-6. Off button
6-7. On button
5-7. Test/Silence button
`LED
1 2 3 4 5 6 7 8 9
1. Line LED (green)
2. Load & Battery Capacity LEDs
3. Battery LED (yellow)
4. Bypass LED (yellow)
5. Fault LED (red)
6. Inverter LED (green)
7. Select-up button
8. Select-down button
9. Enter button
7-8. Off button
8-9. On button & Test/Silence button

User Manual 1-3kVA Rev. 9
- Page 5 of Total 30 -
1. Presentation
1.3.2 Rack-Mount
1 2 3 4 5 6 7
1. 2-line LCD Display
2. Normal LED (green)
3. Warning LED (yellow)
4. Fault LED (red)
5. Select-up button
6. Select-down button
7. Enter button
5-6. Off button
6-7. On button
5-7. Test/Silence button

User Manual 1-3kVA Rev. 9
- Page 6 of Total 30 -
1. Presentation
1.4 Rear Panel
`Tower
○
1○
6○
1○
6
○
7○
7
○
1○
6○
2○
8○
2○
8
○
7○
9○
9
○
2○
8
○
9
○
10
○
3
○
4○
4
○
4
○
5
○
5○
5○
3○
3
1kVA 2kVA 3kVA
1. Standard RS232 Port
2. Fan
3. External Battery Slot (Option)
4. Input Breaker
5. Inlet
6. Communication ports: DB9, USB, AS400, SNMP/HTTP (Option)
7. Surge Protection: RJ45
8. LCD Remote Control (Option)
9. Outlets (IEC, German)
10. Outlets (Terminal Block for 3kVA only)

User Manual 1-3kVA Rev. 9
- Page 7 of Total 30 -
1. Presentation
`Rack-Mount
1kVA
○
1○
2○
3○
4○
5○
6
○
7○
8○
9
2kVA
○
4○
3○
6○
2○
5○
9
○
7○
1○
8
3/2(long run time)kVA
○
4○
3○
6○
2○
5○
9
○
7○
1○
8○
11 ○
10
1. External Battery Slot (Option)
2. Outlets (IEC 10A,Germen)
3. Inlet
4. Input fuse
5. Fan
6. Communication Ports:DB9,USB,AS400,SNMP/HTTP (Option)
7. LCD Remote Control (Option)
8. Surge Protection: RJ 45
9. Standard RS232 Port
10. Output Terminal
11. Output fuse

User Manual 1-3kVA Rev. 9
- Page 8 of Total 30 -
1. Presentation
`External Battery Bank or Module
For Tower Product ranges:
For Rack-Mount product ranges:

User Manual 1-3kVA Rev. 9
- Page 9 of Total 30 -
2. Installation
2.1 Unpacking
The ST Series UPS can be supplied in a varied number of boxes depending upon the
model ordered. The number of boxes provided should be as follows:
MODEL (Box 1) BATTERYMODULE (Box2) TOTAL BOXES
ST 3200 Tower N/A (internal batter 1 Box
ST 3200R Rack Mount N/A (internal battery) 1 Box
ST 3200R Rack Mount 1 Battery Module 2 Boxes
STSeries 1kVA ~ 3kVA Tower
Box 1
c
def
Shipping Box Includes:
1. UPS
2. User Manual
3. Input Power Cord (German, British, Australian)
4. Extension Power Cord (IEC) to PC (for output receptacles “IEC” only)
You may find the “series number” labeled on both shipping box and UPS
rear panel. If the UPS has a problem please send the number to your
sales representative for tracking and troubleshooting.

User Manual 1-3kVA Rev. 9
- Page 10 of Total 30 -
2. Installation
STSeries 1-3kVA Rack Mount
Box 1
c
defg
Shipping Box Includes:
1. UPS
2. User Manual
3. Input Power Cord (German, British, Australian)
4. Extension Power Cord (IEC) to PC (for output receptacles “IEC” only)
5. 2pcs 19” rack ears (+screws)
Box 2 (for 2/3kVA Rack Mount and external battery module)
c
de
Box 2 Includes:
1. Battery Module
2. 2pcs 19” rack ears (+screws)
3. Battery cable

User Manual 1-3kVA Rev. 9
- Page 11 of Total 30 -
2. Installation
2.2 Installation
`Tower
Optional Communication Slot
Standard RS232 to PC
AS400
RJ45 protection for
Tel/Fax/Modem/DSL
Remote control
USB
To external battery
cabinet
DB9
Output to the loads
To the wall socket
SNMP/HTTP
`Rack-Mount
To the wall socket Optional Communication Slot
Output to the load
To external battery
cabinet
Standard RS232 to PC
Remote control
RJ45 protection for Tel/Fax/Modem/DSL
Keep the UPS on a flat, stable surface with a
10cm space around it for proper
ventilation.

User Manual 1-3kVA Rev. 9
- Page 12 of Total 30 -
2. Installation
2.3 Connection to communication
2.3.1 Standard
`RS-232
The communication interface (DB9 port) on the back of the UPS may be connected to a host
computer with specific monitoring software installed. (Please contact a sales representative for
further information of monitor software)
The pins of the connector are as following:
The RS-232 interface settings are as follows:
PIN # PIN Definition (UPS) PIN Definition (PC)
2 Transmitted data Received data
3 Received data Transmitted data
5 Signal Ground Signal Ground
Baud Rate 2400 bps
Data Length 8 bits
Stop Bit 1 bit
Parity None

User Manual 1-3kVA Rev. 9
- Page 13 of Total 30 -
2. Installation
2.3.2 Optional Interface Cards
A variety of interface cards can be installed into optional communication slot such as DB9 Dry
Contact Card, USB Card, AS400 Card, and SNMP/HTTP Card.
`USB Card
`DB9 Dry Contact Card
Pin Definition of DB9 for NOVELL Interface
PIN # of DB9 Function explanation I/O
1 UPS Fault Output
3 GND Input
4 Remote Shutdown UPS(+12VDC)(work on Battery
Mode) Input
5 Input 12VDC Input
6 Bypass Mode Output
7 Low Battery Output
8 Normal Mode, Battery Mode Output
9 Utility Power Fault Output

User Manual 1-3kVA Rev. 9
- Page 14 of Total 30 -
2. Installation
`AS400 Card
`SNMP/HTTP Agent
NetAgent Mini allows a user to obtain the status, and issue commands to the UPS. The
communications protocol includes the MegaTec/ PPC/ SEC 2400 / 9600. Also it is possible to build
in your own protocol. NetAgent Mini provides a simple and easy installation procedure. The user
only needs to install the software from the NetAgent Mini CD on a Windows environment and
configure the IP address.
All the other configurations could be accomplished in a Web browser. NetAgent Mini also
provides shutdown programs for different operating systems. Shutdown commands can be sent
for such events as power failure, low UPS battery condition, UPS overload, UPS overheating and
scheduled shutdowns. All shutdown events are configurable by the user. The shutdown
software provides an orderly shutdown to prevent the abnormal shut-off of clients or servers.
Please refer to the NetAgent Mini installation CD for more
information.

User Manual 1-3kVA Rev. 9
- Page 15 of Total 30 -
3. Operation
3.1 LCD and LED Display
`LCD
Display 1 - Welcome screen
AEC Star T3 Series
On-Line UPS
Display 2 - Input/Output Voltage
and Frequency Input:220V 50Hz
Identification Output:220V 50Hz
Display 3 – UPS Status AC:FAIL BATT:LOW
NO Output
Display 4 – Real Input/Output
Voltage and Frequency Input Voltage
220 VAC
Output Voltage
220VAC
Input Frequency
50 Hz
Output Frequency
50 Hz
“Select-Down” Key: “Select-Up” Key:
yThe welcome screen only shows for 10 seconds as UPS starts up,
after that the “UPS Status” will show on the display.
yThe screen should go back to “UPS Status” if you do not push any
buttons for 2 minutes.

User Manual 1-3kVA Rev. 9
- Page 16 of Total 30 -
3. Operation
Display 5 – Battery Voltage/
Capacity Battery Voltage
37 VDC
Battery Capacity
100 %
Display 6 – Output Power
Output Power
100 %
Display 7 – Inside Temperature
Inside TEMP
33 ℃91 ℉
Display 8 – New Alarm
NEW AC Fail: 1
ALM Overload: 3
Display 9 – Old Alarm
OLD AC Fail: 5
ALM Overload: 9
Display 10 – Bypass Voltage Setting Bypass Volt Set
LO= 176V HI=253V
Display 11 – Output Voltage/
Frequency Setting Volt/Freq Set
220 VAC 50 Hz

User Manual 1-3kVA Rev. 9
- Page 17 of Total 30 -
3. Operation
`LED
1 6 7 8 9 10 2 3 4 5
1. Line LED (green): This indicates the AC power is applied to the UPS input. If the LED blinks, it
means the AC power source is out of tolerance.
2. Battery LED (yellow): This indicates the UPS is in Battery Mode.
3. Bypass LED (yellow): This indicates the UPS is in Bypass Mode.
4. Fault LED (red): This indicates the UPS is in fault condition because of UPS shutdown or
over-temperature
5. Inverter LED (green): This indicates the inverter is working normally.
6-10. Load & Battery Capacity LEDs:
(a) No. 6 to 7 LED is green color, No. 8 to 9 is yellow and No.10 (used as warning LED for
overload or battery low) is red.
(b) These LEDs show the load (%) of the UPS if the AC input is available (in Normal Mode).
LEDs light up to indicate the following information.
No. 6 LED: 0-25 % No. 6 - 9 LEDs: 76-100 %
No. 6 - 7 LEDs: 26-50 % No. 6 - 10 LEDs: Overload
No. 6 - 8 LEDs: 51-75 %
(c) In the Battery Mode, the LEDs indicate the capacity (%) of the batteries. LEDs light up
to indicate the following information.
No. 10 LED: 0-25 % (battery low level)
No. 9 - 10 LEDs: 26-50 % No. 7 - 10 LEDs: 76-95 %
No. 8 - 10 LEDs: 51-75 % No. 6 - 10 LEDs: 96-100 %
This manual suits for next models
7
Table of contents
Other AEC UPS manuals